Green house cons presentation

347 views

Published on

0 Comments
1 Like
Statistics
Notes
  • Be the first to comment

No Downloads
Views
Total views
347
On SlideShare
0
From Embeds
0
Number of Embeds
3
Actions
Shares
0
Downloads
0
Comments
0
Likes
1
Embeds 0
No embeds

No notes for slide

Green house cons presentation

  1. 1. Mohammed Zaid “ green houses presentation :  all  ontribution  bearing  to LEED  system  credits    Using Insulated    Insulating Concrete Form (ICF) construction is a concrete forms  consistently strong contributor to any these  green build measures.    Perhaps the most recognized is the US Green Foam blocks called insulated concrete forms or  Building Council Leadership in Energy and ICFs; offer a new style of concrete construction  Environmental Design (LEED) Green Building for residential as well as commercial structures.   Rating System. LEED promotes a whole‐building These hollow blocks are pounds lighter than  approach with performance criteria in five areas Standard masonry blocks because they are   made of expanded polystyrene ‐ similar to the  Sustainable site development white, Insulating foam used for take‐out coffee   Water savings cups.   Energy efficiency                                                                 Materials selection They  are separate panels connected with  Indoor environmental quality. plastic ties.    During construction, the forms are filled with  Using ICFs for the building envelope can reduce concrete, becoming a permanent part of the  temperature  and  humidity  variables,  and wall assembly as well as adding a two‐inch thick  facilitate the maintenance. layer of foam insulation to each side of the wall.  insulating  Concrete  Forms  offer  the  most Reinforcing bars can be added for earthquake  straightforward solution for an environmentally safety.   preferred, energy efficient thermal envelope so Boasting an R‐value of 21 and up(see next  vital to sustainable construction. section for R‐value definition), foam block walls are so well insulated that manufacturers predict a homes monthly heating and cooling costs can  Energy Performance be reduced up to 75 percent. As a result of the   added insulation, the size of the homes heating  A quick review of the 69 possible points and cooling system could be reduced by as  available in the LEED for New Construction much as 50 percent.   (LEED NC) identifies energy savings as the most   heavily weighted criteria, with up to 10 points The walls are fire, earth quake and termite  achievable. This strong focus on energy savings resistant, and the layers of foam insulation  is appropriate considering the bulk of a provide excellent soundproofing as well as  building’s environmental footprint is caused by backing for drywall on the inside and stucco, lap  the energy consumed in the heating and cooling siding or brick on the outside.  of a structure over the course of its lifetime.        M_as@hotmail.com M_as3@yahoo.com 
  2. 2. Mohammed Zaid “ green houses presentation : Sustainable Construction        Materials and Resources Credit 8, Durable Building with the intent of minimizing construction waste due to premature failure of the building from moisture and structural deterioration.   Durability  ICFs protect the concrete with layers of EPS foam, which is a stable material and not subject to deterioration or loss of thermal value.  Five Ways ICFs Help Build Green  1. Optimized Energy Performance 2. Durability 3. Recycled Material Content 4. Local Materials 5. Improved Indoor Air Quality  Reduced foot print  Sustainable Sites Credit 5.1 calls for reducing the development footprint and limiting site   disturbance to conserve existing natural areas. ICF construction can reduce impact to a construction site, as the bracing is typically erected on the inside of the ICF wall, with limited construction activity around the perimeter.  Noise reduction  Stiffened Raft  Compared to a typical wood frame wall, only about one‐quarter to one‐eighth as much sound penetrates through an ICF wall. Scientists would describe loud speech on the opposite side of a frame wall as "audible, but not intelligible." On the opposite side of an ICF wall, a listener would "strain to hear" loud speech. It would be virtually "inaudible."  Insulated Concrete Form Flat systemM_as@hotmail.com M_as3@yahoo.com 
  3. 3. Mohammed Zaid “ green houses presentation : P oints towards highly likely that the aggregate concrete used to  fill the forms will qualify.  LEED certification Sustainable Sites Credit 5‐Protect or    restore habitat     ICF Construction, Green roof & precast hollow   core slabs can help to protect the habitat on a    construction site, bracing is typically installed The following are points that can be gained  only on the interior of the structure and directly by using ICF system   minimal construction activity occurs outside the  perimeter Energy & Atmosphere prerequisite 2 –Minimum Energy performance  Sustainable Sites Credit 7‐ Landscape (Required)  and exterior Design to reduce heat  islands, Non‐Roof  An ICF building envelope exceeds the mandatory performance requirements,  ICF walls provide flexibility when choosing insulation, thermal‐mass and reduced air  exterior finish including Light colored and highly infiltration.  reflective finishes. Green Roofs reduces air pollution and reduces  Proposed Villa here white & beige colors have required cooling during summertime which  been chosen for the external walls which is reflect Minimum Energy needed for building  always used to reflect sunlight directly falls on cooling.  the external walls which reduces the heat gain  for the walls  Materials & resources Credit 4‐  External landscaping and Green roof Recycled Content  landscaping have been chosen to reduce heat The polypropylene webs in most ICFs are  island  typically made of 100% post‐industrial recycled   materials and often make up approximately 60% of the product by weight. In addition   Portland cement used in the form cavity can contain a significant amount of fly ash   (Recycled)    Green media made of chosen 100% nature fibers     Materials and resources credit 5 –   Regional materials    Depending on the building site location, some or all of the ICF materials may have been   manufactured within a 500 mile radius ( if the   product is shipped by water or rail , this radius is expanded to 1500 miles).in addition , it is M_as@hotmail.com M_as3@yahoo.com 
  4. 4. Mohammed Zaid “ green houses presentation :  nsulated   Maximum Aggregate Size  The nominal maximum size of coarse aggregate shall  concrete   not exceed one‐fifth the narrowest distance  between sides of forms, or three‐fourths the clear  spacing between reinforcing bars or between a bar  forms   and the side of the form.  Exception: When approved, these limitations shall  not apply where removable forms are used and DIMENSIONS OF WALLS  workability and methods of consolidation permit   concrete to be placed without honeycombs or voids. Concrete walls constructed in accordance with   PCA/ICFA  requirements shall comply with the  Compressive Strength shapes and minimum concrete cross sectional dimensions required Other types of The minimum specified compressive strength of forming systems resulting in concrete walls not  concrete, f c, shall be (17.2 MPa) at 28 days. For in compliance with ICF requirments shall be  buildings assigned to Seismic Design Category D0, D1 designed in accordance with the applicable  or D2, the minimum f c shall be (20.7 MPa). building code, or where there is no code in   accordance with ACI 318.  Steel Reinforcement    Flat Wall Systems  Reinforcement shall comply with ASTM A615, ASTM  A706,or ASTM A996. ASTM A996 bars produced   from rail steel shall be Type R. In all buildings Flat walls shall have a minimum nominal  assigned to Seismic Design Category D0, D1 or D2, concrete thickness of (152 mm) for basement  reinforcement shall comply with ASTM A615 Grade walls, and (102 mm) for above‐grade walls.  60 (420 MPa), provided the steel complies with For multiple dwellings assigned to Seismic  Section 21.2.5 of ACI 318, or ASTM A706 Grade 60 Design Category C and all buildings assigned to  (420 MPa). Seismic Design Category D0, D1 or D2, the   minimum nominal thickness of above grade  Lap Splices walls shall be (152 mm).     The maximum gap between noncontact parallel bars CONCRETE  at a lap splice shall not exceed the smaller of one‐ fifth the required lap length and 6 inches (150 mm). Concrete and Materials for Concrete   Materials used in concrete, and the concrete  Continuity of Wall Reinforcement itself shall conform to requirements of the  Between Stories applicable building code, or where there is no  Vertical reinforcement shall be continuous from the code shall conform to ACI 318.  bottom of the foundation wall to the roof. Where  splices are needed to provide the required   continuity, dowel bars with a size and spacing to Concrete Mixing and Delivery  match the vertical above‐grade concrete wall   reinforcement shall be embedded in the foundation  wall the distance required to develop the Mixing and delivery of concrete shall comply  dowel bar in tension . with the applicable building code, or where   there is no code shall be in accordance with ASTM C94 or ASTM C685.    M_as@hotmail.com M_as3@yahoo.com 
  5. 5. Mohammed Zaid “ green houses presentation :  ypical  details   Some of the typical details for  walls reinforcement and connections           M_as@hotmail.com M_as3@yahoo.com 

×