Presentation
On
Vocational Training
(Session 8july-19aug)

Topic:- 132KV/33KV
Sub-Station
SUBSTATION
Substation:- Substation is an intermediate switching, transforming or converting station
between the generating...
BIHAR STATE POWER AND TRANSMISSION COMPANY LTD
(BPHCL)

)
Single Line Diagram:-
TRANSFORMER:

A transformer is a static
piece of apparatus by
means of which electric
power in one circuit is
transformed ...
Specification of Transformer : Continuous rating MVA
=
32/40
Numbers of unit
=
Two(2 nos)
Phase
=
50Hz
Frequency
=
132/33 ...
Cooling
=
ONAN/ONAF
Terminal arrangement
=
(1) H.V. 145KV/1250
amps, 650 BIL 300 BCT OIP
condenser bushing with arching ho...
CURRENT TRANSFORMER
Current transformers
are used for reducing
or stepping down A.C.
current from higher
value to lower fo...
VOLTAGE TRANSFORMER
Voltage transformers are
used for protection and
measurement.
Accordingly they are
either measuring ty...
Power Transformer

Transformer is a
static
electromagnetic
machine which
transforms
alternating current
from one A.C.
volt...
Use And Application of Power Transformer:

GENERATION
TRANSMISSION
DISTRIBUTION
RECTIFIER PLANTS
CIRCUIT BREAKER:

It is an automatic device
capable of making and
breaking an electric circuit
under normal & abnormal
con...
TYPES OF CIRCUIT BREAKER:
1. Air circuit-breaker miniature circuit breaker
(ACB).
2. Oil circuit-breaker tank type or bulk...
Relay:
A relay is an
electrically operated swi
tch. Relays are used
where it is necessary to
control a circuit by a
low-po...
Isolator
• Isolator can be rewritten as
isolator is a manually operated
mechanical switch which
separates a part of the
el...
Lightning Arrester
• A lightning arrester is placed
where wires enter a
structure, preventing damage
to electronic instrum...
Wave Trap
• It is used to trapping the high
frequency communication
signals sent on the line from
the remote substation an...
Presented By:
Upcoming SlideShare
Loading in...5
×

Mit ppt 132/33kv ppt

3,521

Published on

ppt on 132/33 kv substation presentation

Published in: Education, Business, Technology
3 Comments
6 Likes
Statistics
Notes
No Downloads
Views
Total Views
3,521
On Slideshare
0
From Embeds
0
Number of Embeds
0
Actions
Shares
0
Downloads
318
Comments
3
Likes
6
Embeds 0
No embeds

No notes for slide

Mit ppt 132/33kv ppt

  1. 1. Presentation On Vocational Training (Session 8july-19aug) Topic:- 132KV/33KV Sub-Station
  2. 2. SUBSTATION Substation:- Substation is an intermediate switching, transforming or converting station between the generating station and the low tension distribution network situated generally the consumer’s load centre. Function of the substation:- The sub-station receives power from the generating station by a single or more feeders at a high voltage, transform the same to the different distribution voltages and sends to different consumers through distribution network.
  3. 3. BIHAR STATE POWER AND TRANSMISSION COMPANY LTD (BPHCL) )
  4. 4. Single Line Diagram:-
  5. 5. TRANSFORMER: A transformer is a static piece of apparatus by means of which electric power in one circuit is transformed into electric power of the same frequency in another circuit.
  6. 6. Specification of Transformer : Continuous rating MVA = 32/40 Numbers of unit = Two(2 nos) Phase = 50Hz Frequency = 132/33 kv Normal voltage ratio at no load = Star/Delta Connections = ᵞ nyno Vector group = +5% to 15% of132 KV in 1.25% step Tapping range = Type – SN /50012/350/300/16-0CRT male Details of C.T. = (1) H.V. WTI C.T. single core ring type, 10VA ratio 205.8/1.8 class-5, fitted inside HV bushing current in 2V terminals. (2) L.V. WTI C.T. single core ring type 10VA Ratio:- 6.99/1.8 amps class5, fitted inside L.V. bushing current in 2V terminal.
  7. 7. Cooling = ONAN/ONAF Terminal arrangement = (1) H.V. 145KV/1250 amps, 650 BIL 300 BCT OIP condenser bushing with arching hours. Coverage distance:- 1300mm. (2) L.V. 52KV/1250 amps, 250 BIL 100 BCI OIP condensers bushing with arching hours. Creep age distance: - 1300. (3) H.V. ‘N’ & L.V. ‘N’ 52KV/1250 amps 250BIL , 100 BCT OIP condenser bushing without arching hours. Creep age distance:- 1300mm. Total weight of transformer = 73500Kg Weight/quantity of oil = 15000Kg/16900
  8. 8. CURRENT TRANSFORMER Current transformers are used for reducing or stepping down A.C. current from higher value to lower for measurement protection or control Types of Current Transformer: 1. Ring type C.T. or
  9. 9. VOLTAGE TRANSFORMER Voltage transformers are used for protection and measurement. Accordingly they are either measuring type or protective type voltage transformers. They may be either single or three phases. The primary of voltage transformer is connected directly to power circuit between
  10. 10. Power Transformer Transformer is a static electromagnetic machine which transforms alternating current from one A.C. voltage at same frequency & at the same apparent power from one winding via
  11. 11. Use And Application of Power Transformer: GENERATION TRANSMISSION DISTRIBUTION RECTIFIER PLANTS
  12. 12. CIRCUIT BREAKER: It is an automatic device capable of making and breaking an electric circuit under normal & abnormal condition such as short circuit.
  13. 13. TYPES OF CIRCUIT BREAKER: 1. Air circuit-breaker miniature circuit breaker (ACB). 2. Oil circuit-breaker tank type or bulk oil (OCB). 3. Minimum oil circuit-breaker (MOCB). 4. Air blast circuit-breaker (ABCB). 5. Sulfur hexafluoride circuit-breaker (single pressure or double pressure). 6. Vacuum circuit-breaker (VCB).
  14. 14. Relay: A relay is an electrically operated swi tch. Relays are used where it is necessary to control a circuit by a low-power signal or where several circuits must be controlled by one signal. Relays were used extensively in
  15. 15. Isolator • Isolator can be rewritten as isolator is a manually operated mechanical switch which separates a part of the electrical power system normally at off load condition.
  16. 16. Lightning Arrester • A lightning arrester is placed where wires enter a structure, preventing damage to electronic instruments within and ensuring the safety of individuals near them. Lightning arresters, also called surge protector.
  17. 17. Wave Trap • It is used to trapping the high frequency communication signals sent on the line from the remote substation and diverting them to the telecom/teleprotection panel in the substation control room. Line trap also is known as Wave trap
  18. 18. Presented By:
  1. ¿Le ha llamado la atención una diapositiva en particular?

    Recortar diapositivas es una manera útil de recopilar información importante para consultarla más tarde.

×