  1. 1. DE HEUS7 / 9-May-2012
  2. 2. Presented by ELSAMOUL OSMAN & RIHAM MIRGHANYSupervised by DR:EL WALEED ALI
  3. 3. Introduction:-About DE HEUS DE HEUS  DE HEUS DE HEUS  Voeders GMP +  DE HEUS 
  4. 4. - DE HEUSCountry Commercial -Name De Heus Voeders B.V.The Netherlands: Koudijs Feed B.V.Czech: De Heus a.s.South Africa: De Heus Feed Ltd.Vietnam: De Heus Vietnam LLCRussia: Koudijs MKormaEgypt: Koudijs KapoEthiopia: Alema Koudijs Feed PLCBelgium: Nukamel N.V.
  5. 5. - DE HEUS  Wellhope  
  6. 6. Laboratory Analysis
  7. 7. 
  8. 8. NIRS
  9. 9. GRAINDING
  10. 10. WET CHAMICAL LAB Moisture Determination. Protein Determination. Fiber Determination. Ash Determination . Fat EXTRACION .
  11. 11. SAMPLE STORAGE
  12. 12. LABLING : Type of Sample: Date : 02-05-2012 Code :98766 Tel :+56789
  13. 13. GRAINDIG / MIXING:
  14. 14. Fat EXTRACION :The fat is obtained by the direct extraction ofthe sample with warm light petroleum ether ,boiling range of 40-60 C .The solvent isremoved and the dry fat weight.
  15. 15. FAT DIRECT THROUGHSOXHLET:
  16. 16. Crude Fiber:The sample is boiled for 35 minutes in dilutedsulphoric acid. After filtration and washingthe sample is boiled again for 35minites indiluted potassium hydroxide .After filtrationwashing and drying the residue is ashed at500 C .The difference in weight before andafter ashing is called crude fiber ..
  17. 17. .
  18. 18. Moisture:The sample is dried out at 103 °C( ± 1 °C ) for 4 hours to a constant weight .Theweight difference represents the watercontent..
  19. 19. Atomic Absorption SpectrophotometerSample are boiled with HCL ,filtrated ,whennecessary diluted and than measured byAtomic Absorption Spectrophotometer atspecific wavelengths per element..
  20. 20. Atomic Absorption Spectrophotometer.
  21. 21. chloride testDetermination of chloride in compound feedsand raw materials by potentiometric titrationwith silver nitrate using the Ag-electrode.
  22. 22. CRUD PROTEIN ACCORDINGKJELDAHLThe sample is mineralized by concentrated sulphoric acid in the presence of a catalyst. in this way it is transformed into ammonium sulphate. After an addition of hydroxide ,the solution is distilled and ammonical nitrogen is caught in diluted acid and determined by the titration method.
  23. 23. r.
  24. 24. .

×