COMMERCIAL HEAT PUMPSRESIDENTIAL HEAT PUMPS
2    ICS HEAT PUMP TECHNOLOGY    DeLonghi-Climaveneta    PARTNERSHIP    The ICS Group has a strong historical    relations...
3CONTENTS  ICS DELONGHI-CLIMAVENETA PARTNERSHIP                   pg 2  DELONGHI-CLIMAVENETA                              ...
4    DeLonghi-Climaveneta                     PRODUCT INNOVATION    RESEARCH & DEVELOPMENT          HEAT PUMP FOCUS       ...
5A COMPLETE RANGE OF HEATPUMPS FROM 5KW TO 400KW,A BRAND THAT IS SYNONYMOUS   WITH RELIABILITY & QUALITY,WITH ALL THE ADVA...
6    ICS HEAT PUMP    TECHNOLOGY    ICS Heat Pump Technology provides a complete service offering design/specification sup...
7     APPROVED PARTNER PROGRAMME   SUPPORT  ICS Heat Pump Technology & DeLonghi-Climaveneta  provides a specialist support...
8    CASE STUDIES    RESIDENTIAL CASE STUDY NEW BUILD WITH SUBSTANTIAL REFURBISHMENT    Property:         5 bedroom 400sq/...
9COMMERCIAL CASE STUDY NEW BUILD SCHOOLProperty:         SchoolApplication:      New Build School 90kWLocation:         Ru...
10     AIR SOURCE     MEDIUM & HIGH     TEMPERATURE HEAT PUMPS     MEDIUM TEMPERATURE AIR SOURCE HEAT PUMPS              U...
11Our air source heat pumps provide a very efficient means of utilising renewable energywhilst being very straightforward ...
12                                                                                                                        ...
13                                                                  Bran H Air Source Medium Temperature Heat PumpsMain Co...
14                                                                                                                        ...
15                                                               MTD XE Air Source Medium Temperature Heat PumpsMain Compo...
16                                                                                                                        ...
17                                                    DHW Twin Air Source Medium Temperature Heat PumpsMain Components• Ho...
18                                                                                                                        ...
ICS Heat Pump Technology Product Guide Feb 2011
ICS Heat Pump Technology Product Guide Feb 2011
ICS Heat Pump Technology Product Guide Feb 2011
ICS Heat Pump Technology Product Guide Feb 2011
ICS Heat Pump Technology Product Guide Feb 2011
ICS Heat Pump Technology Product Guide Feb 2011
ICS Heat Pump Technology Product Guide Feb 2011
ICS Heat Pump Technology Product Guide Feb 2011
ICS Heat Pump Technology Product Guide Feb 2011
ICS Heat Pump Technology Product Guide Feb 2011
ICS Heat Pump Technology Product Guide Feb 2011
ICS Heat Pump Technology Product Guide Feb 2011
ICS Heat Pump Technology Product Guide Feb 2011
ICS Heat Pump Technology Product Guide Feb 2011
ICS Heat Pump Technology Product Guide Feb 2011
ICS Heat Pump Technology Product Guide Feb 2011
ICS Heat Pump Technology Product Guide Feb 2011
ICS Heat Pump Technology Product Guide Feb 2011
ICS Heat Pump Technology Product Guide Feb 2011
ICS Heat Pump Technology Product Guide Feb 2011
ICS Heat Pump Technology Product Guide Feb 2011
ICS Heat Pump Technology Product Guide Feb 2011
ICS Heat Pump Technology Product Guide Feb 2011
ICS Heat Pump Technology Product Guide Feb 2011
ICS Heat Pump Technology Product Guide Feb 2011
ICS Heat Pump Technology Product Guide Feb 2011
Upcoming SlideShare
Loading in …5
×

ICS Heat Pump Technology Product Guide Feb 2011

2,752
-1

Published on

Brochure containing descriptions and specifications of the DeLonghi Climaveneta range of commercial and domestic heat pumps and related products/technologies.

0 Comments
0 Likes
Statistics
Notes
  • Be the first to comment

  • Be the first to like this

No Downloads
Views
Total Views
2,752
On Slideshare
0
From Embeds
0
Number of Embeds
1
Actions
Shares
0
Downloads
35
Comments
0
Likes
0
Embeds 0
No embeds

No notes for slide

ICS Heat Pump Technology Product Guide Feb 2011

  1. 1. COMMERCIAL HEAT PUMPSRESIDENTIAL HEAT PUMPS
  2. 2. 2 ICS HEAT PUMP TECHNOLOGY DeLonghi-Climaveneta PARTNERSHIP The ICS Group has a strong historical relationship with DeLonghi-Climaveneta, Europe’s leading manufacturer of refrigeration based temperature control equipment. Having built their first Heat Pump units in 1979, DeLonghi-Climaveneta can certainly stake their claim as being one of the most innovative and forward thinking manufacturers of air source heat pumps and ground source/geothermal heat pump over the last thirty years. This well established historical relationship between the ICS Group and DeLonghi-Climaveneta has formed the basis for ICS Heat Pump Technology being selected by DeLonghi-Climaveneta to exclusively provide the DeLonghi Professional range of residential heat pumps and Climaveneta commercial heat pumps throughout the UK and Ireland.
  3. 3. 3CONTENTS ICS DELONGHI-CLIMAVENETA PARTNERSHIP pg 2 DELONGHI-CLIMAVENETA pg 4-5 ICS HEAT PUMP TECHNOLOGY pg 6 ICS APPROVED PARTNER PROGRAMME pg 7 RESIDENTIAL CASE STUDIES pg 8 COMMERCIAL CASE STUDIES pg 9 AIR SOURCE HEAT PUMPS INTRODUCTION pg 10-11 MEDIUM TEMPERATURE HEAT PUMPS pg 12-19 • Bran H Medium Temperature Air Source Heat Pump pg 12-13 • AWR MTD Medium Temperature Air Source Heat Pump pg 14-15 • DHW Twin Medium Temperature Air Source Heat Pump pg 16-17 • MICS-N Medium Temperature Air Source Heat Pump pg 18-19 HIGH TEMPERATURE HEAT PUMPS pg 20-27 • i-KI High Temperature Air Source Heat Pump pg 20-21 • HT 65ºC High Temperature Air Source Heat Pump pg 22-23 • i-NRG High Temperature Air Source Heat Pump pg 24-25 • Prana HT High Temperature Air Source Heat Pump pg 26-27 GROUND SOURCE & GEOTHERMAL HEAT PUMPS INTRODUCTION pg 28-29 • BWR MTD Ground Source & Geothermal Heat Pump pg 30-31 • DHW Twin Ground Source & Geothermal Heat Pump pg 32-33 • Prana MTD Ground Source & Geothermal Heat Pump pg 34-35 • Prana DHW Ground Source & Geothermal Heat Pump pg 36-37 BUFFER TANKS pg 38 DHW CYLINDERS pg 39 FAN COILS & HYDRONICS pg 40-41 APPLICATION & SPECIFICATION SUPPORT pg 42 ACCESSORIES pg 42 TECHNICAL SERVICE SUPPORT pg 43
  4. 4. 4 DeLonghi-Climaveneta PRODUCT INNOVATION RESEARCH & DEVELOPMENT HEAT PUMP FOCUS 40 YEARS EXPERIENCE DeLonghi-Climaveneta is the leading, refrigeration manufacturer in Europe.The company has a worldwide reputation for product reliability and quality with over 35 years of market leading experience. The company has 5 key manufacturing facilities occupying some 52,000 square meters of production space. The company achieves a turnover level in excess of 210 million euros worldwide.
  5. 5. 5A COMPLETE RANGE OF HEATPUMPS FROM 5KW TO 400KW,A BRAND THAT IS SYNONYMOUS WITH RELIABILITY & QUALITY,WITH ALL THE ADVANTAGES THAT ONLYA LEADING MANUFACTURING CAN OFFER.With more than 40 years of experience in air conditioning, DeLonghi-Climaveneta is truly aleading organisation in the expanding domestic, commercial and industrial heat pump market.1ST IN EUROPE & 5TH IN THE WORLDThe mission and values that have guided us for 40 years have enabled us to become the number one manufacturer in Europe and thefifth in the world within the temperature control sector.+ 90,000m² of productive area+ 5 specialist focused manufacturing plants, 4 located in Italy and 1 located in Shanghai China+ Complete range of products from 1kW to 2400kW+ Optimised heat pumps from 5kW to 400kW (modular)+ First heat pump manufactured in 1979+ Now 12 ranges of air source and ground source/geothermal+ Residential and commercial equipment Commercial Heat Pumps Residential Heat Pumps
  6. 6. 6 ICS HEAT PUMP TECHNOLOGY ICS Heat Pump Technology provides a complete service offering design/specification support, supply/commissioning services and after sales support for air source heat pumps, ground source heat pumps and geothermal heat pumps within both the commercial and residential sectors. ICS has been providing temperature control systems and heat transfer equipment for an extensive range of applications and users since 1988. Twenty years of experience has resulted in an extremely well established business operating throughout the UK, Germany and Ireland employing over 200 people with a combined group turnover of circa £30m. PROVEN TECHNOLOGY A COMPANY YOU CAN TRUST • An ICS group company Massive reductions in carbon emissions can be achieved by using heat pumps • Established over 20 years and significant cost savings are possible by increasing the efficiency of a property when a heat pump system is installed. • £30m turnover throughout UK and Europe • Over 200 specialised and highly skilled Ground source or geothermal heat pumps along with air source heat pumps employees take low grade energy from the earth or atmosphere and convert it into high • Excellent reputation in climate control grade heat energy to be used within the property services Whether a new build project or a retrofit application, the range of heat pumps • Provides a complete service provided by Climaveneta and DeLonghi Professional is able to provide a practical • Implements a “best advice” policy to all and cost effective solution to heating and sanitary hot water requirements from customers 5kW to 1200kW.
  7. 7. 7 APPROVED PARTNER PROGRAMME SUPPORT ICS Heat Pump Technology & DeLonghi-Climaveneta provides a specialist support service to their HEAT PUMP customer base, which is designed to assist the heat pump specifier or installer in maximising the fast developing opportunity within the renewable APPROVED PARTNER PROGRAMME heating sector. We understand that providing high quality equipment is only half of the package which is why the ICS Approved Partner Programme (APP) has been developed over the past two and a half years in order to provide the specifier or installer with the complete heat pump support service to accompany the 12 ranges of residential and commercial heat pumps provided by DeLonghi-Climaveneta. The ICS APP is split into 4 main elements each of which provides the specifier or installer with a range of specialist areas to support their business. apptraining apptraining £££ appmarketing appmarketing apptechnical apptechnical appinfocentre appinfocentre• LOGIC ACCREDITED APP • PARTNER BRANDED WEBSITE APP • TECHNICAL SUPPORT DESK APP • CPD APP• PRODUCT DAY APP • SALES/PRODUCT SUPPORT LITERATURE APP • FIELD BASED TECHNICAL SUPPORT APP • INDUSTRY NEWS APP• IN COMPANY SALES & TECHNICAL APP • ICS-DELONGHI NATIONAL MARKETING APP • FACTORY SUPPORT APP • MSC APP• FIELD SUPPORT APP • DIRECT MARKETING/EXHIBITION • INSTALLER/SPECIFIER INTERNET BASED • LEGISLATION APP SUPPORT APP PARTNER HUB APP Commercial Heat Pumps Residential Heat Pumps
  8. 8. 8 CASE STUDIES RESIDENTIAL CASE STUDY NEW BUILD WITH SUBSTANTIAL REFURBISHMENT Property: 5 bedroom 400sq/m high specification low energy house Application: New build with substantial refurbishment Locations: North West Coast Accreditations: MSC Accredited equipment used Installation: ICS Heat Pump Technology Approved Partner Equipment: 1 x DeLonghi Professional i-NRG 16.3kW Inverter Air Source Heat Pump 1 x 200L Buffer Tank 1 x 300L Optimised unvented cylinder 1 x 35L Inertia tank 5 x Climaveneta i-life fan coil terminals 4 x DeLonghi-Climaveneta system/room controllers RESIDENTIAL CASE STUDY BBC DIY SOS LOW COST HOUSING Property: Affordable Housing Application: Refurbishment & New Build Locations: Wales Accreditations: MSC Accredited equipment used Installation: ICS Heat Pump Technology Approved Partner Equipment: 1 x De-Longhi Climaveneta BRAN H 0011 Air Source Heat Pump 1 x Tank In Tank DHW Cylinder 1 x Installation Kit RESIDENTIAL CASE STUDY LARGE NEW BUILD Property: 5 Bedroom Country House Application: New Build Locations: Midlands Accreditations: MSC Accredited equipment used Installation: ICS Heat Pump Technology Approved Partner Equipment: 1 x De-Longhi Climaveneta Z1T17 Cube Ground Source Heat Pump 800m PEX-A Pipework in Horizontal Straight Formation 1 x 300L Twin Coil Heat Pump Cylinder 1 x 100L Buffer Tank
  9. 9. 9COMMERCIAL CASE STUDY NEW BUILD SCHOOLProperty: SchoolApplication: New Build School 90kWLocation: Rural Lancashire TownInstaller: North West based - ICS Approved Partner InstallerEquipment: 1 x BWR DHW 0101 1 x BWR MTD 0101, 2 x 400L Buffer TankCOMMERCIAL CASE STUDY SUPERSTORE HEATING PROJECTProperty: SuperstoreApplication: Space heating - Mono-valent system 360kWLocations: ScotlandAccreditations: MSC Accredited equipment usedInstallation: ICS Heat Pump Technology Approved PartnerEquipment: ICS-Climaveneta 8 x MICS N 0182 Air Source Heat Pumps & 2 x Buffer TanksCOMMERCIAL CASE STUDY AMBULANCE STATION RETROFITProperty: NHS Ambulance StationApplication: Retrofit ‘Off Gas’ Boiler Replacement 20kWLocations: South West EnglandEquipment: 1 x 20kW high temperature 65ºC Climaveneta AW HT Air Source Heat PumpEmitter: RadiatorsCOMMERCIAL CASE STUDY SPACE HEATING & COOLINGProperty: Office & WarehousingApplication: Refurbishment 120kWLocations: North West EnglandAccreditations: MSC Accredited equipment usedInstallation: ICS Heat Pump Technology Approved PartnerEquipment: 2 x De-Longhi Climaveneta DHW Air Source Heat Pumps 1 x De-Longhi Climaveneta MICS-N Air Source Heat Pump 2 x ICS HTP Buffer Tanks Various DeLonghi Climaveneta Fan Coils Various DeLonghi Climaveneta Air Handling Units Commercial Heat Pumps Residential Heat Pumps
  10. 10. 10 AIR SOURCE MEDIUM & HIGH TEMPERATURE HEAT PUMPS MEDIUM TEMPERATURE AIR SOURCE HEAT PUMPS Unit & Hot Heating Simultaneous Cooling Simultaneous Heat Reduced Lower Modular Capacity Water Heating/ (Optional) Cooling, Recovery Carbon Heating Hot Water Hot Water/ Emissions Costs Heating BRAN H 6-14kW HOT WATER HEATING pg 12-13 Residential AWR MTD XE 6-25kW pg 14-15 HOT WATER HEATING COOLING Residential & Commercial DHW Twin 20-33kW HOT WATER HEATING HEATING HEATING + COOLING COOLING COOLING + HOT WATER HOT WATER pg 16-17 Commercial MICS N 20-50kW HEATING COOLING MODULAR pg 18-19 Commercial
  11. 11. 11Our air source heat pumps provide a very efficient means of utilising renewable energywhilst being very straightforward in their installation.The DeLonghi-Climaveneta range of air source heat pumps provides units withcapacities from 5kW to 200kW which are suitable for a wide range of applications.Single phase 240v powered air source heat pump units are available up to a capacityof 14kW and three phase 415v units complete the range for larger residential heatpump and commercial applications.Modular capability allows for the multiple connection of up to six units operating asone single package, hence large capacity projects can be specified by utilising this AIR SOURCE HEAT PUMPSmodular configuration approach. The single controller ensures that running hours are Heat energy is collected from the external ambient airequalised & maintained across the various heat pumps whilst also ensuring that the using the heat pumps integral evaporator coil. This energy is then transferred as high grade heat into the building.system operates with maximum modular part load efficiency at all times.HIGH TEMPERATURE HEAT PUMP DESIGNATION MEANS THE UNIT IS DESIGNED TO DELIVER A 60ºC OUTPUT TEMPERATURE AT A -5ºC AMBIENT CONDITION HIGH TEMPERATURE AIR SOURCE HEAT PUMPS Unit & Hot Heating Simultaneous Cooling Simultaneous Heat Reduced Lower Modular Capacity Water Heating/ (Optional) Cooling, Recovery Carbon Heating Hot Water Hot Water/ Emissions Costs Heating i-KI 9.5kW HOT WATER HEATING MODULAR pg 20-21 Residential HT 65ºC 10-27kW pg 22-23 HOT WATER HEATING MODULAR Residential & Commercial i-NRG 16.3kW HOT WATER HEATING HEATING HEATING + COOLING COOLING COOLING + MODULAR HOT WATER HOT WATER pg 24-25 Residential PRANA HT 40-100kW HOT WATER HEATING COOLING MODULAR pg 26-27 Commercial Commercial Heat Pumps Residential Heat Pumps
  12. 12. 12 Bran H Unit Description HEATING HOT WATER The DeLonghi Prana Bran H range of air source heat pumps provide a high level of performance along with a high level of specification but in a very cost effective package. • The nominal refrigeration COP* (efficiency) of these units is high averaging over 4.0 but importantly the performance of these units when operating in lower ambient temperatures is also at a high level. Designed to operate in ambient temperatures as low as -15ºC the Bran H range is more than capable of operating in UK & Irish winter temperatures. • These units incorporate a built in heating system circulation pump, control for hot water production including Y Plan valve (optional, not supplied as standard) operation along with full weather compensation and controls which give a very short defrost cycle in lower ambient temperatures. • The Bran H range will operate with a standard 2 channel time clock or programmable room stat, please contact technical support for clarification or specification details. • The Bran H range will function with any heat pump optimised DHW cylinder allowing flexibility in terms of stored water volume to match the demands of each particular project. Unit Summary • This advanced control means that these units are able to operate with BRAN H UNITS: AW very low system volumes, a minimum open circuit volume of 3.5 litres CAPACITY: 6kW-14kW per nominal kW of heat pump capacity is required which can reduce installation costs considerably. A buffer tank is recommended to POWER SUPPLY: Single Phase models achieve maximum operational efficiency in order to provide thermal mass and efficient defrost capability. A cost effective high specification air source solution providing heating and hot water up to 55ºC output temperature (50ºC at • These DeLonghi-Climaveneta units are high specification heat pumps -3ºC ambient) which are built to exacting standards with regard to efficiency and functionality. All the units are European manufactured and benefit from HIGH EFFICIENCY & PERFORMANCE: COP 4.01 (401% efficient) the DeLonghi-Climaveneta approach to product development and quality management providing the complete package that would be *Average coefficient of performance (COP) for the Bran H range based on an ambient temperature of 7ºC and 35ºC flow temperature expected from a premier manufacturer. COP 3.6 (360% efficient @ 2ºC ambient & 35ºC flow temp) NOTE. Actual system efficiency (COP) and annual performance will depend on the distribution/emiiter system utilised. Care should be taken to ensure that the heat pump is installed in order to provide efficient operational performance. AXIAL FEATURES & OPERATIONAL BENEFITS: *(COP is shown without circulation pump input power. Please note that unlike most other heat • MSC accredited heat pumps, certificate HP0005 pumps these units incorporate built in circulation pumps, therefore by not including the circulation pump input power we are able to provide a direct performance comparison with other units). • Cost effective • High efficiency • Full DHW and heating control • Built in circulation pump • Microgeneration scheme accreditation allows • High COP access to grant funding and also guarantees performance and manufacturing quality. • Full floating control for high efficiency & minimum defrost Certificate Number MSC HP0005 time to -15°C ambients Heat Pumps
  13. 13. 13 Bran H Air Source Medium Temperature Heat PumpsMain Components• Condensate drain pan kit. • The electronic controller menu allows management of:• Condensing coil protection grills - circulation pump on the system side - domestic hot water production via control of the external three-way• Housing and base are made from hot-galvanized epoxy powder coated valve (not supplied) sheet metal - 24 hour timer operation for a cylinder heater• High efficiency and low pressure drop stainless steel (AISI 316) water - control of the incorporated supplementary heating element exchangers, with anti-freeze heating element and differential pressure - outdoor temperature sensor for modulating set point weather switch compensation• Hermetic scroll type compressors, equipped with the crankcase heater • Soft start for 230V/1/50Hz units (45 amps & 25 amps for the 0011 and thermal protection model)• Condensers finned tubes with copper and aluminium fins high exchange • Phase sequence control relay surface (100% fully quality tested); sub cooling circuit to prevent freezing • The water circuit comes complete with: at the base. - variable flow circulation pump for all models• Axial electric fans, external rotor, electric motor with a 6-pole fitted with - differential pressure switch on plant side thermal protection, housed in an aerodynamic profile with safety grill - expansion vessel (Heat Pump circuit only)• Low external air temperature device: - safety valve - fan speed regulation with pressure switch which maximises - manual filling assembly- pressure gauge- manual air vent valve efficiency at part load NB: Optional equipment includes a range of tanks & cylinders plus• Electrical modulating frost protection heating within the base which standard installation packs, see current price list or contact ICS HPT or your minimizes the risk of condensate freezing during periods of low ambient distributor for details. temperatureBran H 0011M 0025M 0041MHeating capacity (1) kW 6.5 8.7 13.8Effective input power according to EN 14511 (1) kW 1.82 2.31 3.68Heating capacity (2) kW 6.5 8.7 13.8Power absorbed (2) kW 1.65 2.15 3.40COP* (2) 3.94 4.05 4.06Rated water flow (1) m3/h 1.12 1.50 2.37Residual head (1) kPa 41 48 89Fans n0 1 1 2Air flow m3/s 0.9 1 1.9Type of compressor ScrollNo. of compressors n0 1 1 1No. of circuits n0 1 1 1Refrigerant R410A kg 1.75 3 3Oil Mobil EAL ARTIC 22cc kg 1.1 1.24 1.95Pump type circulatorNo. of pumps n0 1 1 1Functioning weight kg 95 115 140Hydraulic connections inches 3/4 3/4 1 1/4Sound pressure level according to EN ISO 3744 dB(A) 72 73 73Sound pressure (3) db(A) 58 59 59Electric power supply V/ph/Hz 230-510Common Data 0011 0025 0041Circulation pump IncludedDHW control IncludedHeight/Length/Width mm 640/900/370 940/900/370 1240/900/370Weight kg 105 130 160 LNote:1. Heat pump mode: external air temperature 7°C DB/6°C WB, water in flow at 30°C and outlet at 35°C H2. The total input is given by the compressor input and fans power input3. Free field sound pressure on a reflecting surface (directivity fact. Q=2), at a distance of 1 meters H from the external surface of the unit. Average value calculated from the sound power W L WICS Renewable Energy Ltd (T/A ICS Heat Pump Technology) and/or Climaveneta S.p.A (DeLonghi) reserve the right to change update or alter the specification & details of any item shown with or withoutprior notice for whatever reason. The information provided within the product guide and/or data sheets is intended for guidance purposes only, please confirm actual current specification and equipmentdetails at point of quotation and/or order. Residential Heat Pumps
  14. 14. 14 AWR MTD XE Unit Description HEATING COOLING HOT WATER The DeLonghi Prana AWR MTD XE range of air source heat pumps provide an extremely high level of performance and a high level of specification. The nominal refrigeration COP* (efficiency) of these units is very high averaging over 4.17 and importantly the performance of these units when operating in lower ambient temperatures is also at a very high level. Designed to operate in ambient temperatures as low as -15ºC the AWR MTD XE range is more than capable of operating with high efficiency in UK & Irish winter temperatures. • These units incorporate a built in heating system circulation pump, control for hot water production including Y Plan valve (optional, not supplied as standard) operation along with full weather compensation and sophisticated controls which give a very short defrost cycle in lower ambient temperatures. • The AWR MTD range will operate with a standard 2 channel time clock or programmable room stat, please contact technical support for clarification or specification details. • A modulating source fan controls efficiency and maximises the performance on part loads by drawing the correct amount of air through the unit to match the load requirement of the property at any time, so reduces running costs and also allows the units to function with any Heat Pump optimised thermal store or cylinder. Unit Summary • This advanced control means that these units are able to operate with very low system volumes, a minimum open circuit volume of 3.5 litres MTD UNITS: AWR MTD XE per nominal kW of Heat Pump capacity is required which can reduce CAPACITY: 6kW-25kW installation costs considerably. A buffer tank is recommended to achieve maximum operational efficiency in order to provide thermal POWER SUPPLY: Single Phase & Three Phase models mass and efficient defrost capability. These units can provide heating or cooling and hot water up to 55ºC, the efficient unit design incorporating supplementary • In addition to these features these units also have a built in heating enables the AWR MTD XE to operate efficiently in low supplementary heater which provides additional capacity in ambient ambient conditions to -15ºC. temperatures below -5ºC. HIGH EFFICIENCY & PERFORMANCE: COP 4.17 (417% efficient) • These units also provide reversible operation, this means they can *Average coefficient of performance (COP) for the AWR MTD XE range based on an provide cooling whilst being able to prioritise hot water production, ambient temperature of 7ºC and 35ºC flow temperature. this means that when connected via a fan coil distribution system these NOTE. Actual system efficiency (COP) and annual performance will depend on the AWR MTD units can provide a complete residential or light commercial distribution/emiiter system utilised. Care should be taken to ensure that the heat pump is installed climate control option. in order to provide efficient operational performance. • These DeLonghi-Climaveneta units are high specification heat pumps FEATURES & OPERATIONAL BENEFITS: which are built to exacting standards with regard to efficiency and • MSC accredited heat pumps (AWR MTD XE accreditation pending) functionality. All the units are European manufactured and benefit from the DeLonghi-Climaveneta approach to product development and • Full DHW and heating control quality management providing the complete package that would be • Reversible operation can provide cooling for A/C applications expected from a premier manufacturer. • Built in circulation pump • 55ºC output temperature (50ºC at -5ºC ambient) • High efficiency modulating source fan(s) and circulation pump AXIAL • Minimum defrost time operating to -15ºC ambients • Supplementary Electric Heating Included for -5ºC ambient *(COP is shown without circulation pump input power. Please note that unlike most other heat operation pumps these units incorporate built in circulation pumps, therefore by not including the circulation pump input power we are able to provide a direct performance comparison with other units).
  15. 15. 15 MTD XE Air Source Medium Temperature Heat PumpsMain Components• Condensate drain pan kit. • Soft start for 230V/1/50Hz units (45 amps)• Condensing coil protection grills • Reversible operation allows the production of chilled water for an• Housing and base are made from hot-galvanized epoxy powder coated sheet air-conditioning circuit metal • The electronic controller menu allows management of:• High efficiency and low pressure drop stainless steel (AISI 316) water - circulation pump on the system side exchangers, with anti-freeze heating element and differential pressure switch - domestic hot water production via control of the external three-way valve• Hermetic scroll type compressors, equipped with the crankcase heater and (not supplied) thermal protection - 24 hour timer operation for a cylinder heater• Condensers finned tubes with copper and aluminium fins high exchange - control of the incorporated supplementary heating element surface (100% fully quality tested); sub cooling circuit to prevent freezing at - outdoor temperature sensor for modulating set point weather the base. compensation• Axial electric fans, external rotor, electric motor with a 6-pole fitted with • Phase sequence control relay thermal protection, housed in an aerodynamic profile with safety grill • The water circuit comes complete with:• Low external air temperature device: - variable flow circulation pump for all models - fan speed regulation with pressure switch which maximises efficiency at - differential pressure switch on plant side part load - expansion vessel (Heat Pump circuit only)• Electrical modulating frost protection heating within the base which minimises - safety valve the risk of condensate freezing during periods of low ambient temperature - manual filling assembly- pressure gauge- manual air vent valveNB: Optional equipment includes a range of tanks & cylinders plus standard installation packs, see current price list or contact ICS HPT or your distributor for details.AWR-MTD XE 0011MS 0025MS 0031MS 0041MS 0031T 0041T 0051T 0061T 0091TNominal heating power (1) kW 6.30 7.40 11.2 14 10.9 14 15.9 17.9 25.10Total absorbed power (2) kW 1.50 1.80 2.60 3.30 2.60 3.30 3.80 4.20 6COP 4.13 4.15 4.22 4.16 4.15 4.15 4.11 4.25 4.19Cooling capacity (3) kW 7.20 8.30 12.3 15.7 11.7 15.8 17.7 20.2 29.2Total absorbed power (2) kW 1.90 2.20 3.30 4.10 3.10 4.20 4.70 5.30 7.80EER Eurovent * 3.79 3.77 3.73 3.83 3.77 3.76 3.77 3.81 3.74EER 3.82 3.82 3.81 3.84 3.84 3.81 3.81 3.81 3.85Heating capacity (4) kW 6.10 7.30 10.8 13.6 10.6 13.8 15.4 17.5 24.60Total absorbed power (2) kW 1.90 2.30 3.30 4.10 3.20 4.30 4.60 5.20 7.40Cooling capacity (5) kW 5.20 6.30 9.20 11.7 8.60 11.9 13.2 15.2 22.10Total absorbed power (2) kW 1.70 2.20 3.10 4.00 3.00 4.00 4.60 5.00 7.20EER Eurovent * 3.06 2.86 2.97 2.93 2.87 2.98 2.87 3.04 3.07ESEER 3.62 3.63 3.52 3.46 3.42 3.65 3.24 3.55 3.57Compressor type SCROLLN. Compressors N. 1Refrigerant R410AN. fans N. 1 1 2 2 2 2 2 2 3Plant side pump type (6) Ci Ci Ci Ci Ci Ci Ci Ci CiElectrical power supply V-Ph~Hz 230-1~50 230-1~50 230-1~50 230-1~50 400-3N~50 400-3N~50 400-3N~50 400-3N~50 400-3N~50Start-up current A 27 30 45 45 48 64 64 75 111Sound power (7) dB(A) 69 69 71 71 71 71 71 72 74Sound pressure (8) dB(A) 54 54 56 56 56 56 56 57 58L mm 900 900 900 900 900 900 900 1550 1550H mm 1240 1240 1240 1390 1240 1390 1390 1200 1700W mm 420 420 420 420 420 420 420 450 450Operational weight kg 145 150 155 170 155 170 180 250 335 LNote:1. Water in-out 30/35°C (plant side), outdoor air temperature 7°C b.s./ 6°C b.u.2. Total input is obtained from compressor input and fan input3. Water in-out 23/18°C (plant side), outdoor air temperature 35°C b.s.4. Water in-out 40/45°C (plant side), outdoor air temperature 7°C b.s./ 6°C b.u. H5. Water in-out 12/7°C (plant side), outdoor air temperature 35°C b.s.6. Ci=Circulator; Ce=Centrifugal H7. Sound power level according to ISO 9614 and Eurovent 8/18. Average sound pressure level above one reflecting surface (Q=2) at 1 meter from the outside dimensions of the unit.* According to the Eurovent standard without circulation pump input power. W L WICS Renewable Energy Ltd (T/A ICS Heat Pump Technology) and/or Climaveneta S.p.A (DeLonghi) reserve the rightto change update or alter the specification & details of any item shown with or without prior notice for whateverreason. The information provided within the product guide and/or data sheets is intended for guidance purposesonly, please confirm actual current specification and equipment details at point of quotation and/or order. Commercial Heat Pumps Residential Heat Pumps
  16. 16. 16 DHW Twin Unit Description HEATING + COOLING + HEATING HEATING COOLING COOLING HOT WATER HOT WATER HOT WATER The DeLonghi Prana AWR DHW are a unique range of commercial air source heat pumps which are capable of providing a high efficiency combination of output conditions: • Heating only • Simultaneous heating and hot water to 55ºC** • Hot water only • Cooling only • Simultaneous cooling and hot water with up to 100% heat recovery*** • Simultaneous cooling and heating with up to 100% heat recovery*** These units can be specified to suit a particular application and due to their ability in being able to provide two simultaneous outputs they are able to provide real benefits on both large residential and commercial applications. Within the commercial sector the AWR DHW range provides flexibility and real environmental benefits. These Heat Pumps will provide up to 100% heat recovery which then benefits the user with free heating or hot water. A growing demand for energy and heat recovery has created a highly efficient requirement to use these units to recover waste energy from waste water or fluid flows, recovering energy from cooling towers or waste water flows is easily achievable when utilising these units in heat recovery specification. Also these heat pump units will provide up to 100% duty on either primary or secondary heat exchangers along with the ability to provide a combination of heating and hot water simultaneously or heating and cooling simultaneously with up to 100% heat recovery. This allows these heat pump units to provide this simultaneous output feature to manage seasonal heating and cooling loads from the same heat pump unit***. Unit Summary These DeLonghi-Climaveneta units are high specification heat pumps which are built to exacting standards with regard to efficiency and DHW TWIN UNITS: AWR functionality. All the units are European manufactured and benefit from the DeLonghi-Climaveneta approach to product development and quality CAPACITY: 20kW-33kW management providing the complete package that would be expected POWER SUPPLY: Single Phase & Three Phase models from a premier manufacturer. These units provide simultaneous supplies of domestic hot r HFC r HFC water and heating/air conditioning. AXIAL R-410A AXIAL R-410A HIGH EFFICIENCY & PERFORMANCE: COP 3.87 (387% efficient) *(COP is shown without circulation pump input power. Please note that unlike most other heat pumps these units incorporate built in circulation pumps, therefore by not including the circulation *Average coefficient of performance (COP) for the AWR DHW range based on an pump input power we are able to provide a direct performance comparison with other units). ambient temperature of 7ºC and 35ºC flow temperature **A higher temperature DHW output is available when the unit is operating in heating mode. NOTE. Actual system efficiency (COP) and annual performance will depend on the The actual available capacity of DHW is dependent on the heating output being provided at any distribution/emiiter system utilised. Care should be taken to ensure that the heat pump is installed time. The available part load DHW capacity will vary dependant on the part load capacity in order to provide efficient operational performance. available in-line with the above. FEATURES & OPERATIONAL BENEFITS: ***The AWR DHW range of units are designed to provide simultaneous heating/DHW and cooling when operating in ambient temperatures above 10ºC unless a year round cooling load is • MSC accredited heat pumps, certificate HP0005 available. Please contact ICS Heat Pump Technology Technical Support to confirm the suitability of this range of equipment for each application. • Fully self-contained unit – no external refrigerant pipes • Standard pipe work installation to suit a plumber or heating engineer • Highly efficient and flexible design with easy to use controls • Microgeneration scheme accreditation allows • Heating, cooling and domestic hot water provided access to grant funding and also guarantees • Suitable for large capacity hot water users and simultaneous performance and manufacturing quality. heating & air conditioning applications Certificate Number MSC HP0005 Heat Pumps Commercial Heat Pumps
  17. 17. 17 DHW Twin Air Source Medium Temperature Heat PumpsMain Components• Housing and base are made from hot-galvanized epoxy powder coated sheet metal • Secondary stainless steel plate heat exchanger providing an output kW capacity• Hermetic scroll type compressors, equipped with the crankcase heater and up to 100% of the heat pump duty with high efficiency and low pressure drop thermal protection provides the supply of both hot or cold water for the application with or without any hot water or heating production on the primary heat exchanger.• Condensers finned tubes with copper and aluminium fins high exchange surface (100% fully quality tested); sub cooling circuit to prevent the icing at the base • The water circuit comes complete with: - primary circuit water pump for domestic hot water or heating circuit• Axial electric fans, external rotor, electric motor with a 6-pole fitted with thermal protection, housed in aerodynamic profile with safety grill. - secondary circuit plant side water pump for heating or cooling circuit - differential pressure switch on plant side - continuous fan speed regulation with pressure switch for modulating load management - expansion vessel Heat Pump circuit only - safety valve (6 bar)• Primary stainless steel (AISI 316) plate heat exchanger with high efficiency and - manual filling assembly low pressure drop (providing domestic hot water or heating) positioned directly - Pressure gauge after the compressor which gives an efficient high temperature output providing an output kW capacity up to 100% of the Heat Pump duty. - venting and draining valve• When combined with the secondary heat exchanger (cooling duty) these units • Soft start for 230V/1/50Hz units AWR DHW/S will provide either full or partial heat recovery which is constantly optimised NB: Optional equipment includes a range of tanks & cylinders plus standard via the advanced logic adjusting controller. installation packs, see current price list or contact ICS HPT or your distributor for details. Prioritised hot water production in simultaneous DHW & heating mode Partial or 100% heat recovery available in simultaneous cooling & heating mode HEATING + DOMESTIC HOT WATER** HEATING + AIR CONDITIONING***AWR DHW 0065SL 0101SLHeating capacity (A7/W35) (1) kW 21.3 33.5Total power input (compressors & fans) kW 5.6 8.5COP* 3.80 3.94Recovery heating capacity (A7/W50) (2) kW 18.1 31.9Power input kW 7.7 12.3COP* 2.35 2.59Cooling Capacity (A35/W18) (3) kW 21.1 33.0Total power input (compressors & fans) kW 5.8 9.4EER* 3.64 3.51Cooling Capacity (A35/W7) (4) kW 17.0 27.7Total power input (compressors & fans) kW 5.9 9.5EER* 2.88 2.92Type of compressor scrollN.° of compressors n° 1Refrigerant R407CPlant side pump type centrifugalDHW side pump type circulatorPower supply V/Ph/Hz 400V-3N~ 50HzStarting current A 127 101Sound pressure (5) dB(A) 66 62Height/Length/Width mm 1200/1700/650 1700/1700/650Net weight kg 295 378 LNote:1. Heating mode: external air temperature 7°C b.s.- 6°C b.u.,inlet water at 30°C and outlet at 35°C2. Heating mode: external air temperature 7°C b.s.- 6°C b.u.,inlet water at 45°C and outlet at 50°C3. Cooling mode: external air temperature 35°C b.s., inlet water at 23°C and outlet at 18°C4. Cooling mode: external air temperature 35°C b.s., inlet water at 12°C and outlet at 7°C H5. Sound pressure at 1 meter distance from the external surface of the unit, free field.* According to the Eurovent standard without circulation pump input power.ICS Renewable Energy Ltd (T/A ICS Heat Pump Technology) and/or Climaveneta S.p.A (DeLonghi) reserve the right to change update or alter the specification & details of any item shown with or withoutprior notice for whatever reason. The information provided within the product guide and/or data sheets is intended for guidance purposes only, please confirm actual current specification and equipment Wdetails at point of quotation and/or order.
  18. 18. 18 MICS-N Unit Description HEATING COOLING MODULAR SUITABLE FOR SWIMMING POOLS The Climaveneta MICS-N commercial heat pump range provides a fully optimised Air Source Heat Pump installation with the capability to provide a modular package in excess of 200kW in capacity which operates as a single unit. This provides a very high specification air source installation for both large residential and commercial applications. • A high COP is achieved at nominal conditions with a high performance and specification designed for medium temperature heating only. • These units have twin compressors for maximum efficiency when operating on partial load duty. They also have the ability to operate with four heat pumps acting as a single unit i.e. three slaves and one master where the lead unit will interface with a BMS system or equivalent. • These units are reversible and provide heating or cooling to match the demands of the project. • Each MICS-N single unit incorporates a twin compressor design which provides a highly efficient output when operating under part load conditions i.e. in modular multi unit/multi compressor configuration. ***modular capability • Circulation pumps are incorporated within the unit to give a complete installed solution with a high specification and highly efficient system. Unit Summary The full floating control and modulating performance of the system provides a highly intelligent control function to give maximum MICS-N UNITS: AWR performance and efficiency. CAPACITY: 20kW-50kW (modular parallel systems) POWER SUPPLY: Three Phase models • The units also incorporate a vertical air discharge system which allows for compact positioning of single or multiple units to fit into restricted These units provide medium to large capacity installations with a high locations. efficiency modular system which can provide heating and air conditioning from 20kW to 1000kW (modular). • These DeLonghi-Climaveneta units are high specification heat pumps which are built to exacting standards with regard to efficiency and HIGH EFFICIENCY & PERFORMANCE: COP 3.85 (385% efficient) functionality. All the units are European manufactured and benefit from *Average coefficient of performance (COP) for the MICS-N range based on an ambient the DeLonghi-Climaveneta approach to product development and temperature of 7ºC and 35ºC flow temperature. quality management providing the complete package that would be COP 3.77 (377% efficient @ 2ºC ambient & 35ºC flow temp) expected from a premier manufacturer. NOTE. Actual system efficiency (COP) and annual performance will depend on the distribution/emiiter system utilised. Care should be taken to ensure that the heat pump is installed in order to provide efficient NB: Optional equipment includes a range of tanks & cylinders plus operational performance. standard installation packs, see current price list or contact ICS HPT or your FEATURES & OPERATIONAL BENEFITS: distributor for details. • MSC accredited heat pumps, certificate HP0005 r HFC r HFC • Provides heating & cooling with a number of control options AXIAL R-410A AXIAL R-410A • Full BMS compatability with single control function for multiple units *(COP is shown without circulation pump input power. Please note that unlike most other heat • Modular system which provides flexibility and ease of installation pumps these units incorporate built in circulation pumps, therefore by not including the circulation • Vertical discharge fan with compact footprint for ease of positioning pump input power we are able to provide a direct performance comparison with other units). • Very efficient twin compressor design provides high part load efficiency when providing heating and cooling on an annual basis • Fully self-contained unit – no external refrigerant pipes • Water based system which allows the heating and A/C installation to • Microgeneration scheme accreditation allows be carried out by a mechanical contractor Access to grant funding and also guarantees Performance and manufacturing quality. • Highly efficient and flexible design which can be specified as a Certificate Number MSC HP0005 package with fan coils/internal air handlers Heat Pumps

×