0
flow measurement
Presentation Overview
1.Flow meter technology
2.Positive Displacement - Principle of operation.
3.Ideal applications
4.Wha...
Flowmeter Technologies
There are 4 general groupings by which a flow meter can
be categorised, according to the technology...
Volumetric Flowmeter
‘Directly measure the total volume of the fluid passing
through the pipe’







Oval Gear
Rota...
Typical Applications
Volumetric
•
•
•
•
•

Batching
Dispensing
Dosing
Fuel Consumption
Applications requiring accurate
tot...
Positive Displacement
Flowmeter
Principle of Operation
A precision engineered
measuring chamber
houses a pair of oval rotors
which rotate during flow
cond...
Principle of Operation
As the Rotors turn they sweep a measured volume of
liquid through the measuring chamber
Measured Vo...
Principle of Operation
• Each of the Rotors are
fitted with magnets on the
top face.
• As the Rotor turns the
magnet activ...
Principle of Operation
Our Sensor Boards (PCB)
incorporate two types of switches.
 Reed Switch
Mechanical Switch

 Hall ...
Calculating Flow Rate
• The K- Factor is … ‘The number of Sensor Pulses per Unit of
Measure’ (Litre or US gallon)
• Each m...
The Benefits associated
with a PD Meter
Technical Specifications
 Accuracy
• +/- 0.5%

(500ml in every 100 litres)

 Repeatability
• 0.03%

(30ml in every 100 l...
Installation and Commissioning
 Reliable
 Robust
 Easily maintained on site
 No pipe conditioning required
 Suitable ...
Suitable Applications
Ideal Applications
Dispensing
 Refuelling
 Vehicle Servicing
 Drum Filling
 Chemical Packaging

Positive Displacement ...
Servicing and Transfer
Diesel Service Truck
Diesel Service Truck
Diesel Service Truck
Ideal Applications
Batching
 Chemical Dilution and Packaging
 Food / Baking
 Animal Feed

Flow Measurement Technology
Automatic Batching
Automatic Filling System
Multiple Drum Filling
Portable Batching System
New application – AdBlue metering
Fuel Consumption System
Recirculation Fuel System - Meter Installation - Schematic
Receiving
Instrument

Master
Fuel
Filte...
Ideal Applications
High Viscosity






Fuels and Lubricants
Paints and Coatings
Adhesives
Printing Ink
Cleaning Chem...
Agricultural Dispensing
What’s New?
The new MX Flowmeter series
 Pulser range only
 Manufactured from solid Billet
(St.St and Aluminium)
 Increased Temp (1...
M-Lock™ mounting system
We have developed a new ¼”
turn (Bayonet fitting) mounting
system for our Pulse Output and
Display...
Approved for Hazardous Areas
 Intrinsically Safe (Ex ia)
 Flameproof (Exd)
 Approved ATEX,
 Approved IECEx pending
*No...
Online Resources
Macnaught has developed a comprehensive set of
web based resources in order to support customers
througho...
Interactive Web Tools
 Automated Flowmeter Selection Tool
 Specifications Tool
 Conversion Tool (coming soon)
Online Information
General web based resources
Quick Reference Guides
General Specifications
3D Drawings
Instruction M...
Marketing Resources
MX Demo Kit
We have developed an MX
Demonstration Kit to compliment
the launch of the MX series.
tabl...
Overview of the new
generation MX Series
Flowmeter Range overview
 The range consists of over
1,000 flowmeter models.
 Process Connection sizes
range from ¼” to ...
Range Segmentation
Application Based Focused on Ideal applications
1. Fuel and Oil
2. Solvent
3. Industrial

All Inclusive...
MX part numbering
convention
MX25F-1SA
Breakdown of the part numbering system

Part Number
MX25F-1SA
Breakdown of the part numbering system
MX … Flowmeter Series

Part Number
MX25F-1SA
Breakdown of the part numbering system
MX … Flowmeter Series
25 … Size and Flow Range

Part Number
MX25F-1SA
F
Breakdown of the part numbering system
MX … Flowmeter Series
25 … Size and Flow Range
F

… Industry Type or Fa...
MX25F-1SA
Breakdown of the part numbering system
MX … Flowmeter Series
25 … Size and Flow Range
F … Industry Type or Famil...
MX25F-1SA
Breakdown of the part numbering system
MX … Flowmeter Series
25 … Size and Flow Range
F … Industry Type or Famil...
MX25F-1SA
Breakdown of the part numbering system
MX … Flowmeter Series
25 … Size and Flow Range
F … Industry Type or Famil...
MX25F-1SA
Size and Flow Range
Model No. (mm)

Size

Flow Range

MX06

¼”

0.5 – 100 l/hr

MX09

¼”

15 – 500 l/hr

MX12

½...
MX25F-1SA
Industry Type or Family
Fuel and Oil (F)

Solvents (S)

Industrial (P)

• Al meter body
• PPS rotors
• Viton Sea...
MX25F-1SA
Port Style (process connection)
1.
2.
3.
4.
5.

BSP (Rp)
NPT
ANSI 150lb
JIS 10K
DIN PN16
MX25F-1SA
Rotor Type
Fuel and Oil series
S = PPS Rotors
Solvent series
S = Models MX06 - MX025
Models MX40 – MX100

Stainl...
MX25F-1SA
Display or Pulser Output Modules
A
B
C
D
E
F
G
H
T

Standard Pulse
Intrinsically Safe (Ex ia)
Flameproof (Ex d)
...
Pulser Output and
Display Modules
Type A

Compact
Compact
•
•
•
•
•

Polypropylene Housing
IP 67
Pulser Output
1x Reed switch
1x Hall Effect (NPN)
Type B

Approved Ex ia
Intrinsically Safe
•
•
•
•
•
•
•
•

Stainless Steel
Pulser Output
NPN Open Collector
Approved Ex ia...
Type C

Approved Exd
Flameproof
•
•
•
•
•
•

Stainless Steel
Pulser Output
NPN Open Collector
Approved Exd
ATEX
IECEx pend...
Type D

PR Digital Display
Display
•
•
•
•
•
•
•

Meter Mount or Wall Mount
Polypropylene Housing IP67
7 Digit – 12mm uppe...
Type E

PRA Digital Display
Display
•
•
•
•
•
•
•

Meter Mount or Wall Mount
Polypropylene Housing IP67
7 Digit – 12mm upp...
Type F

ER Digital Display
Display
•
•
•
•
•
•
•

Meter Mount or Remote Mount
Aluminium housing IP 67
7 Digit – 17mm upper...
Type G

ERA Digital Display
Display
•
•
•
•
•
•
•

Meter Mount or Remote Mount
Aluminium housing IP 67
7 Digit – 17mm uppe...
Type H

ERB Batch Controller
Display
•
•
•
•
•
•
•

Meter Mount or Remote Mount
Aluminium housing IP 67
7 Digit – 17mm upp...
Type T

High Temperature
Intrinsically Safe
•
•
•
•

Stainless Steel
Pulser Output
NPN Open Collector
Max temp 150oC
ERS Digital Register
Summation / Differential
Display
•
•
•
•
•
•
•

Remote Mount only
Aluminium housing IP 67
7 Digit – 1...
Accessories
Flanged Process Connections
• Flanges are now screwed into the Meter body
• Available in ANSI, DIN, JIS
Wall M...
End Presentation
Upcoming SlideShare
Loading in...5
×

Distributor presentation mx

641

Published on

Introduction to the new Macnaught MX Series Flowmeters

Published in: Technology, Business
0 Comments
0 Likes
Statistics
Notes
  • Be the first to comment

  • Be the first to like this

No Downloads
Views
Total Views
641
On Slideshare
0
From Embeds
0
Number of Embeds
0
Actions
Shares
0
Downloads
24
Comments
0
Likes
0
Embeds 0
No embeds

No notes for slide

Transcript of "Distributor presentation mx"

  1. 1. flow measurement
  2. 2. Presentation Overview 1.Flow meter technology 2.Positive Displacement - Principle of operation. 3.Ideal applications 4.What's new 5.Introducing the new generation MX series Flowmeters.
  3. 3. Flowmeter Technologies There are 4 general groupings by which a flow meter can be categorised, according to the technology adopted.  Velocity  Inferential  Mass  Volumetric Flow Measurement Technology
  4. 4. Volumetric Flowmeter ‘Directly measure the total volume of the fluid passing through the pipe’       Oval Gear Rotary Nutating Disc Bi-Rotor Spur Gear Oscillating Piston Flow Measurement Technology
  5. 5. Typical Applications Volumetric • • • • • Batching Dispensing Dosing Fuel Consumption Applications requiring accurate totals Flow Measurement Technology
  6. 6. Positive Displacement Flowmeter
  7. 7. Principle of Operation A precision engineered measuring chamber houses a pair of oval rotors which rotate during flow conditions Meter Construction
  8. 8. Principle of Operation As the Rotors turn they sweep a measured volume of liquid through the measuring chamber Measured Volume Measuring Chamber
  9. 9. Principle of Operation • Each of the Rotors are fitted with magnets on the top face. • As the Rotor turns the magnet activates a switch which is fixed to a Printed Circuit Board (PCB) • This in turn generates a Pulse Output
  10. 10. Principle of Operation Our Sensor Boards (PCB) incorporate two types of switches.  Reed Switch Mechanical Switch  Hall Effect Switch Solid State Electronics – Printed Circuit Board
  11. 11. Calculating Flow Rate • The K- Factor is … ‘The number of Sensor Pulses per Unit of Measure’ (Litre or US gallon) • Each meter is assigned an individual K-Factor calculated during our calibration checks Example ….  A meter has an independent K-Factor 36 (= 36 pulses per litre)  Each pulse generated by the meter is the equivalent to 1 Ltr ÷ 36 = 27.8 ml  An Electronic device (Signal Conditioner) is used to convert these pulse outputs to Flow Rate and Total Flow K-Factor
  12. 12. The Benefits associated with a PD Meter
  13. 13. Technical Specifications  Accuracy • +/- 0.5% (500ml in every 100 litres)  Repeatability • 0.03% (30ml in every 100 litres) Flow Measurement Technology
  14. 14. Installation and Commissioning  Reliable  Robust  Easily maintained on site  No pipe conditioning required  Suitable for variations in medium (e.g. viscosity, concentrations, etc. ) Flow Measurement Technology
  15. 15. Suitable Applications
  16. 16. Ideal Applications Dispensing  Refuelling  Vehicle Servicing  Drum Filling  Chemical Packaging Positive Displacement Flow Meters
  17. 17. Servicing and Transfer
  18. 18. Diesel Service Truck
  19. 19. Diesel Service Truck
  20. 20. Diesel Service Truck
  21. 21. Ideal Applications Batching  Chemical Dilution and Packaging  Food / Baking  Animal Feed Flow Measurement Technology
  22. 22. Automatic Batching
  23. 23. Automatic Filling System
  24. 24. Multiple Drum Filling
  25. 25. Portable Batching System
  26. 26. New application – AdBlue metering
  27. 27. Fuel Consumption System Recirculation Fuel System - Meter Installation - Schematic Receiving Instrument Master Fuel Filter Fi lte r Fuel Tank NonReturn Valve Fuel Consumption calculated as Meter P1 Meter P2 Meter P1 Engine Meter P2
  28. 28. Ideal Applications High Viscosity      Fuels and Lubricants Paints and Coatings Adhesives Printing Ink Cleaning Chemicals Positive Displacement Flow Meters
  29. 29. Agricultural Dispensing
  30. 30. What’s New?
  31. 31. The new MX Flowmeter series  Pulser range only  Manufactured from solid Billet (St.St and Aluminium)  Increased Temp (150oC)  Pressure Ratings (2000psi)  Anodised Aluminium body  Choice of 9 interchangeable Pulse Output or Display Modules.
  32. 32. M-Lock™ mounting system We have developed a new ¼” turn (Bayonet fitting) mounting system for our Pulse Output and Display modules.
  33. 33. Approved for Hazardous Areas  Intrinsically Safe (Ex ia)  Flameproof (Exd)  Approved ATEX,  Approved IECEx pending *Note: Ex option only available with the Industrial Flowmeter Series
  34. 34. Online Resources Macnaught has developed a comprehensive set of web based resources in order to support customers throughout the entire process of selecting, applying and maintaining the MX Flow meter range. http://www.macnaught.com.au/mx_resources/index.html
  35. 35. Interactive Web Tools  Automated Flowmeter Selection Tool  Specifications Tool  Conversion Tool (coming soon)
  36. 36. Online Information General web based resources Quick Reference Guides General Specifications 3D Drawings Instruction Manuals Service Videos Brochures
  37. 37. Marketing Resources MX Demo Kit We have developed an MX Demonstration Kit to compliment the launch of the MX series. table top exhibitions in-house display staff training direct sales tool.
  38. 38. Overview of the new generation MX Series
  39. 39. Flowmeter Range overview  The range consists of over 1,000 flowmeter models.  Process Connection sizes range from ¼” to 4” (6mm – 100mm)  Flow Rates range from 0.0083 – 1200 l/min  Stainless Steel and Alum.
  40. 40. Range Segmentation Application Based Focused on Ideal applications 1. Fuel and Oil 2. Solvent 3. Industrial All Inclusive PART number 1. Includes Flange Styles 2. Includes displays
  41. 41. MX part numbering convention
  42. 42. MX25F-1SA Breakdown of the part numbering system Part Number
  43. 43. MX25F-1SA Breakdown of the part numbering system MX … Flowmeter Series Part Number
  44. 44. MX25F-1SA Breakdown of the part numbering system MX … Flowmeter Series 25 … Size and Flow Range Part Number
  45. 45. MX25F-1SA F Breakdown of the part numbering system MX … Flowmeter Series 25 … Size and Flow Range F … Industry Type or Family Part Number
  46. 46. MX25F-1SA Breakdown of the part numbering system MX … Flowmeter Series 25 … Size and Flow Range F … Industry Type or Family 1 … Port style (process connection) Part Number
  47. 47. MX25F-1SA Breakdown of the part numbering system MX … Flowmeter Series 25 … Size and Flow Range F … Industry Type or Family 1 … Port style (process connection) S … Rotor Type Part Number
  48. 48. MX25F-1SA Breakdown of the part numbering system MX … Flowmeter Series 25 … Size and Flow Range F … Industry Type or Family 1 … Port style (process connection) S … Rotor Type A … Display or Pulser Output Type Part Number
  49. 49. MX25F-1SA Size and Flow Range Model No. (mm) Size Flow Range MX06 ¼” 0.5 – 100 l/hr MX09 ¼” 15 – 500 l/hr MX12 ½” 2 – 30 l/min MX19 ¾” 3 – 80 l/min MX25 1” 6 – 120 l/min MX40 1 ½” 10 – 250 l/min MX50 2” 15 – 500 l/min MX75 3” 20 – 750 l/min MX100 4” 120 – 1200 l/min
  50. 50. MX25F-1SA Industry Type or Family Fuel and Oil (F) Solvents (S) Industrial (P) • Al meter body • PPS rotors • Viton Seals • • • • • • Al meter body SS rotors Teflon Seals Fuel & Oil Flowmeters SS meter body PPS or SS rotors Teflon Seals
  51. 51. MX25F-1SA Port Style (process connection) 1. 2. 3. 4. 5. BSP (Rp) NPT ANSI 150lb JIS 10K DIN PN16
  52. 52. MX25F-1SA Rotor Type Fuel and Oil series S = PPS Rotors Solvent series S = Models MX06 - MX025 Models MX40 – MX100 Stainless Steel Rotors Aluminium Rotors Industrial series S = PPS V = High Viscosity Stainless Steel Rotors T = High Temp Stainless Steel
  53. 53. MX25F-1SA Display or Pulser Output Modules A B C D E F G H T Standard Pulse Intrinsically Safe (Ex ia) Flameproof (Ex d) PR (12mm LCD) PRA (12mm LCD with outputs) ER (17mm LCD) ERA (17mm LCD with outputs) ERB (17mm LCD Batch controller) High Temp (max 150oC)
  54. 54. Pulser Output and Display Modules
  55. 55. Type A Compact Compact • • • • • Polypropylene Housing IP 67 Pulser Output 1x Reed switch 1x Hall Effect (NPN)
  56. 56. Type B Approved Ex ia Intrinsically Safe • • • • • • • • Stainless Steel Pulser Output NPN Open Collector Approved Ex ia ATEX FM CSA IECEx pending *Note: Ex option only available with the Industrial Flowmeter Series
  57. 57. Type C Approved Exd Flameproof • • • • • • Stainless Steel Pulser Output NPN Open Collector Approved Exd ATEX IECEx pending *Note: Ex option only available with the Industrial Flowmeter Series
  58. 58. Type D PR Digital Display Display • • • • • • • Meter Mount or Wall Mount Polypropylene Housing IP67 7 Digit – 12mm upper 7 Digit – 8mm lower Total Resettable Flow Rate Accumulated Total (non-resettable)
  59. 59. Type E PRA Digital Display Display • • • • • • • Meter Mount or Wall Mount Polypropylene Housing IP67 7 Digit – 12mm upper 7 Digit – 8mm lower Total Resettable Flow Rate Accumulated Total (non-resettable) Outputs • • • 4-20mA (passive) Scaled Pulse Output Hi/Lo Flow Alarm
  60. 60. Type F ER Digital Display Display • • • • • • • Meter Mount or Remote Mount Aluminium housing IP 67 7 Digit – 17mm upper 7 Digit – 8mm lower Total Resettable Flow Rate Accumulated Total (non-resettable)
  61. 61. Type G ERA Digital Display Display • • • • • • • Meter Mount or Remote Mount Aluminium housing IP 67 7 Digit – 17mm upper 7 Digit – 8mm lower Total Resettable Flow Rate Accumulated Total (non-resettable) Output • 4-20mA (passive) • Scaled Pulse
  62. 62. Type H ERB Batch Controller Display • • • • • • • Meter Mount or Remote Mount Aluminium housing IP 67 7 Digit – 17mm upper 7 Digit – 8mm lower Total Resettable Flow Rate Accumulated Total (non-resettable) Output • 4-20mA (passive) • Scaled Pulse
  63. 63. Type T High Temperature Intrinsically Safe • • • • Stainless Steel Pulser Output NPN Open Collector Max temp 150oC
  64. 64. ERS Digital Register Summation / Differential Display • • • • • • • Remote Mount only Aluminium housing IP 67 7 Digit – 17mm upper 7 Digit – 8mm lower 2 Flowmeter inputs Calculates differential Sums Output • Transistor
  65. 65. Accessories Flanged Process Connections • Flanges are now screwed into the Meter body • Available in ANSI, DIN, JIS Wall Mount Adaptors • Aluminium wall mount adaptors available for models MX06-25 Strainers / Air Eliminators • A variety of SS Y-Strainers, and Air Eliminator/Strainer combinations are available. Turck Cables •2mtr cables to suit Ex ia and High Temp Pulser switches