  • 1. MISKI BAYÓVARPROJECT0111TITLE MAYO N° MISKI MAYO KOO20 PAGEBASIC ENGINEERING ET - 3010 - M - 301 1/213010 N°AMEC REV.TECHNICAL SPECIFICATION FOR DESALlNATION PLANT B 2109- ET - 3010 - M - 301 REVISIONTE:TIPODE A - PRELIMINAR C - PARACONOCIMIENTO E - PARACONSTRUCCiÓN G - CONFORMECONSTRUIDOEMISiÓN B - PARAAPROBACiÓN D - PARACOTIZACiÓN F - CONFORMECOMPRADO H - CANCELADORev. TE Descripción Por Ver. Apr. Aut. Fecha A A PARA COORDINACION INTERNA ACP JV FS B B PARA APROBACION ACP JV FS PARA APROBACION DEL CLIENTE Aprobado Aprobado con Comentarios Rechazado y volver a emitir Aprobado sin revisión del Cliente fecha firma ~ 00 IN 1- (Xj{~ 15 NOV2006
  • 2. MISKI BAYÓVAR PROJECT0111TITLE MAYO N° MISKI MAYO KOO20 PAGEBASIC ENGINEERING ET - 3010 - M - 301 2/213010 N°AMEC REV.TECHNICAL SPECIFICATION FOR DESALlNATION PLANT 2109- ET - 3010 - M - 301 B MISKI MAYO PROJECT N° 2109 BAYÓVAR PROJECT BASIC ENGINEERING TECHNICAL SPECIFICATION N° ET-3010-M-301 FOR DESALlNATION PLANT Prepared by: AMEC International (Chile) S.A. Approved by:Lead Discipline (JV)Engineering Manager (PF)Project Manager (FS)Client (TF) ~.OO¡U rf- (X)C{5 15 NOV2006
  • 3. MISKI BAYÓVAR PROJECT MAYO K0020TÍTLE Nº MISKI MAYO PÁGEBASIC ENGINEERING ET - 3010 - M - 301 3/213010 Nº AMEC REV.TECHNICAL SPECIFICATION FOR DESALINATION PLANT 2109- ET - 3010 - M - 301 B CONTENT Page1.0 SCOPE .............................................................................................................................. 42.0 APPLICABLE CODES, STANDARDS AND REFERENCES ........................................... 53.0 GENERAL REQUIREMENTS ........................................................................................... 64.0 TECHNICAL REQUIREMENTS ........................................................................................ 85.0 SEISMIC DESIGN CRITERIA ......................................................................................... 106.0 INSPECTION AND TESTING ......................................................................................... 107.0 DOCUMENTATION REQUIRED WITH THE BID ........................................................... 128.0 SHIPMENT ...................................................................................................................... 129.0 TRAINING OF PERSONNEL .......................................................................................... 1210.0 TECHNICAL PERFORMANCE GUARANTTE REQUIREMENTS ................................. 1311.0 DATA SHEETS ............................................................................................................... 13APPEND 1 WATER CHARACTERISTICS ET-3010-M-301_A TECHNICAL SPECIFICATION FOR DESALINATION PLANT
  • 4. MISKI BAYÓVAR PROJECT MAYO K0020TÍTLE Nº MISKI MAYO PÁGEBASIC ENGINEERING ET - 3010 - M - 301 4/213010 Nº AMEC REV.TECHNICAL SPECIFICATION FOR DESALINATION PLANT 2109- ET - 3010 - M - 301 B1.0 SCOPE1.1 Work Included This Technical Specification covers the general requirements for the design, materials, fabrication, inspection, testing, packaging, personnel training, pre-operational testing and commissioning of a new Desalination Plant for the Bayóvar Project available for sea water treatment, with the capacity and characteristics indicated on the data sheets. Work shall include the design of the complete package according to, but is not limited to, the following items: • Desalination unit. • Pre-treatment system. • Post treatment system. • Main feed tank. • Additives tanks • Required pumps with electric motors • Chemical dosing system • All interconnection piping • Control panels • All instruments and control system for an automatic operation • All safety devices • Spare parts for 2 year operation. The units shall be complete and ready for mounting and operation except for items listed as exclusions in paragraph 1.2 of this specification. The design and function of this equipments, components and accessories are Vendor’s responsibility and design shall be for a minimum of 20 year life. All construction material for this equipments, components and accessories shall be new, of high quality, free of defects and shall be approved as standard for the intended service and operating conditions and meet the requirements of both codes and standard referenced in this specification, under paragraph 2.0. Supplier’s Quality Assurance Program for the construction of the Desalination Plant shall comply as a minimum with the requirements of chapter 6 of this specification (Inspection and Testing). ET-3010-M-301_A TECHNICAL SPECIFICATION FOR DESALINATION PLANT
  • 5. MISKI BAYÓVAR PROJECT MAYO K0020TÍTLE Nº MISKI MAYO PÁGEBASIC ENGINEERING ET - 3010 - M - 301 5/213010 Nº AMEC REV.TECHNICAL SPECIFICATION FOR DESALINATION PLANT 2109- ET - 3010 - M - 301 B1.2 Work Excluded The following items shall be excluded from the supply: • Structural foundation • Electrical wiring and conduit external to the equipment. • Walkways, platforms, stairways, and railings. • External piping.2.0 APPLICABLE CODES, STANDARDS AND REFERENCES Design and construction shall conform to all codes, specification or standards referenced in this document, its attachments, and procurement documents to the extent noted, the Peruvians laws and norms shall be considered.2.1 Requirements of Regulatory Agencies Applicable requirements of OSHA and MSHA shall apply unless otherwise noted. The applicable sections of the latest issues of the following codes and standards form a part of this specification: ABMA - American Bearing Manufacturers Association AGMA - American Gear Manufacturers Association AISC - American Institute of Steel Construction ANSI - American National Standards Institute ASME - American Society of Mechanical Engineers ASTM - American Society for Testing and Materials AWS - American Welding Society IEC - International Electrotechnical Commission IEEE - Institute of Electrical and Electronic Engineers NEC - National Electric Code NEMA - National Electrical Manufacturers Association SAE - Society of Automotive Engineers ET-3010-M-301_A TECHNICAL SPECIFICATION FOR DESALINATION PLANT
  • 6. MISKI BAYÓVAR PROJECT MAYO K0020TÍTLE Nº MISKI MAYO PÁGEBASIC ENGINEERING ET - 3010 - M - 301 6/213010 Nº AMEC REV.TECHNICAL SPECIFICATION FOR DESALINATION PLANT 2109- ET - 3010 - M - 301 B JIC - Joint Industry Conference NFPA - National Fire Protection Association ISO - International Organization for Standardization UL - Underwriters Laboratories Inc. ISA - Instrument Society of America UBC - Uniform Building Code In the event of differences between codes and/or standard, the most stringent code or standard shall apply. Standards from other countries may be accepted subjected to Purchaser approval. Vendor shall state this situation, together with his exception lists. Any conflict between the documents and the Purchase Order document shall be referred to the Purchaser for clarification before proceeding with the manufacturing of the affected parts. Nevertheless, Vendor shall remain responsible for the supply and correct operation of the Desalination Plant, under conditions stated herein.3.0 GENERAL REQUIREMENTS The desalination plants will include all devices required to produce desalinated water, including a chlorinating system for to produce drinkable water of a portion of desalinated water. Equipment capacity and operating data are indicated on the attached Data Sheets. Vendor shall assume full coordination responsibility for the entire Desalination Plant with your sub-suppliers. The drinkable water quality shall be complying with “Ley General de Aguas del Peru DL 17752” for quality water for human consumption. The equipment, frame, motor and anchors shall withstand seismic conditions specified in Data Sheets of this technical specification. Vibration level of the equipment shall be the minimum as possible. Vendor shall inform about normal and critical vibration levels and supply drawings of suggested foundation or slab. Shock absorbers to reduce vibration transmission will not be accepted. ET-3010-M-301_A TECHNICAL SPECIFICATION FOR DESALINATION PLANT
  • 7. MISKI BAYÓVAR PROJECT MAYO K0020TÍTLE Nº MISKI MAYO PÁGEBASIC ENGINEERING ET - 3010 - M - 301 7/213010 Nº AMEC REV.TECHNICAL SPECIFICATION FOR DESALINATION PLANT 2109- ET - 3010 - M - 301 B Vendor shall deliver sufficient information for the design and calculations of the foundations such as gravity centre position, static and dynamic vertical and horizontal forces and moment etc. 3 Drinkable Seawater 1 DESALINATION Water PRE TREATMENT DRINKABLE PLANT TRAIN(S) WATER UNIT DS-3010-01 ST-3070-01 4 2 Battery Limits 5 TANK Seal Water 3 2.100 m TQ-3010-01 Desalinated water Desalinated water Rejection Process Water Design Flow Pressure Flow No. m3/d kPag 1 Vendor Vendor 2 3532 Vendor 3 36 Vendor 4 36 Vendor 5 Vendor VendorET-3010-M-301_A TECHNICAL SPECIFICATION FOR DESALINATION PLANT
  • 8. MISKI BAYÓVAR PROJECT MAYO K0020TÍTLE Nº MISKI MAYO PÁGEBASIC ENGINEERING ET - 3010 - M - 301 8/213010 Nº AMEC REV.TECHNICAL SPECIFICATION FOR DESALINATION PLANT 2109- ET - 3010 - M - 301 B4.0 TECHNICAL REQUIREMENTS4.1 Desalination Plant and Related Components The sea water characteristics and product water are showed in Append 1 The plant will be installed outdoor at 35 km to the sea coast. The sea water supply to the plant will be from the reservoir tank PD-3000-01 and will be pumped to the tank inlet plant. If same components of plant must be indoor, these components shall be located in adapted container (by vendor). The plant will included the needed related component such as pre treatment system, chlorination and salinization system and any another components required for a properly operation. Storage of potable water will be in tanks, supplied by others.4.2 Mechanical The desalination plant will be pre-assembled, skid mounted and on site will be mounted on simple concrete foundations (by others) and served by common systems for seawater feed, pretreatment system, electric power supply, product removal and brine disposal by piping back to the dispose point. The main vessels shall made of mild steel properly stiffened to withstand vacuum conditions and painted with epoxy resin paint on both sides to ensure effective corrosion resistance. Pipes will be of material immune to corrosion, including seawater feed and brine. Pump materials and characteristics are so selected as to ensure steady trouble free operation and high efficiency performance.4.3 Special Tools All special tools required for assembly and disassembly of the plant shall be included in the scope of supply.4.4 Noise Level Noise level will not exceed 85 dB(A) at 1 m, from each item.4.5 Electrical Electrical System shall be in accordance with Vendor’s Standard Electrical Specification ET-3010-M-301_A TECHNICAL SPECIFICATION FOR DESALINATION PLANT
  • 9. MISKI BAYÓVAR PROJECT MAYO K0020TÍTLE Nº MISKI MAYO PÁGEBASIC ENGINEERING ET - 3010 - M - 301 9/213010 Nº AMEC REV.TECHNICAL SPECIFICATION FOR DESALINATION PLANT 2109- ET - 3010 - M - 301 B and Standard requirements for electrical components supplied w/ Mechanical Equipment Nº 2109-ET- 0000-E-306. Desalination Plant Vendor shall, whenever possible, standardize required electrical components such as motors and controls, for maintenance and consideration of spare parts. Purchaser shall supply all distribution, motor starters, and power and control cables. The Manufacturer shall indicate all requirements of control elements, interlocking, and others. All electrical components shall be wired up to terminal strips located in junction boxes with NEMA 4X type enclosure.4.6 Electric Motors Electric motors shall be manufactured in accordance with NEMA standards or its equivalent IEC standards. Motors shall be TEFC enclosure, NEMA B design and insulation class F, with temperature rise B. Minimum power factor shall be 0.86. Service factor at site conditions shall be 1.0. Refer to Low Tension Electric Motor Technical Specification Nº 2109-ET-0000-E-308. Power feed shall be as follows: • Less than 0,37 kW : 220 V, single-phase, 60 Hz. • From 0,37 kW up to 150 kW : 440 V, three-phase, 60 Hz. • Larger than 150 kW : 4000 V, three-phase, 60 Hz.4.7 Controls and Instrumentation Vendor shall apply Instruments Requirements for Mechanical Equipment according with Technical Specification Nº 2109-ET-0000-J-302. Systems requiring protection shall be provided with suitable sensing devices to initiate alarm and, when necessary, to provide automatic shut down to protect the equipment. Controls furnished shall operate smoothly in both loaded and unloaded condition. Instrument shall be designed for heavy duty operation. Vendor shall supply a local control panel with all status, alarms and all indication that allow the operator and maintenance personnel to operate the plant. The Desalination Plant must have the capacities of being operated and supervised remotely from a centralized control room. ET-3010-M-301_A TECHNICAL SPECIFICATION FOR DESALINATION PLANT
  • 10. MISKI BAYÓVAR PROJECT MAYO K0020TÍTLE Nº MISKI MAYO PÁGEBASIC ENGINEERING ET - 3010 - M - 301 10/213010 Nº AMEC REV.TECHNICAL SPECIFICATION FOR DESALINATION PLANT 2109- ET - 3010 - M - 301 B5.0 SEISMIC DESIGN CRITERIA Seismic design criteria shall be Zone 4 UBC 1997 Code. The supplier shall perform a seismic analysis of the Desalination Plant components. The results of the calculations, including loads on the foundations, shall be submitted to the Purchaser for information.6.0 INSPECTION AND TESTING6.1 General Quality inspection procedures shall be according to Vendor’s standards. Vendor shall include in his bid a detailed fabrication inspection program. Equipment shall be completely shop assembled, tested and operated under no load conditions at rated speed to ensure proper alignment and adequacy of all functional parts. All components shall be properly match marked. Items requiring precision alignment and location shall be provided with a minimum of two (2) dowel pins or fitted bolts to ensure proper alignment in the field. The Purchaser or designated inspector reserves the right to witness all testing procedures in the Vendor’s shop. Vendor shall ensure that the required properties of the materials utilized in fabrication of the plant are obtained. Vendor’s purchase orders for materials shall include the requirements for certification of all chemical and mechanical properties including through thickness tensile test results for special steels, as specified. Purchaser shall have the right to review test reports. Coupons of appropriate size of all castings, plates, etc., shall be kept for inspection by the Purchaser or its representative.6.2 Non-Destructive Examination The non-destructive examination requirements specified herein are Purchaser’s minimum requirements. In the Requisition are including specified Inspection and Quality Plan. ET-3010-M-301_A TECHNICAL SPECIFICATION FOR DESALINATION PLANT
  • 11. MISKI BAYÓVAR PROJECT MAYO K0020TÍTLE Nº MISKI MAYO PÁGEBASIC ENGINEERING ET - 3010 - M - 301 11/213010 Nº AMEC REV.TECHNICAL SPECIFICATION FOR DESALINATION PLANT 2109- ET - 3010 - M - 301 B6.3 Inspection Reports Before delivery, the following inspection reports shall be indexed, bound and made available for Purchaser’s. • Materials certificates, including chemical composition and mechanical properties. • Ultrasonic examinations records of forged and cast steel pieces. • Penetrating liquid examination records of forged and cast steel pieces. • Radiographic examination records for casting, welding and forgings. • Dimensional examinations records. • Cast test coupons shall be attached to the castings and undergo the same heat treatment as the castings. In addition, it is expected that the Vendor will follow all other procedures, examinations and tests that are normally carried out according to sound manufacturing and industry practice. All rotating elements and ancillary equipments shall be dimensionally checked upon completion. All critical dimensions shall be checked including, as a minimum, overall length, outside diameter, concentricity and squaring of all rotating elements. Purchaser shall be notified of all dimensional differences from Vendor’s drawing that could affect Buyer’s foundation or external connection designs. Any major repairs performed after final thermal stress relief shall require thermal stress relief at Vendor’s cost. Depths of repair exceeding 10 percent of section thickness or 10 mm shall be considered major repairs. Test and quality controls mentioned above shall conform to a strict Quality Assurance Program. Elaboration of this program is Vendor responsibility and shall be included in the bid for Purchaser’s evaluation.6.4 Specifications and Data Requirements The following specifications and data shall be reviewed and approved by the Purchaser prior to fabrication: • Fabrication, inspection and quality control procedures and Quality Assurance Program. • Welding procedures including welding procedure qualification test records and procedures for control of low hydrogen filler materials. • Non destructive examination procedures. • Weld repair procedures. ET-3010-M-301_A TECHNICAL SPECIFICATION FOR DESALINATION PLANT
  • 12. MISKI BAYÓVAR PROJECT MAYO K0020TÍTLE Nº MISKI MAYO PÁGEBASIC ENGINEERING ET - 3010 - M - 301 12/213010 Nº AMEC REV.TECHNICAL SPECIFICATION FOR DESALINATION PLANT 2109- ET - 3010 - M - 301 B • Surface preparation and painting procedures.7.0 DOCUMENTATION REQUIRED WITH THE BID Bidder shall supply all drawings and data listed in Bidders Drawing & Data Commitments including P&ID’s, basic arrangement, loads on foundations, electrical and hydraulic diagrams, operation and maintenance Manual in Spanish.8.0 SHIPMENT8.1 Each item shall be identified with a securely attached non-corrosive metal tag impression stamped with the equipment No. and description with purchase order number.8.2 All components that must be disassembled for shipment shall be properly matched marked. Items requiring precision alignment and location shall be provided with a min. of 2 dowel pins of fitted bolts to assure proper alignment in the field.8.3 Bidder shall adequately prepare all components for export shipment, recognizing the requirements for inland transport, stevedore handling, and marine transport (if required). Subassemblies shall be as large as transportation facilities will permit.8.4 The shipment of loose, individual components shall be avoided.9.0 TRAINING OF PERSONNEL Vendor will train the technicians and mechanics designated by the Client in proper operating and maintenance procedures, during the erection and commissioning period. In addition to training derived through direct participation in the erection, commissioning and initial operation of the plant it is suggested that the Client send his personnel to assembly shop to participate in the assembly of the unit and factory pre-shipment tests. This program will enable them to become thoroughly familiar with the plants inner works, the function and design of each individual subsystem and with proven trouble-shooting procedures. A Preliminary training schedule shall be attached to the technical offer. ET-3010-M-301_A TECHNICAL SPECIFICATION FOR DESALINATION PLANT
  • 13. MISKI BAYÓVAR PROJECT MAYO K0020TÍTLE Nº MISKI MAYO PÁGEBASIC ENGINEERING ET - 3010 - M - 301 13/213010 Nº AMEC REV.TECHNICAL SPECIFICATION FOR DESALINATION PLANT 2109- ET - 3010 - M - 301 B10.0 TECHNICAL PERFORMANCE GUARANTTE REQUIREMENTS Supplier shall guarantee that the equipments will operate in accordance with requirements stated in this specification. Defective work caused by improper shipping, improper protective measures, poor workmanship, defective or incorrect materials, incorrect shop fabrication procedures, or any other reason within the area of responsibility of the Supplier, shall be corrected by Supplier at his own expense, to the satisfaction of Buyer. Following issuance of the certificate of Field Assembly Inspection, and at a time agreeable at both Buyer and Supplier, a one week trial run shall be performed for the equipment, under the supervision of Supplier’s representative. Prior to the trial run, the Supplier’s representative shall train the operating personnel. When the plant is operating at design conditions, and at a time agreeable to both Supplier and Buyer, the Performance Guarantee test run shall be carried out for the equipment. Duration of the test run for performance guarantee shall be a 48 hours operation. The test shall be performed by qualified personnel. Operating personnel and supporting materials, utilities, etc to assist in the performance of the test work will be provided by buyer. All other costs for the test work, such as contract cost of an approved testing laboratory, shall not be included in the Supplier’s scope of supply. Conditions applicable to Performance Guarantee Test Run shall be as indicated in data sheet A. In the event that the guaranteed figures are not met due to failure of the equipment, Supplier shall be responsible for any corrective action necessary to bring the equipment into compliance, and will be responsible for all Supplier’s costs for correction and all vendor cost for correction and subsequent performance guarantee test runs until compliance is achieved.11.0 DATA SHEETS The following data sheets form part of this equipment specification and shall be considered and/or filled out and returned with Vendor’s bid: ET-3010-M-301_A TECHNICAL SPECIFICATION FOR DESALINATION PLANT
  • 14. MISKI BAYÓVAR PROJECT MAYO K0020 TÍTLE Nº MISKI MAYO PÁGE BASIC ENGINEERING ET - 3010 - M - 301 14/21 3010 Nº AMEC REV. TECHNICAL SPECIFICATION FOR DESALINATION PLANT 2109- ET - 3010 - M - 301 B DATA SHEET A DUTY AND SERVICE REQUIREMENTDESALINATION PLANT REQUISICIÓN Nº: TAG Nº: DS-3010-01/ST-3070-01 DESCRIPTION DATA1.0 NUMBER AND SIZE OF UNITS One (1)2.0 EQUIPMENT NUMBER DS-3010-01 Desalination Plant ST-3070-01 Drinkable water system3.0 DUTY CYCLE Hours per day 20 Days per week 7 Days per year 3654.0 AMBIENT CONDITIONS Plant Location Sechura, Piura, Perú Indoors or Outdoors Outdoors Environment, Clean or Dusty Very Dusty Environment humidity 70 – 85 % Elevation 32 m. a. s. l Maximum Temperature @ unit 33,4 °C Ambient Minimum Temperature @ unit 14,6 °C Ambient5.0 DESCRIPTION OF OPERATION The plant is required for obtain desalinated and drinkable Description water from sea water. Equipment availability 95%6.0 CAPACITY Desalination Plant offered Nominal capacity m3/day 3532 for 20 operation hours per day (product) 3 Design Capacity m /day (max.& min) 3800 ET-3010-M-301_A TECHNICAL SPECIFICATION FOR DESALINATION PLANT
  • 15. MISKI BAYÓVAR PROJECT MAYO K0020 TÍTLE Nº MISKI MAYO PÁGE BASIC ENGINEERING ET - 3010 - M - 301 15/21 3010 Nº AMEC REV. TECHNICAL SPECIFICATION FOR DESALINATION PLANT 2109- ET - 3010 - M - 301 B DATA SHEET A DUTY AND SERVICE REQUIREMENTDESALINATION PLANT REQUISICIÓN Nº: TAG Nº: DS-3010-01/ST-3070-01 DESCRIPTION DATA Reject at maximum capacity, % *7.0 POTABLE WATER Nominal Capacity m3/day 36 Water Characteristics Quality Characteristics shall comply with “Ley general de aguas de Peru DL 17752”8.0 UTILITIES Indicate additives and flows Steam (if required) Flow Kg/h Pressure kPag Air Type and Pressure Electrical Services 4,16 KV AC, 3 ph, 60 Hz, High resistance grounded for supply of 4.0 kV motor and other loads (> 150 kW) . 460 V AC, 3 ph, 60 Hz, High resistance grounded for supply of 0,37 kW motor and others loads(P≤150 kW) ET-3010-M-301_A TECHNICAL SPECIFICATION FOR DESALINATION PLANT
  • 16. MISKI BAYÓVAR PROJECT MAYO K0020 TÍTLE Nº MISKI MAYO PÁGE BASIC ENGINEERING ET - 3010 - M - 301 16/21 3010 Nº AMEC REV. TECHNICAL SPECIFICATION FOR DESALINATION PLANT 2109- ET - 3010 - M - 301 B DATA SHEET B EQUIPMENT VENDOR DATA REQUISICIÓN Nº:DESALINATION PLANT TAG Nº: DS-3010-01/ ST-3070-01 DESCRIPTION REQUESTED OFFERED PURCHASED1.0 SUMMARY Supplier Address Phone/Fax Manufacturer Nominal Unit Size Outline Dimensions (m) Total Weight (kg)2.0 DUTY CYCLE Hours per day 24 Days per week 7 Days per year 3653.0 OPERATING DATA Processed material Sea water 3 Design Rate , m /day * Solid content See append 1 Process Type Reverse osmosis or Evaporation4.0 MATERIALS Filters sand tank Filters activated carbon tank Additives tank Media filter Pumps Piping5.0 SAND FILTER Standard design tank Work pressure Design pressure ET-3010-M-301_A TECHNICAL SPECIFICATION FOR DESALINATION PLANT
  • 17. MISKI BAYÓVAR PROJECT MAYO K0020 TÍTLE Nº MISKI MAYO PÁGE BASIC ENGINEERING ET - 3010 - M - 301 17/21 3010 Nº AMEC REV. TECHNICAL SPECIFICATION FOR DESALINATION PLANT 2109- ET - 3010 - M - 301 B DATA SHEET B EQUIPMENT VENDOR DATA REQUISICIÓN Nº:DESALINATION PLANT TAG Nº: DS-3010-01/ ST-3070-01 DESCRIPTION REQUESTED OFFERED PURCHASED Inlet connection diameter Outlet connection diameter Flanges type Dimension (diam. x height) m Weight empty tank (kg) Weight charged tank (kg) Weight in operation tank (kg) Quantity6.0 ACTIVATED CARBON FILTER Standard design tank Work pressure Design pressure Inlet connection diameter Outlet connection diameter Flanges type Dimension (diam. x height) m Weight empty tank (kg) Weight charged tank (kg) Weight in operation tank (kg) Quantity7.0 Osmotic membrane (if required) Material and supplier Feed Pressure, kPa Reject Pressure, kPa Filtration rate, % Useful life, Operation hour Warranty life, operation hours7.1 Pipe carries Material / Sch Length ET-3010-M-301_A TECHNICAL SPECIFICATION FOR DESALINATION PLANT
  • 18. MISKI BAYÓVAR PROJECT MAYO K0020 TÍTLE Nº MISKI MAYO PÁGE BASIC ENGINEERING ET - 3010 - M - 301 18/21 3010 Nº AMEC REV. TECHNICAL SPECIFICATION FOR DESALINATION PLANT 2109- ET - 3010 - M - 301 B DATA SHEET B EQUIPMENT VENDOR DATA REQUISICIÓN Nº:DESALINATION PLANT TAG Nº: DS-3010-01/ ST-3070-01 DESCRIPTION REQUESTED OFFERED PURCHASED Operation pressure8.0 Evaporators Tubes and End Plates (If required) Tubes End plates9.0 Carryover Separator (If required) Type Material10.0 Steam Compressor (If required) Manufacturer Type Materials of construction Design11.0 Heat Exchanger (If required) Type Material12.0 Instruments Flowmeters Conductivity meter pH meter Flow controller Alarms CIP system PLC13.0 Drinkable Water System Manufacturer Type Maximum capacity, m3/h ET-3010-M-301_A TECHNICAL SPECIFICATION FOR DESALINATION PLANT
  • 19. MISKI BAYÓVAR PROJECT MAYO K0020 TÍTLE Nº MISKI MAYO PÁGE BASIC ENGINEERING ET - 3010 - M - 301 19/21 3010 Nº AMEC REV. TECHNICAL SPECIFICATION FOR DESALINATION PLANT 2109- ET - 3010 - M - 301 B DATA SHEET B EQUIPMENT VENDOR DATA REQUISICIÓN Nº:DESALINATION PLANT TAG Nº: DS-3010-01/ ST-3070-01 DESCRIPTION REQUESTED OFFERED PURCHASED13.1 Dosage system (if required) Additive Pump type Additive flow Dosage type (in line / tank /other)14.0 WEIGHTS AND SIZES Total Weight (kg) Total Shipment Volume (m3) Largest Piece for Erection (Identify) Largest Piece for Erection (mm) Heaviest Piece (Identify) Heaviest Piece During Erection (kg) Heaviest Piece During Maintenance (Identify) Heaviest Piece During Maintenance (kg)15.0 UTILITIES REQUIRED FOR OPERATION OF THE PLANT Instrument or Plant Air, Quantity/Pressure Fresh Water, Quantity/Pressure Electrical Requirements 4,16 KV AC, 3ph, 60hz. 0,46 KV AC, 3ph, 60hzNOTES: ET-3010-M-301_A TECHNICAL SPECIFICATION FOR DESALINATION PLANT
  • 20. MISKI BAYÓVAR PROJECT MAYO K0020TÍTLE Nº MISKI MAYO PÁGEBASIC ENGINEERING ET - 3010 - M - 301 20/213010 Nº AMEC REV.TECHNICAL SPECIFICATION FOR DESALINATION PLANT 2109- ET - 3010 - M - 301 B APPEND 1 WATER CHARACTERISTICSET-3010-M-301_A TECHNICAL SPECIFICATION FOR DESALINATION PLANT
  • 21. MISKI BAYÓVAR PROJECT MAYO K0020TÍTLE Nº MISKI MAYO PÁGEBASIC ENGINEERING ET - 3010 - M - 301 21/213010 Nº AMEC REV.TECHNICAL SPECIFICATION FOR DESALINATION PLANT 2109- ET - 3010 - M - 301 B CHEMICAL CHARACTERISTICS OF THE SEA WATER SEA WATERTemperature 17 – 28° CSpecific gravity 1,025Transparency 2,8 mOxygen 5,0 – 6,2 mg/lTotal Phosphate 0,032 – 0,063 mg/lLead < 0,050 mg/lCadmium < 0,020 mg/lDissolved Silica 1,0 – 2,1 mg/lNitrates 0,18 – 0,27 mg/lMercury < 0,001 mg/lCooper < 0,012 mg/lSalinity 34,6 – 34,7 ‰Biochemical oxygen demand BOD < 2,0 mg/lSuspended solids 10,0 – 18,8 mg/l ET-3010-M-301_A TECHNICAL SPECIFICATION FOR DESALINATION PLANT

×