DIT Arch Tech Thesis 2010

813
views

Published on

DIT Arch Tech Bsc (Hons) Presentation

DIT Arch Tech Bsc (Hons) Presentation


0 Comments
0 Likes
Statistics
Notes
  • Be the first to comment

  • Be the first to like this

No Downloads
Views
Total Views
813
On Slideshare
0
From Embeds
0
Number of Embeds
1
Actions
Shares
0
Downloads
32
Comments
0
Likes
0
Embeds 0
No embeds

Report content
Flagged as inappropriate Flag as inappropriate
Flag as inappropriate

Select your reason for flagging this presentation as inappropriate.

Cancel
No notes for slide

Transcript

  • 1. Lake Kee Bsc (Hons) Arch Tech My thesis explored the daylight design and daylight strategies of aproposed community building in Clongriffin, Dublin. Two methods were used toperform the daylight analysis on the building. They were the Daylight FactorCalculation using the Ecotect software and the analysis of the illuminance level inthe building using images generated by the RADIANCE software. The results of bothmethods were then compared. The best daylight design strategy was applied usingthe results.
  • 2. Daylight Analysis of Design Propositions for The Clongriffin Community Centre
  • 3. The Analysis of angle of midday sun for Winter Solstice, Spring Equinox and Summer Solstice
  • 4. Sunpath diagram using Ecotect
  • 5. Light Box Experiment using three different types of roof apertures under a clear skycondition , at 12pm on the 21st of March 2010. The purpose is to study the impact ofdirect sunlight penetration into a room.
  • 6. Options of vertical windows for the Clongriffin Community Centre. Images generated by Revit ArchitectureOption 1 - South East perspective view Option 2 - South East perspective view
  • 7. Daylight Factor Calculation using Ecotect Software withthree options of vertical windows to examine the percentage of daylight penetration
  • 8. Using Radiance generated images to analyse the daylight uniformity and illuminance level of the Clongriffin Community Centre12pm - 21st of March
  • 9. Using Radiance generated images to analyse the daylight uniformity and illuminance level of the Clongriffin Community Centre12pm - 21st of June
  • 10. The construction sequence using Sketchup program
  • 11. The development of the triangular roof light detail
  • 12. The development of the eaves and window detail