Hc data shts 11 17-10

591 views
461 views

Published on

0 Comments
1 Like
Statistics
Notes
  • Be the first to comment

No Downloads
Views
Total views
591
On SlideShare
0
From Embeds
0
Number of Embeds
6
Actions
Shares
0
Downloads
9
Comments
0
Likes
1
Embeds 0
No embeds

No notes for slide

Hc data shts 11 17-10

  1. 1. HC LR-01 RESIDENTIAL CUT-AWAY WALL SECTIONTradical® Hemcrete® Wall System:Internal Wood Frame with Lime Render Exterior Vapor Permeable Paint (2 Coats) Vapor Permeable Magnesium Board Tape and Mud at Magnesium Board Joint Magnesium Board Fastener 2X4 Wood Stud, 16-24” O.C. Tradical® Hemcrete® (variable thickness to suit required thermal performance) 5/8” Baumit FL68 Lime Render Base Coat 1/8” Pre-colored Baumit SEP02 Lime Render Top Coat Flashing Metal Stop Bead at Bottom Edge of Lime Render Brick Veneer at Exposed Foundation Insulative R-Value* 35.5 Efficiency of Construction (# of Trades) 2 Approximate Wall Thickness 13” Embodied Carbon Dioxide Output -4.1 in kilograms per square foot Recyclable or Biodegradable Content 95% Approximate Cost Per Square Foot $29Details are indicative only and need to be made project specific. The above figures reflect the performance of mid-wallWhile reasonable care has been taken to ensure that the information conditions only and do not take into account floor, roof, corner,included in this drawing was accurate at the time of issue, American opening or mechanical conditions.Lime Technology reserves the right to change specifications at anytime. Final detailing remains the responsibility of the designer due to *R-value not adjusted for thermal mass.site and client specific requirements. website: http://www.americanlimetec.com LAST REVISED 2010-11-16 email: info@americanlimetec.com COPYRIGHT 2010 AMERICAN LIME TECHNOLOGY. telephone: 773.286.0566
  2. 2. HC LR-02 RESIDENTIAL CUT-AWAY WALL SECTIONTradical® Hemcrete® Wall System:Central Wood Frame with Lime Render Exterior Vapor Permeable Paint (2 Coats) 1/8” Baumit RK38 or KG30 Interior Lime Plaster Top Coat 3/8” Baumit RK38 Interior Lime Plaster Base Coat 2X4 Wood Stud, 16-24” O.C. Tradical® Hemcrete® (variable thickness to suit required thermal performance) 5/8” Baumit FL68 Lime Render Base Coat 1/8” Pre-colored Baumit SEP02 Lime Render Top Coat Flashing Stop Bead at Bottom Edge of Lime Render Brick Veneer at Exposed Foundation Insulative R-Value* 35.5 Efficiency of Construction (# of Trades) 2 Approximate Wall Thickness 13” Embodied Carbon Dioxide Output -4.1 in kilograms per square foot Recyclable or Biodegradable Content 98% Approximate Cost Per Square Foot $29Details are indicative only and need to be made project specific. The above figures reflect the performance of mid-wallWhile reasonable care has been taken to ensure that the information conditions only and do not take into account floor, roof, corner,included in this drawing was accurate at the time of issue, American opening or mechanical conditions.Lime Technology reserves the right to change specifications at anytime. Final detailing remains the responsibility of the designer due to *R-value not adjusted for thermal mass.site and client specific requirements. website: http://www.americanlimetec.com LAST REVISED 2010-11-16 email: info@americanlimetec.com COPYRIGHT 2010 AMERICAN LIME TECHNOLOGY. telephone: 773.286.0566
  3. 3. HC BV-01 RESIDENTIAL CUT-AWAY WALL SECTIONTradical® Hemcrete® Wall System:Internal Wood Frame with Brick Veneer Exterior Vapor Permeable Paint (2 Coats) Vapor Permeable Magnesium Board Tape and Mud at Magnesium Board Joint Magnesium Board Fastener 2X4 Wood Stud, 16-24” O.C. Tradical® Hemcrete® (variable thickness to suit required thermal performance) 2x2 Wood Furring, 16-24” O.C. Brick Tie Furring Stop Air Cavity (ventilated and drained) Brick Veneer Mortar Net at Base of Air Cavity Brick Cavity Vent Flashing Insulative R-Value* 29.9 Efficiency of Construction (# of Trades) 2 Approximate Wall Thickness 18” Embodied Carbon Dioxide Output -2.1 in kilograms per square foot Recyclable or Biodegradable Content 96% Approximate Cost Per Square Foot $35Details are indicative only and need to be made project specific. The above figures reflect the performance of mid-wallWhile reasonable care has been taken to ensure that the information conditions only and do not take into account floor, roof, corner,included in this drawing was accurate at the time of issue, American opening or mechanical conditions.Lime Technology reserves the right to change specifications at anytime. Final detailing remains the responsibility of the designer due to *R-value not adjusted for thermal mass.site and client specific requirements. website: http://www.americanlimetec.com LAST REVISED 2010-11-16 email: info@americanlimetec.com COPYRIGHT 2010 AMERICAN LIME TECHNOLOGY. telephone: 773.286.0566
  4. 4. HC FC-01 RESIDENTIAL CUT-AWAY WALL SECTIONTradical® Hemcrete® Wall System:Internal Wood Frame with Fiber Cement Siding Exterior Vapor Permeable Paint (2 Coats) Vapor Permeable Magnesium Board Tape and Mud at Magnesium Board Joint Magnesium Board Fastener 2X4 Wood Stud, 16-24” O.C. Tradical® Hemcrete® (variable thickness to suit required thermal performance) 2x2 Wood Furring, 16-24” O.C. 1x2 Vertical Wood Furring, 16-24” O.C. Air Cavity (ventilated and drained) Furring Stop Fiber Cement Siding Insect Mesh at Base of Air Cavity Brick Veneer at Exposed Foundation Wall Flashing Insulative R-Value* 29.9 Efficiency of Construction (# of Trades) 2 Approximate Wall Thickness 14” Embodied Carbon Dioxide Output -3 in kilograms per square foot Recyclable or Biodegradable Content 95% Approximate Cost Per Square Foot $29Details are indicative only and need to be made project specific. The above figures reflect the performance of mid-wallWhile reasonable care has been taken to ensure that the information conditions only and do not take into account floor, roof, corner,included in this drawing was accurate at the time of issue, American opening or mechanical conditions.Lime Technology reserves the right to change specifications at anytime. Final detailing remains the responsibility of the designer due to *R-value not adjusted for thermal mass.site and client specific requirements. website: http://www.americanlimetec.com LAST REVISED 2010-11-16 email: info@americanlimetec.com COPYRIGHT 2010 AMERICAN LIME TECHNOLOGY. telephone: 773.286.0566

×