Your SlideShare is downloading. ×
02 nsr-10 centro de convenciones
Upcoming SlideShare
Loading in...5
×

Thanks for flagging this SlideShare!

Oops! An error has occurred.

×

Saving this for later?

Get the SlideShare app to save on your phone or tablet. Read anywhere, anytime - even offline.

Text the download link to your phone

Standard text messaging rates apply

02 nsr-10 centro de convenciones

266
views

Published on


0 Comments
0 Likes
Statistics
Notes
  • Be the first to comment

  • Be the first to like this

No Downloads
Views
Total Views
266
On Slideshare
0
From Embeds
0
Number of Embeds
0
Actions
Shares
0
Downloads
1
Comments
0
Likes
0
Embeds 0
No embeds

Report content
Flagged as inappropriate Flag as inappropriate
Flag as inappropriate

Select your reason for flagging this presentation as inappropriate.

Cancel
No notes for slide

Transcript

  • 1. CENTRO DE CONVENCIONES ABURRA SUR CAMARA DE COMERCIO - ITAGÜIUPEGUI BUENDIA ARQUITECTOS Carrera 43A# 15 sur 15 - Oficina 404 (Edificio Xerox)Telefax: 317 1797 – e-mail: upeguiarquitectos@gmail.com – Medellín - Colombia
  • 2. SALIDA 1 PUNTO FIJO DE EMERGENCIA RAMPA PEATONAL PEND. 8% LOBBYPLANTA PISO 1 SALIDA 2 UPEGUI BUENDIA ARQUITECTOS Carrera 43A# 15 sur 15 - Oficina 404 (Edificio Xerox) Telefax: 317 1797 – e-mail: upeguiarquitectos@gmail.com – Medellín - Colombia
  • 3. SALIDA 1 PUNTO FIJO DE EMERGENCIAPLANTA PISO 2 SALIDA 2 UPEGUI BUENDIA ARQUITECTOS Carrera 43A# 15 sur 15 - Oficina 404 (Edificio Xerox) Telefax: 317 1797 – e-mail: upeguiarquitectos@gmail.com – Medellín - Colombia
  • 4. SALIDA 1 PUNTO FIJO DE EMERGENCIA ACCESO A LA SALIDA AUDITORIO PRINCIPAL ACCESO A LA SALIDAPLANTA PISO 3 SALIDA 2 UPEGUI BUENDIA ARQUITECTOS Carrera 43A# 15 sur 15 - Oficina 404 (Edificio Xerox) Telefax: 317 1797 – e-mail: upeguiarquitectos@gmail.com – Medellín - Colombia
  • 5. SALIDA 1 PUNTO FIJO DE EMERGENCIA RECORRIDO MAX. 60m (75m CON ROCIADORES) AUDITORIO PRINCIPALPLANTA PISO 3 SALIDA 2 UPEGUI BUENDIA ARQUITECTOS Carrera 43A# 15 sur 15 - Oficina 404 (Edificio Xerox) Telefax: 317 1797 – e-mail: upeguiarquitectos@gmail.com – Medellín - Colombia
  • 6. SALIDA 2 SALIDA 1 PUNTO FIJO DE EMERGENCIA AUDITORIO PRINCIPAL LOBBYSECCIÓN LONGITUDINAL UPEGUI BUENDIA ARQUITECTOS Carrera 43A# 15 sur 15 - Oficina 404 (Edificio Xerox) Telefax: 317 1797 – e-mail: upeguiarquitectos@gmail.com – Medellín - Colombia
  • 7. SALIDA 1 PUNTO FIJO DE EMERGENCIA HACIA VÍA PUBLICA SALIDA 2 HACIA LOBBY LOBBY ACCESO PEATONAL RAMPA PEND. 8%UPEGUI BUENDIA ARQUITECTOS Carrera 43A# 15 sur 15 - Oficina 404 (Edificio Xerox)Telefax: 317 1797 – e-mail: upeguiarquitectos@gmail.com – Medellín - Colombia
  • 8. CALCULO CAPACIDAD DE CARGA CENTRO DE CONVENCIONES ABURRA SUR1. DETERMINAR GRUPO DE OCUPACIÓN SEGÚN TABLA. EN ESTE CASO CORRESPONDE A GRUPO “L: LUGARES DE REUNION” SUBGRUPO L-2 SALON DE CONVENCIONES. SEGÚN TABLA K.3.3-1 NSR-10.2. CALCULAR LA CARGA DE OCUPACIÓN (K) K= ÁREA DEL ESPACIO O PISO ÍNDICE DE OCUPACIÓN3. DETERMINAR FACTOR DE CARGA DE OCUPACIÓN SEGÚN TABLA. EL SALÓN ABURRA SUR ES UN ESPACIO PARA EVENTOS MULTIPLES, SE CLASIFICA COMO USO CONCENTRADO (SIN ASIENTOS) CON UNA ÁREA NETA EN m2 POR OCUPANTE DE 0,5.4. APLICACIÓN DE LA ECUACIÓN. K= 373,23m2 0,5 = 746,465. CALCULO DE NUMERO DE SALIDAS. SEGÚN LA TABLA K.3.4-1 EL SALÓN DE CONVENCIONES ABURRA SUR DEBE TENER 3 SALIDAS6. ANCHO MÍNIMO DE VÍAS DE ACCESO A LAS SALIDAS. SEGÚN LA TABLA K.3.3-2. LOS LUGARES DE REUNIÓN L DEBEN TENER UN ÍNDICE POR PERSONA DE 5mm. COMO ANCHO MINIMO PARA CORREDORES, PUERTAS Y PASAJES DE SALIDA Y 10mm POR PERSONA PARA EL ANCHO DE LAS ESCALERAS. EN EL CASO DE ABURRA SUR EL ANCHO MÍNIMO DE LAS PUERTAS 746,46 x 5mm = 3.732,30mm. 746,46 x 10mm = 7.464,60mm. UPEGUI BUENDIA ARQUITECTOS Carrera 43A# 15 sur 15 - Oficina 404 (Edificio Xerox) Telefax: 317 1797 – e-mail: upeguiarquitectos@gmail.com – Medellín - Colombia