• Share
  • Email
  • Embed
  • Like
  • Save
  • Private Content
GeoVision : Access Control Solutions : Single Door with 2 times schedule
 

GeoVision : Access Control Solutions : Single Door with 2 times schedule

on

  • 429 views

GeoVision : Access Control Solutions : Single Door with 2 times schedule

GeoVision : Access Control Solutions : Single Door with 2 times schedule

Statistics

Views

Total Views
429
Views on SlideShare
429
Embed Views
0

Actions

Likes
0
Downloads
2
Comments
0

0 Embeds 0

No embeds

Accessibility

Categories

Upload Details

Uploaded via as Adobe PDF

Usage Rights

© All Rights Reserved

Report content

Flagged as inappropriate Flag as inappropriate
Flag as inappropriate

Select your reason for flagging this presentation as inappropriate.

Cancel
  • Full Name Full Name Comment goes here.
    Are you sure you want to
    Your message goes here
    Processing…
Post Comment
Edit your comment

    GeoVision : Access Control Solutions : Single Door with 2 times schedule GeoVision : Access Control Solutions : Single Door with 2 times schedule Document Transcript

    • How to Perform a Single Door Access Control with Two Time Schedules Article ID: GV-03-08-12-24 Release Date: 2008/12/24Applied toGV-AS200 Controller SeriesGV-ASManagerSummaryThe document describes how to implement a 2-door module of GV-AS200 Controller in thisspecific application: A single door, equipped with entry and exit readers, has separateEntrance and Exit schedules.In this application, 2-door module of GV-AS200 Controller is required. The inputs of Door Aand Door B on the GV-AS200 module are chained together to work as a single door. The workmode of GV-AS200 module is set to One-Way Traffic, so that separate time schedules can beconfigured for entry and exit readers.Installation and Configuration 1. Set the work mode of GV-AS200 Controller to be One Way Traffic by using GV-ASKeypad or GV-AS200 Configuration Interface.GeoVision Inc. 1 Revision Date: 2008/12/24
    • 2. If the door lock is set to be normally closed (NC): A. Connect the Door + pins of Door A and Door B together to work as a single door. B. Connect the Door – pin of Door A to the negative (—) wire of the door lock. C. Connect the Urgent 1 pin of Door B to the positive (+) wire of the door lock. D. To configure the NC mode on the GV-AS200 module, push two sets of Door Relay Switches upward. Urgent 1 Urgent 2 Door + Door - Urgent 1 Urgent 2 Door + Door - Power + Alarm + Alarm - Power - Alarm + Alarm - Power -GeoVision Inc. 2 Revision Date: 2008/12/24
    • 3. If the door lock is set to be normally open (NO): A. Connect the Door + pins of Door A and Door B together, and connect it to the positive (+) wire of the door lock. B. Connect the Door – pins of Door A and Door B together, and connect it to the negative (—) wire of the door lock. C. To configure the NO mode on the GV-AS200 module, push two sets of Door Relay Switches downward. 4. Connect the entry and exit readers to Wiegand A and Wiegnad B inputs separately on the GV-AS200 module. 5. Configure two time schedules on GV-ASManager, e.g. the schedule of Work Hours and the schedule of Non-Work Hours. For details see Setting Time Schedules in GV-ASManager User’s Manual.GeoVision Inc. 3 Revision Date: 2008/12/24
    • 6. Assign the two schedules to Door A and Door B. In this example, assign the schedule of Work Hours to Door A, and assign the schedule of Non-Work Hours to Door B. For details, see Setting Access Groups in GV-ASManager User’s Manual.After finishing above settings, when a valid card is presented at the entry reader during thedefined time schedule (e.g. Work Hours), the door will open and it will be recorded as “Door AIn” on the GV-ASManager. When the card is presented at the exit reader during the definedtime schedule (e.g. Non-Work Hours), the door will open and it will be recorded as “Door BOut” on the GV-ASManager. Physically Door A and Door B have been chained together towork as a single door application.GeoVision Inc. 4 Revision Date: 2008/12/24