Diseño de losa nervada doblemente armada

1,254

Published on

0 Comments
1 Like
Statistics
Notes
  • Be the first to comment

No Downloads
Views
Total Views
1,254
On Slideshare
0
From Embeds
0
Number of Embeds
4
Actions
Shares
0
Downloads
104
Comments
0
Likes
1
Embeds 0
No embeds

Report content
Flagged as inappropriate Flag as inappropriate
Flag as inappropriate

Select your reason for flagging this presentation as inappropriate.

Cancel
No notes for slide

Transcript

  • 1. Diseñar una losa de edificio cuya planta tipo se presenta a continuación, el mismo será utilizado para oficinas. El concreto empleado será de resistencia f’c=250kg/cm2 y el esfuerzo de fluencia del acero es fy=4200Kg/cm2
  • 2. Pórtico del edificio vista elevación
  • 3. Se asume un espesor de losa de 25cm una loseta a compresión de 5cm, nervios de 10cm, alivianamiento de 30 x 40 de 15cm de altura, dos (2) bloques de 40x20x15 por cada alivianamiento.
  • 4. Tomamos la losa 2-3-A-B ya que tiene una Ln= Luz Mayor y se asocia a criterio de deformación (4m en ambas direcciones), y de igual forma tiene el menor numero de lados con continuidad (Dos de los cuatro lados son continuos). Ln = Luz Mayor Ln = 400 – 25 Ln = 375cm
  • 5. Se calculan los valores a los cuatro (4) bordes de la losa Eje A y 3
  • 6. Determinación de las cargas de diseño en losas -Peso de loseta a compresión = 1x1x0.05xx2400= 120Kg/m2 - Peso del Nervio = 6x0,10x0,20x1x2400= 288Kg/m2 - Alivianamiento = 12x10 = 120Kg/m2 - Peso Propio de la Losa = 528Kg/m2 - Enlucido y Mancilladlo = 1x1x10,04x2200= 88Kg/m2 - Recubrimiento de piso = 1x1x10,02x2200= 44Kg/m2 - Mampostería = 200Kg/m2 - Carga Permanente = 860Kg/m2 - Carga Variable = 250Kg/m2
  • 7. Carga del Diseño U = 1,4 Cp + 1,7 Cv U = 1,4 (860)+ 1,7 (250) U = 1629 Modelo de las Losas de Diseño
  • 8. Formulas para el calculo de momento My- = (0,0001)*(q)*(My-)*(Lx)˄2 My+= (0,0001)*(q)*(My+)*(Lx)˄2 Mx- = (0,0001)*(q)*(Mx-)*(Lx)˄2 Mx+= (0,0001)*(q)*(Mx+)*(Lx)˄2
  • 9. Losa: 1-2-A-B Tabla N° 6 de diseño Lx/Ly → 3/4 = 0,80 My- = (0,0001)*(1629)*(852)*(3)˄2= 1249,12 Kgm My- = 852 My+= (0,0001)*(1629)*(369)*(3)˄2= 540,99 Kgm My+= 369 Mx- = (0,0001)*(1629)*(1120)*(3)˄2= 1642,03 Kgm Mx- = 1120 Mx+= (0,0001)*(1629)*(621)*(3)˄2= 910,45 Kgm Mx+= 621 Losa: 1-2-B-C Tabla N° 2 de diseño Lx/Ly → 3/4 = 0,80 My- = (0,0001)*(1629)*(819)*(3)˄2= 1200,74Kgm My- = 819 My+= (0,0001)*(1629)*(359)*(3)˄2= 526,33Kgm My+= 359 Mx- = (0,0001)*(1629)*(899)*(3)˄2= 1318,02Kgm Mx- = 899 Mx+= (0,0001)*(1629)*(473)*(3)˄2= 693,47Kgm Mx+= 473
  • 10. Losa: 2-3-A-B Tabla N° 6 de diseño Lx/Ly → 4/4 = 1 My- = (0,0001)*(1629)*(839)*(4)˄2= 2186,70 Kgm My- = 839 My+= (0,0001)*(1629)*(428)*(4)˄2= 1115,54 Kgm My+= 428 Mx- = (0,0001)*(1629)*(839)*(4)˄2= 2186,70 Kgm Mx- = 839 Mx+= (0,0001)*(1629)*(428)*(4)˄2= 1115,54 Kgm Mx+= 428 Losa: 2-3-B-C Tabla N° 2 de diseño Lx/Ly → 4/4 = 1 My- = (0,0001)*(1629)*(718)*(4)˄2= 1871,40 Kgm My- = 718 My+= (0,0001)*(1629)*(354)*(4)˄2= 922,67 Kgm My+= 354 Mx- = (0,0001)*(1629)*(597)*(4)˄2= 1556,02 Kgm Mx- = 597 Mx+= (0,0001)*(1629)*(269)*(4)˄2= 701,12 Kgm Mx+= 269
  • 11. Formula para el calculo del acero en losa Para Nervio: b = Base del Nervio d = Altura Útil del Nervio Determinación al positivo (Hierro Inferior) M(+) b = Ancho de loseta a compresión / N°de Nervios
  • 12. Área de Acero Losa: 1-2-A-B
  • 13. Losa: 1-2-B-C
  • 14. Losa: 2-3-A-B
  • 15. Losa: 2-3-B-C

×