Your SlideShare is downloading. ×
  • Like
  • Save
Trab ufcd 8
Upcoming SlideShare
Loading in...5
×

Thanks for flagging this SlideShare!

Oops! An error has occurred.

×

Now you can save presentations on your phone or tablet

Available for both IPhone and Android

Text the download link to your phone

Standard text messaging rates apply
Published

 

  • Full Name Full Name Comment goes here.
    Are you sure you want to
    Your message goes here
    Be the first to comment
    Be the first to like this
No Downloads

Views

Total Views
1,346
On SlideShare
0
From Embeds
0
Number of Embeds
0

Actions

Shares
Downloads
0
Comments
0
Likes
0

Embeds 0

No embeds

Report content

Flagged as inappropriate Flag as inappropriate
Flag as inappropriate

Select your reason for flagging this presentation as inappropriate.

Cancel
    No notes for slide

Transcript

  • 1. Joaquim de Sousa Ferreira nº4941 EFA N.L. 05 29/12/2008 Trabalho prático nº2 de UFCD 8 Imagine que o CINEL precisa de refazer completamente a sua infra-estrutura derede. Actualmente possui, uma rede de classe C e uma cablagem pouco estruturada. Todo o hardware de rede deve ser mudado bem como a localização dos nós decomutação da rede. O CINEL expandiu-se e o seu parque informático aumentou, sendo que temactualmente 420 máquinas para estações de trabalho, 8 servidores de rede, 10impressoras. (o número de switchs será de acordo com o desenho da rede). O pólo técnico vai ser instalado junto à entrada principal à direita. No âmbitodeste trabalho o aluno deverá propor a localização de um pólo técnico secundário quesirva para suportar um dos troços da rede. Para a execução deste trabalho deverá fazer um relatório com a seguinteestrutura: 1. Introdução 2. Objectivos 3. Descrição geral do projecto 4. Layout da rede (sem preocupação com escalas) 5. Marcação da localização dos pólos técnicos e dos bastidores 6. Esquema de endereçamento da rede 7. Indicação do material a utilizar (calha, cabo, esteiras, switchs, etc) 8. Conclusões 9. Recomendações 1
  • 2. O CINEL tratando-se de um centro de formação nas áreas daelectrónica, telecomunicações e informática, deve ter excelentesinstalações, condições de aulas práticas e comunicações, de modoa que os seus formadores e formandos tirem o máximo rendimentodas aulas dadas. Para tal decidiu-se refazer por completo a rede informáticadeste centro. Trata-se de uma rede pouco estruturada, onde umagrande parte da cablagem se encontra dentro da estrutura detecto falso que cobre por completo o centro e que não estavadevidamente acondicionada. Também os switchs encontram-senas próprias salas, em armários de arquivo completamentefechados e pouco ou nada ventilados, o que pode provocar danosnestes equipamentos. Também o parque informático ao nível de computadorespessoais necessita de novas máquinas devido ao desgaste e usointensivo de anos de utilização dos actuais pc´s, por parte deformandos menos cuidadosos, e claro devido à natureza dospróprios cursos ministrados neste centro de formação. 2
  • 3. Os objectivos deste trabalho são:• Reestruturação da actual rede interna – equipamentospassivos, activos e cablagem de rede – e do parque informático,quer para formandos, quer para colaboradores do centro deformação• Criar condições e capacidade da rede para futura expansão,caso se verifique necessário• Upgrade da actual rede de classe C para uma rede de classe B• Rede que possibilite a partilha de impressoras, ficheiros esoftware A obra não tem qualquer restrição orçamental, e com issopodem ser escolhidos os melhores equipamentos sem que sejanecessário olhar aos preços. Apesar disto não foram escolhidosequipamentos topo de gama, mas sim o tipo de máquinas ecablagem com qualidade que suportem as actuais tecnologias edeixem em aberto a possibilidade quer de expansão do parqueinformático, quer no aumento de velocidades de comunicação. O tipo de cablagem escolhido para a rede foi o F/UTP cat.6, quealém de ter um excelente revestimento bom para locais compossíveis interferências eléctricas, possibilita uma largura debanda de cerca de 500 MHz e de comunicações na ordem dos 10Gbps. Serão instaladas fichas RJ 45 nas salas em mais de 10% emrelação ao número de postos de trabalho, para possibilidade deampliação do parque informático, casos de fichas danificadas oupara as necessidades que se possam apresentar nos cursos queaqui são dados. Os equipamentos activos proporcionam a opção da tecnologiaPoE e suporte para VoiP . Em dois dos bastidores de 42U serão instalados os switchsjuntamente com os painéis de patching de 48 portas deixandoespaço para possível ampliação para painéis de voz. Nos outrosdois bastidores ficarão os servidores e router. Num outro bastidorde 22U poderão ficar discos scsi hotswap para armazenagem deficheiros, software e backup em RAID 1+0. É localização do pólo técnico é indicado na sala 19 da planta doedifício, junto à entrada, numa sala pequena onde haverá pouca 3
  • 4. circulação de ar, pelo que é aconselhado um segundo pólotécnico que poderá servir para uma metade dos equipamentos derede e/ou para equipamentos redundantes e/ou de backup. Oideal será juntar mesmo estas duas pequenas salas numa só,“roubando” o espaço intermédio entre elas sendo unido atravésde uma divisória. A rede deverá suportar impressoras partilhadas, pararacionalização de espaço e equipamentos. As impressorasdevem-se localizar em sítios comuns aos vários utilizadores quemais necessitam destas máquinas, pois também deverão sermultifuncionais. Para além disso terão um servidor físico comovirtual dedicado, o que ajudará na administração de acessos àsimpressoras, os serviços autorizados a que utilizador epossibilidade de futuras ampliações. Também serão instaladascalhas técnicas e fichas em salas onde actualmente poderão nãoexistir. Poderão ser usados servidores dedicados, além de um paraimpressoras, de DNS/DHCP, de ficheiros, de software, gestão deconteúdos, de acessos, de backup e de Internet, de modo afacilitar a administração da rede, podendo dar determinadasautorizações e acessos somente a determinados computadores,restringindo os acessos a determinados conteúdos de internet,descargas e instalações de softwares ou outro tipo de ficheiros. Para facilitar de algum modo esta administração poderãoexistir computadores com IP fixo, que serão dirigidas para osformadores, directores e outros colaboradores do CINEL, queconsoante a função que ocupam terão diferentes acessos epermissões dentro da rede. Por exemplo, um computador de umformador poderá ter permissão de instalação de um determinadoprograma e poderá dar a mesma permissão a que oscomputadores dos formandos possam instalar esse mesmosoftware, a partir de um servidor de software ou da Internet. A cablagem que ligará as diversas salas ao pólo técnico,passará por dentro do tecto falso através de calhas suspensas,sendo que as calhas técnicas serão usadas somente nas salas. 4
  • 5. 5
  • 6. 6
  • 7. 7
  • 8. Endereços previstos para a redeSALA Nome de sala Quant. Tipo de Máquina IP`s Nº 1 30 PC Dinâmicos 1 PC formador 172.18.50.100 2 25 PC Dinâmicos 1 PC formador 172.18.50.101 3 6 PC Dinâmicos 1 Impressora 172.18.50.61 4 25 PC Dinâmicos 1 PC formador 172.18.50.102 5 20 PC Dinâmicos 1 PC formador 172.18.50.103 6 25 PC Dinâmicos 1 PC formador 172.18.50.104 1 Impressora 172.18.50.62 7 10 PC Dinâmicos 1 Impressora 172.18.50.63 8 Armazém 1 9 Armazém 2 10 Armazém 3 11 Antigo Pólo Técnico 12 Laboratório 3 30 PC Dinâmicos 1 PC formador 172.18.50.116 13 Armazém 4 14 Armazém 5 15 16 Bar 10 PC Dinâmicos 17 25 PC Dinâmicos 1 PC formador 172.18.50.105 18 25 PC Dinâmicos 1 PC formador 172.18.50.106 19 Pólo Técnico 1 1 Router 172.18.50.1 7 Switch 172.18.50.31 Switch 172.18.50.32 Switch 172.18.50.33 Switch 172.18.50.34 Switch 172.18.50.35 Switch 172.18.50.36 Switch 172.18.50.37 1 Servidor Ficheiros 172.18.50.11 1 Servidor DHCP/DNS 172.18.50.12 1 Servidor Software 172.18.50.13 1 Servidor Web 172.18.50.14 1 PC Dinâmicos 8
  • 9. 20 Secretaria 10 PC Dinâmicos 1 PC 172.18.50.117 1 Impressora 172.18.50.6421 Pólo Técnico 2 7 Switch 172.18.50.38 (proposta) Switch 172.18.50.39 Switch 172.18.50.40 Switch 172.18.50.41 Switch 172.18.50.42 Switch 172.18.50.43 Switch 172.18.50.44 1 Servidor Gestão de Conteúdos 172.18.50.15 1 Servidor Autenticação 172.18.50.16 1 Servidor Impressoras 172.18.50.17 1 Servidor Backups 172.18.50.182223 Sala 1 20 PC Dinâmicos 1 PC formador 172.18.50.10724 25 PC Dinâmicos 1 PC formador 172.18.50.10825 Laboratório 1 25 PC Dinâmicos 1 PC formador 172.18.50.10926 Sala 2 15 PC Dinâmicos 1 PC formador 172.18.50.11027 Laboratório 2 25 PC Dinâmicos 1 PC formador 172.18.50.11128 Reprografia 1 Impressora 172.18.50.652930 25 PC Dinâmicos 1 PC formador 172.18.50.11231 Médico 1 PC Dinâmicos32 Formadores Externos 6 PC Dinâmicos33 Formadores Internos 12 PC Dinâmicos 1 Impressora 172.18.50.6634 Director Financeiro 1 PC Dinâmicos 1 PC 172.18.50.11335 Director de Formação 1 PC Dinâmicos 1 PC 172.18.50.11436 Secretária Director 2 PC Dinâmicos 1 Impressora 172.18.50.6737 Director 1 PC Dinâmicos 1 PC 172.18.50.115 1 Impressora 172.18.50.68 9
  • 10. Máquinas IP`s ROUTERS 172.18.50.1 ao 172.18.50.10 SERVIDORES 172.18.50.11 ao 172.18.50.30 SWITCHS 172.18.50.31 ao 172.18.50.60 IMPRESSORAS 172.18.50.61 ao 172.18.50.99PC FORMADORES 172.18.50.100 ao 172.18.50.200 10
  • 11. Material a utilizar 4 Bastidores 42U 1 Bastidor 22 U 1 Router Cisco 382514 Switchs Cisco Catalyst C3750 48TS14 Painéis de 48 portas p/ cat.610 Réguas de energia c/ interruptor 8 Servidores HP Proliant dl 580 g5 Fichas RJ 45 Calha Técnica Cabo F/UTP cat.6 Conectores para fichas RJ 45 Calha suspensa p/ cabos Bastidor APC NetShelter SX 42U 750 x 1070 Bastidor 22U 11
  • 12. Router Cisco 3825Dados Técnicos:The Cisco 3825 Integrated Services Router is part of the Cisco 3800 Integrated Services RouterSeries which complements the Integrated Services Router Portfolio.The Cisco 3825 IntegratedServices Router provides the following support: •Wire-speed performance for concurrent services such as security and voice , and advanced services at up to half T3/E3 rates •Enhanced investment protection through increased performance and modularity •Enhanced investment protection through increased modularity •Increased density through High-Speed WAN Interface Card Slots (four) •Enhanced Network Module Slot •Support for over 90 existing and new modules •Support for majority of existing AIMs, NMs, WICs, VWICs, and VICs •Integrated GE ports with copper and fiber support •Optional Layer 2 switching support with Power over Ethernet (PoE) (as an option) , supports the 36-port Cisco EtherSwitch module (NMD-36ESW) •Security o On-board encryption o Support of up to 2000 VPN tunnels with the AIM-EPII-PLUS Module o Antivirus defense support through Network Admission Control (NAC) o Intrusion Prevention as well as stateful Cisco IOS Firewall support and many more essential security features •Voice o Analog and digital voice call support o Optional voice mail support o Optional support for Cisco CallManager Express for local call processing in stand alone business for up to 168 IP Phones o Optional support for Survivable Remote Site Telephony support for local call processing in small enterprise branch offices for up to 336 IP phones 12
  • 13. Switch Cisco 3750EDados Técnicos:Deploy secure converged applications while maximizing investment protection for your evolvingnetwork and application requirements. The Cisco Catalyst 3750-E Series with StackWise Plus is anenterprise-class line of stackable wiring closet switches. Combining 10/100/1000 and Power overEthernet (PoE) configurations with upgradeable 1 Gigabit Ethernet to 10 Gigabit Ethernet uplinks,Catalyst 3750-E switches help enhance worker productivity by enabling applications such as IPtelephony, wireless, and video.Key features include: •TwinGig converter module for migrating uplinks from 1 Gigabit Ethernet (SFP) to 10 Gigabit Ethernet (X2) •Configurations with up to 15.4 watts (Class 3) of PoE on all 48 ports •StackWise Plus for ease of use and resiliency with 64 Gbps stacking •Field replaceable and upgradable power supplies and fan tray •Wire rate performance with 68 Gbps nonblocking switching fabric •Multicast routing, IPv6 routing, and access control list in hardware •Out-of-band Ethernet management port along with RS-232 console port •Full backward compatibility with the Catalyst 3750 SeriesThe Cisco Catalyst 3750-E Series is orderable with two feature sets: •The IP Base feature set includes advanced QoS, security, and basic routing functionality. •The IP Services feature set provides a richer set of enterprise-class features, including advanced hardware-based IP unicast and multicast routing as well as Virtual Route Forwarding (VRF), and policy-based routing (PBR). 13
  • 14. Servidores HP Proliant DL 580Dados Técnicos: General Model Name HP ProLiant DL580 G5 Chassis Form Factor 4U Rackmount Memory RAM (max) 128 GB RAM (installed) 8 GB RAM Technology DDR2 SDRAM Cache Memory (installed) 8 MB Operating System OS Provided No Operating System Installed Optical Drive Information CD/DVD Type DVD-ROM Processor Chipset Type Intel 7300 Processor Manufacturer Intel Processor Type Xeon QC Processor Speed 2.4 GHz # Processors Installed 4 # Processors Supported 4 Processor Model Number E7340 Processor Upgradability Upgradable Protocols Networking Protocol Gigabit Ethernet Storage Hard Drive Interface Serial Attach SCSI (SAS) Hard Drive Interface SATA Storage Controller Type Smart Array P400i Hard Drive Capacity 0 GB Floppy Type No Floppy Drive Video 14
  • 15. Video RAM (installed) 32 MBExternal Resolution (max) 1280 x 1024 Video Card ATI ES1000 Actual Weight 100.00 lb(s) SAS Controllers: Smart Array E200 Controller PCC # 6912182 - 411508-B21 - HP Smart Array E200 / 128 BBWC Controller PCC # 5353921 - 351580-B21 - 128-MB BBWC (Battery-Backed Write Cache) Enabler NOTE: Supports the Smart Array E200 Controller, Smart Array 641 Controller, Smart Array 642 Controller. PCC # 7701504 - 435129-B21 - HP Smart Array E500 / 256MB Controller PCC # 6834356 - 405132-B21 - HP Smart Array P400 / 256MB Controller PCC # 6833601 - 411064-B21 - HP Smart Array P400 / 512MB BBWC Controller PCC # 6834364 - 405148-B21 - 512MB DDR BBWC Upgrade NOTE: For Smart Array P400 Controller only. PCC # 6834233 - 383280-B21 - Battery-backed write cache upgrade NOTE: For Smart Array P400 Controller only. Compatibility Notes PCC # 6834444 - 417836-B21 - Smart Array P400 Battery Attach Kit NOTE: This option kit contains a 24" battery cable and adhesive material for installing a battery into the server if a Smart Array P400 is integrated outside of the factory. For all solutions, please refer to the server QuickSpecs and Users Manual for detailed installation instructions. PCC # 6128371 - 337972-B21 - HP Smart Array P600 / 256 BBWC Controller PCC # 7378217 - 381513-B21 - HP Smart Array P800 / 512 BBWC Controller PCC # 7557477 - 416096-B21 - HP SC44Ge Host Bus Adapter PCC # 6265991 - 347786-B21 - HP 8 Internal Port SAS HBA with RAID PCC # 5353921 - 351580-B21 - 128-MB BBWC (Battery-Backed Write Cache) Enabler NOTE: Supports the Smart Array 641, and Smart Array 642 Controller. PCC # 5544023 - 374654-B21 - 64-Bit / 133-MHz Single Channel Ultra320 SCSI HBA G2 Contents Server, software, documentation 8GB PC2-5300 DDR2 667MHz SDRAM, expandable to 128GB. Memory Notes There are sixteen memory slots. 15
  • 16. Note: 128GB maximum achieved with use of four memory cartridges and (32) 4 GB Memory Modules Mfr. Item # 397411-B21 - PCC Item# 6886359 - HP 2GB PC2- 5300 667MHz Fully Buffered Mfr. Item # 397413-B21 - PCC Item# 6886367 - HP 4GB PC2- 5300 667MHz Fully Buffered Mfr. Item # 397415-B21 - PCC Item# 6911753 - HP 8GB PC2- 5300 667MHz Fully Buffered Video memory: 32MB There is no operating system installed; compatible operating systems include: Windows Server 2003 O/S Notes Red Hat Enterprise Linux SuSE Linux Enterprise Server Novell NetWare Sun Solaris Intel Platform Edition VMware Virtualization SoftwarePhysical Dimensions 6.94"h x 19"w x 26.5"d Expansion slots: (4) full length PCI-Express x8, (1) full length PCI-Express x4, (3) half length PCI-Express x4, Note: Optional card adds (3) PCI-X or (3) PCI-Express x8 Expansion bays: (16) 2.5", (1) Slimline DVD Storage Controller: HP Smart Array P400i embedded / 512MB Cache Ports/Connectors I/O: (2) Video (1 front) (6) USB 2.0 (2 front, 2 internal) (1) Serial (2) PS/2 (2) RJ-45 (1) iLO Power supply: Four (4) redundant Power Notes Cooling: (6) hot-plug redundant fans This product is subject to our return policy. Please see our Returns Policy complete return policy for details. Warranty - Labor 3 Years Warranty - Parts 3 Years 16
  • 17. Painéis 48 portas – STP cat.6 Painéis de energia c/interruptorDiscos SCSI hotswap Fichas RJ 45Cabo F/UTP cat.6 Conectores RJ 45 17
  • 18. • Necessidade de colocação de chão falso em ambos os pólostécnicos.• Necessidade de instalação de aparelhos de ar condicionado emambos os espaços, aparelhos estes em número suficiente paramanter os locais bem refrigerados e para o caso de falha de algumdeles.• Recomenda-se o fecho por completo (tanto interna, comoexternamente) das janelas que irão servir o Pólo Técnico, de formaa prevenir intempéries, infiltrações e/ou humidade. Caso não sejapossível o fecho das janelas desta forma, recomenda-se entãosomente o isolamento interno.• A localização do 2º Pólo Técnico, é aconselhada na sala 21 naplanta do edifício. Este local poderá servir para alojar parte dosservidores da rede ou o sistema de backup.• Sugere-se mesmo a união destes dois locais, através de porexemplo, a montagem de uma divisória, de modo a fazer um só PóloTécnico.• Outra possibilidade de localização do 2º Pólo Técnico, poderiaser na sala 9 da planta do CINEL, com um 2º sistema que terialigados a si a metade superior do CINEL (salas 13,16,18 comolimite), com o 1º Pólo Técnico da sala 19 a prestar serviços à parteinferior do edifício, ficando ligados entre si, através de fibra óptica,com um switch em cada um dos pólos. Por sua vez poderiam estartambém ligados separadamente ao router.• Poderão ser também aproveitados os routers wireless que seencontram instalados no edifício e que facilitam a comunicaçãoentre portáteis e a rede, sendo que estes devem também terrestrições de acessos.• Uso de uma firewall entre o router e os dois primeiros switchs 18