Your SlideShare is downloading. ×
0
GPO Customer Presentation
GPO Customer Presentation
GPO Customer Presentation
GPO Customer Presentation
GPO Customer Presentation
GPO Customer Presentation
GPO Customer Presentation
GPO Customer Presentation
GPO Customer Presentation
GPO Customer Presentation
GPO Customer Presentation
GPO Customer Presentation
GPO Customer Presentation
GPO Customer Presentation
GPO Customer Presentation
GPO Customer Presentation
GPO Customer Presentation
GPO Customer Presentation
GPO Customer Presentation
GPO Customer Presentation
GPO Customer Presentation
GPO Customer Presentation
GPO Customer Presentation
GPO Customer Presentation
GPO Customer Presentation
GPO Customer Presentation
GPO Customer Presentation
GPO Customer Presentation
GPO Customer Presentation
GPO Customer Presentation
GPO Customer Presentation
GPO Customer Presentation
GPO Customer Presentation
GPO Customer Presentation
GPO Customer Presentation
GPO Customer Presentation
GPO Customer Presentation
GPO Customer Presentation
GPO Customer Presentation
GPO Customer Presentation
GPO Customer Presentation
GPO Customer Presentation
GPO Customer Presentation
GPO Customer Presentation
GPO Customer Presentation
GPO Customer Presentation
GPO Customer Presentation
GPO Customer Presentation
GPO Customer Presentation
GPO Customer Presentation
GPO Customer Presentation
GPO Customer Presentation
GPO Customer Presentation
GPO Customer Presentation
GPO Customer Presentation
Upcoming SlideShare
Loading in...5
×

Thanks for flagging this SlideShare!

Oops! An error has occurred.

×
Saving this for later? Get the SlideShare app to save on your phone or tablet. Read anywhere, anytime – even offline.
Text the download link to your phone
Standard text messaging rates apply

GPO Customer Presentation

779

Published on

METTLER TOLEDO Gas Analytics

METTLER TOLEDO Gas Analytics

0 Comments
0 Likes
Statistics
Notes
  • Be the first to comment

  • Be the first to like this

No Downloads
Views
Total Views
779
On Slideshare
0
From Embeds
0
Number of Embeds
1
Actions
Shares
0
Downloads
0
Comments
0
Likes
0
Embeds 0
No embeds

Report content
Flagged as inappropriate Flag as inappropriate
Flag as inappropriate

Select your reason for flagging this presentation as inappropriate.

Cancel
No notes for slide
  • Solutions: Sensor Software / system integration Services LAB (blue): laboratories in many different industries products used for research, DD, QC has become much more sizeable in recent years IND (green) same customer base – however on the manufacturing und e.g. pharma production side. cover solutions across the plant: production, packaging, logistics RET (red): in food retail – provide solutions for the management of fresh goods Important value propositions to your customers: Accelerate processes (DD) Increase efficiency (LAB) Improve product quality (IND) Comply with regulations
  • Aside from offering instruments and related software, we offer also an increasing array of services . We are in the midst of a successful transition from a traditional service definition to one of value added services. The foundation is our traditional service business with a significant contract / maintenance business / repair / calibration Now, we are moving decisively into regulatory compliance services, e.g. pharma FDA: IQ, EQ, OQ, PQ Also, we have validation specialists that can assist in all aspects of process validation. Validation methods ensure 21 CFR part 11 conformity . Validation protocols guarantee monitored user management and safe data management. Service is 20% of sales. Many years good growth , slowed down as a result of economy  bring it back to good growth.
  • ISM is a system for the future and for today., Today ISM gives you a lot of benefits by making all the handling operations much simpler, more error-free and more efficient. Starting with the installation of the sensor. After connecting the sensor to the instrument the ISM system will perform it own configuration. Calibration can be done in a lab or maintenance shop, much easier than at the measuring point.. The ISM will also help you to reduce the amount trouble shootings. In all this steps the ISM function will guide you, save costs and a lot of valuable time. For the future ISM gives our customers a system that is flexible for and expendable.
  • Lets take a look at how iSense works.
  • Where have the amperometric systems been successful in industrial applications? I would like to group the applications after the background gases that are present in the gas mixture. In the first group, we have blanketing applications where the only other gas present in the gas mixture next to Oxygen is Nitrogen. In these applications, mainly storage and packaging, long term signal stability is key. Here, the important feature of the one-point air calibration is relevant. With only air necessary as calibration gas, the whole characteristic line of the sensor can be quickly verified, and with the AirCheck solution, this can be even done automatically. In the second group, we have Inertization applications, with may be flammable solvents in the background composition. There, safety is a key issue, and this is where the ATEX zone 0 and FM class 1 Div 1 hazardous area certifications are necessary. Both the InPro 6850i G and InPro 6900i G have these certification so centrifuge inertization with oxygen measurement directly in the centrifuge is possible In the third group, Background gas composition is changing with the process conditions. This can be the case in vent collect headers for example. In off-gas monitoring, process conditions are sometimes changing fast. For these applications, the high membrane selectivity and fast response time of the sensor is key.
  • Transcript

    • 1. Oxygen Measurement for Process Analytics Presentation Urdorf, January 2010
    • 2. Agenda <ul><li>Introduction </li></ul><ul><ul><li>Mettler-Toledo Process Analytics </li></ul></ul><ul><ul><li>Why Mettler-Toledo? </li></ul></ul><ul><li>Oxygen Measurement Key Drivers </li></ul><ul><li>Amperometric Measurement Solutions </li></ul><ul><li>System overview </li></ul><ul><li>Applications & Success stories </li></ul><ul><li>Summary and outlook </li></ul>
    • 3. Our Group METTLER TOLEDO is a global manufacturer and marketer of precision instruments for use in the laboratories, manufacturing, and food retailing. <ul><li>Worldwide presence </li></ul><ul><li>10’000 employees </li></ul><ul><li>Sales approx. USD 2 billion </li></ul>
    • 4. Customer Processes <ul><li>Solutions to support customer processes </li></ul><ul><li>Accelerate processes </li></ul><ul><li>Improve product quality </li></ul><ul><li>Increase efficiency </li></ul><ul><li>Comply with regulations </li></ul>Customer Benefits Laboratory Solutions Industrial Solutions Retail Solutions R&D Drug Discovery Quality Control Retail Logistics Packaging Manufacturing
    • 5. Divisional Structure Process Analytics Industrial Weighing Laboratory Division Product Inspection Retail Solutions Laboratory Solutions Industrial Solutions Retail Division
    • 6. Value Proposition Process Analytics Measuring key analytical parameters to control production processes:
    • 7. Applications Around Customer Processes Plant Water Source Coagulation / Reverse Osmosis/ Demineralizers Cooling Towers/ Boilers Waste Water Recycle & Discharge Downstream Processing Preparation Reactions Waste Water Water Preparation Process Oxygen Gas Phase
    • 8. Complete Product Offering DO/O 2 /O 3 Housing TOC Turb Cond pH CO 2 High-end Advanced Basic
    • 9. Service Solutions Service XXL Customer Benefits Validation methods and protocols ensure process reproducibility, user monitoring and safe data management. Documented equipment qualification ensures compliance with quality assurance systems such as GLP, GMP and ISO. Calibration processes ensure accurate, reliable and traceable results. Proactive maintenance maximizes uptime and productivity. User training ensures equipment knowledge which leads to safer working processes. Maintenance and Support Calibration Regulatory Compliance Vali- dation Maintenance and Support Calibration Qualification Vali- dation Support Improved service tools enhance customer processes
    • 10. Oxygen Analytics Around Your Process Storage & Environment Upstream & Processing Recovery & Waste Downstream & Purification <ul><li>Headspace blanketing </li></ul><ul><li>Inerting </li></ul><ul><li>Spray Towers </li></ul><ul><li>Milling </li></ul><ul><li>Wort Areation </li></ul><ul><li>Extruder </li></ul><ul><li>Centrifuge Inertization </li></ul><ul><li>Cristallisation </li></ul><ul><li>Deodorization </li></ul><ul><li>Air Scrubber </li></ul><ul><li>Gas Reclaim </li></ul><ul><li>CO2 Recovery </li></ul><ul><li>Tank Storage </li></ul><ul><li>Packaging </li></ul><ul><li>Flushing </li></ul><ul><li>Transportation </li></ul><ul><li>Combustion </li></ul>
    • 11. Why METTLER TOLEDO? <ul><li>Extensive application expertise of your manufacturing processes </li></ul><ul><li>Broad coverage of Liquid & Gas Analytical Measurement parameters </li></ul><ul><li>Comprehensive System Offering for in-line measurement of key analytical measurement solutions </li></ul><ul><li>Vendor-independent supplier of System Integration solutions with </li></ul><ul><ul><li>PROFIBUS™, </li></ul></ul><ul><ul><li>FOUNDATION™ Fieldbus and </li></ul></ul><ul><ul><li>HART™ communication </li></ul></ul>METTLER TOLEDO Process Analytics is your partner of choice for reliable and innovative Liquid & Gas measurement solutions
    • 12. Agenda <ul><li>Introduction </li></ul><ul><li>Oxygen Measurement Key Drivers </li></ul><ul><li>Amperometric Measurement Solutions </li></ul><ul><li>System overview </li></ul><ul><li>Applications & Success stories </li></ul><ul><li>Summary and outlook </li></ul>
    • 13. Reasons for Gas Measurement <ul><li>Prevent product degradation to: </li></ul><ul><ul><li>Increase Yield </li></ul></ul><ul><ul><li>Stabilize taste </li></ul></ul><ul><ul><li>Extend shelf life </li></ul></ul>Oxygen control has a direct impact on the quality and the efficiency of your process Quality Safety Environmental protection <ul><li>Prevent explosive conditions with </li></ul><ul><ul><li>Solvent </li></ul></ul><ul><ul><li>Dust </li></ul></ul><ul><ul><li>Flammable products </li></ul></ul><ul><li>Prevent incomplete combustion </li></ul><ul><ul><li>Manufacturing off gas </li></ul></ul><ul><ul><li>Flue gas </li></ul></ul><ul><ul><li>Emissions monitoring </li></ul></ul>
    • 14. Drivers for Efficient Oxygen Measurement <ul><li>Real-time, fast measurement as close as possible to the process itself, even in hazardous areas </li></ul><ul><li>Stable and reliable signal output </li></ul><ul><li>Low sensitivity to process conditions and background gases </li></ul><ul><li>Low cost of ownership and fast Return on Investment </li></ul><ul><li>High dynamic range with maximum accuracy </li></ul><ul><li>FM and ATEX approvals </li></ul><ul><li>Maximized maintenance intervals through maximum sensor performance and reliable diagnostics </li></ul><ul><li>Temperature & Pressure resistance, and insensivity to moisture and dust </li></ul>METTLER TOLEDO: efficient and innovative in-line solutions through technology leadership and application expertise Market needs Product requirements
    • 15. Challenges for In-line Measurement <ul><li>High resistance against process and environmental conditions: </li></ul><ul><ul><li>Pressure </li></ul></ul><ul><ul><li>Temperature </li></ul></ul><ul><ul><li>Moisture </li></ul></ul><ul><ul><li>Dust, particles </li></ul></ul>In-Line Measurement Robustness Reliability Accuracy Continuous <ul><li>Minimum system complexity to avoid sources of failure: </li></ul><ul><ul><li>Sensing element </li></ul></ul><ul><ul><li>Process connection </li></ul></ul><ul><ul><li>HMI </li></ul></ul><ul><li>Minimum interferences with other components </li></ul><ul><li>Linearity </li></ul><ul><li>Repeatability </li></ul><ul><li>Maximum process availability: </li></ul><ul><ul><li>Replacement </li></ul></ul><ul><ul><li>Calibration </li></ul></ul><ul><ul><li>System maintenance </li></ul></ul>In-Line Oxygen measurement for your process results into better data transparency and improvement opportunities
    • 16. Inerting Methods <ul><li>Pressure monitoring </li></ul><ul><li>A positive pressure will prevent oxygen (air) from entering the process </li></ul><ul><li>Flow monitoring </li></ul><ul><li>Inert gas is added at a calculated flow rate for the whole process (timed volume) </li></ul><ul><li>Oxygen monitoring and control </li></ul><ul><li>Based upon the real oxygen level, inertization gas is only purged if an upper intervention limit is exceeded </li></ul>METTLER TOLEDO Approach With Oxygen monitoring, inert gas consumption can be reduced by 70% of conventional costs Conventional Approach
    • 17. Which O 2 Level? <ul><li>Upon reaching the upper intervention limit: inert gas is purged to the process </li></ul><ul><li>If reaching the lower intervention limit: Nitrogen purging is stopped </li></ul><ul><li>The lower intervention limit is for fail safety reasons to ensure that the measuring system is working </li></ul>Oxygen control directly into your process is the combination of improved safety with lower operating costs Limiting oxygen concentration (LOC): the lowest oxygen concentration supporting flame propagation
    • 18. Agenda <ul><li>Introduction </li></ul><ul><li>Oxygen Measurement Key Drivers </li></ul><ul><li>Amperometric Measurement Solutions </li></ul><ul><li>System overview </li></ul><ul><li>Applications & Success stories </li></ul><ul><li>Summary and outlook </li></ul>
    • 19. 3-Electrode Polarographic Cell Cathode : O 2 + 2H 2 O + 4e - -> 4OH − Anode 4OH - -> O 2 + 2H 2 O + 4e - Reference: AgCl ↔ Ag + + Cl - Electrode reactions InPro 6800 & InPro 6850i Series - Instruction Manual Inner Body Membrane Body O 2 O 2 O 2 R Membrane Cathode Glass insulator Reference Electrolyte Polarization voltage NTC 22k  Anode - + I Current U
    • 20. Polarographic Curve <ul><li>This potential falls in the middle of the plateau region, where the relationship between current and pO2 becomes linear </li></ul><ul><li>For the most applications it is sufficient to perform a one-point calibration in air (20,95 %Vol O 2 ). The residual current in inert gas (N 2 , He) is usually negligible (20 - 30 pA). </li></ul>A constant polarization voltage (675mV) is applied to the cell that induces the reduction of oxygen at the cathode. PRO-Net Library, Theory of Polarographic Oxygen Sensors
    • 21. Amperometric Oxygen Measurement <ul><li>Dissolved oxygen measurement in Chemical, Pharma, BioPharma and Food and Beverage Industry is prevailingly amperometric because: </li></ul><ul><ul><li>Robust design </li></ul></ul><ul><ul><li>Proven technology </li></ul></ul><ul><ul><li>Extensive portfolio for a wide application coverage </li></ul></ul><ul><ul><li>Wide temperature range </li></ul></ul><ul><ul><li>Sterilizable and autoclavable versions available </li></ul></ul><ul><ul><li>Certified products </li></ul></ul><ul><ul><li>Easy and fast maintenance </li></ul></ul>Amperometric oxygen measurement is a proven technology in harsh applications
    • 22. Sensor Design Membrane body Cap sleeve Retainer nut Replaceable inner body Sensor shaft Connector (IP68) Pg 13.5 sleeve <ul><li>Easy and fast replacement </li></ul><ul><li>Oxygen selective membrane </li></ul><ul><li>Teflon® surface </li></ul>Available in: <ul><li>316L </li></ul><ul><li>C22 Hastelloy ® </li></ul><ul><li>Titanium (on request) </li></ul>Easy and fast maintenance by design
    • 23. Sensor Performance: Response Time 98% Fast Oxygen response time translates into better decision-making into your process in case of sudden change in process conditions
    • 24. Agenda <ul><li>Introduction </li></ul><ul><li>Oxygen Measurement Key Drivers </li></ul><ul><li>Amperometric Measurement Solutions </li></ul><ul><li>System overview </li></ul><ul><ul><li>System Offering </li></ul></ul><ul><ul><li>Sensor </li></ul></ul><ul><ul><li>Transmitter </li></ul></ul><ul><ul><li>Housing </li></ul></ul><ul><li>Applications & Success stories </li></ul><ul><li>Summary and outlook </li></ul>
    • 25. O 2 Gas Product Offering Transmitter Housing Sensor AirCheck Enhanced Basic
    • 26. Technical Facts – Pressure Compensation M400 solution 98% N 2 , 2% O 2 @ 1 bar 2.4 % O 2 1.2 bar 2.0 % O 2 M420 & M700 solution 98% N 2 , 2% O 2 @ 1 bar 2.4 % O 2 1.2 bar 2.0 % O 2 0/4..20 mA 0/4..20 mA 0/4..20 mA 0/4..20 mA Process pressure must be accounted for either in the DCS or in the transmitter
    • 27. ISM ® : A Future-proof Maintenance Concept <ul><li>ISM optimizes: </li></ul><ul><ul><li>The installation </li></ul></ul><ul><ul><li>The configuration </li></ul></ul><ul><ul><li>The documentation, traceability and handling </li></ul></ul><ul><ul><li>...and helps reducing loop maintenance costs </li></ul></ul>Install Configure Calibrate Document Troubleshoot Replace ISM ® is METTLER TOLEDO’s solution for Advanced Process Analytics
    • 28. ISM Maintenance Concept
    • 29. Key Success Factors <ul><li>Robustness </li></ul><ul><ul><li>Simple system components for more reliability </li></ul></ul><ul><li>Direct installation </li></ul><ul><ul><li>No interferences with Moisture, dust an solvents </li></ul></ul><ul><li>Easy maintenance </li></ul><ul><ul><li>2-minute maintenance without specialist know how </li></ul></ul><ul><li>Air Check TM </li></ul><ul><ul><li>self check of the system accuracy for improved drift control </li></ul></ul><ul><li>Redundancy </li></ul><ul><ul><li>Higher process safety thanks easy parallel measurement at minimized cost </li></ul></ul>The five key differentiators show the clear advantages of INGOLD’s inline gas measurement capability
    • 30. Robustness <ul><li>Is your sampling system robust and reliable? </li></ul><ul><li>Amperometric METTLER TOLEDO sensors and process connections allow for direct installation in aggressive environment with </li></ul><ul><ul><li>Vibrations </li></ul></ul><ul><ul><li>High Moisture </li></ul></ul><ul><ul><li>Temperature changes </li></ul></ul><ul><ul><li>Aggressive environment </li></ul></ul><ul><li>Your Benefit </li></ul><ul><ul><li>Less parts to maintain (no sampling system) </li></ul></ul><ul><ul><li>Fast and efficient maintenance </li></ul></ul><ul><ul><li>Enhanced system reliability </li></ul></ul>Typical sampling unit INGOLD’s simple and rugged amperometric solution can be installed in harsh environments
    • 31. Direct Installation <ul><li>No need for sample conditioning </li></ul><ul><ul><li>INGOLD’s amperometric sensors are insensitive to </li></ul></ul><ul><ul><ul><li>Moisture </li></ul></ul></ul><ul><ul><ul><li>Particles </li></ul></ul></ul><ul><ul><ul><li>Solvents </li></ul></ul></ul><ul><ul><ul><li>Most organic and inorganic gases </li></ul></ul></ul><ul><li>Your Benefit </li></ul><ul><ul><li>Low installation costs </li></ul></ul><ul><ul><li>Less components to maintain </li></ul></ul><ul><ul><li>Low risk of system errors </li></ul></ul>Only inline installation offers direct oxygen monitoring in the process
    • 32. Easy Maintenance <ul><li>Simple and easy </li></ul><ul><ul><li>Only one component to maintain </li></ul></ul><ul><ul><li>Sensor retractable without process interruption </li></ul></ul><ul><ul><li>Replacement within a minute </li></ul></ul><ul><ul><li>2-minutes maintenance thanks to the easy to use membrane body concept </li></ul></ul><ul><ul><li>No specialist know how necessary </li></ul></ul><ul><ul><li>No other calibration gas than air is necessary </li></ul></ul><ul><li>Your Benefit </li></ul><ul><ul><li>No process down times </li></ul></ul><ul><ul><li>Reduced risk of handling errors </li></ul></ul><ul><ul><li>Minimized maintenance effort </li></ul></ul>Permanent system availability due to the easy and fast maintenance or replacement
    • 33. Enhanced Reliability with AirCheck™ <ul><li>Sensor is pneumatically retracted in service position. </li></ul><ul><li>Air flow is supplied to the housing rinsing chamber through the AirCheck </li></ul><ul><li>If the air value is stable and within the preset limits, the sensor is inserted into the process </li></ul><ul><li>If the air value is out of the specified range, an alarm occurs and is transmitted via relay to the PLC. </li></ul>Unique new “Safety” solution: Check the air current of the oxygen sensor at any time with AirCheck™: Nitrogen Air Coming Q1 10 Vent AirCheck™ allows to regularly check the integrity of the measurement system
    • 34. Redundancy <ul><li>Redundancy of the sensor system with dual channel Transmitters </li></ul><ul><ul><li>Permanent self-control of the system </li></ul></ul><ul><ul><li>Fail safety </li></ul></ul>Redundancy <ul><li>Your Benefit </li></ul><ul><ul><li>Continuous measurement, at reasonable cost, even if one system is in standby or maintenance position </li></ul></ul>The attractive price/performance of a loop allows for cost efficient redundant measurement
    • 35. Return On Investment (ROI) Payback period 4 Months 80% cost saving
    • 36. Agenda <ul><li>Introduction </li></ul><ul><li>Oxygen Measurement Key Drivers </li></ul><ul><li>Amperometric Measurement Solutions </li></ul><ul><li>System overview </li></ul><ul><ul><li>System Offering </li></ul></ul><ul><ul><li>Sensor </li></ul></ul><ul><ul><li>Transmitter </li></ul></ul><ul><ul><li>Housing </li></ul></ul><ul><li>Applications & Success stories </li></ul><ul><li>Summary and outlook </li></ul>
    • 37. Oxygen Sensor Portfolio ≤ ±[1% +5 ppm] ≤ ±[1% + 3 ppb] ≤ ±[1% + 300ppb] ≤ ±[1% + 0.1 Vol%] Accuracy <ul><li>ATEX II 1/2GD EEX ia IIC T6/T5/T4/T3 </li></ul><ul><li>FM IS/I, II, III / 1 / ABCDEFG / T6 </li></ul>Certification 0 .. 25% O2 0 .. 100% O2 0 .. 100% O2 0 ..100% O2 Measurement range 5 ppm 50 ppm 300 ppm 300 ppm Detection Limit <ul><li>Chemical </li></ul><ul><li>Petrochemical </li></ul><ul><li>Pharmaceutical </li></ul><ul><li>Food & Beverages </li></ul><ul><li>New Dynamic Lifetime Indicator (DLI) for Gas </li></ul><ul><li>New anode/cathode assembly </li></ul><ul><li>Guard ring as Oxygen Scavenger </li></ul>InPro 6900i G <ul><li>Brewing </li></ul><ul><li>Food & Beverages </li></ul><ul><li>Chemical </li></ul><ul><li>Petrochemical </li></ul><ul><li>Pharmaceutical </li></ul><ul><li>Food & Beverages </li></ul><ul><li>Chemical </li></ul><ul><li>Petrochemical </li></ul><ul><li>Pharmaceutical </li></ul><ul><li>Food & Beverages </li></ul>Typical Applications <ul><li>New Dynamic Lifetime Indicator (DLI) for Gas </li></ul><ul><li>New electrolyte monitor </li></ul><ul><li>hygienic design </li></ul><ul><li>CIP resistant </li></ul><ul><li>4-electrode design for low drift </li></ul>InPro 6950i G InPro 6850i G InPro 6800 G <ul><li>New Dynamic Lifetime Indicator (DLI) for Gas </li></ul><ul><li>New electrolyte monitor </li></ul><ul><li>3-electrode design for low drift </li></ul><ul><li>AgCl free anode for lower drift </li></ul><ul><li>Application specific membrane bodies </li></ul>Features
    • 38. Why we do not need Sample Conditioning <ul><li>Robustness of the electrochemical system </li></ul><ul><ul><ul><li>Vibrations </li></ul></ul></ul><ul><ul><ul><li>Pressure changes </li></ul></ul></ul><ul><ul><ul><li>Selection of materials </li></ul></ul></ul><ul><li>Membrane technology </li></ul><ul><ul><ul><li>The measurement system is separated from the process with a oxygen permeable membrane </li></ul></ul></ul><ul><ul><ul><li>Big organic and inorganic molecules can not pass the membrane </li></ul></ul></ul><ul><ul><ul><li>The outer PTFE layer withstands harshest process conditions </li></ul></ul></ul><ul><ul><ul><li>Thanks to the sensor design, membrane clogging is minimized </li></ul></ul></ul><ul><li>Sensor design </li></ul><ul><ul><ul><li>The small and compact sensor design allows for direct installation in vessels or pipes </li></ul></ul></ul>
    • 39. Agenda <ul><li>Introduction </li></ul><ul><li>Oxygen Measurement Key Drivers </li></ul><ul><li>Amperometric Measurement Solutions </li></ul><ul><li>System overview </li></ul><ul><ul><li>System Offering </li></ul></ul><ul><ul><li>Sensor </li></ul></ul><ul><ul><li>Transmitter </li></ul></ul><ul><ul><li>Housing </li></ul></ul><ul><li>Applications & Success stories </li></ul><ul><li>Summary and outlook </li></ul>
    • 40. Gas-Phase Oxygen Transmitters Cl1 Div 2 Cl1 Div 1* *pending Pressure input Pressure input Pressure input InPro 6800 G, InPro 6850i G, InPro 6900i G, InPro 6950i G InPro 6800 G, InPro 6850i G, InPro 6900i G, InPro 6950i G InPro 6800 G, InPro 6850i G, InPro 6900i G, InPro 6950i G Single Channel Single Parameter Mixed-mode input 2-Wire, loop powered M420 Single Channel Multi Parameter Mixed-mode input Dual Channel Multi Parameter Mixed-mode input 4-Wire 4-Wire M400 M700
    • 41. M400 Feature Overview Password protection (5 digit, numeric) <ul><li>8 languages: </li></ul><ul><li>English </li></ul><ul><li>Spanish </li></ul><ul><li>French </li></ul><ul><li>German </li></ul><ul><li>Italian </li></ul><ul><li>Portuguese </li></ul><ul><li>Russian </li></ul><ul><li>Japanese </li></ul>Quick Setup Mode Large backlit display (4 text lines) USB port M400: Mixed-mode input: TB3 for conventional sensors (ChA) TB4 for ISM sensor (ChB) Variable power supply 100..240VAC; 20..30V DC <ul><li>Plug and Measure </li></ul><ul><li>Dynamic Lifetime Indicator (DLI) </li></ul><ul><li>Adaptive Calibration Timer (ACT) </li></ul><ul><li>CIP/SIP counter </li></ul><ul><li>Calibration history </li></ul>4 x (0) 4-20mA Outputs 6 Relays Multi parameter unit O2, pH, pH ISFET, Cond, CondInd FM Cl1 Div 2 / Atex Zone 2 (except M400 Type 1 Cond Ind) IP 65 The M400, proven technology for ease of use, ruggedness and advanced ISM diagnostics
    • 42. M420 Feature Overview 5 x Password protection (4 digit, numeric) FM Cl1 Div 2 (pending) FM Cl1 Div 1 (pending) /ATEX Zone 1 <ul><li>26 Quick Setup Guides </li></ul><ul><li>6 manuals: </li></ul><ul><li>English </li></ul><ul><li>Spanish </li></ul><ul><li>French </li></ul><ul><li>German </li></ul><ul><li>Portuguese </li></ul><ul><li>Russian </li></ul>Wide backlit display (scrolling text line) IrDA service port M420: Mixed-mode input: conventional sensors OR ISM sensors <ul><li>Plug and Measure </li></ul><ul><li>Dynamic Lifetime Indicator (DLI) </li></ul><ul><li>Adaptive Calibration Timer (ACT) </li></ul><ul><li>CIP/SIP counter </li></ul><ul><li>ISM Data </li></ul>pending OUT2 option: Up to 2 configurable current outputs (primary or secondary value) Key features of the M420 are the integration of ISM ® functionalities and the unique mixed-mode input feature
    • 43. M700 Feature Overview Optional selectable software functions FDA 21CFR Part11 compliance Data logger FM Cl1 Div 2 FM Cl1 Div 1 / ATEX Zone 1 IP65/NEMA 4X <ul><li>6 Languages: </li></ul><ul><li>English </li></ul><ul><li>Spanish </li></ul><ul><li>French </li></ul><ul><li>German </li></ul><ul><li>Italian </li></ul><ul><li>Swedish </li></ul>Wide backlit display (scrolling text line) <ul><li>Multi Channel </li></ul><ul><li>Mixed Mode </li></ul><ul><li>Multi Parameter </li></ul><ul><li>Plug and Measure </li></ul><ul><li>Sensor wear </li></ul><ul><li>Time To Maintenance (TTM) </li></ul><ul><li>Adaptive Calibration Timer (ACT) </li></ul><ul><li>CIP/SIP counter </li></ul><ul><li>ISM Data </li></ul>Key features of the M700 are the integration of ISM ® and the unique dual channel mixed-mode input features
    • 44. Communication Capabilities HART and FOUNDATION Fieldbus Integration Open Architecture with PROFIBUS METTLER TOLEDO integrates your analytical measurement into your control system
    • 45. Agenda <ul><li>Introduction </li></ul><ul><li>Oxygen Measurement Key Drivers </li></ul><ul><li>Amperometric Measurement Solutions </li></ul><ul><li>System overview </li></ul><ul><ul><li>System Offering </li></ul></ul><ul><ul><li>Sensor </li></ul></ul><ul><ul><li>Transmitter </li></ul></ul><ul><ul><li>Housing </li></ul></ul><ul><li>Applications & Success stories </li></ul><ul><li>Summary and outlook </li></ul>
    • 46. Housing Overview for Oxygen Systems Q1 10 <ul><li>Simple and durable </li></ul><ul><li>Ideal for batch processes </li></ul>InFit 761e <ul><li>For automated sensor retraction and air flushing </li></ul><ul><li>Automatic process retraction </li></ul><ul><li>Remove sensor without interruption of the process </li></ul>AirCheck™ InTrac 777e INGOLD offers a wide range of application solutions, customizable for all process adaptions
    • 47. The TRI-LOCK TM System <ul><li>Improved operational safety (TRI-LOCK TM ) </li></ul><ul><li>I mproved reliability </li></ul><ul><li>Minimized risk of failures </li></ul>Patented immersion tube 100 mm & 200 mm Sensor detector Positive position rod for InTrac 7X7 & 7x9 (enclosed) Maintenance and sensor replacement without process interruption
    • 48. 1) Patented Immersion Tube <ul><li>Complete separation of process media and flushing chamber thanks to </li></ul><ul><li>the patented immersion tube including two inlaying o-rings. </li></ul>Increased operational safety and reliable operation due to the safety TRI-LOCK system.
    • 49. 2) Sensor Detection <ul><li>If no sensor is mounted in the housing, it is impossible to insert the </li></ul><ul><li>housing into measurement position. </li></ul>Increased operational safety and reliable operation due to the safety TRI-LOCK system.
    • 50. 3) Positive Position Rod <ul><li>The positive position rod ensures, that the sensor is always in the same </li></ul><ul><li>position. In measurement and service position. </li></ul>Increased operational safety and reliable operation due to the safety TRI-LOCK system.
    • 51. Agenda <ul><li>Introduction </li></ul><ul><li>Oxygen Measurement Key Drivers </li></ul><ul><li>Amperometric Measurement Solutions </li></ul><ul><li>System overview </li></ul><ul><li>Applications & Success stories </li></ul><ul><li>Summary and outlook </li></ul>
    • 52. Applications N2 blanketing Inertization Off-gas Monitoring & Vapor recovery <ul><li>Nitrogen atmosphere only </li></ul><ul><li>Nitrogen and solvents </li></ul><ul><li>Gas mixtures </li></ul>Background gas: Background gases: Background gases:
    • 53. Add customer-specific slides from Application Presentation Portfolio !
    • 54. Agenda <ul><li>Introduction </li></ul><ul><li>Oxygen Measurement Key Drivers </li></ul><ul><li>Opto-chemical Measurement Solutions </li></ul><ul><li>System overview </li></ul><ul><li>Applications & Success stories </li></ul><ul><li>Summary and outlook </li></ul>
    • 55. Summary and Outlook <ul><li>In-Line measurement gives you a leading-edge in process control and reliability, also for gas measurement like Oxygen </li></ul><ul><li>Amperometric Oxygen systems are accurate, easy to maintain and to calibrate, and at a fraction of the costs of other analyzers </li></ul><ul><li>METTLER TOLEDO can help you improve your process today! </li></ul><ul><ul><li>Through its extensive know-how of process applications </li></ul></ul><ul><ul><li>With our broad analytical coverage of measurement parameters </li></ul></ul><ul><li>In 2010, METTLER TOLEDO will also offer new optical oxygen solutions for top performance and minimum maintenance </li></ul>METTLER TOLEDO – an unique choice of measurement solutions for gas and liquid analytics

    ×