Your SlideShare is downloading. ×
Va tech elin
Upcoming SlideShare
Loading in...5
×

Thanks for flagging this SlideShare!

Oops! An error has occurred.

×
Saving this for later? Get the SlideShare app to save on your phone or tablet. Read anywhere, anytime – even offline.
Text the download link to your phone
Standard text messaging rates apply
0 Comments
0 Likes
Statistics
Notes
  • Be the first to comment

  • Be the first to like this

No Downloads
Views
Total Views
755
On Slideshare
0
From Embeds
0
Number of Embeds
0
Actions
Shares
0
Downloads
0
Comments
0
Likes
0
Embeds 0
No embeds

Report content
Flagged as inappropriate Flag as inappropriate
Flag as inappropriate

Select your reason for flagging this presentation as inappropriate.

Cancel
No notes for slide

Transcript

  • 1. VA TECH ELIN EBG Elektronik>pDRIVE< MX Frequency InverterThe Power Drives Company E l e k t r o n i k
  • 2. Everything in View – Everything under Control. >pDRIVE< standard functions for optimum power in the shortest time I Flexible display configuration The large graphic display screen and the distinctive pictographs on the keypad simplify the process of optimal parameterisation and can be quickly adapted to the individual needs of the user. The status of the equipment, the reference values and actual values – everything has its place. I Intelligent application macros In order to guarantee the shortest startup times possible, our >pDRIVE< MX inverters are equipped with sophisticated parameter pre-settings for all standard applications. However, expert users value the possibility of saving their own settings in user macros. I Multifunctional motor protection >pDRIVE< MX frequency inverters immediately recognize overloaded and underloaded motors and react according to the respective requirements. Moreover, >pDRIVE< features integrated heating to protect the motor from condensation. >pDRIVE< functions for individual applications Reliable crane control When the crane function is activated, parameters are automatically set to the respective hoisting and trolley functions. These parameters can be more precisely adjusted to meet the needs of a particular application. The rotational speed is automatically adjusted for lower loads (fast mode). Controlled failure behaviour Upon request, >pDRIVE< inverters can make attempts at minimizing damage in the event of system failures. The inverter reacts to various types of failures, such as external or process failures, with an alarm, switching off or with sending a digital signal to a PLC. >pDRIVE< takes no risk! Protective emergency operation The safety of the personnel is always more important than the protection of the inverter. In emergency situations the >pDRIVE< MX deactivates several inverter protection functions in order to provide adequate personal protection. Automatic balance control If several inverters operate on the same load, a load balance process is essential because unavoidable inaccuracies can arise even with speed-controlled devices. The >pDRIVE< balance control either produces an internal correction signal or processes the reference value of an external control unit. Economical braking method >pDRIVE< frequency inverters are equipped with an internal “motor braking function” that provides braking power without additional braking equipment. Alternatively, more stringent demands may require an external braking unit that is reliably controlled and monitored by the >pDRIVE< MX.The Power Drives Company >pDRIVE< 3
  • 3. Simply Intelligent – the new MatriX 2.0 I Local control Everything at a glance. The device status of >pDRIVE< MX, all actual and reference values as well as the status of the digital input signals are available for monitoring purposes or for online control. Computer-controlled systems have become the norm in the industry. We have expanded on this basic requirement to include application-specific requirements of our customers and have developed an unusually convenient and powerful software program called MatriX 2.0. The program guarantees smooth and reliable communication between the >pDRIVE< MX frequency inverter and the control I Actual-value recorder computer. The Windows platform is used to modify and transmit parameters, thus significantly The right instrument for startups. The user can select reducing startup times. either the analogue or digital status in real-time mode during operation and record the data for later analysis. The built-in trigger is valuable particularly for the analysis of unplanned events. I Parameter-Editor Our concise user interface is available on personal computers. All parameters can be queried and changed online if necessary. The most significant values are also displayed so the user has all the required information. I Docu mode The input parameters and actual values are compactly and concisely presented, stored or printed as requested. Parameters that differ from default settings are specially marked. The decisive advantage of this function is that the user can define the settings for one inverter and can transfer these settings auto- matically to all the other inverters at the plant. I Failure memory Intelligent support is also available in the event of failures: >pDRIVE< MX inverters make a detailed data record of each problem. The failure memory can easily be evaluated and archived with the help of MatriX 2.0.The Power Drives Company >pDRIVE< 5
  • 4. Always up to date at www.pdrive.com. Trouble-free Communication. On our newly designed homepage you will find important information more quickly than ever Remote maintenance through complex bus systems requires discipline in design, development before. No matter what you are looking for and thanks to the new convenient menu, only one or and implementation. Our fully developed optional bus modules meet these stringent demands. two clicks on the mouse will lead you to the information you seek. You make the choice. Call up >pDRIVE< MX can be quickly integrated into various bus systems such as Interbus, Profibus DP, worldwide contact addresses and services at www.pdrive.com. Current and older software versions DeviceNet or CANopen either in existing or new configurations. Current system values can easily are available for download free of charge at our website. be controlled, parameters set and values analysed in the control room.The Power Drives Company >pDRIVE< 7
  • 5. >pDRIVE< MX basic – Unbeatably Simple. >pDRIVE< Output current (400 V) Power MX basic 15 / 18 32 / 38 A 15 / 18,5 kW MX basic 18 / 22 38 / 46 A 18,5 / 22 kW MX basic 22 / 30 49 / 59 A 22 / 30 kW MX basic 30 / 37 61 / 73 A 30 / 37 kW MX basic 37 / 45 75 / 90 A 37 / 45 kW MX basic 45 / 55 88 / 106 A 45 / 55 kW MX basic 55 / 75 117 / 140 A 55 / 75 kW MX basic 75 / 90 142 / 170 A 75 / 90 kW MX basic 90 / 110 172 / 206 A 90 / 110 kW MX basic 110 / 132 208 / 250 A 110 / 132 kW MX basic 132 / 160 250 / 300 A 132 / 160 kW MX basic 160 / 200 325 / 390 A 160 / 200 kW MX basic 200 / 250 404 / 485 A 200 / 250 kW MX basic 250 / 315 475 / 570 A 250 / 315 kW MX basic 315 / 380 583 / 700 A 315 / 380 kW MX basic 315 / 400 617 / 740 A 315 / 400 kW Modern frequency inverters must be as varied MX basic 400 / 500 767 / 920 A 400 / 500 kW as the wishes of the user. Standard applications MX basic 500 / 630 904 / 1085 A 500 / 630 kW require simple startup within the shortest time possible. Simplified and more reliable monitoring General Data is also necessary. The >pDRIVE< MX basic Mains voltage 3-phase 400 V -15 % +15 %; 50 / 60 Hz series offers these advantages by means of a Maximum current 150 % for high overload / 120 % for high continuous load (min. 60 s / 10 min) sophisticated short menu to match your drive. Control process AVC (auto vector control) The result is that you can quickly and reliably Design Built-in unit with protection degree IP20 / IP00 set the necessary parameters. Interface Matrix keypad, extensible terminal strip, RS 232, Profibus DP, Interbus, CANopen, DeviceNet The high-precision measurement of the motor Specific Automatic motor load limitation without switch off, residual voltage forms the basis for a flying start functions underload recognition, motor heating, catch-on-the-fly function, within a few milliseconds, irrespective of the emergency operation for fan applications, PID controller, motor brake without braking unit rotational direction. This method foregoes time- consuming searches. >pDRIVE< MX basic is the ideal drive for your pumps, fans, compressors, conveyor belts, stirrers and much more. Innovative and proven a thousandfold and available ex warehouse.The Power Drives Company >pDRIVE< 9
  • 6. >pDRIVE< MX plus – Incredible Flexibility. The continuous development of target-group solutions is the deciding factor for the distinctive capabilities of the >pDRIVE< MX plus series. Even the greatest demands are fulfilled. With features such as pure dynamics, adapted func- tion modules and multi-functional options, the applications of this inverter have very few limitations. The numerous integrated special functions of MX plus offer optimum benefits to the user. In addition to the specific drive assign- ments, the inverter takes on a number of supplementary functions for plant control. A separately adjustable software function block with an integrated brake control makes >pDRIVE< Output current (400 V) Power it possible to precisely and reliably lift and lower MX plus 04 10 / 11 A 4 kW loads that weigh tons. MX plus 05 12 / 13 A 5,5 kW MX plus 07 16 / 18 A 7,5 kW MX plus 11 22 / 24 A 11 kW MX plus 15 / 18 32 / 38 A 15 / 18,5 kW MX plus 18 / 22 38 / 46 A 18,5 / 22 kW MX plus 22 / 30 49 / 59 A 22 / 30 kW MX plus 30 / 37 61 / 73 A 30 / 37 kW MX plus 37 / 45 75 / 90 A 37 / 45 kW MX plus 45 / 55 88 / 106 A 45 / 55 kW MX plus 55 / 75 117 / 140 A 55 / 75 kW MX plus 75 / 90 142 / 170 A 75 / 90 kW MX plus 90 / 110 172 / 206 A 90 / 110 kW MX plus 110 / 132 208 / 250 A 110 / 132 kW MX plus 132 / 160 250 / 300 A 132 / 160 kW MX plus 160 / 200 325 / 390 A 160 / 200 kW MX plus 200 / 250 404 / 485 A 200 / 250 kW MX plus 250 / 315 475 / 570 A 250 / 315 kW MX plus 315 / 380 583 / 700 A 315 / 380 kW MX plus 315 / 400 617 / 740 A 315 / 400 kW MX plus 400 / 500 767 / 920 A 400 / 500 kW MX plus 500 / 630 904 / 1085 A 500 / 630 kW General Data Mains voltage 3-phase 400…500 V -15 % +10 %; 50 / 60 Hz Maximum current 150 % for high overload / 120 % for high continuous load (min. 60 s / 10 min) Control process AVC (auto-vector-control) with and without encoder feedback Design Built-in unit with protection degree IP20 / IP00 Interface Matrix keypad, extensible terminal strip, RS 232, Profibus DP, Interbus, CANopen, DeviceNet Specific Application specific parameter settings (macros), functions load balance, crane control, load-dependent fast modeThe Power Drives Company >pDRIVE< 11
  • 7. >pDRIVE< MX multi – Unequalled Individuality. >pDRIVE< Output current (400 V) Power MX multi 15 / 18 32 / 38 A 15 / 18,5 kW MX multi 18 / 22 38 / 46 A 18,5 / 22 kW MX multi 22 / 30 49 / 59 A 22 / 30 kW MX multi 30 / 37 61 / 73 A 30 / 37 kW MX multi 37 / 45 75 / 90 A 37 / 45 kW MX multi 45 / 55 88 / 106 A 45 / 55 kW MX multi 55 / 75 117 / 140 A 55 / 75 kW MX multi 75 / 90 142 / 170 A 75 / 90 kW MX multi 90 / 110 172 / 206 A 90 / 110 kW MX multi 110 / 132 208 / 250 A 110 / 132 kW MX multi 132 / 160 250 / 300 A 132 / 160 kW MX multi 160 / 200 325 / 390 A 160 / 200 kW MX multi 200 / 250 404 / 485 A 200 / 250 kW MX multi 250 / 315 475 / 570 A 250 / 315 kW As long as individual requests can be fulfilled, Problems with applications in heavily polluted MX multi 315 / 380 583 / 700 A 315 / 380 kW the ideal situation for the customer, of course, locations are no longer an issue with the MX multi 315 / 400 617 / 740 A 315 / 400 kW is ex works. Components for power supply, >pDRIVE< MX multi cubicle unit. To remedy MX multi 400 / 500 767 / 920 A 400 / 500 kW control and operation are included in the such cases we have provided another design MX multi 500 / 630 904 / 1085 A 500 / 630 kW >pDRIVE< MX multi inverters. To guarantee that features protection degree IP54 in addition utmost efficiency and reliability it is also practical to the standard design with protection degree General Data to additionally install a main switch, output motor IP23. Inverter series MX multi-basic: 3-phase 400 V -15 % +15 %; 50 / 60 Hz filter or a complete line contactor control and MX multi-plus: 3-phase 400...500 V -15 % +10 %; 50 / 60 Hz deliver ex works. Design Compact unit with protection degree IP54 (up to 75 / 90) Cubicle unit with protection degree IP23 or IP54 Cubicle design System Rittal TS8 or Sarel S6000 in RAL 7032 structure Dimensions IP23: height 2060 mm, width 500 or 600 mm IP54: height 2260 mm, width 500 or 600 mm Interface Matrix keypad, extensible terminal strip, RS 232, Profibus DP, Interbus, CANopen, DeviceNet Possible options Cubicle heating, main switch, motor distributing pole for auxiliaryThe Power Drives Company drives, output motor filter, operation in the cubicle door, basement, >pDRIVE< special lacquering, cubicle lighting, power socket 13
  • 8. >pDRIVE< MX top – Reliable Size. Complex high-tech solutions designed for 690 V mains appear to exceed all possible limitations in multiple applications. The electronic design of >pDRIVE< MX is ideally suitable for capacities of up to 1.5 MW. The control parameters are optimised by setting the motor rating plate data and auto-tuning during standstill. Special I A variable load balancing control prevents functions tuned to the various applications imbalances in parallel motors with combined increase the customer benefits as well as the loads. operational safety: I Where required, the entire drive is connected I The automatic motor load limitation protects by means of the automatic line contactor the motor and prevents troublesome fault control to the mains via the control terminal disconnections in pump and fan drives. strip or the field bus. Options such as 12-pulse rectification, insulation monitoring, Pt100 motor monitoring and many more are possible with these devices. >pDRIVE< Output current (690 V) Power MX top 160 / 200 190 / 230 A 160 / 200 kW MX top 200 / 250 230 / 275 A 200 / 250 kW MX top 250 / 315 285 / 340 A 250 / 315 kW MX top 315 / 400 350 / 420 A 350 / 400 kW MX top 400 / 500 435 / 520 A 400 / 500 kW MX top 500 / 630 550 / 660 A 500 / 630 kW MX top 630 / 800 700 / 840 A 630 / 800 kW MX top 800 / 1000 875 / 1050 A 800 / 1000 kW MX top 1000 / 1200 1050 / 1260 A 1000 / 1200 kW MX top 1200 / 1500 1320 / 1580 A 1200 / 1500 kW General Data Mains voltage 3-phase 690 V ±10 %; 50 / 60 Hz Maximum current 150 % for high overload / 120 % for high continuous load (min. 60 s / 10 min) Control process AVC (auto vector control) with and without encoder feedback Design Cubicle unit with protection degree IP23 Interface Matrix keypad, extensible terminal strip, RS 232, Profibus DP, Interbus, CANopen, DeviceNet Specific Line contactor control, emergency operation, motor heating, functions catch-on-the-fly function, automatic motor load limitation, motor brake without braking unitThe Power Drives Company >pDRIVE< 15
  • 9. >pDRIVE< MX hydro – Water-cooled. Foto: Herrenknecht >pDRIVE< Output current (400 V) Power MX plus-hydro 90 / 110 172 / 206 A 90 / 110 kW MX plus-hydro 110 / 132 208 / 250 A 110 / 132 kW MX plus-hydro 132 / 160 250 / 300 A 132 / 160 kW MX plus-hydro 160 / 200 325 / 390 A 160 / 200 kW MX plus-hydro 200 / 250 404 / 485 A 200 / 250 kW MX plus-hydro 250 / 315 475 / 570 A 250 / 315 kW MX plus-hydro 315 / 400 617 / 740 A 315 / 400 kW MX plus-hydro 400 / 500 767 / 920 A 400 / 500 kW MX plus-hydro 500 / 630 904 / 1085 A 500 / 630 kW Output current (690 V) Power MX top-hydro 160 / 200 190 / 230 A 160 / 200 kW MX top-hydro 200 / 250 230 / 275 A 200 / 250 kW MX top-hydro 250 / 315 285 / 340 A 250 / 315 kW MX top-hydro 315 / 400 350 / 420 A 350 / 400 kW MX top-hydro 400 / 500 435 / 520 A 400 / 500 kW MX top-hydro 500 / 630 550 / 660 A 500 / 630 kW MX top-hydro 630 / 800 700 / 840 A 630 / 800 kW MX top-hydro 800 / 1000 875 / 1050 A 800 / 1000 kW MX top-hydro 1000 / 1200 1050 / 1260 A 1000 / 1200 kW MX top-hydro 1200 / 1500 1320 / 1580 A 1200 / 1500 kW General Data The devices in the >pDRIVE< MX plus and This guarantees constant cooling quality without Mains voltage plus-hydro: 3-phase 400…500 V -15 % +10 %; 50 / 60 Hz >pDRIVE< MX top series are also available in the dangers of algae, rust and limestone. Re- top-hydro: 3-phase 690 V ±10 %; 50 / 60 Hz water-cooled design for the elimination of power cooling by means of a water-water-heat Maximum current 150 % for high overload / 120 % for high continuous load (min. 60 s / 10 min) loss across long ranges. We have purposely exchanger can also be integrated into the cubicle Protection degree IP00, IP23, IP54 selected a system with a closed secondary configuration if necessary. Interface Matrix keypad, extensible terminal strips, RS 232, circuit in order to guarantee maximum availability Profibus DP, Interbus, CANopen, DeviceNet even in the roughest ambient conditions. Possible options Water-water-heat exchanger, output motor filterThe Power Drives Company >pDRIVE< 17
  • 10. >pDRIVE< LX plus – Sinusoidal Energy Regeneration. >pDRIVE< Nominal current (400 V) Power LX plus 26 37 A 26 kVA LX plus 42 60 A 42 kVA LX plus 60 89 A 60 kVA LX plus 100 144 A 100 kVA LX plus 175 251 A 175 kVA LX plus 340 488 A 340 kVA LX plus 675 975 A 675 kVA General Data Mains voltage 3-phase 400…470 (500) V -40 % +15 %; 50 / 60 Hz Maximum current 120 % for min. 60 s / 10 min Design Built-in unit with protection degree IP00, line filter module and line choke Interface Matrix keypad, extensible terminal strip, RS 232, Profibus DP Specific Sinusoidal mains current, 2-staged line filter, user macros, functions adjustable cos ␸, reactive current compensation The regeneration capability ensures the shortest amortization times in drives that operate fre- quently in generatoric operation, such as test stands, unreeling systems, hoisting devices, etc. The >pDRIVE< LX can be used in connection with a single drive as well as a supply / regener- ative unit for a group drive. The increasing demand for controlled drives has led to enormous burdens on industrial mains. With the >pDRIVE< LX plus we have made a significant contribution to correcting this situation. The sinusoidal mains current in the device ensures complete avoidance of the low- frequency current harmonics. Moreover, the available reserve of the device can be used for reactive current compensation in the supplied mains.The Power Drives Company >pDRIVE< 19
  • 11. The Power Drives Company www.pdrive.com 8 074 051.01 HFHA – The right to make technical changes is reserved - Concept and design VA TECH ELIN EBG Elektronik GmbH & Co Ruthnergasse 1 A-1210 Vienna, Austria Phone: (+43/1) 29191-0 Fax: (+43/1) 29191-15 www.pdrive.com E l e k t r o n i k

×