Hy Chill Presentation Hmsb

  1. 1. www.hychill.com.au Your Performance and Energy Savings Solution
  2. 3. Overview <ul><li>Today, we’d like to: </li></ul><ul><ul><li>Introduce HyChill Hydrocarbon refrigerant products </li></ul></ul><ul><li>An d an Exciting Agenda... </li></ul><ul><ul><li>To share ideas on the increased performance for your air-conditioning systems, with the bonus of energy savings </li></ul></ul>
  3. 4. Who are we? <ul><li>HyChill </li></ul><ul><ul><li>Leading specialists in the hydrocarbon industry since early 1990s </li></ul></ul><ul><ul><li>Premium & Quality products: Superior refrigerant, state-of-the-art specialised production system, superior purity </li></ul></ul>
  4. 5. Existing FC refrigerants <ul><li>Existing refrigerant gases </li></ul><ul><ul><li>First generation: CFC’s (e.g. R12) and HCFC’s (e.g. R22) </li></ul></ul><ul><ul><ul><li>After many years, the world became aware that these refrigerants were severe Ozone Depleting and Global Warming gases. </li></ul></ul></ul><ul><ul><ul><li>Bans on import and manufacture of these gases are being put in place through the “Montreal Protocol” </li></ul></ul></ul><ul><ul><ul><li>Must be recovered and destroyed  costly </li></ul></ul></ul>
  5. 6. Existing FC refrigerants <ul><li>Existing refrigerant gases (cntd) </li></ul><ul><ul><li>Second generation: HFC’s (e.g. R134a, R400 series) </li></ul></ul><ul><ul><ul><li>NOT a “drop in” replacement for First Generation CFC’s. </li></ul></ul></ul><ul><ul><ul><li>When retro-fitting to R12 systems: requires expensive changes, or complete new system </li></ul></ul></ul><ul><ul><ul><li>Usually lower performance, lower efficiency </li></ul></ul></ul><ul><ul><ul><li>R134a systems struggle in extreme heat conditions </li></ul></ul></ul><ul><ul><ul><li>Still a very potent Greenhouse Gas </li></ul></ul></ul><ul><ul><ul><li>Controls and restrictions on use already spreading </li></ul></ul></ul>
  6. 7. Newer options <ul><li>Some proposed newer alternatives </li></ul><ul><ul><li>R152a </li></ul></ul><ul><ul><ul><li>NOT a “drop in” replacement for First Generation CFC’s. </li></ul></ul></ul><ul><ul><ul><li>Patented. Not proven. No widespread use. </li></ul></ul></ul><ul><ul><ul><li>Still 47 times more potent global warming gas than HC. </li></ul></ul></ul><ul><ul><ul><li>Combustion produces toxic chemicals. </li></ul></ul></ul><ul><ul><li>CO 2 </li></ul></ul><ul><ul><ul><li>Operates at very high pressures (10 times greater than existing systems). </li></ul></ul></ul><ul><ul><ul><li>Requires completely new equipment - your investment in existing equipment is lost. </li></ul></ul></ul>
  7. 8. HyChill Premium refrigerants <ul><li>New Generation: HYDROCARBONS </li></ul><ul><ul><li>DROP-IN replacement for existing refrigerants </li></ul></ul><ul><ul><li>NO Ozone Depletion </li></ul></ul><ul><ul><li>Virtually NIL Global Warming </li></ul></ul><ul><ul><li>Non-corrosive </li></ul></ul><ul><ul><li>Higher performance </li></ul></ul><ul><ul><li>Greater efficiency </li></ul></ul><ul><ul><li>Longer compressor life </li></ul></ul><ul><ul><li>No production, use or import restrictions </li></ul></ul><ul><ul><li>Gas does NOT need to be recovered or destroyed </li></ul></ul>
  8. 9. HyChill HC refrigerants benefits <ul><li>Natural refrigerant. Not patented. Great for the environment. </li></ul><ul><li>Superior performance – average savings record approx 20% (typical range between 10% and 40%) </li></ul><ul><li>Can increase AC system life </li></ul><ul><ul><li>Lower operating pressures </li></ul></ul><ul><ul><li>Does not break down to form corrosive chemicals </li></ul></ul><ul><ul><li>Does not react with moisture to form corrosive chemicals </li></ul></ul>
  9. 10. What HyChill Minus 30 can do for your systems continued <ul><li>Compatible with existing refrigerant oils (including mineral, POE, PAG, PAO, etc.) </li></ul><ul><li>Minimal (if any) modifications required to existing AC system </li></ul><ul><ul><li>Some systems may require certain modifications, but energy savings cost reductions are typically much greater </li></ul></ul>
  10. 11. HyChill HC refrigerants benefits <ul><li>Safe to use </li></ul><ul><li>Great choice for the environment </li></ul><ul><ul><li>NO ozone depleting elements </li></ul></ul><ul><ul><li>Extremely low global warming potential </li></ul></ul><ul><ul><li>Natural refrigerants are encouraged by environment groups and many world governments </li></ul></ul><ul><li>No recovery or destruction required as with fluorocarbons. </li></ul>
  11. 12. Common myths and facts about refrigerants CONTINUED…
  12. 13. Myth #1 <ul><li>MYTH: </li></ul><ul><ul><li>First and second generation refrigerants (R12, R134a) are safe to use and service </li></ul></ul><ul><li>FACT: </li></ul><ul><ul><li>There are safety risks with ALL refrigeration systems </li></ul></ul><ul><ul><ul><li>Users and service technicians: Toxicity and Flammability </li></ul></ul></ul>
  13. 14. Myth #2 <ul><li>MYTH: </li></ul><ul><ul><li>Hydrocarbon refrigerants should not be used because they are flammable </li></ul></ul><ul><li>FACT: </li></ul><ul><ul><li>Hydrocarbons refrigerants actually present fewer risks to users and service technicians than second generation refrigerants (R134a) </li></ul></ul><ul><ul><ul><li>Well established systems and processes are in place to use hydrocarbons safely. They have been used in all kinds of applications for hundreds of years, and are one of the most well understood chemicals on earth. </li></ul></ul></ul><ul><ul><ul><li>Hydrocarbons do not break down to form the toxic chemicals such as Hydrofluoric Acid and Trifluoro-acetic acid (like R134a does) </li></ul></ul></ul><ul><ul><ul><li>System lubricants have always been flammable anyway. </li></ul></ul></ul>
  14. 15. Myth #3 <ul><li>MYTH: </li></ul><ul><ul><li>Hydrocarbon refrigerants should not be used because the AC/refrigeration system was not designed for hydrocarbons </li></ul></ul><ul><li>FACT: </li></ul><ul><ul><li>HyChill Hydrocarbon Refrigerants are DESIGNED FOR these existing systems. </li></ul></ul><ul><ul><ul><li>Just like you can buy an aftermarket sports steering wheel or sports seat, for your air-conditioner you can install our high-performance refrigerant instead of your ordinary refrigerant. </li></ul></ul></ul><ul><ul><ul><li>Our refrigerants can actually increase the life of your system </li></ul></ul></ul>
  15. 16. Myth #4 <ul><li>MYTH: </li></ul><ul><ul><li>Hydrocarbon refrigerants should not be used because they will damage the compressor or other components </li></ul></ul><ul><li>FACT: </li></ul><ul><ul><li>HyChill Hydrocarbon Refrigerants can actually INCREASE the life of your compressor and system components. Why? </li></ul></ul><ul><ul><ul><li>HyChill refrigerants are more chemically stable – they will not form corrosive compounds </li></ul></ul></ul><ul><ul><ul><li>HyChill refrigerants operate at lower “high-side” pressures, thereby reducing the load and wear on compressors </li></ul></ul></ul>
  16. 17. Improved efficiency and greater performance: Can it really be achieved? CONTINUED…
  17. 18. How efficiency and performance is achieved <ul><li>We use our new generation HyChill refrigerants, state of the art technology and skilled technicians to yield significant energy efficiency and performance gains in your existing AC and refrigeration systems – from small split systems right through to large chillers </li></ul>
  18. 19. How it works <ul><li>Based on over 100 years of science </li></ul><ul><ul><li>Conducts heat 50% more efficiently than R134a </li></ul></ul><ul><ul><li>than rejects heat 50% faster than R134a </li></ul></ul><ul><ul><li>Chemically stable: does not break down when exposed to heat or moisture </li></ul></ul>R22= CCl 2 F 2 F Cl Minus50 = CH 3 CH 3 + CH 3 CH 2 CH 3 F Cl C H C C H H H C H H H H C H H H C H H H
  19. 20. Physical property data All Types b Mineral Lubricant Miscibility 359.1 160.8 Refrigerant Efficiency (J/g) 4 -42 -41 Boiling Point ( °C ) 3 >130 96.2 Critical Temperature ( °C ) 2 41.1 86.5 Molecular Mass CH 3 CH 3 + CH 3 CH 2 CH 3 CH Cl F 2 Molecular Formula HC HCFC Class Classification Minus 50 R22 Characteristic/ Refrigerant /Commercial
  20. 21. Supporting Products <ul><li>MINUS 10 – Premium refrigerant for domestic refrigerators </li></ul><ul><li>MINUS 30 – Premium refrigerant for fixed air conditioning of all sizes </li></ul><ul><li>MINUS 40 – Premium refrigerant for domestic & commercial air conditioners </li></ul><ul><li>SRO 500 – Synthetic Refrigerant oil </li></ul><ul><li>EcoFlush – Universal Flushing Agent </li></ul><ul><li>More products in development </li></ul>
  21. 22. Our priority: quality, performance and professional service <ul><li>Typical process </li></ul><ul><ul><li>Assess your installations </li></ul></ul><ul><ul><li>Brief you on how we can help </li></ul></ul><ul><ul><li>Information transfer, demonstrations if necessary </li></ul></ul><ul><ul><li>Contract </li></ul></ul><ul><ul><li>Proceed with works </li></ul></ul><ul><ul><ul><li>Includes before + after monitoring </li></ul></ul></ul><ul><ul><ul><li>Includes staff training </li></ul></ul></ul><ul><ul><li>Detailed report on before/after performance </li></ul></ul><ul><ul><li>After-sales service/support </li></ul></ul>
  22. 23. Our priority: quality, performance and professional service <ul><li>Important points </li></ul><ul><ul><li>Minimal disruption to your operations </li></ul></ul><ul><ul><li>Full training to your technicians and after-sales service </li></ul></ul><ul><li>Assurance </li></ul><ul><ul><li>AUD$5 Million product liability insurance </li></ul></ul><ul><ul><li>Peace of mind – our product is fully warranted. Your equipment is protected. </li></ul></ul>
  23. 24. Track Record Since 1992, more than 40 million refrigerators and 4 million cars worldwide now use hydrocarbons. These “Greenfreeze” refrigerators have majority market share in Europe. Use in cars grew over 30% in Australia last year.
  24. 25. Track record <ul><li>SINGAPORE </li></ul><ul><ul><li>Robertson Quay Hotel using 70 tr York recip chillers recorded 15% savings </li></ul></ul><ul><ul><li>Holland Village Shopping Centre using 20 tr York recip chillers recorded 17% savings </li></ul></ul><ul><ul><li>Singapore National Printers using 10 tr Carrier pck units recorded 13% savings </li></ul></ul><ul><li>THAILAND </li></ul><ul><ul><li>Carrier HQ Building using 150 tr Carrier recip chiller recorded 14% savings </li></ul></ul><ul><ul><li>Two 7-11 stores using split unit, walk-in freezer recorded 20% savings </li></ul></ul>
  25. 26. Track record <ul><li>INDONESIA </li></ul><ul><ul><li>ITC Mangga Dua using 208 tr carrier recip chillers recorded 34.8% savings </li></ul></ul><ul><ul><li>JW Marriott using 132 tr York receip chillers recorded 25% savings </li></ul></ul><ul><ul><li>Super-mall Karawaci using 60 tr Hitachi screw AHU recorded 30% savings </li></ul></ul><ul><ul><li>Mulia hotel cold room using Copematic 5 tr semi-hermetic comp recorded 13.3% savings </li></ul></ul><ul><ul><li>Sol Marabella hotel using 1.5tr Sanyo split unit recorded 24.4% savings </li></ul></ul><ul><ul><li>Maspion Plaza 150 tr York receip chillers recorded 22% savings </li></ul></ul>
  26. 27. Track record <ul><li>BALI </li></ul><ul><ul><li>MAYA UBUD RESORT & SPA recorded 41% savings </li></ul></ul><ul><ul><li>SAHID JAYA HOTEL recorded 51% savings </li></ul></ul><ul><ul><li>RITZ CALTON HOTEL recorded 28% savings </li></ul></ul><ul><ul><li>KARTIKA PLAZA BEACH HOTEL recorded 55% savings </li></ul></ul>
  27. 28. Track record <ul><li>LOMBOK </li></ul><ul><ul><li>SAHID JAYA HOTEL recorded 72% savings </li></ul></ul><ul><ul><li>OBEROI HOTEL recorded 18% savings </li></ul></ul><ul><ul><li>NOVOTEL HOTEL recorded 39% savings </li></ul></ul><ul><ul><li>LOMBOK RAYA HOTEL recorded 27% savings </li></ul></ul><ul><ul><li>SHERATON SENGGIGI HOTEL recorded 53% savings </li></ul></ul><ul><ul><li>SENGGIGI BEACH HOTEL recorded 25% savings </li></ul></ul><ul><ul><li>INTAN LOMBOK recorded 21% savings </li></ul></ul><ul><ul><li>HOLIDAY INN HOTEL recorded 20% savings </li></ul></ul>
  28. 29. Track record <ul><li>MALAYSIA </li></ul><ul><ul><li>OYL R&D lab where new 3 tr split unit recorded 27% savings </li></ul></ul><ul><ul><li>UiTM using 80 tr Hitachi screw chiller recorded 19.7% savings </li></ul></ul><ul><ul><li>Damansara realty using 10 tr carrier pck units recorded 32% savings </li></ul></ul><ul><ul><li>Pantai hospital Bangsar using 80 tr York recip chillers recorded 24% savings </li></ul></ul><ul><ul><li>Lam Wah Ee hospital Penang using pck units recorded 20% savings </li></ul></ul><ul><ul><li>Venture mfg JB using 65 tr Dunham bush recip chillers recorded 47% savings </li></ul></ul><ul><ul><li>Sumitomo JB using 32 tr York recip chillers recorded 21% savings </li></ul></ul><ul><ul><li>Li tat mfg JB using 17 tr York pckg unit recorded 29% savings </li></ul></ul><ul><ul><li>Classic Emas Extrusion Factory Sarawak 33% savings </li></ul></ul>
  29. 30. Your opportunity <ul><li>Your choice: </li></ul><ul><ul><li>Treat your current costs as fixed overheads OR </li></ul></ul><ul><ul><li>Do your part for the environment </li></ul></ul><ul><ul><li> AND “Save $$ on your energy bills” </li></ul></ul>