Your SlideShare is downloading. ×
Osram endura
Osram endura
Osram endura
Osram endura
Upcoming SlideShare
Loading in...5
×

Thanks for flagging this SlideShare!

Oops! An error has occurred.

×
Saving this for later? Get the SlideShare app to save on your phone or tablet. Read anywhere, anytime – even offline.
Text the download link to your phone
Standard text messaging rates apply

Osram endura

1,161

Published on

www.xinghenglong.com

www.xinghenglong.com

0 Comments
0 Likes
Statistics
Notes
  • Be the first to comment

  • Be the first to like this

No Downloads
Views
Total Views
1,161
On Slideshare
0
From Embeds
0
Number of Embeds
0
Actions
Shares
0
Downloads
9
Comments
0
Likes
0
Embeds 0
No embeds

Report content
Flagged as inappropriate Flag as inappropriate
Flag as inappropriate

Select your reason for flagging this presentation as inappropriate.

Cancel
No notes for slide

Transcript

  • 1. The high-performance electrodeless fluorescent lamp OSRAM ENDURA®
  • 2. OSRAM ENDURA® – the high-performance electrodeless lighting system with a 60,000 hour life • Extremely long lamp life Unique operating principle of 60,000 hours for unique avantages • High luminous flux In contrast to conventional • Instant flicker-free start fluorescent lamps, the dis- • High luminous efficacy: charge needed to generate > 80 lm/W light in the OSRAM ENDURA® • Excellent quality of light: lamp does not take place colour rendering Ra > 80 between two electrodes but • High luminous flux over a without electrodes in a closed wide range of temperatures “ring” with no starting point thanks to amalgam and no end point. The energy technology is “injected” via ferrite rings • Low operating frequency: from outside using magnetic 250 kHz fields (induction principle). • Ideal for low-profile The lamp therefore has no luminaires parts that can wear out and • Low loss of luminous flux lasts so long that it may • Reliable ignition at never need changing. temperatures down to – 40 ºC, depending on ECG • DC operation Ferrite Magnetic field Phosphor UV radiation possible • Lamp and ECG may be separated up to 20 m, depen- ding on ECG Coil Electron Mercury atom Light Principle of OSRAM ENDURA® Phospor Light UV radiation Electrode Electron Mercuryatom Principle of a conventional fluorescent lamp Light on schedule. With their extremely long life and high luminous efficacy, ENDURA® lamps provide reliable and comfortable lighting in the under- ground station at Madrid airport.
  • 3. Extremely long life and Reliable long-life light high luminous efficacy with impressive comfort OSRAM ENDURA® has an Because it uses electronic extremely long life of 60,000 control gear, the ENDURA® hours. This is four to five times enjoys the benefits normally the normal service life of a associated with conventional fluorescent lamp. QUICKTRONIC®/LUMILUX® fluorescent lamps, such as The ENDURA® system instant flicker-free starting comprises an electrodeless and pleasant flicker-free light. fluorescent lamp and elec- tronic control gear, achieving Its extremely long life makes luminous flux values that no it perfect for all applications Guarantee Level 2 fluorescent lamp has ever in which relamping can only OSRAM System Guarantee achieved before. be done at enormous cost or The luminous efficacy of the where safety is of paramount There is a 5-year guarantee on ENDURA® is comparable to importance. The low overall the complete ENDURA® system that of fluorescent lamps. height of the OSRAM ENDURA® (QUICKTRONIC® ENDURA electronic means it can be used in control gear and ENDURA® lamp). low-profile luminaires. For the System Guarantee, the lighting system must be registered with OSRAM on the internet at www.osram.com/system-guarantee. Here you will also find further information and conditions relating to Guarantee Level 2. Ideal for tunnel lighting. Safe driving from start to finish with bright flicker-free light and extremely long relamping intervals.
  • 4. Technical data Dimensions in mm h a l h l b b 1 l 2 z Printed on paper treated with chlorine-free bleach. ENDURA® Type Product No. Rated Colour Colour rendering Luminous Length Width Height Fig. (EAN) Wattage index (CRI) flux l b h no. ENDURA 70 W/830 4050300817293 72 W LUMILUX Warm White Ra ≥ 80 6500 lm 315 mm 139 mm 75 mm 1 ENDURA 70 W/840 4050300817286 72 W LUMILUX Cool White Ra ≥ 80 6500 lm 315 mm 139 mm 75 mm 1 ENDURA 100 W/830 4050300668420 100 W LUMILUX Warm White Ra ≥ 80 8000 lm 315 mm 139 mm 75 mm 1 ENDURA 100 W/840 4050300668437 100 W LUMILUX Cool White Ra ≥ 80 8000 lm 315 mm 139 mm 75 mm 1 ENDURA 150 W/830 4050300668444 150 W LUMILUX Warm White Ra ≥ 80 12000 lm 415 mm 139 mm 75 mm 1 ENDURA 150 W/840 4050300668451 150 W LUMILUX Cool White Ra ≥ 80 12000 lm 415 mm 139 mm 75 mm 1 QUICKTRONIC® for OSRAM ENDURA® Type Product No. Lamp Permissible Mains Mains Power System Luminous Subject to change without notice. Errors and omissions excepted. (EAN) voltage frequency current at factor wattage flux fluctuations 230/240 V λ QT ENDURA 70-100/120-240 S 4050300804668 70 W 108 V to 264 V approx. 250 kHz 0,34 A > 0,9c 81 W 6500 lm 100 W 108 V to 264 V approx. 250 kHz 0,46 A > 0,9c 104 W 8000 lm QT ENDURA 100-150/120-240 S 4050300662589 100 W 108 V to 264 V approx. 250 kHz 0,62 A > 0,9c 146 W 11000 lm 150 W 108 V to 264 V approx. 250 kHz 0,69 A > 0,9c 153 W 12000 lm Type Temperature Lenght Width Height Distance Max. distance Weight Fig. no. range l b h between between holes a Lamp/ECG QT ENDURA 70-100/120-240 S – 20°C to + 50°C 181 mm 100 mm 43 mm 170 mm in preparation 70 W 950 g 2 QT ENDURA 70-100/120-240 S – 40°C to + 50°C 181 mm 100 mm 43 mm 170 mm in preparation 100 W 950 g 2 QT ENDURA 100-150/120-240 S – 40°C to + 50°C 181 mm 100 mm 43 mm 170 mm 20 m (100 W) 1140 g 2 QT ENDURA 100-150/120-240 S – 40°C to + 50°C 181 mm 100 mm 43 mm 170 mm 20 m (150 W) 1140 g 2 Amalgam technology makes a high luminous flux over a wide range The lifetime of the OSRAM ENDURA® system is determined of temperatures possible: > 90 % at amalgam temperatures from 55°C to 125°C primarily by the ECG lifetime, which is 60,000 hours with a failure rate of 10% when operated at the maximum temperature permitted at the measuring point on the ECG 110 housing. If the temperature is under the maximum permitted, 102 W003 GB 07/05 Co OSRAM CS CC 105 the lifetime increases. Relative luminous flux (%) 100 95 90 85 ENDURA® 80 (with amalgam) 75 70 65 60 55 50 30 40 50 60 70 80 90 100 110 120 130 140 150 Amalgam temperature (°C) www.osram.com

×