Shivani Scientific Industries (P) Ltd has vast experience of more than 20 years of designing and building pharmaceutical Laboratories as per WHO-GMP norms with stringent requirement of sterility. The …

Shivani Scientific Industries (P) Ltd has vast experience of more than 20 years of designing and building pharmaceutical Laboratories as per WHO-GMP norms with stringent requirement of sterility. The same experience has helped us to fulfill the demanding needs of to-days IVF Labs.

A new Lab means start contacting designers, architects, sellers, resellers, vendors, suppliers, agents, distributors to initiate slow, long and laborious process of discussing dates and negotiating rates. This, you will agree, will further eat into your most precious commodity "Time".


3D Lab design / 3 D Walk through
We offer State of the Art computer modeling to visualize your Lab either in 3D or 3D Walk through, even before your lab is ready.

Customised Video Processing
All modern equipments comes with all provision of image processing which is very well utilized by our Combination of hardware camera selection and software selection. Multiple Camera inputs can be synthesised in one system to have better recording and processing.

Embryology Services
We provide assistance in providing complete embryology services from Ovum Pick-up to embryo transfer. Qualified and experienced team of clinicians and embryologists are selected to provide these services.

Air Quality evaluation and improvement
We have capability to thoroughly evaluate Air quality on existing Lab and recommend appropriate steps to improve the same. It varies from HVAC inspection to microbial air sampling.

Hands on training for Lab Staff
We offers comprehensive hands on training in collaboration with Maharashtra Animal & Fishery Sciences University to Lab Staff.

Annual Maintenance of IVF Lab Equipments
We undertake Annual Maintenance Contracts for IVF Labs with the support of its highly qualified team of Engineers. We also cater to calibration contracts with our highly accurate calibration equipments.

Alternatively you have the easier and simpler option: Contact US for::

OUR PRODUCT RAGE IS:::

IVF PRODUCTS WE MAKE:

Spermfuge,Mobile Nest,Lab Guard,Warming Blocks,Ivf lab Turnkey Projects,Rapid Recovery System

IVF Division:::WE SUPPLY

Spermfuge,ThermoPlate,Embryo Freezer,System for ART,Suction Pumps for oocyte aspiration,
CO2 incubator,warming block,micromanipulator,Microscope,Micropipettes,Clean Air System,
FertAid,Embryology Academy of research Training.

Autoclaves & Sterilisers:::WE MAKE

Double Wall,Autoclave,Laboratory Autoclaves,Semi Automatic,Portable Autoclave,
Semi Automatic,Gas cum Electric,Autoclave Horizontal Sterilizer,
Fully Automatic Autoclaves GMP Compliant Series,Acculeak Detector

Published in Economy & Finance , Business
  • Full Name Full Name Comment goes here.
    Are you sure you want to
    Your message goes here
    Be the first to comment
    Be the first to like this
No Downloads

Views

Total Views
3,145
On SlideShare
0
From Embeds
0
Number of Embeds
0

Actions

Shares
Downloads
53
Comments
0
Likes
0

Embeds 0

No embeds

Report content

Flagged as inappropriate Flag as inappropriate
Flag as inappropriate

Select your reason for flagging this presentation as inappropriate.

Cancel
    No notes for slide

Transcript

  • 1. TECHNICAL SPECIFICATION Blower-German make : Backward impeller type Pre Filter : Synthetic PU washable Hepa Filter : Efficiency 99.97% @ 0.3 microns VOC Filter: : Unique blend of activated carbon and alumina Unit capacity: : 350 CFM Lab Guard Mounting: : To be done outside VF Lab on any Wall Power consumption: : 90 Watts maximum Filter replacement as per auto indication Electrical supply : 100/110 volts OR 220/240 volts 50/60 Hz Positive Pressure System specifications subject to change without notice Ordering information LG 300 Lab Guard LG 300 100 120 Volts 60 Hz order code FX 2045 Lab Guard LG 300 220 240 Volts 50 Hz order code FX 2046 Spare Filter Set order code FX 2047 Return Blower order code Fx 2048 Dimensions 590 mm 470 mm 800 mm Traceability calibration in accordance with C For more details go to national and international standards, NIST USA www.shivaniscientific.com Q Individual and expressive quality control certificate Shivani Scientific Industries (P) Ltd Tel - + 91 22 2845 6768 26A Raju Industrial Estate, Penkar Pada Road + 91 22 2845 6769 Near Dahisar Check Naka, Mira-401104 + 91 22 2845 6770 Dist. Thane (Mumbai) Maharashtra, INDIA e-mail sales@shivaniscientific.com Fax - + 91 22 2845 7140 ssipl@bom5.vsnl.net.in + 91 22 2845 6766 Distributor We make it possible Guard Lab Pressure System Positive Lab Guard LAB GUARD Split A/C Positive Pressure System DESIGN The LAB+GUARD has been designed with State IVF LAB LG 300 of the Art technology using 4 stage filtration UTILITY system. The unique filter combination filters out ROOM LAB GUARD air and gas contaminant thus by giving most suitable air for gametes and embryos. LAB+GUARD system contains a unique 4 stage Blower Return filtration system containing Prefilter, Hepa Filter and unique blend of activated carbon and alumina, which ensures wide variety of Gases, particular contaminants are oxidized or are CONCEPT Fresh Air absorbed. The LAB+GUARD has been designed to reduce the microbial air flora to the minimum The LAB+GUARD is developed to improve the level. OPERATING SECURITY RETURN BLOWER laboratory air quality making it nearly equal to clean air. Thus replenishing and subsequently REDUCES CFU, REDUCES VOC The return blower is utilised to circulate back the Every care has been taken in designing to make nourishing the entire laboratory, making it safe for air of IVF lab to room where LAB+GUARD has sure that air absorbed is thoroughly cleaned The unique design and the concept of the sensitive procedures to be executed. This is been fitted. for contaminants and to reduce bacterial count in LAB+GUARD positive pressure system not only achieved by a number of inclusions and their IVF Lab. The LAB+GUARD design also facilitates reduces VOC content in the air but also the CFU applications all of which are simple, cost effective introduction of fresh air into the air circuit which UPGRADING, EXPANDING OR count in the IVF Lab. The LAB+GUARD not and user friendly. gives maximum safety from Carbon dioxide only protects embryos and gammas but also SETTING UP NEW IVF LAB? The positive pressure system uses the basic released into the IVF Lab by CO2 Incubators and protects embryologists who is the most affected principle of “Over Pressure or positive pressure in also it protects embryologists from gas mixtures The LAB+GUARD team helps you in evaluation of otherwise. a room which restricts the entry of outside air”. released on work stations. possibilities to improve air quality in your lab. If This is achieved by absorbing the circulating air you are upgrading, expanding or setting up new outside the IVF Lab (Room) and then lab contact us for technical assistance. CHANGE FILTERS AS PER USAGE subsequently passing the same through a series of 4 stage filters thus making it quite IVF friendly. The LAB+GUARD also houses a unique Thus ultimately the effective, circulating air in the automatic indication system whereby the user is WHO BREATHS CO2 IVF lab reaches a near clean air status, provides a informed when to change the filters, and not positive pressure, reduces the CFU count, IN YOUR IVF LAB ? “every quarterly”. This feature not only gives eliminates the SPM, VOCs and CACs. tremendous relief to the user for tracking the If your lab does not have regulated fresh air intake or stipulated time of change but also saves lot of positive pressure design, there are every chances ENSURE NET FLOW OUT money. that your embryologists are breathing out CO2 tanks In any HVAC/air flow design it is essential that net MAINTENANCE emptied ever year. Since CO2 can not be absorbed flow is going out of the room. This means room air or filtered by Indoor air purifiers or filters. The volume and pressure should be slightly higher The LAB+GUARD has automatic indication for LAB+GUARD facilitates introduction of fresh air and than adjoining areas/rooms. This will keep out Filter change and the design facilitate extremely any toxic fumes trying to come in. IVF labs which easy replacement of filters even by non technical reduces the risk of high CO2 concentration into the are not having adequate positive pressure are staff. Other than filter change it is virtually IVF Lab. suceptible to risk of contamination. maintenance free.