                PROGNOSTICHECK
                  Product Overview

                    How it works

                   ...
Product Overview
• The Phase Angle of a biological entity provides a reliable and objective index
  of prognosis by illust...
Product Overview

                                Applications

Document POA conditions                Hospice            ...
Product Overview
•Impedance Plethysmography (IPG): the gathering of a variety of physiologic
 data based upon the measured...
Product Overview
                                 Accurately illustrate physiologic
                                 (path...
How it Works?
• Our body is made of materials that have varying degrees of conductivity based
 upon water and cells.



  ...
How it Works?
• The measured impedance is vectored into two parts; Resistance (R) and
  Reactance (Xc) and the relationshi...
How it Works?
• Xc is proportionate to cell mass so when you are healthier and better
  nourished Xc is higher and when yo...
How it Works?
• The Pa is the relationship between R and Xc defined mathematically (arc
  tangent Xc/R expressed in Degree...
Why use it?
• Changes in R, Xc and Pa do not explain the reason for the change and they
must be taken in the context of th...
Why use it?
• Since IPG values reflect what is happening at cellular- they act as a "early
  warning system".



         ...
Why use it?
• In addition the characterization of the cell membrane and the exchange it
mediates between the intracellular...
When to use it?
•The frequency of the measurement is based upon the phenomenon to be
captured and illustrated.


         ...
R
                PROGNOSTICHECK
                  A BIOLOGICAL COMPASS TM




                   By Michaeal Singer

    ...
Upcoming SlideShare
Loading in...5
×

PrognostiCheck® device measures prognosis. Reliable, Objective and Noninvasive.

453

Published on

Prognostic scoring system objectively and accurately detects the presence and severity of illness, the effectiveness of treatment, the existing burden of illness, the progression of disease and the timing of non-acute death.

0 Comments
0 Likes
Statistics
Notes
  • Be the first to comment

  • Be the first to like this

No Downloads
Views
Total Views
453
On Slideshare
0
From Embeds
0
Number of Embeds
1
Actions
Shares
0
Downloads
0
Comments
0
Likes
0
Embeds 0
No embeds

No notes for slide

Transcript of "PrognostiCheck® device measures prognosis. Reliable, Objective and Noninvasive."

  1. 1. R PROGNOSTICHECK A BIOLOGICAL COMPASS TM By Michaeal Singer www.ipgdx.com michaealsinger@ipgdx.com www.ipgdx.com
  2. 2. R PROGNOSTICHECK Product Overview How it works Why use it? When to use it? www.ipgdx.com
  3. 3. Product Overview • The Phase Angle of a biological entity provides a reliable and objective index of prognosis by illustrating the unique individual patients burden of illness, treatment response, potential for complications and the timing of their non-acute death. Treatment Response R PrognostiCheck Report Operating Room Treatment • Presence and Patient severity of Potential for Complications disease. • Effectiveness Non of Treatment. Invasive Patient Info Progress Report Timing of non-acute death Wheel Chair Deceased www.ipgdx.com
  4. 4. Product Overview Applications Document POA conditions Hospice Support improved clinical /severity for MS-DRG decision making Objectively allocate Reduce DRG overstay resources & pay-backs www.ipgdx.com
  5. 5. Product Overview •Impedance Plethysmography (IPG): the gathering of a variety of physiologic data based upon the measured electrical conductive properties of the body. •IPG has been effectively used for over fifty-years in a variety of clinical medical practice and research applications. IPG has a well established history of use. Detection of blood clots that Estimating the blood Body composition may lead to serious illness pumped by the heart analysis • Venous thrombosis • Left Ventricular • Estimating body fat /pulmonary embolism. Ejection Fraction www.ipgdx.com
  6. 6. Product Overview Accurately illustrate physiologic (pathophysiologic) parameters. Non Invasive. IPG Precision of IPG that makes it a valuable tool. The changes it documents are the changes inherent in the biological system. • In our applications of IPG we have chosen to provide only the specific measured electrical values, the understanding of what their physiologic equivalents are and to compare those results in a visible illustration. • This qualitative standard provides the basis for a reliable decision matrix suitable for clinical practice that is understandable to patient and provider forming the basis of a practical health-tool. www.ipgdx.com
  7. 7. How it Works? • Our body is made of materials that have varying degrees of conductivity based upon water and cells. To make the measurement the subject becomes the only unknown part of a safe electrical circuit. The circuit is safe because the signal that is used is at a frequency and strength (current and voltage) so as not to stimulate or disturb any tissues. The measurement can be repeated as often as necessary to illustrate and report the information sought. www.ipgdx.com
  8. 8. How it Works? • The measured impedance is vectored into two parts; Resistance (R) and Reactance (Xc) and the relationship between them is calculated as the Phase Angle (Pa). : Is a fluid Indicator Resistance (R) 1 : R= Water Content of Body. 70% water • Conduction is improved • Resistance is lessened 30% water • Conduction is reduced • Resistance is greater www.ipgdx.com
  9. 9. How it Works? • Xc is proportionate to cell mass so when you are healthier and better nourished Xc is higher and when you are less healthy or nourished Xc is lower. Higher Xc Value • More cells and healthier cells. • Greater capacity to 'hold' the electrical energy. • Subject is well nourished. Lower Xc Value • Fewer and less healthier cells. Blood Cells • Lower capacity to 'hold' the electrical energy. www.ipgdx.com
  10. 10. How it Works? • The Pa is the relationship between R and Xc defined mathematically (arc tangent Xc/R expressed in Degrees). increasing frequency Reactance ( ) The average Phase Angle is from 50 to 90 -The higher the value the better the health. < 4o denotes serious illness and an opportunity for aggressive intervention. Continued diminution denotes worsening condition and if in the presence of aggressive intervention: non-response. <2o impending death (unrecoverable). www.ipgdx.com
  11. 11. Why use it? • Changes in R, Xc and Pa do not explain the reason for the change and they must be taken in the context of the overall health of the subject and used in addition to the existing clinical dataset. • However their value is that they clearly and reliably illustrate change before changes are seen through typical methods such as a blood chemistries/cell counts, physical signs or imaging techniques. Illness Changes www.ipgdx.com
  12. 12. Why use it? • Since IPG values reflect what is happening at cellular- they act as a "early warning system". Valuable time to act To detect disease IPG values To improve treatment End-of-life management www.ipgdx.com
  13. 13. Why use it? • In addition the characterization of the cell membrane and the exchange it mediates between the intracellular and extracellular environments illustrates the condition of the subject unlike any other methodology providing valuable information and insight. Extracellular Environment Illustrates Cell membrane Intra cellular environment Condition of Human body • Helpful to assess and maintain general health. • To detect the presence of disease. R, Xc and • Characterize its progression. Pa • Measure effectiveness of Treatment. Measurement • Optimize treatment. • Transition to supportive care based upon objective values. • Patient and family can understand. www.ipgdx.com
  14. 14. When to use it? •The frequency of the measurement is based upon the phenomenon to be captured and illustrated. General Health Related • To assess the condition and effects at hand to adjust health practices. Illness Related IPG • More frequently Measurement • To show what changes are occurring over time for to demonstrate recovery or to support further more definitive investigation. Serious Illness Related • Multiple times per day • To capture and track fluid changes which may occur rapidly (in hours). www.ipgdx.com