Your SlideShare is downloading. ×
UCE 9000T USer's Manual
Upcoming SlideShare
Loading in...5
×

Thanks for flagging this SlideShare!

Oops! An error has occurred.

×

Saving this for later?

Get the SlideShare app to save on your phone or tablet. Read anywhere, anytime - even offline.

Text the download link to your phone

Standard text messaging rates apply

UCE 9000T USer's Manual

21,716
views

Published on

Published in: Technology, Business

0 Comments
0 Likes
Statistics
Notes
  • Be the first to comment

  • Be the first to like this

No Downloads
Views
Total Views
21,716
On Slideshare
0
From Embeds
0
Number of Embeds
13
Actions
Shares
0
Downloads
43
Comments
0
Likes
0
Embeds 0
No embeds

Report content
Flagged as inappropriate Flag as inappropriate
Flag as inappropriate

Select your reason for flagging this presentation as inappropriate.

Cancel
No notes for slide

Transcript

  • 1. • The consumer accepts any and all responsibility and/or liability if replacement filters and/or parts are not manufacturer specific.• This product is subject to changes that enhance its performance without prior notification. pH ChartHow to Measure: Place 2-3 teaspoons (10-15 ml) oftest water in a container and add 2-3 drops of reagent.Then, mix well and check color of the water with thepH chart above. (Color is dependent on water qualityand reagent) MADE IN KOREA under counter extreme Tyent USA, LLC. 855-TYENT-USA (893-6887) www.tyentusa.com UCE-9000t instructions manual
  • 2. To our Valued Customers Table of Contents Thank you for purchasing the UCE-9000 Turbo Water Ionizer. To Our Valued Customers ................................................................ 2 Before Usage.................................................................................... 4 Please read all safety warnings and this User’s Manual carefully Safety Precautions and Warnings.................................................... 5 before using this product to ensure proper product usage. (Keep Product Specifications .....................................................................7 the manual handy for easy reference.) Product Features ............................................................................. 8 • We are not responsible for any accidents and/or malfunctions Package Contents ..........................................................................12 due to the improper use of this machine. Product Overview ..........................................................................13 How to Install the Product.............................................................14 • Please keep the manual and warranty card in a safe place, so Water Hose and Cable Installation ................................................15 that it’s easily accessible when you need it. Layout Diagram ..............................................................................16 • Please refer to this manual often when you have questions Dispenser Installation ....................................................................17 during usage or when troubleshooting this unit. Dispenser Overview.......................................................................19 Touch Screen Overview ................................................................. 20 Navigating the System................................................................... 23 • Using the Display.................................................................... 23 • Setting the Time..................................................................... 24 Intended Use • Setting the pH Levels ............................................................. 25 • Voice and Volume .................................................................. 26 • Cleaning Function .................................................................. 27 This device creates functional alkaline, ionized water. It changes the properties of regular tap water through the use of • ECO Mode............................................................................... 27 electrolysis. Following are the changes normal tap water • Turbo Mode ............................................................................ 28 undergoes via this process: User Serviceable Parts .................................................................. 29 • Replacing the Filters...............................................................30 • An increase or decrease in pH level • Changing the Fuse ................................................................. 31 • Creation of negatively charged hydrogen ions (anti-oxidants) • Smaller water molecule clusters for better absorption • Temperature Sensor............................................................... 32 • An increase in oxygen Usage Recomendations ................................................................. 33 • Purification through filtration Troubleshooting ............................................................................. 342 UCE-9000t under counter extreme instructions manual 3
  • 3. Before Usage Safety Precautions and Warnings Safety precautions are provided for the safe and proper use of Do not use if the power In case unit leaks (other cord is damaged or in a than hoses) or is standing this unit and can prevent danger, bodily harm and/or possible loose power outlet. in puddle of water, shut off damage due to misuse. Please make sure you are familiar with water supply, unplug the all the safety precautions and warnings associated with this unit. power cord and refer servicing to qualified service personnel. Do not pull the power cord. Never touch power Replace filters every 6 cord or power outlet with months to optimize the wet hands. purification performance DANGER WARNING ATTENTION of this unit even if the (Red Warning Sign) (Orange Warning Sign) (Yellow Warning Sign) replacement indicator light indicates an imminent hazard indicates a potential hazard that indicates a potential hazard that that could result in serious injury could result in significant bodily could result in minor bodily harm Do not use power surge isn’t turned on. or death. If you see this, stop the harm or damage to the unit. If you or damage to the unit. protectors with this unit. use of this unit immediately. see this, stop the use of this unit. Use unit with its own Do not use alkaline or dedicated power source. acidic water in fish bowls PLEASE FOLLOW ALL INSTRUCTIONS WHEN YOU DRINK or aquariums. The sudden WATER CREATED BY ELECTROLYSIS FROM THIS UNIT. Do not forcibly bend, change in pH could be squeeze, damage or crush harmful or fatal to some (Hereinafter referred to as “functional water”) the power cord under marine life. 1. Do not drink functional water with monthly basis to ensure proper function. heavy objects. medication. Use filtered Water instead. This can be done with the supplied To reduce the risk of reagent drops and a pH color chart. Unplug the power cord electric shock, do not 2. Always consult your primary care during general remove cover; no physician before drinking functional 7. When switching from one pH to another, water. Only drink a small amount for the it is good practice to let the water run for maintenance, repair, user-serviceable parts first week near a neutral pH level. This several seconds before using. inspection and while inside. Refer servicing to will give the body time to adjust to replacing parts. qualified service functional water during the 8. It is common to drink half your body personnel. Removing the detoxification period. weight in ounces. For example, if you weigh 180 pounds, it may be wise to Only use the unit with the cover will void the 3. If you notice any negative effects from drink 90 ounces of water per day. This correct voltage. warranty. drinking functional water, stop drinking especially applies after you have given immediately and consult with your your body some time to adjust to the Do not spray water on the primary care physician about changes in new pH level. your body’s pH level. main unit. Do not clean 9. 9.5 to 9.8 pH is the recommended Do not place ANY objects with a damp cloth, 4. If you are currently under the care of a drinking level for functional water. It is on top of this unit benzene or other primary care physician for an existing not recommended to drink functional regardless of how small. chemicals, which may leak condition, consult with your primary water above 10 pH. into the unit. care physician about how changes in pH and other characteristics of functional 10. If you wish to store functional water, use water could affect your condition. a glass, stainless steel or other Do not store unit near non-leaching material and store in the In case of strange noises, chemicals, food, metals or 5. If you suffer from gastric anacidity, refrigerator. burning odor or smoke, medication. kidney failure or potassium excretion, unplug the power cord you should not drink functional water. 11. Never run hot water through this unit. immediately and refer Do not poke or scratch the 6. Verify the pH levels of the functional 12. Never drink acidic water. servicing to qualified touch pad or LCD display water dispensed from this unit on a service personnel. with sharp objects.4 UCE-9000t under counter extreme instructions manual 5
  • 4. Safety Precautions and Warnings Product Specifications It is beneficial for the In case the original maintenance of the packaging is not available, Product Name Under Counter Extreme Water Ionizer machine to run a strong cover the unit in plastic to acidic level for a period of avoid scratching the 5 minute cycles twice surface. Model Number UCE-9000 Turbo weekly. This will help to maintain a clean chamber. Carefully remove this unit Pufirying Mode TM Filtration Mode from packaging. Keep Do not place this unit near original packaging for heat sources. future storage and unit Rated Power AC100V~AC130V, AC200~AC240V/50Hz~60Hz transportation. Power Do not connect water line Consumption Max. 374.4 VA to a hot water supply. Store unit in its original packaging in a cool, dry Available Temperature 39º-95º F (4º-35º C) place when not in use. Do not place this unit on an uneven surface. Do not Operating drop or use excessive 0.1 ~ 0.5 MPa force on this unit. Pressure Range pH Levels 3 Alkaline, 1 Neutral, 3 Acidic, Turbo Do not use unfit raw water in accordance to the standards of the water Adjustable pH User adjustable pH levels control service act. Filter 2 Filters System Configuration Do not use in areas of high humidity and/or high Filter LCD filter replacement and announcement temperature. Life Display Quantity of 9 In the case where the unit isn’t used over a long Poles in Cell period of time, shut off the valve and unplug the Plate Materials Platinum and Titanium power cord. Dispenser: 2 d x 12.7 h in. (5.8 d x 32.35 h cm) Remove filters and shake Product Size Ionizer: 14 w x 5.2 d x 14 h in. (36 w x 13 d x 35.5 h cm) out as muchas possible. Dispenser: 1.1 Lbs. (0.5 Kg) Store in plastic bag in Product Weight Ionizer: 15.2 Lbs. (6.9 Kg refrigerator to avoid bacteria growth in filters.6 UCE-9000t under counter extreme instructions manual 7
  • 5. Product Features A DESIGN MASTERPIECE MORE POWERFUL SYSTEM ENGINE Offering both, Kitchen Space and Ultimate Beauty Upgraded POWER TURBO SYSTEM The TyentUSA’s Under Counter Extreme Water Ionizer not Turbo upgrades to the SMPS Power Supply system only attracts a person’s gaze with its well-differentiated produce both the acid turbo water and strong alkali water appearance, but also helps to upgrade your kitchen’s you need! interior decoration with a neat and luxurious expression. FULL TOUCH LCD - TRANSFORMATION AT YOUR FINGERTIP POWER SMPS Power Supply System The Industry’s First Full Touch Screen Panel POWER SMPS Power Supply System provides the The Full Touch Screen Panel System automatically maximum instantaneous output needed to produce the activates the unit’s operations through a simple touch to highly stable electric power required for each phase of the desired icon displayed on the screen. electrolysis. 9 Electrodes with Round-Mesh Plate Technology Touch LCD Screen with a Clear Picture Tone These 9 Platinum-Coated Titanium Plates are made with highly stable, durable mesh technology that enhances the A 262,000 Color Touch LCD Display provides diverse instantaneous electrolysis efficiency. information in true vivid colors for user convenience. CAREFUL CONSIDERATIONS FOR THE USER GUI [Graphical User Interface] Light and Screen Indicators for Water Discharge A Graphical User Interface is designed specifically for ease Detection of use and operation. Communication between the user and ionizer has never been this simple! Changes to the LCD screen and Jog Dial light can be easily identified to check each selected phase. JOG DIAL AND TOUCH Jog Dial & Touch with 2 way Operation Compatibility Excellent MP3 Sound Quality with Guided Support Choose from either the Jog Dial or the Touch Screen Panel Functions under operation can be further identified by the system – both are available with 2 way operation top-quality voice guided system. compatibility and are easy to use at your convenience. Multiple Languages Supported CARE FOR THE ENVIRONMENT Diversified language guide support is available by selecting Earth-Friendly Technology when in ECO MODE 1 of 6 languages featured from across the world. True energy saving is accomplished with ultra low power consumption during periods of non-use.8 UCE-9000t under counter extreme instructions manual 9
  • 6. Temperature Sensor Function for Safe Operation SELF MAINTENANCE MADE EASY - FROM INSTALLATION TO AFTER-SERVICE If the temperature of the source water exceeds the normal Filter Usage Indication and Replacement Time Guide operation range of 39-95 degrees Fahrenheit, the incoming flow of water is automatically interrupted, displaying a Level of filter usage can be identified through the LCD Warning Sign on screen. Screen on a real time basis. The recommended replacement time is automatically displayed on the screen Automatic Water Discharge Interruption Function with a voice guide. In order to prevent the overflow of water due to user negligence, the water discharge is automatically stopped Super Simple Filter Replacement System after 15 minutes of use. A simple filter replacement system along with one-touch Filter Usage Initialization Setting System makes filter Automatic Electrolysis Tank Cleaning Function management easy for any one. The interior of the Electrolysis Tank is automatically cleaned on a regular basis, ensuring stable electrolysis operating conditions. Convenience of Operating Condition Setting System Easy Setting System familiar to common users is Automatic Memory Function employed, allowing the convenience of setting or canceling the desired through the LCD Screen. The last function used by the user is automatically memorized and displayed on the Standby Screen for fast and convenient operation. pH Control Function Water Discharge Nozzle with Directional Control Respective alkali, acid & turbo phases can be easily controlled by the user. The water discharge direction may be adjusted to many diverse angles based on user preference. Self Diagnosis Function FRESH, PURIFIED WATER IS A MUST ALONG WITH HEALTHY MINERALS When the condition of the source water is not suitable, the water discharge is automatically suspended, displaying a Water Purification through a Clean Process Warning Sign on screen. Perfect, seamless elimination of foreign substances including residual chlorine, organic and inorganic compounds through the filtering process using functional UF and Ceramic materials, enhancing the alkali water producing condition.10 UCE-9000t under counter extreme instructions manual 11
  • 7. Package Contents Product Overview Ionizer FRONT VIEW REAR VIEW dispenser fixing nut rubber packing (2EA)  Front Case  Hanging Groove Water Outlet Pipe  Front Cover  Rear Case  Front Door Case  Product Sticker  Power Switch  Fuse Cable Tie  Power Cord Wrench BOTTOM VIEW Tap Water hose Stem Elbows (3EA) Acid hose (Orange) & Alkaline hose pH Testing (White) Solution Bottle  Alkaline Outlet  Acid Outlet  Tap Water Inlet AL NU MA  MCU Cable  Power Code User’s Manual12 UCE-9000t under counter extreme instructions manual 13
  • 8. How to Install the Product Water Hose and Cable Installation  Press the stem elbows into the water inflow, alkali outlet and acidic outlet located on the bottom of the ionizer. To remove the shipping plugs located in the ports of the bottom of the unit, the wrench provided will assist in this operation, depressing the releasing flange with the wrench while lifting up on the plug. acid hose  Connect the hoses of the dispenser to the stem elbows. (when you connect the hoses, use orange for the acid hose and white for the alkaline hose) alkaline hose 1. Purchase either an under-sink installation kit (not included) or  Connect the MCU cable of the dispenser purchase T-connection (with shut-off valve) from a hardware or to the MCU cable on the bottom of the plumbing supply store. ionizer. 2. Shut off both hot and cold water main supply at pipe under the sink. 3. Locate the cold water supply line valve. 4. Disconnect faucet cold water supply line from main cold water  Connect the hose from the inflow hole pipe–use towel to catch small amount of water that may come from tap water inlet to the cold water supply at the faucet supply line. under-sink T-connection. 5. When connecting T-connection to cold water pipe, be sure to use plumbing pipe thread seal tape (not included) to prevent leaks. 6. Reconnect faucet cold water supply line to T-connection. (now secured to main cold water pipe)  Make sure all hose connections are firmly seated in the correct holes, both 7. Be sure all connections are secure but do not over tighten. on the unit and at the water supply. *Do not turn on main water supply until all hoses are properly installed to the unit.14 UCE-9000t under counter extreme instructions manual 15
  • 9. Layout Diagram Dispenser Installation  First, remove the fixed nut from the dispenser. Dispenser Water Outlet Pipe  Press the outflow pipes into the holes of the dispenser. Rubber packing • Upper hole: water outlet pipe (6 inches [152mm]) Rubber packing • Lower hole: drain pipe (4 inches [102mm]) Bottom Drain Pipe Fixing nut Tap water inlet Alkaline hose  Connect each hose from the dispenser Acid hose Acid outlet MCU cable From Ionizer Acid hose to a union connector. Connect each hose from the ionizer to the union Union connector connector. When you connect the Alkaline hose hoses, please match the hoses by color: Stem elbow Alkaline outlet water hose Tap i.e., orange – orange, white – white MCU cable connector From Dispenser Cable tie  Use the provided center guide sheet to 32mm mark the drilling points in the sink MCU cable before drilling.Use a 32mm (1 ¼ inch) drill bit to drill a hole. Adapter  Insert one of the provided rubber O-Rings in the assembled dispenser. Ionizer Tap water hose16 UCE-9000t under counter extreme instructions manual 17
  • 10.  Place the assembled dispenser into the Dispenser Overview drilled hole. FRONT VIEW REAR VIEW  Insert the second rubber O-ring in the assembled faucet located underneath the sink.  Tighten the fixing nut underneath the sink. (Do not over tighten) 16 cm 6.3 in 29.5 cm 11.6 in 11 cm 38.2 cm 4.3 in 15 in 17.2 cm 13.2 cm 6.8 in 5.2 in  Plug in the power cord and turn on the unit. 3.3 cm 1.3 in SINK 5 cm  The INTRO Screen appears only when 2 in initial power is supplied.  Jog Dial  Water Outlet Pipe  Drain Pipe  Fixing Nut  Speaker (Rear View) Caution: In the event of a power failure Remove the power cord from electrical socket and shut off source water valve.18 UCE-9000t under counter extreme instructions manual 19
  • 11. Touch Screen Overview STAND - BY MODE MENU WINDOW Push the upper part of LCD Screen. MENU Window appears below the Display line of the upper part of LCD Screen. set status Set up mode (page 24) Voice on/off (page 26) Functional Water Operation Cleaning mode (page 27) ECO mode (page 27) Display line of filter usage [default: 0%] Push the bottom part of LCD Screen. MENU Window appears above the bottom part of the LCD Screen. ICON DESCRIPTION Set up Alkaline water level 1 Voice on Alkaline water level 2 Voice off Alkaline water level 3 Cleaning mode Purified water ECO mode on Turbo water Filter 1 reset ECO mode off Acidic water level 1 Filter 2 reset Filter 1 usage Acidic water level 2 Filter 2 usage Acidic water level 3 Caution: Use the Filter Initialization Icon only after the filters have been changed.20 UCE-9000t under counter extreme instructions manual 21
  • 12. LCD DISPLAY CAUTIONS WHEN USING THE TOUCH SCREEN Selected mode 1. Due to the uniqueness of the TOUCH Screen, TOUCH is not recognized if pushed by more than one finger. Please push Auto flow stop time indicator with only one finger and be careful of contamination to the screen that may cause damage to the TOUCH. 2. Be careful of electrostatic materials near the TOUCH Screen. Stimulation from such materials may cause damage to the TOUCH. Working indicator 3. Screen may not be seen well under direct sunlight. 4. Do not push the Screen hard with sharp or pointy objects. DISPLAY COLORS Navigating the System Backlight of LCD display will match the pH level color according to water pH level being used after icon is pressed. System setup is used to select the pH level, control volume, set the time and select voice language. WHEN USING THE JOG DIAL  Turn dial  Screen Alkaline Water 1 Alkaline Water 2 Alkaline Water 3 Acidic Water 1 Acidic Water 2 Acidic Water 3 Clean Water Turbo either changes to Sky Blue Back-Light Blue Back-Light Violet Back-Light Yellow Back-Light Orange Back-Light Deep Pink Back-Light Green Back-Light Red Black Back-Light direction selected to select color. Push MESSAGE DISPLAYS function, center of dial white to start water means it’s selected. outflow.  Push  When done, center of screen moves When this is When this is When this is When this is displayed, it is time displayed, water displayed, there has displayed, the unit dial to to last used to replace the filters inside the unit is been a suspension is being cleaned stop icon and, into (page 30-31). higher than 95ºF of water supplied to which can be done water stand by (35ºC). The water the unit, issuing this automatically outflow. mode. supply will then be message prior to and/or manually shut off and the stopping water (page 27). unit will stop outflow. operating (page 32).22 UCE-9000t under counter extreme instructions manual 23
  • 13. WHEN USING THE TOUCH SCREEN ALKALI PH LEVEL ADJUSTMENT  Press the  Water  Press the top  Select desired outflow left corner of “ALKALI ph” icon on starts. screen. MENU the LCD Screen options will fall screen displays below upper current part of screen. level and stop time.  Press the setup icon  Press the  When  Select desired level. screen to done, stop the screen  : LEVEL Up (14%, 15%, 16%...)* flow of moves to : LEVEL Down (12%, 11%, 10%...) water. last used icon and, into stand Alkali pH Level Adjustment is complete. by mode. * If UP/DOWN button is pushed, digital number moves by 1 step SETTING THE TIME ACIDIC PH LEVEL ADJUSTMENT  Press the top  Select  Press the top  Select left corner of “TIME” left corner of “ACIDIC ph” screen. MENU screen. MENU options will fall options will fall below upper below upper part of screen. part of screen.  Press the  Press the setup icon setup icon a Year  Adjust time  Select desired level. b Month and date with the  : LEVEL Up (18%, 19%, 20%...)* c Day arrows: : LEVEL Down (16%, 15%, 14%...) d Hour for up e Minute for down Acidic pH Level Adjustment is complete. Time Set up is complete * If UP/DOWN button is pushed, digital number moves by 1 step Push RETURN Icon for previous menu screen. Voice says: “Applied”. Push RETURN Pushing RETURN Icon twice will complete set-up for all the operations in Icon again to complete set-up. Voice says: “Set-up Complete”. pages 24, 25 and 26.24 uce-9000t under counter instructions manual 25
  • 14. VOLUME LEVEL ADJUSTMENT CLEANING FUNCTION  Press the top  Select  Press the top  Select the left corner of “VOLUME” left corner of cleaning screen. MENU screen. MENU icon options will fall options will fall below upper below upper part of screen. part of screen.  Press the setup icon  Select desired VOLUME by pushing  Cleaning can take place automatically and/or manually • Auto Cleaning (15 Seconds) is performed during water outflow after more than 12 hours Volume set up is complete of non-operation OR after 30 liters of water outflow. • Manual Cleaning (15 Seconds) is performed whenever desired simply by touching the icon. SELECTING VOICE ON /OFF ECO MODE  Press the top  Select the  Press the top  Select the left corner of voice left corner of ECO screen. icon screen. icon MENU MENU options will options will fall below fall below upper part of upper part of screen. screen.  The voice will be turned on/off by selecting the voice  ECO Mode will be turned on/off by selecting the icon in this sequence. ECO icon in this sequence. When ECO MODE is set, unit consumes less power during periods of non-use. The screen will become blank if ECO MODE is set after 1 minute after using the unit. If the screen is touched, it changes to Standby Mode by displaying last screen used.26 UCE-9000t under counter extreme instructions manual 27
  • 15. User Serviceable Parts TURBO MODE ATTENTION: The consumer accepts any and all responsibility and/or liability if replacement filters and/or parts are not manufacturer The TURBO Function allows you to create strong alkaline and acidic specific. This unit contains high-performance purifying filters and an water. These types of water are ONLY to be used for cleaning, sanitizing advanced control system. and disinfecting purposes. Primary Filter: ACF Filter pH 2.5 Used to Disinfect ~ pH 3.8 and Sterilize Recommended filter replacement cycle: 951.0 gallons (3,600 L) / Every 6 months To remove stains pH 10.0 from fabrics/carpet/ Removes harmful chemicals like chlorine, ~ pH 11.8 upholstery. compounds such as agrichemicals and detergents, large suspended matters like rust and sediments as well as other volatile organic compounds through an efficient, activated absorption method. It also eliminates bad smells and any remaining dissolved chlorine. Secondary Filter: Ceramic Filter Recommended filterreplacement cycle: 951.0 gallons (3,600 L) / Every 6 months 0.01 micrometer artificial film filters contaminated materials including ordinary bacteria while maintaining essential minerals in the water. Alkaline Turbo Water Outflow Acidic Turbo Water Outflow Caution: The waters produced in TURBO mode are not intended The life of the filter may vary greatly due to use, water pressure, water for drinking. DO NOT DRINK these types of waters. DO quality and seasonal changes. Filters may need to be replaced sooner NOT use the TURBO function in a manner other than than the scheduled time due to these varying conditions, as you may directed. notice reduced water quality or water taste changing for the worse.28 UCE-9000t under counter extreme instructions manual 29
  • 16. CHANGING THE FILTERS RESETING THE FILTERS  Turn the power off and unplug the power cord. Shut off the water supply to the unit. Make sure the faucet is shut off.  Filter 1 reset  Open the front door of the unit. Beware of the 1 2 sharp corners of the cover of the unit when opening.  Filter 2 reset filter 1 filter 2  First Filter Reset Press the bottom part of LCD Screen. MENU Window appears upper the bottom part of LCD Screen. To initialize, press the “F1 RESET”  Pull the filter towards you so that it will be icon 2 times. LCD displays percentage (%) of initialization of filter. easier to turn. The filter will turn more freely filter 2 when tilted at a slight angle. Remove the filter filter 1 by rotating the filter counter-clockwise. Install  Second Filter Reset Press the bottom part of LCD Screen. MENU Window appears upper the new filter by turning it clockwise. Hand the bottom part of LCD Screen. To initialize, press the “F2 RESET” tighten only. Tilt the filter back into its original icon 2 times. LCD displays percentage (%) of initialization of filter upright position.  Close the cover of the unit. Caution: Use the Filter Initialization Icon only after Filter is changed. CHANGING THE FUSE filter 1 filter 2  Unplug the power cord.  Locate the fuse cap on the lower back of the unit and turn it counter- clockwise to remove it.  Pull out the blown fuse and insert a new fuse.  Plug the power cord back in, turn the water  Replace the fuse cap. supply back on and switch the unit back on. Important Information Please be sure to contact manufacturer to obtain the correct fuse. Customer accepts all reponsibility for damage to unit and other property due to the installation of incorrect fuse.30 UCE-9000t under counter extreme instructions manual 31
  • 17. Usage Recommendations Light Alkaline Water Light Acidic Water (Drinking Level 1) (DO NOT DRINK) For TEMPERATURE SENSOR Suitable for initial washing hands, stage of drinking. face.  Should water with a temperature higher than In flow 95ºF (35ºC) get into the unit, the water supply will automatically be shut off and the unit will stop operating. 4ºC or 35ºC ºC Medium Alkaline Medium Acidic Water (Drinking Water (DO NOT Level 2) For making DRINK) For washing  LCD: “TEMP ERROR” coffee, tea and for vegetables and watering plants. fruits. Strong Alkaline Strong Acidic Water Water (Drinking (DO NOT DRINK) For Level 3) For washing washing dishes. vegetables, dishes and making rice. Clean Water Creates TURBO Function {DO purified water. For NOT DRINK) Strong taking medications acid/ alkaline water and making baby that must be used formula. when cleaning, disinfecting, washing and sterilizing.32 UCE-9000t under counter extreme instructions manual 33
  • 18. Troubleshooting Before requesting service, please make sure to check the 6. Leaks from the Filter or Unit following: A. Check the filter is installed correctly B. Check the inside of the product (excluding the filters) for any signs 1. Water tastes abnormal of leaks A. Check how long the unit has not been in use i. Immediately unplug the power cord and contact the service i. Operate the unit normally for a few minutes to drain stagnant center water. ii. Be sure all hoses are firmly seated in correct connections. B. Check to see if the filters need replacing. i. Call to have the filter replaced. 7. Hazy substance settles down on the bottom of the container filled with functional water 2. NO water outflow or the amount of water generated is A. Check if calcium ions and carbonic acids bond together in water different from specified forming deposits A. Be sure the water supply is on i. Depending on the quality of raw water, calcium is extracted i. Open the valve from the water. There is no problem in drinking water with B. Check if the hose is bent or folded calcium. However, it is recommended that you contact the service i. Stretch out the hose center in case it is a recurring problem. C. Check power settings. i. Enter setup mode and check power settings. 8. The unit doesn’t operate in cleaning mode D. Check the purifying filter for clogs A. Check if the amount of working water exceeds 6.5 gallons (30 L) i. Call to have the filter replaced B. Check if the operating time exceeds 12 hours 3. Incorrect pH levels (additional pH reagent drops can be 9. Trouble Reaching Acidic PH Values. ordered for a fee) In areas of the country where hard water (high mineral content) is A. Check water supply for hardness common, reaching lower acidic PH values can be hampered. Be i. pH levels may vary depending on region and water quality aware of your water quality and if you are having issues reaching B. Check flow rate for higher levels lower acidic values, check the hardness of your source water. The i. Slow down water supply best way to achieve a lower acidic value is to max out the power in the acidic mode of choice and slow the flow rate of the water flow 4. The filter replacement icon remains turned on even after filter through the unit, this will help create a lower acidic value. has been replaced A. Follow the filter reset instructions i. Contact the service center to initialize the filter flow rate in the System Setting Mode 5. The unit automatically stops while it’s producing functional water A. Check if the continuous operating time exceeds 15 minutes i. Water production stops automatically after 15 minutes to prevent accidental over flooding.34 UCE-9000t under counter extreme instructions manual 35