SlideShare a Scribd company logo
1 of 5
Download to read offline
K. Uday Kumar Reddy, M. Ramasekhara Reddy, Dr. M. Vijaya Kumar / International Journal
    of Engineering Research and Applications (IJERA) ISSN: 2248-9622 www.ijera.com
                   Vol. 2, Issue 5, September- October 2012, pp.1900-1905
       Modeling and Control of a Permanent Magnet Synchronous
             Generator Wind Turbine with Energy Storage
K. Uday Kumar Reddy1, M. Ramasekhara Reddy 2, Dr. M. Vijaya Kumar3
           1
             (M. Tech, Department of Electrical & Electronics Engg, JNTUACE, Pulivendula, A.P, India.)
   2
       (Assistant Professor, Department of Electrical & Electronics Engg, JNTUACE, Pulivendula, A.P, India.)
           3
             ( Professor, Department of Electrical & Electronics Engg, JNTUACE, Anantapur, A.P, India.)


ABSTRACT
         Wind energy is an important renewable              approach to self-sufficient power generation involves
source which is used for power generation for a             using a wind-turbine with a storage mechanism to
stand-alone as well as grid connected applications.         create a stand-alone system. If wind conditions are
In many remote areas, loads are usually connected           favorable, these stand-alone wind energy systems
away from the grid. In such cases, isolated wind            usually can provide communities with electricity at
energy systems can be considered as an effective            the lowest cost. Stand-alone wind energy systems
way to provide continuous power to electrical               often include batteries, because the available wind
loads. The power conversion unit features a wi nd-          does not always produce the required quantities of
turbine-driven PMSG, a d i o d e        rectifier, a        power. If wind power exceeds the load demand, the
b u c k converter, a battery bank, a feed-back              surplus energy can be stored in storage systems like
controller, and a dc/ac inverter. In this paper, an         batteries [1-3]. Multiple types of generators are being
isolated wind energy conversion system is                   used with wind turbines. Small wind turbines are
implemented using a variable speed permanent                equipped with DC generators of up to a fractional
magnet synchronous generator (PMSG) with                    kilowatt in capacity [6]. The major types of AC
PWM rectifier and a battery for storing the excess          generators that are possible candidates in wind
amount of wind energy. To change the duty cycle             turbine systems are as follows:
of the converter, a controller of DC-DC buck                • Squirrel-Cage rotor Induction Generator (SCIG),
converter with MOSFET as a switching                        • Wound-Rotor Induction Generator (WRIG),
component is designed using P, PI and PID                   • Doubly-Fed Induction Generator (DFIG)
controller to provide the efficient choice for the          • Synchronous Generator (With external field
selection of the controller. The proposed scheme is         excitation),
implemented in MATLAB using Simulink & the                  •Permanent Magnet Synchronous Generator (PMSG).
simulation results show that the output voltage of                    An induction generator (IG) has been
the converter can be controlled according to the            extensively used in commercial wind turbine units.
value of duty cycle and the excess power is stored          Asynchronous operation of induction generators is
in battery to provide balance between the                   considered an advantage for application in wind
generator and the load.                                     turbine systems, because it provides some degree of
                                                            flexibility when the wind speed is fluctuating or
Keywords:       Wind e n e r g y     conversion             variable [5-6]. The induction generator based on
s y s t e m , battery bank, Permanent magnet                Squirrel-Cage rotor (SCIG) is a very popular machine
synchronous generator, isolated system.                     because of its low cost, mechanical         simplicity,
                                                            robust structure, and resistance against disturbance
1. Introduction                                             and vibration. The induction generator based on
          Renewable sources of energy mainly                wound rotor is the doubly fed induction generator
including wind power offer a feasible solution to           (DFIG), which is a kind of induction machine in
distributed     power    generation      for     isolated   which both the stator windings and the rotor
communities where grids are unavailable. At present         windings are connected to the source [7-8].
scenario wind power has emerged as the most viable                    Another type of generator that has been
source of electric power is economically competitive        proposed for wind turbines in several research articles
with the non-renewable sources of energy. In such           is synchronous generator. This type of generator has
cases, isolated wind energy systems can be                  the capability of direct connection (direct-drive) to
considered as an effective way to provide continuous        wind turbines, with no gearbox [12]. This advantage
power to electrical loads. One of the most promising        is favorable with respect to lifetime and maintenance.
applications of renewable energy generation lies in         Synchronous machines can              use         either
the development of power supply systems for remote          electrically excited or permanent magnet (PM) rotor.
villages that lack an economically feasible means of        The PM and electrically-excited synchronous
connecting to the main electrical grid. For the type of     generators differ from the induction generator in that
loads located far from a utility grid, one practical        the magnetization is provided by a Permanent


                                                                                                   1900 | P a g e
K. Uday Kumar Reddy, M. Ramasekhara Reddy, Dr. M. Vijaya Kumar / International Journal
    of Engineering Research and Applications (IJERA) ISSN: 2248-9622 www.ijera.com
                   Vol. 2, Issue 5, September- October 2012, pp.1900-1905
Magnet pole system or a dc supply on the rotor,                  the natural laws of electromagnetic scaling, there is an
featuring providing self-excitation property. Self-              excitation penalty involved in small PM machines.
excitation allows operation at high power factors and                     As the geometrical size is decreased, the
high efficiencies for the PMSG [13]. A comparison                cross-sectional area available for copper conductor
between the variable speed wind turbine and the                  decreases with the square of the linear dimensions.
constant speed wind turbine shows that variable                  The need for the magneto-motive force decreases with
speed reduce mechanical stresses, gusts of wind can              the linear dimension, being primarily determined by
be absorbed, dynamically compensate for torque and               the length of the air-gap [14]. During the high
power pulsations caused by back pressure of the                  temperatures, the current may be sufficient enough to
tower. This backpressure causes noticeable torque                demagnetize the magnets providing excitation.
pulsations at a rate equal to the turbine rotor speed
times the number of rotor blades [3-8].                          3. T o p o l o g i e s for isolated operation of a
                                                                 variable speed wind driven PMSG
2. Permanent Magnet Generator
          Figure 1 shows the cross-section of a typical                    Variable speed use is good for extracting
Permanent Magnet Generator (PMG). The l os s                     more prime mover power as in wind turbine or for
fr e e e x c i t a t i on pr ovi d e d b y p e r m a n en t      providing optimum efficiency for the prime mover by
m a gn e t t h er e for e i n cr e a s e s i n r e l a t i ve    increasing its speed with power. Variable speed also
va l u e a s t h e m a ch i n e si z e i s d e c r e a s e d .   allows for a more flexible generator system. For wind
                                                                 turbines, a battery may be added to store the extra
                                                                 wind energy that is not momentarily needed for the
                                                                 existing loads or local power grids [10-11].
                                                                           At variable speed, the DC link voltage is
                                                                 maintained constant by exchanging power with the
                                                                 storage device, battery as shown in Fig. 2.




Fig.1 Cross-section of typical c onventional
Permanent Magnet Generator
The main features of the permanent magnet
synchronous machine are as follows:
1. Robust, compact and less weight.
2. Copper loss due to the current flow which is the
largest loss in case of induction machine is
approximately half that of induction motor.
3. High efficiency in case of permanent magnet                   Fig.2 PMSG with PWM rectifier with battery for
synchronous machine compared to induction                        storing the extra wind energy
machine.
    The merits of permanent-magnet synchronous                   4. Modeling of proposed system
machines [6-8] over electrically excited machines                4.1. Modeling of System
[14] can be as follows:                                                   This section includes modeling of supply
1. No additional power supply for the magnet                     system (PMSG), load, controller etc. The relevant
field excitation,                                                mathematical analysis is illustrated as follows.
2. No sliding contacts, so it requires less                      4.2. M o d e l i n g of Permanent Magnet Synchronous
maintenance.                                                     Machine.
3. Higher reliability due to the absence                             The permanent magnet synchronous machine
of mechanical components like slip rings.                        block operates in generating or motoring modes. The
4. No field winding, no field copper loss.                       operating mode is dictated by the sign of the
The demerits of PMSM are as follows:                             mechanical power (positive for generating, negative
1. The power factor of operation cannot be controlled            for motoring). The electrical part of the machine is
due to the absence of the field winding,                         represented by a sixth-order state-space model [15].
2. Demagnetization of PM at high temperature.                    The model takes into account the dynamics of the
          In recent years, the use of PMs is more                stator and damper windings.
attractive than before [14], because the performance of                   The equivalent frame (d-q frame) is used for
PMs is improving and the cost of PM is decreasing.               developing the equations for the model of the PMSG.
The permanent magnet synchronous machines can be                 The following equations are used to express the
majorly applied in direct-drive traction motors. Due to

                                                                                                       1901 | P a g e
K. Uday Kumar Reddy, M. Ramasekhara Reddy, Dr. M. Vijaya Kumar / International Journal
    of Engineering Research and Applications (IJERA) ISSN: 2248-9622 www.ijera.com
                   Vol. 2, Issue 5, September- October 2012, pp.1900-1905
model of the PMSG as:                                        4.3. M o d e l i n g of Supply system
      Vd = Rsid + pd – wr q                    (1)                  The supply system consists of three-phase
     Vq = Rsiq + pq + wr d                     (2)         (PMSG) system, diesel engine and governor blocks.
      V‟fd = R‟fdi‟fd + p‟fd                    (3)         The model of Permanent magnet synchronous
    V‟kd = R‟kdi‟kd + p‟kd                        (4)       generator (PMSG) is realized by considering fixed
    V‟kq1 = R‟kq1i‟kq1 + p‟kq1                              excitation of an alternator. The mathematical
                                                   (5)
                                                             representation of all these are given above.
    V‟kq2 = R‟kq2i‟kq2 + p‟kq2                    (6)       4.4. Design of a P, PI & PID controller
    d = Ld id + Lmd ( i‟fd + i‟kd)                (7)                 To change the duty cycle of the converter
    q = Lq iq + Lmq i‟kq                          (8)       the constants involving in P, PI and PID controller
    ‟fd = L‟fd i‟fd + Lmd ( id + i‟kd)            (9)       can be calculated separately by using a suitable trial
    ‟kd = L‟kd i‟kd + Lmd ( id + i‟fd)           (10)       and error technique. The controllers are used for
    ‟kq2 = L‟kq2 i‟kq2 + Lmq iq                  (11)       providing suitable signals for DC-DC buck converter
          Where the subscripts used are defined as: d,       is designed.
q: d and q axis quantity, r, s: Rotor and stator             4.5. Wind Turbine Modeling
quantity, l, m: Leakage and magnetizing inductance,                   This block implements a wind energy
f, k: Field and damper winding quantity. Rs                  conversion system. The inputs are actual and desired
represents stator resistance, Lls           stator leakage   speed and the output of the block is mechanical power
                                                             (Pω) [14]. The amount of power harnessed from the
inductance, Lmd and Lmq                 represent d-axis
                                                             wind of velocity v is as follows.
and q-axis magnetizing inductances. Rf‟ denotes
field resistance and Llfd‟ leakage inductance both                       P=0.5ρAC ν3                     (14)
referred to the stator. Damper d-axis resistance Rkd‟        Where
and leakage inductance Llkd‟, Damper q-axis                          Pω = wind power in watts
resistance Rkq1‟ and leakage inductance Llkq1‟ and
the q-axis resistance Rkq2‟ and leakage Inductance                   ρ = air density in kg/m3
Llkq2‟. All these values are referred to the stator.                  A= swept area in m2
All rotor parameters and electrical quantiti es are                   Cp=power coefficient of wind turbine
viewed fr om the stator and are identified by                         ν= wind speed in m/s
primed variables. The simplified synchronous                 5. Matlab Simulation model of the proposed
machine block implements the mechanical system               topology
described by:                                                         The MATLAB Simulation of proposed
∆w (t) = ∫(Tm – Te) dt / (2H) – Kd∆w (t)         (12)        topology [9] has been shown in the Fig.2. The matlab
w(t) = ∆w (t) + wo                               (13)        Simulink tool box simpower has been used for getting
                                                             `the required results




                                                                                                  1902 | P a g e
K. Uday Kumar Reddy, M. Ramasekhara Reddy, Dr. M. Vijaya Kumar / International Journal
    of Engineering Research and Applications (IJERA) ISSN: 2248-9622 www.ijera.com
                   Vol. 2, Issue 5, September- October 2012, pp.1900-1905
Fig. 3. MATLAB Simulated model of PMSG connected to local Load
6. S i m u l a t i o n Results
          The MATLAB Simulation of proposed
topology has been shown in the Fig.3. The MATLAB
Simulink tool box Simpower System has been used
for getting the required results.
6.1 Performance of PMSG with PWM rectifier with
battery for storing the extra wind energy:
          The wind driven PMSG is run at 300 rpm.
The output voltage is 200 V at 60 hertz. This variable
voltage and variable frequency o u t p u t i s
con ver t ed t o con st an t volta g e an d
constant frequency source. The Fig.4 to 8 shows the
Variation of speed for the wind Turbine, Variation of  Fig.6. Variation of battery power and battery current
load power, generated power, battery power, battery
current & d c-link voltage using P, PI and PID
controllers. The rating of the PMSG is given in the
appendix




                                                           Fig.7. Variation of DC-link voltage using a P-
                                                           controller
                                                                     The change in the level of power varies with
 Fig.4. Variation of Speed for the wind turbine            respect to the change in load demand. The maximum
                                                           power generated at the rotor-side of PMSG is 3200
                                                           watts and later the change in the level of generated
                                                           power varies with respect to the variation in load
                                                           demand at different time instants. The battery energy
                                                           storage mechanism used in the system regulates the
                                                           system from severe imbalances by exchanging the
                                                           energy from generator and the battery. The response
                                                           of dc-link voltage using a proportional-controller is
                                                           shown in fig. 7. In fig. 7 though the peak –overshoot
                                                           is less but the output oscillates around 200 volts.




 Fig.5. Variation of Generated power and Load side
power
         The load perbutations are made to occur at
t=0.5 sec and there is a sudden increase in the level of
load side current to 3 amps which draws more current
from the generator. After certain period, t=1 sec the
current in the load side again reaches to 2 amps. The
sudden increase in the current implies that the more
current is drawn from the generator and the system
balance is obtained by suitable battery energy storage
systems.                                                     Fig.8. Variation of DC-link voltage using a PI
                                                           controller




                                                                                                1903 | P a g e
K. Uday Kumar Reddy, M. Ramasekhara Reddy, Dr. M. Vijaya Kumar / International Journal
    of Engineering Research and Applications (IJERA) ISSN: 2248-9622 www.ijera.com
                   Vol. 2, Issue 5, September- October 2012, pp.1900-1905
                                                          [3]    Ghosh and G. Ledwich, Power Quality
                                                                 Enhancement Using Custom Power
                                                                 Devices. Kulwer Academic, 2002.
                                                          [4]    Gipe, P. Wind power‟, Chelsea Green
                                                                 Publishing Company, Post Mills, Vermount,
                                                                 USA,1995.
                                                          [5]    Rai, G.D. (2000) „Non conventional energy
                                                                 sources‟, Khanna Publishers, 4th Edition,
                                                                 New Delhi (India)
                                                          [6]    Bansal, R.C., Bhatti, T.S., and Kothari, D.P.
                                                                 „On some of the design aspects of wind
                                                                 energy conversion systems”, Int. Journal of
                                                                 Energy Conversion and Management, Nov.
Fig.9. Variation of DC-link voltage using a PID                  Vol. 43, No. 16, pp. 2175- 2187,2002.
controller                                                [7]    Singh,      B.      „Induction     generator-a
         The PI-controller offsets or eliminates the             prospective‟, Electric Machines and Power
steady state oscillations that are occurred using a              Systems, Vol. 23, pp. 163-177, 1995.
proportional-controller and the system stability is       [8]    Zouaghi, “Variable Speed Drive modeling
improved as shown in fig.8. In fig.9, the output                 of Wind Turbine Permanent Magnet
voltage using PID controller got changed by reducing             Synchronous        Generator,”      ICREP‟04
the peak-overshoot & the time of response got                    International Conference on Renewable
decreased to a certain extent. Hence for economical              Energy and Power Quality, Barcelona,
savings; PID controller serves better purpose apart              Spain, 2004.
from the other controllers proposed in this design. So,   [9]    C. Ong "Dynamic Simulation of Electric
PID controller serves the efficient choice for the               Machines Using MATLAB/Simulink"
selection of the controller.                                     Editorial "Prentice Hall", 1998.
                                                          [10]   D.C. Aliprantis, S.A. Papathanassiou, M.P.
7. Conclusion
           In the proposed scheme, battery energy                Papadopoulos, A.G. Kaladas, “Modeling
storage system provides power balance between the                and control of a variable-speed wind turbine
generated power and the load. The power mismatch is              equipped       with     permanent      magnet
absorbed by the BESS. From the obtained results it is            synchronous generator,” Proc. Of ICEM,
                                                                 Vol.3, pp.558-562, 2000.
clearly observed that the oscillations free output can
                                                          [11]   Mukhtiar Singh, A. Chandra,“ Power
be obtained by using a PID-controller and PID-
                                                                 Maximization and Voltage Sag/Swell Ride-
controller improves the stability of the system and
                                                                 Through Capability of PMSG based
hence is the best choice for the selection of the
                                                                 Variable Speed Wind Energy Conversion
controller.
                                                                 System” in proc. of 34Th Annual conf. of
                   APPENDIX
                                                                 IEEE       Indus.      Electronics    Society,
Permanent Magnet Synchronous Generator:
                                                                 IECON‟08, Orlando, Florida, USA ,2008.
3-Phase, 300 V, 60 Hz, 3000 rpm, 4-pole
                                                          [12]   C. Jauch, J. Matevosyan, T. Ackermann and
Electromagnetic Torque             : 0.8 Nm
                                                                 S. Bolik. 2005. International comparison of
Stator Resistance (RS)             : 18.7 Ω
                                                                 requirements for connection of wind
Inductance: Ld (H) = Lq(H)         : 0.02682 H
                                                                 turbines to power systems. Wind Energy. 8:
Flux induced by magnets            : 0.1717 Wb.
                                                                 295-306.
References                                                [13]   C. Jauch, P. Sorensen and B. Bak-Jensen.
  [1]    R. Mittal, Sandhu, Jain, “Battery energy                2004. International review of grid
         storage system for a wind driven variable-              connection requirements for wind turbines.
         speed permanent magnet synchronous                      In: Nordic wind power conference.
         generator for wind energy conversion                    Goteborg, March.
         system”,     International  Journal     of       [14]   S.N. Bhadra, S. Banerjee, D. Kastha
         Innovation, Management and Technology,                  (2005),„Wind electrical systems,„ Oxford
         Vol. 1, No. 3, August 2010, ISSN: 2010-                 University Press, 2005, ISBN : 0195670936
         248                                              [15]   Bhim Singh and Gaurav Kumar Kasal,
  [2]    Bhim Singh and Gaurav Kumar Kasal,                      “Solid-State Voltage and Frequency
         “Voltage and Frequency Controller for a 3-              Controller for a stand-alone wind power
         Phase 4-Wire Autonomous Wind Energy                     generating system,” IEEE Trans. Power
         Conversion      System”    accepted     for             Electronics, vol. 23, no.3, pp.1170–1177,
         publication in IEEE Trans. on Energy                    2008.
         Conversion.



                                                                                              1904 | P a g e

More Related Content

What's hot

14 9737 lightning paper id 0005 edit septian
14 9737 lightning paper id 0005 edit septian14 9737 lightning paper id 0005 edit septian
14 9737 lightning paper id 0005 edit septianIAESIJEECS
 
High Proficiency Grid ConnectedPhotovoltaic Power Generation System
High Proficiency Grid ConnectedPhotovoltaic Power Generation SystemHigh Proficiency Grid ConnectedPhotovoltaic Power Generation System
High Proficiency Grid ConnectedPhotovoltaic Power Generation SystemIJRES Journal
 
PV Hybrid System with DSTATCOM for Residential Applications
PV Hybrid System with DSTATCOM for Residential ApplicationsPV Hybrid System with DSTATCOM for Residential Applications
PV Hybrid System with DSTATCOM for Residential ApplicationsIDES Editor
 
Isolated Wind Hydro Hybrid Generation System with Battery Storage
Isolated Wind Hydro Hybrid Generation System with Battery StorageIsolated Wind Hydro Hybrid Generation System with Battery Storage
Isolated Wind Hydro Hybrid Generation System with Battery StorageIJMER
 
Performance of Photovoltaic Assisted Five Level Diode Clamped Inverter fed In...
Performance of Photovoltaic Assisted Five Level Diode Clamped Inverter fed In...Performance of Photovoltaic Assisted Five Level Diode Clamped Inverter fed In...
Performance of Photovoltaic Assisted Five Level Diode Clamped Inverter fed In...IJMTST Journal
 
A Three Phase Multi Level Converter for grid Connected PV System
A Three Phase Multi Level Converter for grid Connected PV SystemA Three Phase Multi Level Converter for grid Connected PV System
A Three Phase Multi Level Converter for grid Connected PV SystemIAES-IJPEDS
 
Power Quality Improvement with Multilevel Inverter Based IPQC for Microgrid
Power Quality Improvement with Multilevel Inverter Based IPQC for MicrogridPower Quality Improvement with Multilevel Inverter Based IPQC for Microgrid
Power Quality Improvement with Multilevel Inverter Based IPQC for MicrogridIJMTST Journal
 
Interleaved Boost Converter Fed with PV for Induction Motor/Agricultural Appl...
Interleaved Boost Converter Fed with PV for Induction Motor/Agricultural Appl...Interleaved Boost Converter Fed with PV for Induction Motor/Agricultural Appl...
Interleaved Boost Converter Fed with PV for Induction Motor/Agricultural Appl...IAES-IJPEDS
 
Modeling and Simulation of an electrical micro-grid using MATLAB Simulink Sum...
Modeling and Simulation of an electrical micro-grid using MATLAB Simulink Sum...Modeling and Simulation of an electrical micro-grid using MATLAB Simulink Sum...
Modeling and Simulation of an electrical micro-grid using MATLAB Simulink Sum...Aodhgan Gleeson
 
SIMULATION OF IMPROVEMENT OF POWER QUALITY USING STATCOM-CONTROL SCHEME WITH ...
SIMULATION OF IMPROVEMENT OF POWER QUALITY USING STATCOM-CONTROL SCHEME WITH ...SIMULATION OF IMPROVEMENT OF POWER QUALITY USING STATCOM-CONTROL SCHEME WITH ...
SIMULATION OF IMPROVEMENT OF POWER QUALITY USING STATCOM-CONTROL SCHEME WITH ...ijiert bestjournal
 
Grid Connected Distributed Generation System with High Voltage Gain Cascaded ...
Grid Connected Distributed Generation System with High Voltage Gain Cascaded ...Grid Connected Distributed Generation System with High Voltage Gain Cascaded ...
Grid Connected Distributed Generation System with High Voltage Gain Cascaded ...IJECEIAES
 
Frequency control in a microgrid including controllable load
Frequency control in a microgrid including controllable loadFrequency control in a microgrid including controllable load
Frequency control in a microgrid including controllable loadIAEME Publication
 
Fixed Output DC to DC Converter for Photovoltaic System
Fixed Output DC to DC Converter for Photovoltaic SystemFixed Output DC to DC Converter for Photovoltaic System
Fixed Output DC to DC Converter for Photovoltaic Systemijtsrd
 
A New Simulation Approach of 3-Φ Transformer-less Grid Connected PV Inverter ...
A New Simulation Approach of 3-Φ Transformer-less Grid Connected PV Inverter ...A New Simulation Approach of 3-Φ Transformer-less Grid Connected PV Inverter ...
A New Simulation Approach of 3-Φ Transformer-less Grid Connected PV Inverter ...IRJET Journal
 
Measurement and Analysis of Power in Hybrid System
Measurement and Analysis of Power in Hybrid SystemMeasurement and Analysis of Power in Hybrid System
Measurement and Analysis of Power in Hybrid Systemijeei-iaes
 
Grid Connected Applications of Modular Cascaded H-Bridge Multilevel PV Invert...
Grid Connected Applications of Modular Cascaded H-Bridge Multilevel PV Invert...Grid Connected Applications of Modular Cascaded H-Bridge Multilevel PV Invert...
Grid Connected Applications of Modular Cascaded H-Bridge Multilevel PV Invert...IRJET Journal
 
IRJET- Impact of UPQC on Protection of Distributed Generation Integrated Dist...
IRJET- Impact of UPQC on Protection of Distributed Generation Integrated Dist...IRJET- Impact of UPQC on Protection of Distributed Generation Integrated Dist...
IRJET- Impact of UPQC on Protection of Distributed Generation Integrated Dist...IRJET Journal
 

What's hot (20)

14 9737 lightning paper id 0005 edit septian
14 9737 lightning paper id 0005 edit septian14 9737 lightning paper id 0005 edit septian
14 9737 lightning paper id 0005 edit septian
 
High Proficiency Grid ConnectedPhotovoltaic Power Generation System
High Proficiency Grid ConnectedPhotovoltaic Power Generation SystemHigh Proficiency Grid ConnectedPhotovoltaic Power Generation System
High Proficiency Grid ConnectedPhotovoltaic Power Generation System
 
PV Hybrid System with DSTATCOM for Residential Applications
PV Hybrid System with DSTATCOM for Residential ApplicationsPV Hybrid System with DSTATCOM for Residential Applications
PV Hybrid System with DSTATCOM for Residential Applications
 
Isolated Wind Hydro Hybrid Generation System with Battery Storage
Isolated Wind Hydro Hybrid Generation System with Battery StorageIsolated Wind Hydro Hybrid Generation System with Battery Storage
Isolated Wind Hydro Hybrid Generation System with Battery Storage
 
Performance of Photovoltaic Assisted Five Level Diode Clamped Inverter fed In...
Performance of Photovoltaic Assisted Five Level Diode Clamped Inverter fed In...Performance of Photovoltaic Assisted Five Level Diode Clamped Inverter fed In...
Performance of Photovoltaic Assisted Five Level Diode Clamped Inverter fed In...
 
A Three Phase Multi Level Converter for grid Connected PV System
A Three Phase Multi Level Converter for grid Connected PV SystemA Three Phase Multi Level Converter for grid Connected PV System
A Three Phase Multi Level Converter for grid Connected PV System
 
Power Quality Improvement with Multilevel Inverter Based IPQC for Microgrid
Power Quality Improvement with Multilevel Inverter Based IPQC for MicrogridPower Quality Improvement with Multilevel Inverter Based IPQC for Microgrid
Power Quality Improvement with Multilevel Inverter Based IPQC for Microgrid
 
Interleaved Boost Converter Fed with PV for Induction Motor/Agricultural Appl...
Interleaved Boost Converter Fed with PV for Induction Motor/Agricultural Appl...Interleaved Boost Converter Fed with PV for Induction Motor/Agricultural Appl...
Interleaved Boost Converter Fed with PV for Induction Motor/Agricultural Appl...
 
Modeling and Simulation of an electrical micro-grid using MATLAB Simulink Sum...
Modeling and Simulation of an electrical micro-grid using MATLAB Simulink Sum...Modeling and Simulation of an electrical micro-grid using MATLAB Simulink Sum...
Modeling and Simulation of an electrical micro-grid using MATLAB Simulink Sum...
 
D03701028034
D03701028034D03701028034
D03701028034
 
40620130101002
4062013010100240620130101002
40620130101002
 
SIMULATION OF IMPROVEMENT OF POWER QUALITY USING STATCOM-CONTROL SCHEME WITH ...
SIMULATION OF IMPROVEMENT OF POWER QUALITY USING STATCOM-CONTROL SCHEME WITH ...SIMULATION OF IMPROVEMENT OF POWER QUALITY USING STATCOM-CONTROL SCHEME WITH ...
SIMULATION OF IMPROVEMENT OF POWER QUALITY USING STATCOM-CONTROL SCHEME WITH ...
 
Performance analysis of hybrid photovoltaic/wind energy system using KY boost...
Performance analysis of hybrid photovoltaic/wind energy system using KY boost...Performance analysis of hybrid photovoltaic/wind energy system using KY boost...
Performance analysis of hybrid photovoltaic/wind energy system using KY boost...
 
Grid Connected Distributed Generation System with High Voltage Gain Cascaded ...
Grid Connected Distributed Generation System with High Voltage Gain Cascaded ...Grid Connected Distributed Generation System with High Voltage Gain Cascaded ...
Grid Connected Distributed Generation System with High Voltage Gain Cascaded ...
 
Frequency control in a microgrid including controllable load
Frequency control in a microgrid including controllable loadFrequency control in a microgrid including controllable load
Frequency control in a microgrid including controllable load
 
Fixed Output DC to DC Converter for Photovoltaic System
Fixed Output DC to DC Converter for Photovoltaic SystemFixed Output DC to DC Converter for Photovoltaic System
Fixed Output DC to DC Converter for Photovoltaic System
 
A New Simulation Approach of 3-Φ Transformer-less Grid Connected PV Inverter ...
A New Simulation Approach of 3-Φ Transformer-less Grid Connected PV Inverter ...A New Simulation Approach of 3-Φ Transformer-less Grid Connected PV Inverter ...
A New Simulation Approach of 3-Φ Transformer-less Grid Connected PV Inverter ...
 
Measurement and Analysis of Power in Hybrid System
Measurement and Analysis of Power in Hybrid SystemMeasurement and Analysis of Power in Hybrid System
Measurement and Analysis of Power in Hybrid System
 
Grid Connected Applications of Modular Cascaded H-Bridge Multilevel PV Invert...
Grid Connected Applications of Modular Cascaded H-Bridge Multilevel PV Invert...Grid Connected Applications of Modular Cascaded H-Bridge Multilevel PV Invert...
Grid Connected Applications of Modular Cascaded H-Bridge Multilevel PV Invert...
 
IRJET- Impact of UPQC on Protection of Distributed Generation Integrated Dist...
IRJET- Impact of UPQC on Protection of Distributed Generation Integrated Dist...IRJET- Impact of UPQC on Protection of Distributed Generation Integrated Dist...
IRJET- Impact of UPQC on Protection of Distributed Generation Integrated Dist...
 

Viewers also liked

Evaluation of Euclidean and Manhanttan Metrics In Content Based Image Retriev...
Evaluation of Euclidean and Manhanttan Metrics In Content Based Image Retriev...Evaluation of Euclidean and Manhanttan Metrics In Content Based Image Retriev...
Evaluation of Euclidean and Manhanttan Metrics In Content Based Image Retriev...IJERA Editor
 
Study and Analysis of Six Stroke Engine
Study and Analysis of Six Stroke EngineStudy and Analysis of Six Stroke Engine
Study and Analysis of Six Stroke EngineIJERA Editor
 
Arm Robot Surveillance Using Dual Tone Multiple Frequency Technology
Arm Robot Surveillance Using Dual Tone Multiple Frequency TechnologyArm Robot Surveillance Using Dual Tone Multiple Frequency Technology
Arm Robot Surveillance Using Dual Tone Multiple Frequency TechnologyIJERA Editor
 
Proyecto integracion y empleo
Proyecto integracion y empleoProyecto integracion y empleo
Proyecto integracion y empleoinaenaito
 
Algundia
AlgundiaAlgundia
Algundiamamen46
 
Aje Castellón- Proyecto Social Media 2011
Aje Castellón- Proyecto Social Media 2011Aje Castellón- Proyecto Social Media 2011
Aje Castellón- Proyecto Social Media 2011Soluciona Facil
 
As sete maravilhas do mundo
As sete maravilhas do mundoAs sete maravilhas do mundo
As sete maravilhas do mundoalanalins71
 
Arcos De Jalon
Arcos De JalonArcos De Jalon
Arcos De Jaloninaenaito
 

Viewers also liked (20)

Lh2519601962
Lh2519601962Lh2519601962
Lh2519601962
 
Kp2518561863
Kp2518561863Kp2518561863
Kp2518561863
 
Kt2518841887
Kt2518841887Kt2518841887
Kt2518841887
 
Evaluation of Euclidean and Manhanttan Metrics In Content Based Image Retriev...
Evaluation of Euclidean and Manhanttan Metrics In Content Based Image Retriev...Evaluation of Euclidean and Manhanttan Metrics In Content Based Image Retriev...
Evaluation of Euclidean and Manhanttan Metrics In Content Based Image Retriev...
 
Study and Analysis of Six Stroke Engine
Study and Analysis of Six Stroke EngineStudy and Analysis of Six Stroke Engine
Study and Analysis of Six Stroke Engine
 
Arm Robot Surveillance Using Dual Tone Multiple Frequency Technology
Arm Robot Surveillance Using Dual Tone Multiple Frequency TechnologyArm Robot Surveillance Using Dual Tone Multiple Frequency Technology
Arm Robot Surveillance Using Dual Tone Multiple Frequency Technology
 
Dj31747750
Dj31747750Dj31747750
Dj31747750
 
Ft3111351140
Ft3111351140Ft3111351140
Ft3111351140
 
A045040110
A045040110A045040110
A045040110
 
A045050107
A045050107A045050107
A045050107
 
Proyecto integracion y empleo
Proyecto integracion y empleoProyecto integracion y empleo
Proyecto integracion y empleo
 
Aguilas
AguilasAguilas
Aguilas
 
Algundia
AlgundiaAlgundia
Algundia
 
06 colisao final
06 colisao final06 colisao final
06 colisao final
 
El pla
El plaEl pla
El pla
 
Aje Castellón- Proyecto Social Media 2011
Aje Castellón- Proyecto Social Media 2011Aje Castellón- Proyecto Social Media 2011
Aje Castellón- Proyecto Social Media 2011
 
As sete maravilhas do mundo
As sete maravilhas do mundoAs sete maravilhas do mundo
As sete maravilhas do mundo
 
Arcos De Jalon
Arcos De JalonArcos De Jalon
Arcos De Jalon
 
Mostafa Kamal
Mostafa KamalMostafa Kamal
Mostafa Kamal
 
Tras Cámara Reflejo de la Urbe
Tras Cámara Reflejo de la UrbeTras Cámara Reflejo de la Urbe
Tras Cámara Reflejo de la Urbe
 

Similar to Kw2519001905

IRJET- Improvement of Wind Turbine DFIG using Fault Ride Through Capability T...
IRJET- Improvement of Wind Turbine DFIG using Fault Ride Through Capability T...IRJET- Improvement of Wind Turbine DFIG using Fault Ride Through Capability T...
IRJET- Improvement of Wind Turbine DFIG using Fault Ride Through Capability T...IRJET Journal
 
Mitigation of Voltage Dip and Swell Faults in Wind Energy Conversion Systems
Mitigation of Voltage Dip and Swell Faults in Wind Energy Conversion SystemsMitigation of Voltage Dip and Swell Faults in Wind Energy Conversion Systems
Mitigation of Voltage Dip and Swell Faults in Wind Energy Conversion SystemsIRJET Journal
 
Power Loss Minimization of Permanent Magnet Synchronous Generator Using Part...
Power Loss Minimization of Permanent Magnet Synchronous Generator  Using Part...Power Loss Minimization of Permanent Magnet Synchronous Generator  Using Part...
Power Loss Minimization of Permanent Magnet Synchronous Generator Using Part...IJMER
 
A PFC Fed Asynchronous Generator For Advanced Wind Power Generation Excited B...
A PFC Fed Asynchronous Generator For Advanced Wind Power Generation Excited B...A PFC Fed Asynchronous Generator For Advanced Wind Power Generation Excited B...
A PFC Fed Asynchronous Generator For Advanced Wind Power Generation Excited B...IOSR Journals
 
dfigppt-221029141308-fdd782dd.pptx
dfigppt-221029141308-fdd782dd.pptxdfigppt-221029141308-fdd782dd.pptx
dfigppt-221029141308-fdd782dd.pptxSudeepgowda16
 
Stability check of doubly fed induction generator (DFIG) micro grid power system
Stability check of doubly fed induction generator (DFIG) micro grid power systemStability check of doubly fed induction generator (DFIG) micro grid power system
Stability check of doubly fed induction generator (DFIG) micro grid power systemjournalBEEI
 
Grid Connected Doubly Fed Induction Generator By Wind Power Application
Grid Connected Doubly Fed Induction Generator By Wind Power ApplicationGrid Connected Doubly Fed Induction Generator By Wind Power Application
Grid Connected Doubly Fed Induction Generator By Wind Power ApplicationIRJET Journal
 
IRJET- Application of Small Wind Turbine in Small Grid using Permanent Magnet...
IRJET- Application of Small Wind Turbine in Small Grid using Permanent Magnet...IRJET- Application of Small Wind Turbine in Small Grid using Permanent Magnet...
IRJET- Application of Small Wind Turbine in Small Grid using Permanent Magnet...IRJET Journal
 
Full-scale converter for synchronous wind turbine generators
Full-scale converter for synchronous wind turbine generatorsFull-scale converter for synchronous wind turbine generators
Full-scale converter for synchronous wind turbine generatorsLong Thang Pham
 
Stabilization and Frequency Regulation in Microgrid by Controlling Pitch Angle
Stabilization and Frequency Regulation in Microgrid by Controlling Pitch AngleStabilization and Frequency Regulation in Microgrid by Controlling Pitch Angle
Stabilization and Frequency Regulation in Microgrid by Controlling Pitch Angleijtsrd
 
POWER QUALITY IMPROVEMENT METHODOLOGY IN MICROGRID: A REVIEW
POWER QUALITY IMPROVEMENT METHODOLOGY IN MICROGRID: A REVIEWPOWER QUALITY IMPROVEMENT METHODOLOGY IN MICROGRID: A REVIEW
POWER QUALITY IMPROVEMENT METHODOLOGY IN MICROGRID: A REVIEWIRJET Journal
 
Review Grid Connected Wind Photovoltaic Cogeneration Using Back to Back Volta...
Review Grid Connected Wind Photovoltaic Cogeneration Using Back to Back Volta...Review Grid Connected Wind Photovoltaic Cogeneration Using Back to Back Volta...
Review Grid Connected Wind Photovoltaic Cogeneration Using Back to Back Volta...IJSRED
 
Open-End-Winding Permanent Magnet Synchonous Generator for Wind Energy Conver...
Open-End-Winding Permanent Magnet Synchonous Generator for Wind Energy Conver...Open-End-Winding Permanent Magnet Synchonous Generator for Wind Energy Conver...
Open-End-Winding Permanent Magnet Synchonous Generator for Wind Energy Conver...Naila Syed
 

Similar to Kw2519001905 (20)

IRJET- Improvement of Wind Turbine DFIG using Fault Ride Through Capability T...
IRJET- Improvement of Wind Turbine DFIG using Fault Ride Through Capability T...IRJET- Improvement of Wind Turbine DFIG using Fault Ride Through Capability T...
IRJET- Improvement of Wind Turbine DFIG using Fault Ride Through Capability T...
 
Mitigation of Voltage Dip and Swell Faults in Wind Energy Conversion Systems
Mitigation of Voltage Dip and Swell Faults in Wind Energy Conversion SystemsMitigation of Voltage Dip and Swell Faults in Wind Energy Conversion Systems
Mitigation of Voltage Dip and Swell Faults in Wind Energy Conversion Systems
 
Cl24579584
Cl24579584Cl24579584
Cl24579584
 
Power Loss Minimization of Permanent Magnet Synchronous Generator Using Part...
Power Loss Minimization of Permanent Magnet Synchronous Generator  Using Part...Power Loss Minimization of Permanent Magnet Synchronous Generator  Using Part...
Power Loss Minimization of Permanent Magnet Synchronous Generator Using Part...
 
windppt.pptx
windppt.pptxwindppt.pptx
windppt.pptx
 
A PFC Fed Asynchronous Generator For Advanced Wind Power Generation Excited B...
A PFC Fed Asynchronous Generator For Advanced Wind Power Generation Excited B...A PFC Fed Asynchronous Generator For Advanced Wind Power Generation Excited B...
A PFC Fed Asynchronous Generator For Advanced Wind Power Generation Excited B...
 
dfigppt-221029141308-fdd782dd.pptx
dfigppt-221029141308-fdd782dd.pptxdfigppt-221029141308-fdd782dd.pptx
dfigppt-221029141308-fdd782dd.pptx
 
Wind generators
Wind generatorsWind generators
Wind generators
 
Stability check of doubly fed induction generator (DFIG) micro grid power system
Stability check of doubly fed induction generator (DFIG) micro grid power systemStability check of doubly fed induction generator (DFIG) micro grid power system
Stability check of doubly fed induction generator (DFIG) micro grid power system
 
Fl3610001006
Fl3610001006Fl3610001006
Fl3610001006
 
Grid Connected Doubly Fed Induction Generator By Wind Power Application
Grid Connected Doubly Fed Induction Generator By Wind Power ApplicationGrid Connected Doubly Fed Induction Generator By Wind Power Application
Grid Connected Doubly Fed Induction Generator By Wind Power Application
 
IRJET- Application of Small Wind Turbine in Small Grid using Permanent Magnet...
IRJET- Application of Small Wind Turbine in Small Grid using Permanent Magnet...IRJET- Application of Small Wind Turbine in Small Grid using Permanent Magnet...
IRJET- Application of Small Wind Turbine in Small Grid using Permanent Magnet...
 
Cy36602610
Cy36602610Cy36602610
Cy36602610
 
Full-scale converter for synchronous wind turbine generators
Full-scale converter for synchronous wind turbine generatorsFull-scale converter for synchronous wind turbine generators
Full-scale converter for synchronous wind turbine generators
 
Stabilization and Frequency Regulation in Microgrid by Controlling Pitch Angle
Stabilization and Frequency Regulation in Microgrid by Controlling Pitch AngleStabilization and Frequency Regulation in Microgrid by Controlling Pitch Angle
Stabilization and Frequency Regulation in Microgrid by Controlling Pitch Angle
 
POWER QUALITY IMPROVEMENT METHODOLOGY IN MICROGRID: A REVIEW
POWER QUALITY IMPROVEMENT METHODOLOGY IN MICROGRID: A REVIEWPOWER QUALITY IMPROVEMENT METHODOLOGY IN MICROGRID: A REVIEW
POWER QUALITY IMPROVEMENT METHODOLOGY IN MICROGRID: A REVIEW
 
DFIG ppt.pptx
DFIG ppt.pptxDFIG ppt.pptx
DFIG ppt.pptx
 
Review Grid Connected Wind Photovoltaic Cogeneration Using Back to Back Volta...
Review Grid Connected Wind Photovoltaic Cogeneration Using Back to Back Volta...Review Grid Connected Wind Photovoltaic Cogeneration Using Back to Back Volta...
Review Grid Connected Wind Photovoltaic Cogeneration Using Back to Back Volta...
 
Open-End-Winding Permanent Magnet Synchonous Generator for Wind Energy Conver...
Open-End-Winding Permanent Magnet Synchonous Generator for Wind Energy Conver...Open-End-Winding Permanent Magnet Synchonous Generator for Wind Energy Conver...
Open-End-Winding Permanent Magnet Synchonous Generator for Wind Energy Conver...
 
K010516873
K010516873K010516873
K010516873
 

Kw2519001905

  • 1. K. Uday Kumar Reddy, M. Ramasekhara Reddy, Dr. M. Vijaya Kumar / International Journal of Engineering Research and Applications (IJERA) ISSN: 2248-9622 www.ijera.com Vol. 2, Issue 5, September- October 2012, pp.1900-1905 Modeling and Control of a Permanent Magnet Synchronous Generator Wind Turbine with Energy Storage K. Uday Kumar Reddy1, M. Ramasekhara Reddy 2, Dr. M. Vijaya Kumar3 1 (M. Tech, Department of Electrical & Electronics Engg, JNTUACE, Pulivendula, A.P, India.) 2 (Assistant Professor, Department of Electrical & Electronics Engg, JNTUACE, Pulivendula, A.P, India.) 3 ( Professor, Department of Electrical & Electronics Engg, JNTUACE, Anantapur, A.P, India.) ABSTRACT Wind energy is an important renewable approach to self-sufficient power generation involves source which is used for power generation for a using a wind-turbine with a storage mechanism to stand-alone as well as grid connected applications. create a stand-alone system. If wind conditions are In many remote areas, loads are usually connected favorable, these stand-alone wind energy systems away from the grid. In such cases, isolated wind usually can provide communities with electricity at energy systems can be considered as an effective the lowest cost. Stand-alone wind energy systems way to provide continuous power to electrical often include batteries, because the available wind loads. The power conversion unit features a wi nd- does not always produce the required quantities of turbine-driven PMSG, a d i o d e rectifier, a power. If wind power exceeds the load demand, the b u c k converter, a battery bank, a feed-back surplus energy can be stored in storage systems like controller, and a dc/ac inverter. In this paper, an batteries [1-3]. Multiple types of generators are being isolated wind energy conversion system is used with wind turbines. Small wind turbines are implemented using a variable speed permanent equipped with DC generators of up to a fractional magnet synchronous generator (PMSG) with kilowatt in capacity [6]. The major types of AC PWM rectifier and a battery for storing the excess generators that are possible candidates in wind amount of wind energy. To change the duty cycle turbine systems are as follows: of the converter, a controller of DC-DC buck • Squirrel-Cage rotor Induction Generator (SCIG), converter with MOSFET as a switching • Wound-Rotor Induction Generator (WRIG), component is designed using P, PI and PID • Doubly-Fed Induction Generator (DFIG) controller to provide the efficient choice for the • Synchronous Generator (With external field selection of the controller. The proposed scheme is excitation), implemented in MATLAB using Simulink & the •Permanent Magnet Synchronous Generator (PMSG). simulation results show that the output voltage of An induction generator (IG) has been the converter can be controlled according to the extensively used in commercial wind turbine units. value of duty cycle and the excess power is stored Asynchronous operation of induction generators is in battery to provide balance between the considered an advantage for application in wind generator and the load. turbine systems, because it provides some degree of flexibility when the wind speed is fluctuating or Keywords: Wind e n e r g y conversion variable [5-6]. The induction generator based on s y s t e m , battery bank, Permanent magnet Squirrel-Cage rotor (SCIG) is a very popular machine synchronous generator, isolated system. because of its low cost, mechanical simplicity, robust structure, and resistance against disturbance 1. Introduction and vibration. The induction generator based on Renewable sources of energy mainly wound rotor is the doubly fed induction generator including wind power offer a feasible solution to (DFIG), which is a kind of induction machine in distributed power generation for isolated which both the stator windings and the rotor communities where grids are unavailable. At present windings are connected to the source [7-8]. scenario wind power has emerged as the most viable Another type of generator that has been source of electric power is economically competitive proposed for wind turbines in several research articles with the non-renewable sources of energy. In such is synchronous generator. This type of generator has cases, isolated wind energy systems can be the capability of direct connection (direct-drive) to considered as an effective way to provide continuous wind turbines, with no gearbox [12]. This advantage power to electrical loads. One of the most promising is favorable with respect to lifetime and maintenance. applications of renewable energy generation lies in Synchronous machines can use either the development of power supply systems for remote electrically excited or permanent magnet (PM) rotor. villages that lack an economically feasible means of The PM and electrically-excited synchronous connecting to the main electrical grid. For the type of generators differ from the induction generator in that loads located far from a utility grid, one practical the magnetization is provided by a Permanent 1900 | P a g e
  • 2. K. Uday Kumar Reddy, M. Ramasekhara Reddy, Dr. M. Vijaya Kumar / International Journal of Engineering Research and Applications (IJERA) ISSN: 2248-9622 www.ijera.com Vol. 2, Issue 5, September- October 2012, pp.1900-1905 Magnet pole system or a dc supply on the rotor, the natural laws of electromagnetic scaling, there is an featuring providing self-excitation property. Self- excitation penalty involved in small PM machines. excitation allows operation at high power factors and As the geometrical size is decreased, the high efficiencies for the PMSG [13]. A comparison cross-sectional area available for copper conductor between the variable speed wind turbine and the decreases with the square of the linear dimensions. constant speed wind turbine shows that variable The need for the magneto-motive force decreases with speed reduce mechanical stresses, gusts of wind can the linear dimension, being primarily determined by be absorbed, dynamically compensate for torque and the length of the air-gap [14]. During the high power pulsations caused by back pressure of the temperatures, the current may be sufficient enough to tower. This backpressure causes noticeable torque demagnetize the magnets providing excitation. pulsations at a rate equal to the turbine rotor speed times the number of rotor blades [3-8]. 3. T o p o l o g i e s for isolated operation of a variable speed wind driven PMSG 2. Permanent Magnet Generator Figure 1 shows the cross-section of a typical Variable speed use is good for extracting Permanent Magnet Generator (PMG). The l os s more prime mover power as in wind turbine or for fr e e e x c i t a t i on pr ovi d e d b y p e r m a n en t providing optimum efficiency for the prime mover by m a gn e t t h er e for e i n cr e a s e s i n r e l a t i ve increasing its speed with power. Variable speed also va l u e a s t h e m a ch i n e si z e i s d e c r e a s e d . allows for a more flexible generator system. For wind turbines, a battery may be added to store the extra wind energy that is not momentarily needed for the existing loads or local power grids [10-11]. At variable speed, the DC link voltage is maintained constant by exchanging power with the storage device, battery as shown in Fig. 2. Fig.1 Cross-section of typical c onventional Permanent Magnet Generator The main features of the permanent magnet synchronous machine are as follows: 1. Robust, compact and less weight. 2. Copper loss due to the current flow which is the largest loss in case of induction machine is approximately half that of induction motor. 3. High efficiency in case of permanent magnet Fig.2 PMSG with PWM rectifier with battery for synchronous machine compared to induction storing the extra wind energy machine. The merits of permanent-magnet synchronous 4. Modeling of proposed system machines [6-8] over electrically excited machines 4.1. Modeling of System [14] can be as follows: This section includes modeling of supply 1. No additional power supply for the magnet system (PMSG), load, controller etc. The relevant field excitation, mathematical analysis is illustrated as follows. 2. No sliding contacts, so it requires less 4.2. M o d e l i n g of Permanent Magnet Synchronous maintenance. Machine. 3. Higher reliability due to the absence The permanent magnet synchronous machine of mechanical components like slip rings. block operates in generating or motoring modes. The 4. No field winding, no field copper loss. operating mode is dictated by the sign of the The demerits of PMSM are as follows: mechanical power (positive for generating, negative 1. The power factor of operation cannot be controlled for motoring). The electrical part of the machine is due to the absence of the field winding, represented by a sixth-order state-space model [15]. 2. Demagnetization of PM at high temperature. The model takes into account the dynamics of the In recent years, the use of PMs is more stator and damper windings. attractive than before [14], because the performance of The equivalent frame (d-q frame) is used for PMs is improving and the cost of PM is decreasing. developing the equations for the model of the PMSG. The permanent magnet synchronous machines can be The following equations are used to express the majorly applied in direct-drive traction motors. Due to 1901 | P a g e
  • 3. K. Uday Kumar Reddy, M. Ramasekhara Reddy, Dr. M. Vijaya Kumar / International Journal of Engineering Research and Applications (IJERA) ISSN: 2248-9622 www.ijera.com Vol. 2, Issue 5, September- October 2012, pp.1900-1905 model of the PMSG as: 4.3. M o d e l i n g of Supply system Vd = Rsid + pd – wr q (1) The supply system consists of three-phase Vq = Rsiq + pq + wr d (2) (PMSG) system, diesel engine and governor blocks. V‟fd = R‟fdi‟fd + p‟fd (3) The model of Permanent magnet synchronous V‟kd = R‟kdi‟kd + p‟kd (4) generator (PMSG) is realized by considering fixed V‟kq1 = R‟kq1i‟kq1 + p‟kq1 excitation of an alternator. The mathematical (5) representation of all these are given above. V‟kq2 = R‟kq2i‟kq2 + p‟kq2 (6) 4.4. Design of a P, PI & PID controller d = Ld id + Lmd ( i‟fd + i‟kd) (7) To change the duty cycle of the converter q = Lq iq + Lmq i‟kq (8) the constants involving in P, PI and PID controller ‟fd = L‟fd i‟fd + Lmd ( id + i‟kd) (9) can be calculated separately by using a suitable trial ‟kd = L‟kd i‟kd + Lmd ( id + i‟fd) (10) and error technique. The controllers are used for ‟kq2 = L‟kq2 i‟kq2 + Lmq iq (11) providing suitable signals for DC-DC buck converter Where the subscripts used are defined as: d, is designed. q: d and q axis quantity, r, s: Rotor and stator 4.5. Wind Turbine Modeling quantity, l, m: Leakage and magnetizing inductance, This block implements a wind energy f, k: Field and damper winding quantity. Rs conversion system. The inputs are actual and desired represents stator resistance, Lls stator leakage speed and the output of the block is mechanical power (Pω) [14]. The amount of power harnessed from the inductance, Lmd and Lmq represent d-axis wind of velocity v is as follows. and q-axis magnetizing inductances. Rf‟ denotes field resistance and Llfd‟ leakage inductance both P=0.5ρAC ν3 (14) referred to the stator. Damper d-axis resistance Rkd‟ Where and leakage inductance Llkd‟, Damper q-axis Pω = wind power in watts resistance Rkq1‟ and leakage inductance Llkq1‟ and the q-axis resistance Rkq2‟ and leakage Inductance ρ = air density in kg/m3 Llkq2‟. All these values are referred to the stator. A= swept area in m2 All rotor parameters and electrical quantiti es are Cp=power coefficient of wind turbine viewed fr om the stator and are identified by ν= wind speed in m/s primed variables. The simplified synchronous 5. Matlab Simulation model of the proposed machine block implements the mechanical system topology described by: The MATLAB Simulation of proposed ∆w (t) = ∫(Tm – Te) dt / (2H) – Kd∆w (t) (12) topology [9] has been shown in the Fig.2. The matlab w(t) = ∆w (t) + wo (13) Simulink tool box simpower has been used for getting `the required results 1902 | P a g e
  • 4. K. Uday Kumar Reddy, M. Ramasekhara Reddy, Dr. M. Vijaya Kumar / International Journal of Engineering Research and Applications (IJERA) ISSN: 2248-9622 www.ijera.com Vol. 2, Issue 5, September- October 2012, pp.1900-1905 Fig. 3. MATLAB Simulated model of PMSG connected to local Load 6. S i m u l a t i o n Results The MATLAB Simulation of proposed topology has been shown in the Fig.3. The MATLAB Simulink tool box Simpower System has been used for getting the required results. 6.1 Performance of PMSG with PWM rectifier with battery for storing the extra wind energy: The wind driven PMSG is run at 300 rpm. The output voltage is 200 V at 60 hertz. This variable voltage and variable frequency o u t p u t i s con ver t ed t o con st an t volta g e an d constant frequency source. The Fig.4 to 8 shows the Variation of speed for the wind Turbine, Variation of Fig.6. Variation of battery power and battery current load power, generated power, battery power, battery current & d c-link voltage using P, PI and PID controllers. The rating of the PMSG is given in the appendix Fig.7. Variation of DC-link voltage using a P- controller The change in the level of power varies with Fig.4. Variation of Speed for the wind turbine respect to the change in load demand. The maximum power generated at the rotor-side of PMSG is 3200 watts and later the change in the level of generated power varies with respect to the variation in load demand at different time instants. The battery energy storage mechanism used in the system regulates the system from severe imbalances by exchanging the energy from generator and the battery. The response of dc-link voltage using a proportional-controller is shown in fig. 7. In fig. 7 though the peak –overshoot is less but the output oscillates around 200 volts. Fig.5. Variation of Generated power and Load side power The load perbutations are made to occur at t=0.5 sec and there is a sudden increase in the level of load side current to 3 amps which draws more current from the generator. After certain period, t=1 sec the current in the load side again reaches to 2 amps. The sudden increase in the current implies that the more current is drawn from the generator and the system balance is obtained by suitable battery energy storage systems. Fig.8. Variation of DC-link voltage using a PI controller 1903 | P a g e
  • 5. K. Uday Kumar Reddy, M. Ramasekhara Reddy, Dr. M. Vijaya Kumar / International Journal of Engineering Research and Applications (IJERA) ISSN: 2248-9622 www.ijera.com Vol. 2, Issue 5, September- October 2012, pp.1900-1905 [3] Ghosh and G. Ledwich, Power Quality Enhancement Using Custom Power Devices. Kulwer Academic, 2002. [4] Gipe, P. Wind power‟, Chelsea Green Publishing Company, Post Mills, Vermount, USA,1995. [5] Rai, G.D. (2000) „Non conventional energy sources‟, Khanna Publishers, 4th Edition, New Delhi (India) [6] Bansal, R.C., Bhatti, T.S., and Kothari, D.P. „On some of the design aspects of wind energy conversion systems”, Int. Journal of Energy Conversion and Management, Nov. Fig.9. Variation of DC-link voltage using a PID Vol. 43, No. 16, pp. 2175- 2187,2002. controller [7] Singh, B. „Induction generator-a The PI-controller offsets or eliminates the prospective‟, Electric Machines and Power steady state oscillations that are occurred using a Systems, Vol. 23, pp. 163-177, 1995. proportional-controller and the system stability is [8] Zouaghi, “Variable Speed Drive modeling improved as shown in fig.8. In fig.9, the output of Wind Turbine Permanent Magnet voltage using PID controller got changed by reducing Synchronous Generator,” ICREP‟04 the peak-overshoot & the time of response got International Conference on Renewable decreased to a certain extent. Hence for economical Energy and Power Quality, Barcelona, savings; PID controller serves better purpose apart Spain, 2004. from the other controllers proposed in this design. So, [9] C. Ong "Dynamic Simulation of Electric PID controller serves the efficient choice for the Machines Using MATLAB/Simulink" selection of the controller. Editorial "Prentice Hall", 1998. [10] D.C. Aliprantis, S.A. Papathanassiou, M.P. 7. Conclusion In the proposed scheme, battery energy Papadopoulos, A.G. Kaladas, “Modeling storage system provides power balance between the and control of a variable-speed wind turbine generated power and the load. The power mismatch is equipped with permanent magnet absorbed by the BESS. From the obtained results it is synchronous generator,” Proc. Of ICEM, Vol.3, pp.558-562, 2000. clearly observed that the oscillations free output can [11] Mukhtiar Singh, A. Chandra,“ Power be obtained by using a PID-controller and PID- Maximization and Voltage Sag/Swell Ride- controller improves the stability of the system and Through Capability of PMSG based hence is the best choice for the selection of the Variable Speed Wind Energy Conversion controller. System” in proc. of 34Th Annual conf. of APPENDIX IEEE Indus. Electronics Society, Permanent Magnet Synchronous Generator: IECON‟08, Orlando, Florida, USA ,2008. 3-Phase, 300 V, 60 Hz, 3000 rpm, 4-pole [12] C. Jauch, J. Matevosyan, T. Ackermann and Electromagnetic Torque : 0.8 Nm S. Bolik. 2005. International comparison of Stator Resistance (RS) : 18.7 Ω requirements for connection of wind Inductance: Ld (H) = Lq(H) : 0.02682 H turbines to power systems. Wind Energy. 8: Flux induced by magnets : 0.1717 Wb. 295-306. References [13] C. Jauch, P. Sorensen and B. Bak-Jensen. [1] R. Mittal, Sandhu, Jain, “Battery energy 2004. International review of grid storage system for a wind driven variable- connection requirements for wind turbines. speed permanent magnet synchronous In: Nordic wind power conference. generator for wind energy conversion Goteborg, March. system”, International Journal of [14] S.N. Bhadra, S. Banerjee, D. Kastha Innovation, Management and Technology, (2005),„Wind electrical systems,„ Oxford Vol. 1, No. 3, August 2010, ISSN: 2010- University Press, 2005, ISBN : 0195670936 248 [15] Bhim Singh and Gaurav Kumar Kasal, [2] Bhim Singh and Gaurav Kumar Kasal, “Solid-State Voltage and Frequency “Voltage and Frequency Controller for a 3- Controller for a stand-alone wind power Phase 4-Wire Autonomous Wind Energy generating system,” IEEE Trans. Power Conversion System” accepted for Electronics, vol. 23, no.3, pp.1170–1177, publication in IEEE Trans. on Energy 2008. Conversion. 1904 | P a g e