• Share
  • Email
  • Embed
  • Like
  • Save
  • Private Content
ifm innovation catalogue 2011
 

ifm innovation catalogue 2011

on

  • 1,561 views

position sensors and object recognition, fluid sensors and diagnostic systems, bus, identification and control systems

position sensors and object recognition, fluid sensors and diagnostic systems, bus, identification and control systems

Statistics

Views

Total Views
1,561
Views on SlideShare
1,561
Embed Views
0

Actions

Likes
0
Downloads
13
Comments
0

0 Embeds 0

No embeds

Accessibility

Categories

Upload Details

Uploaded via as Adobe PDF

Usage Rights

© All Rights Reserved

Report content

Flagged as inappropriate Flag as inappropriate
Flag as inappropriate

Select your reason for flagging this presentation as inappropriate.

Cancel
  • Full Name Full Name Comment goes here.
    Are you sure you want to
    Your message goes here
    Processing…
Post Comment
Edit your comment

    ifm innovation catalogue 2011 ifm innovation catalogue 2011 Document Transcript

    • Innovations 2011www.ifm.com fluid sensors and diagnostic systems position sensors and object recognition bus, identification and control systems
    • www.ifm.comInformation around the clock andaround the globe in 22 languages on the internet. • Information • Selection - product innovations - interactive product selection aids - company news - configuration tools - exhibition info - data sheet direct - locations - jobs • Animation - virtual product animations • Documentation - flash movies (video sequences) - data sheets - operating instructions • Application - manuals - applications - approvals - product recommendations - CAD data - calculation aids • Communication* • Transaction* - request for documents - e-shop processing - recall service - e-procurement catalogues - live advice - B2B services - newsletter * Some offered information is available country-specific.2
    • Convenient order processingvia the e-shop** on the internet. Secured authentication Individual order history Customer-related price Convenient quick input form indication Simple order processing Real time availability check Management of shipping Personal product favourites addresses Online parcel tracking Confirmations by e-mail ** Already available in many countries. 3
    • Position sensors and Inductive sensorsobject recognition ... full-metal sensors for the food industry (04.2011) 6- 7 ... full-metal sensors: now with 2 wire technology (11.2010) 8- 9 ... full-metal sensors: now also as NPN version (11.2010) 10 - 11 Magnetic sensors, cylinder sensors ... T-slot cylinder sensors with integral M8 connector (04.2011) 12 - 13 ... sensors for the categories 1G /1D and 3G / 3D (11.2010) 14 - 15 ... 500 mA load current for T-slot cylinder sensors (11.2010) 16 - 17 Valve sensors ... efector valvis goes AS-i (11.2010) 18 - 19 Photoelectric sensors ... cooling and protection box for distance sensors O1D (04.2011) 20 - 21 ... O7 – small, compact, precise, also as NPN version (11.2010) 22 - 23 ... the new O5: now also NPN versions available (11.2010) 24 - 25 ... safety light grids for hygienic applications (11.2010) 26 - 27 ... safety light grid with active / passive system (11.2010) 28 - 29 Object recognition ... panel PC – for setting and observing the vision sensors (04.2011) 30 - 31 Encoders ... positioned: encoders for mobile applications (04.2011) 32 - 33Fluid sensorsand diagnostic systems Level sensors ... reliable overflow protection for liquids (04.2011) 34 - 35 ... hygienic point level sensor with complementary output (11.2010) 36 - 37 Flow sensors ... MID sensor for precise measurement of drinking water (04.2011) 38 - 39 ... compressed air consumption and leakage monitoring (11.2010) 40 - 41 Pressure sensors ... a breath of fresh air in pneumatics – now also NPN switching (04.2011) 42 - 43 ... IO-Link memory plug – data storage in miniature format (11.2010) 44 - 45 ... the first fully electronic contact manometer (11.2010) 46 - 47 ... contact manometer with conical G1 process connection (11.2010) 48 - 49 ... hydrostatic level measurement in hazardous areas (11.2010) 50 - 51 Temperature sensors ... for fast temperature changes (04.2011) 52 - 53 ... hygienic Pt100 sensors with 4-wire connection (04.2011) 54 - 55 ... head transmitter – the past; temperature plug – the future (11.2010) 56 - 57 ... Pt100 / Pt1000 bolt-on and screw-in sensors (11.2010) 58 - 594
    • Fluid sensors Diagnostic systemsand diagnostic systems ... interface for automation technology: OPC server software (04.2011) 60 - 61 ... permanent vibration monitoring (11.2010) 62 - 63Connection technology Connection technology ... ecolink M8 for hygienic and wet areas (11.2010) 64 - 65Bus systems Bus system AS-Interface ... AS-i Profinet gateway of the third generation (11.2010) 66 - 67Identification systems RF-identification systems ... the UHF system for worldwide use (11.2010) 68 - 69Control systems Control systems for mobile vehicles ... CANremote – remote diagnosis and visualisation (04.2011) 70 - 71 ... ecomatmobile Basic – integrate, activate, operate (11.2010) 72 - 75 ... dialogue module PDM360 NG for mobile vehicles (11.2010) 76 - 77 For further technical data please go to: www.ifm.com 5
    • product news Neat and clean.Position sensors and object recognition Full metal inductive sensors for the food industry. Increased sensing ranges and correction factor 1 for steel and stainless steel. Wide temperature range of 0...100 °C. Temperature shock resistant even in case of frequent temperature fluctuations. High ingress protection: IP 67 / IP 68 / IP 69K; food-grade housing materials. Resistant to high-pressure cleaning and aggressive cleaning agents. Increased sensing ranges The increased sensing ranges for non-flush installation give you more safety in case of mechanical tolerances. Ingress protection in hygienic and wet areas The sensors for use up to 100 °C undergo frequent clean- ing operations, temperature shocks and feature high re- sistance to cleaning agents. Application tests A series of tests qualified the sensors for food applica- tions: • temperature shock test to EN 60068-2-14 Nc • artificial ageing in a 1000-hour long-term test to EN 60068-2-14 Nb (change of temperature) • leak check using the steam boiler test fluid sensors and diagnostic systems position sensors and object recognition bus, identification and control systems 6
    • Inductive sensors Position sensors and object recognitionApplications:hygienic and wet areas in the food industry. Type Dimensions Sensing f Ambient Housing material Order Length range temperature no. [mm] [mm] [Hz] [°C]M12 connector · output function · 3-wire DC PNP M12 L = 70 6 nf 500 0...100 stainless steel 316L / 1.4404 IFT245 M18 L = 70 12 nf 500 0...100 stainless steel 316L / 1.4404 IGT249 M30 L = 70 25 nf 250 0...100 stainless steel 316L / 1.4404 IIT231M12 connector · output function · 3-wire DC NPN M12 L = 70 6 nf 500 0...100 stainless steel 316L / 1.4404 IFT246 M18 L = 70 12 nf 500 0...100 stainless steel 316L / 1.4404 IGT250 M30 L = 70 25 nf 250 0...100 stainless steel 316L / 1.4404 IIT232Dimensions Common technical data IFT245, IFT246 Type 70 IFT, IGT, IIT 59 40 10 M12 x1 M12 x1 Operating voltage [V DC] 10...36 4 Current consumption [mA] < 25 LED 4 x 90° 17 Short-circuit protection, pulsed • Reverse polarity / overload protection •/• IGT249, IGT250 Voltage drop [V] < 2.5 70 57 Protection IP 67 / IP 68 / IP 69K 35 15 Switching status LED yellow (4 x 90°) M12 x1 M18 x1 4 Wiring diagram LED 4 x 90° 24 1 1 L+ L+ 70 IIT231, IIT232 4 4 59 3 3 57 L L 27,5 22,5 PNP NPN M30 x1,5 M12 x1 Connectors and splitter boxes 5 LED 4 x 90° 36 Type Description Order no.Accessories Type Description Order M12 socket, 4-pole, no. EVT001 5 m orange, PVC cable M12 socket, 4-pole, EVT002 Angle bracket for type M12, 10 m orange, PVC cable E10735 stainless steel M12 socket, 4-pole, EVT004 Angle bracket for type M18, 5 m orange, PVC cable E10736 stainless steel M12 socket, 4-pole, EVT005 Angle bracket for type M30, 10 m orange, PVC cable E10737 stainless steel M12 socket, 4-pole, EVT007 5 m orange, PVC cable, LED M12 socket, 4-pole, EVT008 10 m orange, PVC cable, LED For further technical data please go to: www.ifm.com 04.2011 7
    • product news Full metal inductive sensors:Position sensors and object recognition Now with 2-wire technology. Tough: Extremely resistant in M8 to M30 housings. Length only 40 mm: Ideal for compact machines. Non-stick coating against weld spatter. Mechanically resistant to impacts on the sensing face. Setting aided by LEDs. Vibration and shock resistant. Materials Both the threaded body and the sensing face of the housing are made of stainless steel. Use in welding applications The non-stick coating allows weld spatter to roll off the sensor. Use in oils and coolants Long life is achieved due to a special design and additional seals as well as the use of a plastic which is resistant to oil, coolants and lubricants. Setting by LED The setting LED provides rapid adjustment and optimum utilisation of the increased sensing range. fluid sensors and diagnostic systems position sensors and object recognition bus, identification and control systems 8
    • Inductive sensors Position sensors and object recognitionApplications:Metalworking and welding applications Type Dimensions Sensing f Leakage Housing material Pin connection Order Length range current Connector no. [mm] [mm] [Hz] [mA]M12 connectors · 0.3 m PVC cable · output function · 2-wire DC PNP / NPN M8 L = 45 2f 150 0.75 * high-grade stainless steel 1+4 IER203 M8 L = 45 2f 150 0.75 * high-grade stainless steel 3+4 IER206 M12 L = 40 4f 75 0.5 * high-grade stainless steel 1+4 IFR203 M12 L = 40 4f 75 0.5 * high-grade stainless steel 3+4 IFR206 M18 L = 40 6f 50 0.5 * high-grade stainless steel 1+4 IGR203 M18 L = 40 6f 50 0.5 * high-grade stainless steel 3+4 IGR206 M30 L = 40 12 f 25 0.5 * high-grade stainless steel 1+4 IIR203 M30 L = 40 12 f 25 0.5 * high-grade stainless steel 3+4 IIR2063 m PVC cable · output function · 2-wire DC PNP / NPN M8 L = 45 2f 150 0.75 * high-grade stainless steel – IER204 M12 L = 40 4f 75 0.5 * high-grade stainless steel – IFR204 M18 L = 40 6f 50 0.5 * high-grade stainless steel – IGR204 M30 L = 40 12 f 25 0.5 * high-grade stainless steel – IIR2045 m PVC cable · output function · 2-wire DC PNP / NPN M8 L = 45 2f 150 0.75 * high-grade stainless steel – IER205 M12 L = 40 4f 75 0.5 * high-grade stainless steel – IFR205 M18 L = 40 6f 50 0.5 * high-grade stainless steel – IGR205 M30 L = 40 12 f 25 0.5 * high-grade stainless steel – IIR205PUR cable for M8 housing, IER * anti-spatterDimensions Common technical data 40 LED Example IFR203 Type 30 IER, IFR, IGR, IIR M12 x1 4 Operating voltage [V DC] 10...36 11 17 Current rating [mA] 100 Short-circuit protection, pulsed • 49 Reverse polarity / overload protection •/• M12 x1 Ambient temperature [°C] -25...70 Protection IP 67 14 Function displayWiring diagram Switching status LED green Setting aid LED red 1 L+ 2 1 Accessories 4 3 4 L Type Description Order no.PIN 1+4 4 L+ Angle bracket for type M8, 2 1 E10734 stainless steel 3 3 4 L Angle bracket for type M12, E10735 stainless steelPIN 3+4 Angle bracket for type M18, E10736 BN stainless steel L+ Angle bracket for type M30, E10737 BU stainless steel LCable For further technical data please go to: www.ifm.com 11.2010 9
    • product news Full metal inductive sensors:Position sensors and object recognition Now also as NPN version. For nearly all applications. High-quality, robust, ingress- resistant M8 to M30 housings. T series: Absolutely ingress-resistant in hygienic and wet areas. R series: Resistant and robust in welding applications. C series: Resistant to oils and coolants. Vibration and shock resistant. Lasered type label: permanently legible. Unbeatable The sensing face of a full-metal sensor resists mechanical stress such as impacts much better than a sensor with a plastic sensing face. Stainless and strong Non-coated stainless steel housing or innovative non-stick coating contribute to the correct function of the full-metal sensors. Ingress protection in all applications An innovative, consistent sealing concept from the sensor to the connector ensures ideal protection against ingress of moisture. fluid sensors and diagnostic systems position sensors and object recognition bus, identification and control systems 10
    • Inductive sensors Position sensors and object recognition Type Dimensions Sensing f Ambient Protection Housing material Connector Order Length range temperature no. [mm] [mm] [Hz] [°C]For machine tools (oils and coolants) · output function · 3-wire DC NPN M8 L = 50 2f 100 -25...70 IP 67 high-grade stainless steel M8 IEC202 M8 L = 60 2f 100 -25...70 IP 67, IP 68 high-grade stainless steel M12 IEC203 M12 L = 60 3f 100 -25...70 IP 67, IP 68 high-grade stainless steel M12 IFC266 M18 L = 70 5f 100 -25...70 IP 67, IP 68 high-grade stainless steel M12 IGC252 M30 L = 70 10 f 50 -25...70 IP 67, IP 68 high-grade stainless steel M12 IIC226For metalworking and welding applications · output function · 3-wire DC NPN M8 L = 60 2f 100 0...85 IP 67, IP 68 high-grade stainless steel* M12 IER201 M12 L = 60 4f 2 0...85 IP 67 high-grade stainless steel* M12 IFR202 M18 L = 70 6f 2 0...85 IP 67 high-grade stainless steel* M12 IGR202 M30 L = 70 12 f 2 0...85 IP 67 high-grade stainless steel* M12 IIR202For hygienic and wet areas · output function · 3-wire DC NPN M12 L = 60 3f 100 0...100 IP 68, IP 69K high-grade stainless steel M12 IFT244 M18 L = 70 5f 100 0...100 IP 68, IP 69K high-grade stainless steel M12 IGT248 M30 L = 70 10 f 50 0...100 IP 68, IP 69K high-grade stainless steel M12 IIT230* anti-spatter Common technical dataWiring diagram Operating voltage [V DC] 10...36 1 L+ 4 Current consumption [mA] < 20 3 L Short-circuit protection, pulsed • Reverse polarity / overload protection •/• Voltage drop [V] < 2.5Connectors and splitter boxes Function display Type Description Order Switching status LED yellow (4 x 90°) no. Operating status (IFR, IGR, IIR) LED green M12 socket, Accessories EVC001 2 m black, PUR cable M12 socket, Type Description Order EVC002 5 m black, PUR cable no. M12 socket, EVC004 Angle bracket for type M8, 2 m black, PUR cable E10734 stainless steel M12 socket, EVC005 Angle bracket for type M12, 5 m black, PUR cable E10735 stainless steel M12 socket, EVW001* Angle bracket for type M18, 2 m grey, PUR cable E10736 stainless steel M12 socket, EVW002* Angle bracket for type M30, 5 m grey, PUR cable E10737 stainless steel M12 socket, EVW004* Mounting clip for type M12, 2 m grey, PUR cable E11533 stainless steel M12 socket, EVW005* Mounting clip for type M18, 5 m grey, PUR cable E11534 stainless steel Socket, M12, 4-pole, EVT001 5 m orange, PVC cable Mounting clamp M8, PC E11521 Socket, M12, 4-pole, EVT002 10 m orange, PVC cable Mounting clamp M12, PC E11047 Socket, M12, 4-pole, EVT004 5 m orange, PVC cable Mounting clamp M18, PC E11048 Socket, M12, 4-pole, EVT005 10 m orange, PVC cable Mounting clamp M30, PC E11049* anti-spatter For further technical data please go to: www.ifm.com 11.2010 11
    • product news T-slot cylinder sensorsPosition sensors and object recognition with integral M8 connector. Easy installation: quick wiring via M8 connector. Direct connection on the housing for continuous wiring. Self-locking mechanism for easy single-handed installation. Sensing face at the housing front ensures good detection of the end position. Wide range of accessories for different cylinder designs. Stable connector and robust fixing. The family is growing The T-slot cylinder sensor with integral M8 connector on the housing is available as an electronic version or with a reed element. In addition to the two flat standard versions designed for C-slots and T-slots, further applications can now be conveniently implemented thanks to the new design. Thus, the sensor can for example be easily wired from the control cabinet to the cylinder in special machines. The position of the M8 connector on the sensor results in space savings in the cable duct. Furthermore, the en- tanglement in cable loops is minimized. Good fixing and easy installation The ifm sensor has the following advantages: self-locking mechanism, strain relief, drop from the top into the slot, adapters for further cylinder types. fluid sensors and diagnostic systems position sensors and object recognition bus, identification and control systems 12
    • Magnetic sensors,cylinder sensors Position sensors and object recognitionApplications:T-slot cylinder sensors for use in industrial environments such as packaging and handling machines orspecial purpose machinery. Type / Electrical Operating Voltage Ambient Response Iload Order Dimensions design voltage drop temperature sensitivity no. [mm] [V] [V] [°C] [mT] [mA]M8 connector on the housing · output function · 3-wire 35 x 15.5 x 18 PNP 10...30 DC < 2.5 -25...85 2 100 DC MK5900M8 connector on the housing · output function · 3-wire 35 x 15.5 x 18 NPN 10...30 DC < 2.5 -25...85 2 100 DC MK5902M8 connector on the housing · output function · 2-wire AC / DC, 5...50 AC, 100 35 x 15.5 x 18 <5 -25...70 2.1 MR0901 PNP/ NPN 5...60 DC AC / DCM8 connector on the housing · output function · 3-wire AC / DC, 5...50 AC, 350 AC, 35 x 15.5 x 18 <5 -25...70 2.1 MR0902 PNP 5...60 DC 500 DCDimensions Technical data Example MK5900 LED LED display yellow 35 15,5 27,5 Repeatability [mm] < 0.2 Hysteresis [mm] typ. 1 M8x1 Travel speed [m/s] > 10 18 8 Protection IP 65 / 67, III 5 22 PA, Housing material stainless steel, brass Accessories 8,5 Type Description Order no.1) Fixing element Adapter for trapezoidal slot cylinder, E119572) Combined head screw for fixing element aluminium alloy, hexagon socket Adapter for trapezoidal slot cylinder, E11796Connectors and splitter boxes aluminium alloy, slotted screw Type Description Order Adapter for tie rod / profile cylinders, E11797 no. clamping range 5...11 mm, aluminium Adapter for tie rod / profile cylinders, E11799 Socket, M8, 3-pole clamping range 9...15 mm, aluminium EVC141 2 m black, PUR cable Adapter for clean line cylinder, Socket, M8, 3-pole E11877 EVC142 stainless steel 5 m black, PUR cable Socket, M8, 3-pole EVC144 2 m black, PUR cable Clamp for clean line cylinder, Socket, M8, 3-pole E11961 EVC145 Ø 12 mm, POM, aluminium 5 m black, PUR cable Clamp for clean line cylinder, E11958 Socket, M8, 3-pole Ø 16 mm, POM, aluminium EVC147 2 m black, PUR cable, 2 LED Clamp for clean line cylinder, Socket, M8, 3-pole E11959 EVC148 Ø 20 mm, POM, aluminium 5 m black, PUR cable, 2 LED Clamp for clean line cylinder, E11960 Ø 25 mm, POM, aluminium Clamp for clean line cylinder, E12017 Ø 32/36 mm, POM, aluminium Clamp for clean line cylinder, E12015 Ø 40/45 mm, POM, aluminium For further technical data please go to: www.ifm.com 04.2011 13
    • product news Safe and reliable: T-slot cylinderPosition sensors and object recognition sensor for ATEX applications. Sensor for the categories 1G /1D (zone 0/20) and 3G / 3D (zone 20/22). Sensor developed to the EN 60947-5-6 standard. Everything from a single source: sensor and switching amplifier available. One sensor which can be used for different cylinder types. Easy single-handed installation with clamp fixing. Supplied adapter for impact protection for category 3G / 3D. The family is growing The T-slot cylinder sensors for all ATEX applications com- plement the ifm range of cylinder sensors for pneumatic cylinders. Good fixing and easy installation The ifm sensors have the following proven advantages: self-locking mechanism, strain relief, easy single-handed installation, clearly visible LED display for the switching status. Wide range of adapters With the range of accessories, these sensors can be fixed to common T-slot, tie rod, integrated profile or trapezoidal slot cylinders. In addition to the sensors, ifm offers a wide range of switching amplifiers. fluid sensors and diagnostic systems position sensors and object recognition bus, identification and control systems 14
    • Magnetic sensors,cylinder sensors Position sensors and object recognitionApplications:Silo hatches, elevators, mills or conveying technology. Equipment group / Type / Operating Protection Ambient Housing Order ATEX category Dimensions voltage temperature material no. [mm] [V] [°C]Connection cable 6 m PVC · output function · 2-wire II, 1D/1G 25.3 x 5 x 6.5 8.2 DC IP 65 / IP 67, III -25...70 PA, stainless steel MK502AConnection cable 6 m PVC · output function · 3-wire II, 3D/3G 25.3 x 5 x 6.5 10...30 DC IP 65 / IP 67, III -20...60 PA, stainless steel MK503ADimensions Technical data LED LED display yellow 6,5 5,1 Repeatability [mm] < 0.2 Reverse polarity protection • 25,3 Hysteresis [mm] typ. 1 12 Travel speed [m/s] > 10 5 Response sensitivity [mT] typ. 2.0 5,7 21) Clamping screw2) Sensing faceAccessories Type Description Order no. Adapter for trapezoidal slot cylinder, E11988 aluminium alloy Adapter for tie rod / profile cylinders, E12231 clamping range 5...11 mm, aluminium Adapter for tie rod / profile cylinders, E12232 clamping range 9...13.5 mm, aluminium Switching amplifier, N0530A 1 channel, relay output Switching amplifier, N0533A 2 channels, relay output Switching amplifier, N0531A 1 channel, transistor output Switching amplifier, N0534A 2 channels, transistor output For further technical data please go to: www.ifm.com 11.2010 15
    • product news 500 mA load current forPosition sensors and object recognition T-slot reed sensors. 3-wire cylinder sensors for the AC or DC voltage range. As 3-wire sensors adaptable to all common controllers. Wide temperature range of -25...70 °C. Connection via cable, M8 or M12 connector. Self-locking mechanism for easy single-handed installation. Convenient: easy and quick fit “drop from the top” into a slot. A sensor for high demands For applications with high load currents up to 500 mA the family of T-slot cylinder sensors now features corre- sponding sensors. They can be reliably adapted to all common cylinder types. The self-locking mechanism as well as the easy positio- ning in the T-slot allow comfortable one-hand installa- tion. The sensor is fixed by a combined head screw. This also provides excellent strain relief. A sensor for almost any cylinder profile Thanks to the wide selection of adapter accessories the T-slot sensor can be fixed to almost every T-slot, clean line, tie rod, integrated profile or trapezoidal slot cylinder. Storage and mounting time can thus be reduced. fluid sensors and diagnostic systems position sensors and object recognition bus, identification and control systems 16
    • Magnetic sensors,cylinder sensors Position sensors and object recognitionApplications: T-slot cylinder sensors for use in industrial environments such as packaging orhandling machines. Housing / Electrical Operating Voltage Ambient Response Iload Order Dimensions design voltage drop temperature sensitivity no. [mm] [V] [V] [°C] [mT] [mA]Connection cable 0.3 m PUR with M8 connector · output function · 3-wire 30.5 x 5 x 6.5 AC/DC, PNP 5...50 AC/DC ≤1 -25...70 typ. 2.1 350 AC, 500 DC MR0119Connection cable 0.3 m PUR with M8 connector rotatable · output function · 3-wire 30.5 x 5 x 6.5 AC/DC, PNP 5...50 AC/DC ≤1 -25...70 typ. 2.1 350 AC, 500 DC MR0120Connection cable 2 m PUR · output function · 3-wire 30.5 x 5 x 6.5 AC/DC, PNP 5...50 AC/DC ≤1 -25...70 typ. 2.1 350 AC, 500 DC MR0122Connection cable 6 m PUR · output function · 3-wire 30.5 x 5 x 6.5 AC/DC, PNP 5...50 AC/DC ≤1 -25...70 typ. 2.1 350 AC, 500 DC MR0123Connection cable 0.3 m PUR with M12 connector · output function · 3-wire 30.5 x 5 x 6.5 AC/DC, PNP 5...50 AC/DC ≤1 -25...70 typ. 2.1 350 AC, 500 DC MR0121Dimensions Common technical data Example MR0119 LED LED display yellow Repeatability [mm] < 0.2 6,5 5,7 Switching frequency [Hz] 1000 Short-circuit protection – 30,5 37 13 Protected against reverse polarity – Protection IP 65 / IP 67, III M8x1 5 5,7 Hysteresis [mm] typ. 1 L 2 Travel speed [m/s] > 101) Clamping screw PA, Housing material2) Sensing face stainless steel Switching operations 40 millionAccessories of purely ohmic load Type Description Order Connectors and splitter boxes no. Type Description Order Adapter for trapezoidal slot cylinder, no. E11988 aluminium alloy, hexagon socket Socket, M8, 3-pole, EVC141 2 m black, PUR cable Adapter for tie rod / profile cylinders, Socket, M8, 3-pole, E12231 EVC142 clamping range 5...11 mm, aluminium 5 m black, PUR cable Adapter for tie rod / profile cylinders, Socket, M8, 3-pole, E12233 EVC144 clamping range 9...17 mm, aluminium 2 m black, PUR cable Memorisation block for T-slot, Socket, M8, 3-pole, E11798 EVC145 PA, stainless steel 5 m black, PUR cable Socket, M8, 3-pole, EVC147 2 m black, PUR cable, 2 LED Adapter for SMC cylinder ECDQ2, Socket, M8, 3-pole, E11890 EVC148 aluminium 5 m black, PUR cable, 2 LED Adapter for SMC cylinder CDQ2, E11891 aluminium Adapter for SMC cylinder CP95, E11872 aluminium For further technical data please go to: www.ifm.com 11.2010 17
    • product news efector valvis goes AS-i.Position sensors and object recognition Position feedback for single, double seat and diaphragm valves. Integrated AS-i chip for direct connection to the AS-i bus system. Freely programmable valve positions: open / closed / seat lift. Resolution of 0.2 mm across the entire measuring range. Maximum valve stroke: 80 mm. Applications efector valvis has been designed for feedback of posi- tions on single, double seat and diaphragm valves up to a stroke of 80 mm. The optional adapters allow installation of the sensor to the most common valve types. Feedback via AS-i In addition to the binary 24 V DC version the output sig- nals of efector valvis can now be transferred directly via the AS-i bus. Up to 31 sensors can be connected to one master. AS-i power and communication errors are indicated by LEDs on the unit. fluid sensors and diagnostic systems position sensors and object recognition bus, identification and control systems 18
    • Valve sensors Position sensors and object recognition Measuring Resolution Materials Protection Ambient Reverse polarity Order distance temperature protection no. [mm] [mm] [°C]Connection cable 0.3 m pigtail · 3 valve positions, programmable 80 0.2 PA, PP, TPE IP 65, IP 67 / III -25...70 • IX5030Dimensions Further technical data 65 Max. target speed [m/s] 1 Operating voltage (AS-i) [V DC] 26.5...31.6 AS-i specification 3.0 Extended addressing mode – 88,6 110 99,6 80 Wiring diagram 4,5 15,5 26,5 1 AS-i+ 26 6,2 34,8 3 3 AS-i 38 Valve adapter (without valve sensor) Type Description Order no. Adapter Alfa Laval E11900 52 4 4,3 Adapter Südmo up to DN 100 E119891) Max. spindle stroke2) Measuring distance3) Initial value of the measuring range (zero point)4) Programming buttons5) LED green = open; LED red = close Adapter GEMÜ E120426) LED green = AS-i voltage; LED red = error7) LED yellow = seatAccessories Adapter GEMÜ E12043 Type Description Order no. FC splitter, high-grade stainless steel E70454 Adapter Georg Fischer E12009 type Diastar FC splitter stainless steel, E70354 Adapter Georg Fischer AS-i / 24 V via M12 E12010 type Diastar AS-i flat cable „Food Automation“ AC4007 yellow Adapter Bardiani E12170For a detailed selection tool sorted by valve manufacturers Adapter Kieselmann E12123please go to:www.ifm.com/ifmgb/web/adapter_sel.htm For further technical data please go to: www.ifm.com 11.2010 19
    • product news Keep cool!Position sensors and object recognition Cooling and protection box for distance sensors of the O1D series. Use for ambient temperatures up to 180 °C. Robust metal housing with integrated cooling circuit. Water or air cooling possible. Standardised tube connections with 3/8". If things are getting heated! In case of ambient temperatures up to 180 °C, powerful electronics should be cooled to protect them from over- heating. Using the cooling box, the distance sensor O1D with PMD technology can now also prove its performance in hot applications such as in the steel industry. Cooling or protection box After connection to a cooling circuit via the standardised 3/8" tube connections, the temperature on the inside of the cooling box can be cooled down to an “electronics- friendly” temperature. If you screw off the tube connec- tions, the box can be used as pure protection box for very harsh operating conditions. fluid sensors and diagnostic systems Position detection of steel slabs in a rolling mill. position sensors and object recognition bus, identification and control systems 20
    • Photoelectric sensors Position sensors and object recognitionApplications:Steel producing / steel processing industry / glass industry Dimensions Max. Material Diameter Order WxHxD operating temperature cable entry no. [mm] [°C] [mm]Cooling and protection box for distance sensors of the O1D series 180 (water cooling) aluminium, anodised, glass 70 x 109 x 108 4...9 E21248 100 (air cooling) nickel-plated brass, NBR, FPMThe sensor shown is not part of the article E21248!Connectors and splitter boxes Accessories Type Description Order Type Description Order no. no. M12 socket, wirable Mounting set for clamp mounting E11509 E3D103 4-pole, PA, nickel-plated brass (without rod), Ø 14 mm, stainless steel High temperature resistant cable, 180 °C, Rod, 100 mm, Ø 14 mm, E12274 E20939 4 wires, silicone, 10 m M12 thread, stainless steel Rod, 200 mm, Ø 14 mm, E21228 stainless steel Rod, 300 mm, Ø 14 mm, E21229 stainless steel Rod, 500 mm, Ø 14 mm, E21232 stainless steel Temperature curve minimum volumetric flow quantity water (20°): Q [l/min] 0,5 0,4 0,3 0,2 0,1 0 0 50 100 150 200 T [°C] minimum volumetric flow quantity air (20°): Q [l/min] 1000 800 600 400 200 0 20 40 60 80 100 T [°C] Q: volumetric flow quantity in litres per minute T: ambient temperature in degrees Celsius For further technical data please go to: www.ifm.com 04.2011 21
    • product news The youngest of the opto family:Position sensors and object recognition O7 – small, compact, precise. Powerful photoelectric sensors in a small design. Now also with NPN output. Ideal for position detection in feeding and handling. Through-beam, retro-reflective and diffuse reflection sensors with fixed setting. Visible red light for an easy alignment. Diffuse reflection sensor with precise background suppression. Small light spot for detecting small objects. Applications Whenever there is little space for sensors or when small parts are to be detected, the small photoelectric sensors of the O7 series are the ideal problem solvers. Typical applications are feeding and handling technology. The user can choose between units with PNP or NPN output. Advantages The small light spot and the narrow light cone enable the detection of small objects even over long distances. With their fixed setting, the sensors are ready for operation immediately after installation (plug & play). Diffuse reflec- tion sensors with background suppression with 30, 50 or 100 mm range are available. Visible red light allows fast and simple alignment. fluid sensors and diagnostic systems position sensors and object recognition bus, identification and control systems 22
    • Photoelectric sensors Position sensors and object recognitionApplications:Handling technology, robotics and automation System Range Light spot Switching Light-on / Current Order Order diameter frequency dark-on consumption no. no. [mm] [mm] [Hz] mode [mA]M8 connector (3 poles) with 200 mm PUR cable · 3-wire DC NPN PNP Diffuse reflection sensor with 1...30 2.5 750 •/– 20 O7H206 O7H200 background suppression 1...30 2.5 750 –/• 20 O7H207 O7H201 Diffuse reflection sensor with 0...50 2.5 750 •/– 20 O7H208 O7H202 background suppression 0...50 2.5 750 –/• 20 O7H209 O7H203 Diffuse reflection sensor with 0...100 7 750 •/– 20 O7H210 O7H204 background suppression 0...100 7 750 –/• 20 O7H211 O7H205 Retro-reflective sensor with 3...1000 55 1000 –/• 20 O7P202 O7P200 polarisation filter 3...1000 55 1000 •/– 20 O7P203 O7P201 Through-beam – transmitter 0...1500 90 – – 20 – O7S200 0...1500 – 1000 –/• 10 O7E202 O7E200 Through-beam – receiver 0...1500 – 1000 •/– 10 O7E203 O7E201Accessories Common technical data Type Description Order Type no. O7 Mounting set for clamp mounting, Type of light red light 632 nm E21237 stainless steel Operating voltage [V] 10...30 DC Current rating [mA] 100 Voltage drop [V] < 2.5 Mounting set for free-standing E21238 Short-circuit protection, pulsed • mounting, stainless steel Reverse polarity / overload protection •/• Ambient temperature [°C] -25...60 Mounting set for free-standing mounting Function display E21239 yellow with fine adjustment, stainless steel Switching status LED Materials housing PA lens PMMA cable PUR Mounting set with ball joint, E21240 Protection IP 65, III galvanised, stainless steel Dimensions Mounting rod, 120 mm, Ø 10 mm, LED Example O7P200 E21081 15 9 M8 thread, stainless steel 6,5 20,3 2,7 26 Cube for mounting on an aluminium E20950 profile, M8 thread, diecast zinc 7,6 M3 9 Prismatic reflector 50 x 50 mm, E20744 plastics For further technical data please go to: www.ifm.com 11.2010 23
    • product news The O5 family is growing continuously:Position sensors and object recognition Now also available as NPN version. Photocells with excellent performance at low price. The new standard for packaging and conveying. Extremely long ranges. Highest precision with background suppression. Easy setting: The new Teach mode. Universal mounting with system components and mounting accessories. All-round photocell With state-of-the-art technology as well as outstanding performance and an excellent price /performance ratio this range is perfect for universal use. Easy installation is ensured by a clever mounting concept, with special fix- tures as well as an adapter plate. The plug can be ro- tated by 270° so that it can be aligned in any direction. Versions with potentiometer, for simple setting in simple applications. Versions with teach function. The innovative teach method means complex program- ming is no longer required. The unit features one button each for teaching of a precise on and off state for the sensor signal. fluid sensors and diagnostic systems position sensors and object recognition bus, identification and control systems 24
    • Photoelectric sensors Position sensors and object recognitionApplications:Position detection in packaging and conveying Ranges 240° potentiometer / Switching Spot Ø at Light-on / Current Output Order teach button frequency max. range dark-on consumption function no. [mm] [Hz] [mm] [mA]Diffuse reflection sensor · red light 624 nm · M12 connector · background suppression 50...1400 •/– 1000 50 •/– 25 NPN O5H201 50...1800 –/• 1000 50 programmable 25 NPN O5H504Retro-reflective sensor · red light 624 nm · M12 connector · polarisation filter 75...10000 –/• 2000 250 programmable 20 NPN O5P502Through-beam sensor · red light 624 nm · M12 connector · transmitter 0...25000 –/– – 625 programmable 20 – O5S500Through-beam sensor · red light 624 nm · M12 connector · receiver 0...25000 –/• 1000 – programmable 11 NPN O5E502System components Common technical data Type Description Order no. Operating voltage [V] 10...36 DC Dimensions (W x H x D) [mm] 18.5 x 70.3 x 46.8 Mounting bracket for rod E21083 Complete set incl. clamp Current rating [mA] 200 Voltage drop [V] < 2.5 Short-circuit protection, pulsed • Protective bracket for rod Reverse polarity / overload protection •/• E21084 Complete set incl. clamp Ambient temperature [°C] -25...60 Protection IP 67, II EMC DIN EN 60947-5-2 Universal angle bracket E21085 Material: Housing / plug adapter PA Front lens / LED window PMMA Front frame stainless steel Operator interface TPU Bracket for free-standing mounting E21087 Connectors and splitter boxes Type Description Order no. Dovetail clamp E21088 Socket, M12, EVC001 2 m black, PUR cable Socket, M12, EVC002 5 m black, PUR cable O5 adapter E21114 with OC centres Socket, M12, EVC004 2 m black, PUR cable Socket, M12, EVC005 5 m black, PUR cable Wall mounting (dove tail) E21122 with OL centres Prismatic reflector 50 x 50 mm, E20744 plastics Prismatic reflector Ø 80 mm, E20005 plastics For further technical data please go to: www.ifm.com 11.2010 25
    • product news The safest bet forPosition sensors and object recognition hygiene-critical domains. Safety light grids for hygienic applications. Safety light curtains with protective tube and protection rating IP 69K. SIL to IEC 61508 and PL to ISO 13849. Versions with ranges of 5, 9 or 15 m available. Resistant to steam and high-pressure cleaning. Hygienic and robust design. Hygienic and safe The new safety light curtains with protective tube and protection rating IP 69K are designed without corners and edges. They possess properties which are required in hygienic as well as robust applications. For example, the ECOLAB certification guarantees excellent material resistance in cleaning processes. Certified safety The safety light curtains and light grids have been deve- loped in accordance with the current standards and cer- tified by TÜV Süd. They conform to the requirements of type 2 / SIL 2 or type 4 / SIL 3. So, you are on the safe side if you need primary guar- ding or access prevention. fluid sensors and diagnostic systems position sensors and object recognition bus, identification and control systems 26
    • Photoelectric sensors Position sensors and object recognitionApplications:Hygienic and wet areas, food industry.Safety light curtains Resolution / Protected area height detection capacity [mm] [mm] 160 310 460 610 760 910 1060 1210 1360 1510 Type 4 / SIL 3 / PLe Protected area width 0...2 m / 1...5 m 14 – – OY403S – OY405S – OY407S – – – Type 2 / SIL 2 / PLd Protected area width 0...3 m / 2...10 m 30 OY431S OY432S OY433S OY434S OY435S OY436S OY437S OY438S OY439S OY440S Type 4 / SIL 3 / PLe Protected area width 0...7 m / 3...15 m 30 OY441S OY442S OY443S OY444S OY445S OY446S OY447S OY448S OY449S OY450SSafety light grids Common technical data 2 beams 3 beams 4 beams Safety light curtains / light grids with protective tube IP 69K Type 2 Protected area width 0...3 m / 2...10 m Dimensions [Ø mm] 50 SIL 2 PLd OY411S OY412S OY413S Operating voltage [V] 19.2...28.8 Current consumption [mA] Type 4 Protected area width 0...7 m / 3...15 m transmitter 42 SIL 3 receiver 83 PLe OY421S OY422S OY423S Safety outputs (OSSDs) 2 x PNPEvaluation unit Ambient temperature [°C] -20...55 Protection IP 65, IP 67, IP 69K Type Description Order no. Current rating [mA] 2 x 400 Connection PUR cable, 6 m, 8 x 0.34 mm² Safety relay, Max. cable length [m] 100 multifunctional, G1501S 2 relay outputs Safety relay, 2 G2001S relay outputs, muting functionAS-i bus system Type Description Order no. Safe AS-i input module, 2 OSSD inputs AC007S via M12 connector Safe SmartLine output module AC030S 4 DI / 1 SO R For further technical data please go to: www.ifm.com 11.2010 27
    • product news Mirror, mirror on the wall...Position sensors and object recognition Safety light grid with active / passive system. Single-sided wiring as transmitter and receiver are integrated in one housing. SIL to IEC 61508 and PL to ISO 13849. Easy programming via wiring, no software or such like required. Standardised connection via 8-pole M12 connector. For applications with ranges of up to 60 m (transmitter / receiver principle). One housing, two tasks The transmitter and the receiver are integrated in the housing of the active element. The passive element houses the reflecting mirrors. The electrical connection is only located on one side, this being the side of the active element. Thus, the user saves time and money with regard to wiring. Monitoring of an extra large area Via the common transmitter / receiver principle safety light grids now monitor ranges of up to 60 m. Easy wiring The units are configured via the pin connection of the 8- pole M12 connector. No PC or software is needed. Func- tions such as EDM, restart or external muting are easy to implement. fluid sensors and diagnostic systems position sensors and object recognition bus, identification and control systems 28
    • Photoelectric sensors Position sensors and object recognitionApplications:Conveyor technology, protection of robot cells.Safety light grid with active / passive system Common technical data 2 beams 3 beams 4 beams Safety light grid Type 4 Protected area width 0...6 m Dimensions (W x D) [mm] 50 x 60 SIL 3 PLe OY901S OY902S OY903S Operating voltage [V] 19.2...28.8 Safety outputs (OSSDs) 2 x PNPSafety light grid transmitter / receiver Ambient temperature [°C] -10...55with a range of up to 60 m Protection IP 65 2 beams 3 beams 4 beams Current rating [mA] 2 x 400 Connection M12 connector Max. cable length [m] 100 Type 4 Protected area width 8...30 m / 18...60 m SIL 3 PLe OY951S OY952S OY953S Connectors and splitter boxes Type Description OrderEvaluation unit no. Type Description Order no. Socket, M12, 5 m, 8-pin, PUR E12166 Socket, M12, 10 m, 8-pin, PUR E12167 Safety relay, multifunctional, G1501S Socket, M12, 5 m, 8-pin, PUR E12168 2 relay outputs Socket, M12, 10 m, 8-pin, PUR E12169 Socket, M12, 2 m, 5-pin, PUR EVC070 Safety relay, Socket, M12, 5 m, 5-pin, PUR EVC071 2 G2001S relay outputs, Socket, M12, 10 m, 5-pin, PUR EVC072 muting function Socket, M12, 2 m, 5-pin, PUR EVC073 Socket, M12, 5 m, 5-pin, PUR EVC074AS-i bus system Socket, M12, 10 m, 5-pin, PUR EVC075 Type Description Order no. Safe AS-i input module, 2 OSSD inputs AC007S via M12 connector Safe SmartLine output module AC030S 4 DI / 1 SO R For further technical data please go to: www.ifm.com 11.2010 29
    • product news Keep track even in harshPosition sensors and object recognition environments! Panel PC – for setting and observing the vision sensors in your application. 12.1" touch-screen display with a resolution of 1024 x 768 pixels. Windows XP EmbeddedTM operating system, ifm software pre-installed. WLan and USB 2.0, Gbit LAN, CAN-BUS, RS-232, RS-422, RS-485 interfaces. Robust and industrially-compatible housing with protection rating IP 64 (on the front face). Technical data The industrially compatible small computer is equipped with a 12.1" touch-screen with a resolution of 1024 x 768 pixels. The required performance is achieved by using a fan-less Intel® AtomTM N270 processor with a clock fre- quency of 1.6 GHz, 1 GB RAM and a 2 GB compact flash card as a robust hard disc substitute. Windows XP EmbeddedTM has been installed as operat- ing system, besides the ifm user software, for the vision sensors. Industrially-compatible design A power consumption of only 32 watts combined with a fan-less design form a sound basis for a continuous use of the display. When installed in the control panel the front face of the plastic housing has a protection rating of IP 64. fluid sensors and diagnostic systems position sensors and object recognition bus, identification and control systems 30
    • Object recognition Position sensors and object recognitionApplications:Monitor for object recognition and identification sensors. Dimensions Image brightness Colour contrast Colour depth Resolution Image diagonal Order max. no. [mm] [cd/m2]Intel® AtomTM N270 processor with 1.6 GHz clock frequency, 1 GB RAM, 2 GB Compact Flash 304 x 246 x 49.5 400 500 : 1 262 K 1024 x 768 12.1" E2D400Accessories Further technical data Type Description Order no. Display touch screen Operating voltage [V] 12 DC Parameter setting cable, cross-over, E11898 2 m PUR, M12 D-coded / RJ45 Ambient temperature [°C] -10...50 Approvals / test certificates CE / FCC / CB / CCC Power consumption [W] 32 Mounting accessories Weight [kg] 1,8 E2D401 for wall mounting Protection IP 64 Power supply external (supplied) Mounting accessories E2D402 for control cabinet mounting Dimensions 20 186,5 246 221 248 20 24 304 49,5 1: Insertion slots for control cabinet mounting For further technical data please go to: www.ifm.com 04.2011 31
    • product news Positioned:Position sensors and object recognition encoders for mobile applications. Robust multiturn encoder for harsh operating conditions. Easy connection via M12 connector. Clearly visible diagnostic LEDs. Easy software parameter setting via CAN interface. 24 bit resolution, 4096 steps and 4096 revolutions. Compact dimensions. Features and advantages The multiturn encoder converts 4096 revolutions into one absolute position value. The gear-free system uses the Wiegand effect to keep the position values stored in case of a power failure without battery buffer and to pass the exact position on to the controller without referencing. The multiturn encoder can be easily connected to the CAN bus of the external electronics via M12 connector. The requirements of harsh environments are met due to the high protection rating and the EMC requirements to e1 type approval. fluid sensors and diagnostic systems The multiturn encoder converts rotary movements into position sensors position values. and object recognition bus, identification and control systems 32
    • Encoders Position sensors and object recognitionApplications:From rotary movements to absolute positon values under harsh environmental conditions.Dimensions Technical data Type RM9000 100 57 Operating voltage [V DC] 10...30 36,5 4 30 4 ≤ 100 (10 V DC); 24 23 36 9 20 Current consumption [mA] ≤ 50 (24 V DC) 10 M12 x1 Interface CANopen Resolution 24 bits Measuring units per revolution 4096 LED Number of revolutions 4096 DSP 406 V3.1, Supported profiles DS 301 V4.02,1: M4, 6 mm deep DS 306 V2.0 Output code binaryConnectors and splitter boxes Precision [°] ± 0.25 Type Description Order Maximum mechanical [1/min] no. 6000 rotational speed Ambient temperature [°C] -40...85 Socket, M12, 5-pole, E11986 2 m, PUR cable Protection IP 67, IP 68, IP 69K / III Socket, M12, 5-pole, Shock resistance [g] 120 (6 ms) E11987 10 m, PUR cable Vibration resistance [g] 20 (55…2000 Hz) Socket, M12, 5-pole, Shaft load [N] axial 40, radial 60 E12074 10 m, PUR cable Diagnosis LED green operating status red error message 1: CAN_GND Socket, M12, 5-pole, 2: VBBc EVM036 Wiring 3: GND (PE) 2 m, PUR cable 4: CAN_High Socket, M12, 5-pole, 5: CAN_Low EVM037 5 m, PUR cable Socket, M12, 5-pole, EVM038 Accessories 10 m, PUR cable Type Description Order no. Socket, M12, 5-pole, Fastening clamp for synchro flange, EVM039 E60041 2 m, PUR cable steel Socket, M12, 5-pole, EVM040 5 m, PUR cable Socket, M12, 5-pole, Flexible coupling with adjusting screws, EVM041 E60022 10 m, PUR cable Ø 10 mm / 10 mm, aluminium Flexible coupling with adjusting screws, E60028 Ø 6 mm / 10 mm, aluminium Flexible coupling with clamp connection, E60066 Ø 6 mm / 10 mm, aluminium Flexible coupling with clamp connection, E60067 Ø 10 mm / 10 mm, aluminium Angle brackets E60302 For further technical data please go to: www.ifm.com 04.2011 33
    • product news Overflow impossible!Fluid sensors and diagnostic systems Reliable overflow protection of liquids. Overflow protection to the German Federal Water Act (WHG) section 19. Clearly visible switching status indication. Easy pushbutton adjustment in the application. Extended setting range for increased application reliability. Modular mounting concept for flexible use. Reliable in the application The new point level sensors of the LI21 series have been optimised for use in hydraulic oils and coolants. They are used to monitor the minimum level, leakage or overflow of tanks. The extended setting range increases the appli- cation reliability. Easy set-up The new operating concept enables setting and adjust- ment of the output function by pressing just one push- button. Deposits can be suppressed during operation without carrying out a complete new adjustment. Reliable The LI21 series is approved to the German Federal Water Act (WHG) section 19. fluid sensors and diagnostic systems position sensors and object recognition bus, identification and control systems 34
    • Level sensors Fluid sensors and diagnostic systemsApplication:Hydrous coolants, oils, water / media similar to water.Overflow protection to the German Federal Water Act (WHG) section 19. Installation length Teach Protection Medium Medium Order button temperature temperature no. [mm] Oil WaterM12 connector · output function · DC PNP, 4-pole · WHG § 19 132 • IP65 / IP67, II 0...65 °C 0..35 °C LI2141 273 • IP65 / IP67, II 0...65 °C 0..35 °C LI2142 480 • IP65 / IP67, II 0...65 °C 0..35 °C LI2143Dimensions Other technical data Operating voltage [V] 10...36 DC M12 x1 53 L 21,3 Current rating [mA] 200 Voltage drop [V] < 2.5 16,6 16 A Current consumption [mA] < 22 LED 1 Dielectric constant medium > 1.8 Max. tank pressure [bar] ± 0.51) programming buttons Ambient temperature [°C] 0...65 Materials PP (wetted parts)Wiring diagram EN 61000-6-2:2005 EMC EN 61000-6-4 1 L+ 4 Connectors and splitter boxes 3 L Type Description Order no.Accessories Socket, M12, 4-pole EVC004 2 m black, PUR cable Type Description Order no. Socket, M12, 4-pole EVC005 5 m black, PUR cable Mounting set Ø 16 mm, PP E43016 Socket, M12, 4-pole EVC007 2 m black, PUR cable, LED Socket, M12, 4-pole EVC008 5 m black, PUR cable, LED Mounting adapter G 3/4 D16, E43019 nickel-plated brass Flange plate 73-90 D16, E43001 aluminium, anodised Flange plate 65-80 D16 E43006 aluminium, anodised For further technical data please go to: www.ifm.com 04.2011 35
    • product news New level sensor, ignores foamFluid sensors and diagnostic systems and build up. Hygienic point level sensor with complementary output. Default setting at the factory makes adjustment to the medium unnecessary. Hygienic design with maintenance-free sealing concept. Robust stainless steel housing with laser type label for durable legibility. Resistant to foam and deposits. Easy mounting thanks to orientation-independent installation. Level under control The new hygienic point level sensor LMT safely monitors the level in storage tanks or protects pumps against run- ning dry. Its compact sensor tip allows integration even in small DN25 pipes. Plug & Play The factory setting to different types of media makes adjustment unnecessary, even for viscous and sticky pro- ducts such as ketchup. The unit is selected using an extensive media list. Food-grade The sensor with its high-quality housing materials such as high-grade stainless steel (316L / 1.4404) and PEEK meets all requirements for hygienic areas. A lasered type label for durable legibility as well as the high protection rating IP 68 / IP 69K for cleaning processes are natural. fluid sensors and diagnostic systems position sensors and object recognition bus, identification and control systems 36
    • Level sensors Fluid sensors and diagnostic systems Process connection Maximum Application Protection Order process pressure no. [bar]M12 connector · output function complementary · 4-wire DC PNP G 1/2 -1...16 hydrous media* IP 68 / IP 69K, III LMT100 G 1/2 -1...16 oils, fats, bulk materials* IP 68 / IP 69K, III LMT110* For a detailed media list see www.ifm.comAccessories Further technical data Type Description Order no. Operating voltage [V] 18...30 DC Adapter G 1/2 I – Clamp 1"–1.5" E33401 Current rating [mA] 50 Medium temperature [°C] 0...85 / Adapter G 1/2 I – Clamp 2" E33402 Hydrous media 150 (1 h) Medium temperature [°C] 0...100 / Welding adapter ball, G 1/2 E30055 Oils, fats, bulk materials 150 (1 h) PEEK, high-grade stainless Welding adapter collar, G 1/2 E30056 Housing materials steel (316L/1.4404), PA12, FPM Welding adapter, Materials E43300 PEEK cylindrical, G 1/2 (wetted parts) Welding adapter, Shock resistance [g] 50 E43301 cylindrical for pipes, G 1/2 Vibration resistance [g] 20 Ambient temperature [°C] 0...60 Adapter G 1/2 I – G 3/4 A E43302 EMC EN 6100-6-2:2005 closed tanks: EN 6100-6-3:2006 Adapter G 1/2 I – G 1 A E43303 open tanks: EN 6100-6-4:2006 Function display LED Adapter G 1/2 I – DIN 11851 DN25 E43304 yellow Switching status Adapter G 1/2 I – DIN 11851 DN40 E43305 Wiring diagram 1 Adapter G 1/2 I – Varivent D50 E43306 L+ 2 4 Adapter G 1/2 I – Varivent D68 E43307 4: 2: 3 L Cover plug G 1/2 E43308 Connectors and splitter boxes Type Description Order no.Accessories 3-A Socket, M12, Type Description Order EVT001 5 m orange, PVC cable no. Socket, M12, EVT002 10 m orange, PVC cable Welding adapter, E43309 cylindrical, G 1/2 (3-A) Socket, M12, EVT004 Welding adapter, 5 m orange, PVC cable E43310 cylindrical for pipes, G 1/2 (3-A) Socket, M12, EVT005 10 m orange, PVC cable Adapter G 1/2 I – Clamp 1"–1.5" (3-A) E43311 Socket, M12, EVT007 5 m orange, PVC cable, LED Adapter G 1/2 I – Clamp 1"–2" (3-A) E43312 Socket, M12, EVT008 10 m orange, PVC cable, LED For further technical data please go to: www.ifm.com 11.2010 37
    • product news Measurements that hold water!Fluid sensors and diagnostic systems MID volumetric flow sensor for precise measurement of drinking water. High accuracy, repeatability and measurement dynamics. Suitable for conductive media from 20 μS/cm, flow rate up to 100 l/min. EPDM O-ring for drinking water applications. Different process connections possible using adapters With flow rate, totalising and temperature indication. Measurement technique The flow sensor is based on Faraday’s principle of induc- tion. The conductive medium flowing through a pipe in a mag- netic field generates a voltage which is proportional to the flow velocity or flow rate. Device function This voltage is detected via electrodes and converted in the evaluation electronics. Analogue, binary and pulse outputs offer various possi- bilities to process the measured data. Due to the flexible programming by means of pushbuttons the flow sensor can be adapted to different conditions. The sensor is mounted via an adapter. A high protection rating and a robust compact housing distinguish the sensor in the field. fluid sensors and diagnostic systems Volumetric flow sensor for the detection of the water position sensors quantity in a filtration system. and object recognition bus, identification and control systems 38
    • Flow sensors Fluid sensors and diagnostic systemsApplications:Conductive liquids (conductivity: ≥ 20 μS/cm / viscosity: < 70 mm 2/s at 40 °C) Measuring range Pulse value Response time Accuracy Process Order flow flow flow connection no. [l/min] [s]M12-Steckverbindung · DC PNP/NPN · with display · EPDM O-rings 0...25 0.05 l...30 000 m3 < 0.150 (dAP = 0) ± (2 % MV + 0.5 % VMR) G 1/2 SM6100 0.2...50 0.1 l...50 000 m3 < 0.150 (dAP = 0) ± (2 % MV + 0.5 % VMR) G 3/4 SM7100 0.2...100 0.1 l...100 000 m3 < 0.150 (dAP = 0) ± (2 % MV + 0.5 % VMR) G1 SM8100Accessories Further technical data Type Description Order Type no. SM Adapter G 1/2 - G 3/4, pack quantity Operating voltage [V] 20...30 DC E40189 2 pcs., high-grade stainless steel Measuring range temperature [°C] -20...80 Short-circuit protection, pulsed • Reverse polarity / overload protection •/• Adapter G 1/2 - R 1/2, pack quantity E40199 Current rating [mA] 2 x 200 2 pcs., high-grade stainless steel Output function OUT1 normally open / normally closed programmable or pulse Adapter, G 3/4 - R 1/2, pack quantity E40178 OUT2 normally open / 2 pcs., high-grade stainless steel normally closed Adapter, G 1 - R 1/2, pack quantity programmable or analogue E40179 2 pcs., high-grade stainless steel (4...20 mA / 0...10 V, scalable) Grounding clamp G 1/2 E40196 Protection rating, protection class IP 67, III Grounding clamp G 3/4 E40197 Ambient temperature [°C] -10...60 Grounding clamp G 1 E40198 Medium temperature [°C] -10...70 Pressure resistance [bar] 16Connectors and splitter boxes high-grade stainless steel (316S12); Type Description Order Housing materials PBT-GF 20; PC; no. EPDM/X (Santoprene) Socket, M12, stainless steel (316S16); EVC004 Sensor material PEEK 2 m black, PUR cable (polyether-etherketone) Socket, M12, EVC005 5 m black, PUR cable Socket, M12, EVC006 10 m black, PUR cable For further technical data please go to: www.ifm.com 04.2011 39
    • product news Compressed air consumption andFluid sensors and diagnostic systems leakage monitoring. Compressed air meter with display and totalizer function. Now also with different accuracy grades. For compressed air in industrial use, argon, carbon dioxide, nitrogen. Large measuring range up to 700 Nm3/h. Larger measuring ranges on request. Fast response time and high response sensitivity. With flow rate, totalising and temperature indication. Calorimetric measuring principle The compressed air meter detects the standard volume flow directly (according to ISO 2533). This makes correc- tions, in case of temperature or pressure fluctuations, unnecessary. The high measurement dynamics of the sys- tem enable the reliable detection of even minute quan- tities, e.g. leakage. High accuracy and repeatability are ensured by the integration of the measurement sensor’s key elements into a defined pipe length. Measuring compressed air consumption in air supply lines We offer additional compressed air sensors for larger measuring ranges on request, especially for supply and air supply lines. As an option compressed air sensors with exchangeable electronics, allowing subsequent calibration under oper- ating pressure, can also be used. fluid sensors and diagnostic systems Argon consumption measurement in a position sensors laser welding system. and object recognition bus, identification and control systems 40
    • Flow sensors Fluid sensors and diagnostic systems Measuring range Pulse value Measuring accuracy Process Order connection no. [Nm3/h] [m3] [% of the final value]Application: compressed air in industrial use, air quality DIN 8573-1,class 141 (measurement error: value A) / class 344 (measurement error: value B) 0.06...15 0.001...1 000 000 A): ± (3 % MV + 0.3 % VMR) / B): ± (6 % MV + 0.6 % VMR) G 1/4 SD5000 0.25...75 0.001...1 000 000 A): ± (3 % MV + 0.3 % VMR) / B): ± (6 % MV + 0.6 % VMR) R 1/2 SD6000 0.25...75 0.001...1 000 000 ± (15 % MV + 1.5 % VMR) G 1/2 SD6050 0.75...225 0.003...3 000 000 A): ± (3 % MV + 0.3 % VMR) / B): ± (6 % MV + 0.6 % VMR) R1 SD8000 1.3...410 0.005...4 000 000 A): ± (3 % MV + 0.3 % VMR) / B): ± (6 % MV + 0.6 % VMR) R 1 1/2 SD9000 2.3...700 0.010...4 000 000 A): ± (3 % MV + 0.3 % VMR) / B): ± (6 % MV + 0.6 % VMR) R2 SD2000Larger measuring ranges on request.Application:argon (Ar), carbon dioxide (CO2), nitrogen (N2) Ar: 0.08...24.54 CO2: 0.047...14.38 0.001...1 000 000 (6% MV + 0.6% VMR) G 1/4 SD5100 N2: 0.05...14.94 Ar: 0.39...118.2 CO2: 0.24...71.7 0.001...1 000 000 (6% MV + 0.6% VMR) R 1/2 SD6100 N2: 0.24...73.0Connectors and splitter boxes Common technical data Type Description Order Type no. SD Socket, M12, Operating voltage [V] 19...30 DC EVC004 2 m black, PUR cable Current rating [mA] 2 x 250 Socket, M12, EVC005 Analogue output [mA] 4...20 5 m black, PUR cable Short-circuit protection, pulsed • Socket, M12, EVC006 Reverse polarity / overload protection •/• 10 m black, PUR cable Medium temperature [°C] 0…60 Ambient temperature [°C] 0…60 Response time [s] < 0.1 (dAP = 0) Pressure resistance [bar] 16 Protection IP65, III Connection M12 connector PBT-GF 20; PC (APEC), Makrolon; Housing materials stainless steel (304/1.4301); Viton high-grade stainless steel 316L /1.4404; ceramics; Materials glass passivated; PEEK (wetted parts) (polyetheretherketone); polyester; Viton; aluminium; anodized For further technical data please go to: www.ifm.com 11.2010 41
    • product news A breath of fresh air in pneumatics –Fluid sensors and diagnostic systems now also available as NPN switching. Compact pressure sensor for applications in robotics and handling. Slanted display for good readability and handling. Two-colour display for indication of the switching status. Easy installation using integrated mounting holes and accessories. Two programmable switching outputs or one switching and diagnostic output. Pressure range -1...1 bar or -1...10 bar. PQ pressure sensor – for pneumatic applications The new pressure sensors of the PQ series are based on a piezoresistive measuring element and are distinguished by an extremely compact housing and a wide range of pos- sible applications. The units precisely measure the pressure in the negative pressure and overpressure range in pneu- matic applications. The silicon measuring cell is insensitive to liquids (e.g. condensed water) and deposits that might occur in the system. Technical details The silicon measuring cell used guarantees a high overload resistance as well as an accuracy of ± 0.5 %. The sensor can be programmed using two pushbuttons. The two- colour, four-digit display makes the system pressure visible from a distance in normal operation. fluid sensors and diagnostic systems position sensors and object recognition bus, identification and control systems 42
    • Pressure sensors Fluid sensors and diagnostic systemsProcess connection G 1/8NPN switching Measuring range Poverload Pburst Set point Reset point Step Order Relative pressure max. min. SP1 / SP2 rP1 / rP2 increment no. [bar] [bar] [bar] [bar] [bar] [bar]M8 connector · output function 2 x programmable or 1 x + diagnosis -1...1 20 30 -0.97...1 -0.98...0.99 0.005 PQ0809 -1...10 20 30 -0.90...10 -0.95...9.95 0.05 PQ0834Mounting options Common technical dataThe sensor can be fixed to flat surfaces and profiles Type of pressure: relative pressureusing the two M4 drill holes on the front. It can be fixed to compressed aira DIN rail using the robust DIN rail clip, which is securedagainst inadvertent movement. The sensor is screwed to Operating voltage [V DC] 18...32the clip. Current rating [mA] 100Installation with an optional double nipple with 1/8" Short-circuit protection, pulsed •thread is even easier. Using this nipple, the sensor can befixed to the pipe or air-ducting plate and aligned at the Reverse polarity protection •same time – quickly and easily. Overvoltage protection up to 40 V Current consumption [mA] < 50 Accuracy / deviationAccessories (in % of the span) Switch point accuracy < ± 0.5 Type Description Order Deviation of the characteristics < ± 0.25 (BFSL) no. < ± 0.5 (LS) Hysteresis < ± 0.25 DIN rail clip with socket head screws Repeatability < ± 0.1 E37340 M4, stainless steel (1.4310/301) Long-term stability < ± 0.05 Temperature coefficients (TEMPCO) in the temperature range 0...60 °C (in % of the span per 10K) Adapter R1/8 - R 1/8, rotatable, E37350 Greatest TEMPCO of zero 0.2 nickel-plated brass Greatest TEMPCO of the span 0.2 Switching frequency [Hz] ≤ 170 Medium temperature [°C] 0...60 T pipe mounting set G1/2 with reducer, E37360 Protection IP 65, III nickel-plated brass Shock resistance 50 g Vibration resistance 20 g Connector for standard tube, PBT (Pocan), E30076 Housing materials FPM (Viton), Ø 6 mm, 4 pcs. polyester Connector for standard tube, E30077 brass, FPM (Viton), Ø 8 mm, 4 pcs. Materials (wetted parts) silicon (plated), PBT (Pocan) Connectors and splitter boxes Type Description Order no. Socket , M8, E11196 2 m black, PUR cable Socket , M8, E11197 5 m black, PUR cable Socket , M8, E11199 2 m black, PUR cable Socket , M8, E11200 5 m black, PUR cable For further technical data please go to: www.ifm.com 04.2011 43
    • product news IO-Link memory plug –Fluid sensors and diagnostic systems data storage in miniature format. Quick and easy parameter setting of IO-Link sensors. Conveniently copy and store sensor data. Universal use for IO-Link sensors. Re-writable as often as desired. ecolink M12 connectors. Application The memory plug is used where sensor data are to be copied or stored. This could for instance be the case when a defective unit needs to be replaced or several sensors with the same parameter settings are installed. The memory plug reads and stores the data from a con- nected IO-Link sensor. If the user then connects a sensor of the same type with factory settings, the data record stored on the memory plug will be copied onto the new sensor. Advantages The use of the memory plug saves time that would other- wise be needed for re-programming the sensor. Moreover, by copying the data, errors during re-parameterisation are avoided. fluid sensors and diagnostic systems position sensors and object recognition bus, identification and control systems 44
    • Pressure sensors Fluid sensors and diagnostic systemsFunctionality IO-Link memory plug E30398The memory plug allows easy storing or copying of para-meters via an automatic parameter exchange. To do so, Operating voltage [V DC] 18...32the memory plug is inserted in the supply and switching Current rating [mA] 2000output cable of a device. During power-on or when con- According to thenecting a device to the supplied memory plug, the data Short-circuit protection connected sensorexchange is automatically carried out. Reverse polarity protection •If the memory plug is empty it automatically stores the Overload protected According to thedata of a connected sensor, including type. connected sensor Voltage drop [V] < 0.5Then the stored data can be transferred to as many sen-sors of the same type (= same device ID) as desired. Current consumption [mA] < 20 Ambient temperature [°C] -25...80Furthermore, you can write-protect the memory plug or Protection IP 67remove this write protection via the FDT container. Inaddition, you can write on and block the memory plug PA, PET, High-grade stainless steelvia the FDT container. Housing materials (316L/1.4404), TPU, FPM (Viton)Even without a PC the write protection can be activatedor deactivated and the factory setting restored by means Accessoriesof the teach button, available as an accessory. Type Description OrderDimensions no. 25 M12x1 18 Power supply 24 V DC E30080 LED Helpful when copying data to / from sensors in the laboratory or office 52 22 IO-Link interface, current consumption E30396 from USB port M12x1 21) Connection for voltage supply and output signals M12 connection cable, EVC0102) Connection for sensor 0.3 m black, PUR cable M12 connection cable,Wiring diagram EVC013 2 m black, PUR cable 1 1 1 BN Teach button E30405 L+ 2 2 2 WH Out 2 1 4 4 2 4 BK Out 1 3 3 3 BU L For further technical data please go to: www.ifm.com 11.2010 45
    • product news The first fully electronicFluid sensors and diagnostic systems contact manometer... ...now also with G 1/2 manometer connection and additional measuring ranges. Optimum readability and electronic pointer display mean reliable operation. Rotatable display with LED bargraph for switch point indication. Output functions programmable via LED display and optical touch fields. G 1/2 manometer connection or flush G1 process connection. Additional pressure ranges: 100 bar, 250 bar, 400 bar. Electronic “contact manometer” PG In many industrial areas mechanical contact manometers are often used because of their highly visible display. The electronic “contact manometer” of the series PG combines the high visibility of a manometer display with the advan- tages of an electronic pressure sensor, for example the programmable switching and analogue output (scalable), the high overload protection as well as the integrated temperature compensation. The LED bargraph shows set and reset points, trends and the limits of dynamic pressure fluctuations, if any. The pointer is controlled via a stepping motor as it is has been tried and tested many times in cars (tachometer). When disconnected, the pointer is not visible. fluid sensors and diagnostic systems position sensors and object recognition bus, identification and control systems 46
    • Pressure sensors Fluid sensors and diagnostic systemsManometer with G 1/2 process connectionMeasuring range Extended Poverload Analogue Analogue Set point Reset point OrderRelative pressure display range max. start point end point SP1 rP1 no. [bar] [bar] [bar] [bar] [bar] [bar] [bar]Output function PNP/NPN programmable + analogue output programmable 0...400 600 800 0.0...500.0 100.0...600.0 2.0...600.0 0.0...598.0 PG2450 0...250 400 600 0.0...350.0 50.0...400.0 1.0...400.0 0.0...399.0 PG2451 0...100 160 300 0.0...135.0 25.0...160.0 0.4...160.0 0.0...159.6 PG2452 -1...25 40 100 -1.00...33.75 5.25...40.00 -0.90...40.00 -1.00...39.90 PG2453 -1...10 16 50 -1.00...13.50 1.50...16.00 -0.96...16.00 -1.00...15.96 PG2454 -1...4 6.4 30 -1.00...5.40 0.00...6.40 -0.98...6.40 -1.00...6.38 PG2455 -0.125...2.5 4 20 -0.125...3.350 0.525...4.000 -0.115...4.000 -0.125...3.990 PG2456 -0.05...1 1.6 10 -0.050...1.340 0.200...1.600 -0.046...1.600 -0.050...1.596 PG2457 -0.0125...0.25 0.4 10 -0.0125...0.3375 0.05...0.4 -0.0115...0.4 -0.0125...0.399 PG2458 -0.005...0.1 0.16 4 -0.005...0.135 0.02...0.16 -0.0046...0.16 -0.005...0.1596 PG2489 -1...1 1.6 10 -1.0...1.1 -0.5...1.6 -0.992...1.6 -1...1.592 PG2409Flush manometer with G1 Aseptoflex Vario process connectionMeasuring range Extended Poverload Analogue Analogue Set point Reset point OrderRelative pressure display range max. start point end point SP1 rP1 no. [bar] [bar] [bar] [bar] [bar] [bar] [bar]Output function PNP/NPN programmable + analogue output programmable -1...25 40 100 -1.00...33.76 5.24...40.00 -0.96...40.00 -1.00...39.96 PG2793 -1...10 16 50 -1.0...13.50 1.5...16.00 -0.98...16.00 -1.00...15.98 PG2794 -1...4 6.4 30 -1.00...5.40 0.00...6.40 -0.99...6.40 -1.00...6.39 PG2795 -0.124...2.5 4 20 -0.124...3.370 0.500...4.000 -0.120...4.000 -0.124...3.996 PG2796 -0.05...1 1.6 10 -0.05...1.35 0.2...1.60 -0.048...1.60 -0.05...1.598 PG2797 -0.0124...0.25 0.4 10 -0.0124...0.3376 0.05...0.40 -0.012...0.40 -0.0124...0.3996 PG2798 -1...1 1.6 10 -1...1.1 -0.5...1.6 -0.998...1.6 -1...1.598 PG2799 -0.005...0.1 0.16 4 -0.005...0.135 0.02...0.16 -0.0048...0.16 -0.005...0.1598 PG2789Programming options: hysteresis / window, NO / NC, switching logic, current output, damping, adaptation of displayed values,PG27xx, PG24xx display unit, 2-point calibrationThe electronic “contact manometer” offers Common technical datathe following advantages: Type of pressure: relative pressure• 3 units in one: analogue display, transmitter Liquids and gases and switch – without using relays or switching amplifiers. Operating voltage [V DC] 18...32• Higher accuracy by electronic processing of Current rating [mA] 250 measured values Current consumption [mA] < 70 (24 V)• Parameterisable functions (switch points, NC / NO, Accuracy / deviation PG27xx PG24xx hysteresis etc.) facilitate the selection of units and (in % of the span) turn down 1:1 reduce the variety of types Deviation of the switch point* < ± 0.2 < ± 0.5• Easy specification of the right “manometer” Deviation of the characteristics* < ± 0.2 < ± 0.5• Rotatable display PG27xx PG24xx• High-quality ceramic measuring cell with Medium temperature [°C] -25...125 -25...80 (145 max. 1 h) improved process adapter high-grade stainless steel• Excellent overload protection Housing materials 316L /1.4404; PTFE, FPM (Viton),• Excellent vibration and shock resistance PA,laminated safety glass (no filling for vibration absorber or pressure PG27xx: high-grade stainless steel transfer necessary) 316L /1.4435, PTFE, Materials (wetted parts) ceramics (99.9 % Al2O3)• Burst-resistant viewing glass PG24xx: high-grade stainless steel• Wear-free, even in case of dynamic load changes 316L /1.4404, FPM, ceramics (Al2O3)• Low weight (no mechanics) * for PG2789: < ± 0.5 % / for PG2450, PG2451, PG2489: < ± 0.6 % For further technical data please go to: www.ifm.com 11.2010 47
    • product news Electronic manometer PG, withFluid sensors and diagnostic systems alternative process connection. Now available with conical G1 process connection. Optimum legibility due to the electronic pointer display. Rotatable display with LED bargraph for switch point indication. Optionally trend display or min /max display via the LED bargraph. Output functions programmable via LED display and optical touch fields. Hygienic flush design and high total accuracy (0.2 %). Variable process connection for the manometer In addition to the electronic contact manometers with Aseptoflex Vario process connection for hygienic appli- cations or G 1/2 process connection for hydraulic appli- cations available, units with conical G 1 thread are now available. This process connection also allows flush in- stallation using the available adapters. It can also be used for hygienic applications. In existing plants it is even easier to exchange the units. All further technical data as well as the characteristics of the measuring cell correspond to that of the PG27 ma- nometer with Aseptoflex Vario thread. fluid sensors and diagnostic systems Pressure monitoring in pipes. position sensors and object recognition bus, identification and control systems 48
    • Pressure sensors Fluid sensors and diagnostic systemsFlush manometer with G 1 process connectionMeasuring range Extended Poverload Analogue Analogue Set point Reset point OrderRelative pressure display range max. start point end point SP1 rP1 no. [bar] [bar] [bar] [bar] [bar] [bar] [bar]Output function PNP/NPN programmable + analogue output programmable -1...25 40 100 -1.00...33.76 5.24...40.00 -0.96...40.00 -1.00...39.96 PG2893 -1...10 16 50 -1.0...13.50 1.5...16.00 -0.98...16.00 -1.00...15.98 PG2894 -1...4 6.4 30 -1.00...5.40 0.00...6.40 -0.990...6.40 -1.000...6.39 PG2895 -0.124...2.5 4 20 -0.124...3.370 0.500...4.000 -0.120...4.000 -0.124...3.996 PG2896 -0.05...1 1.6 10 -0.05...1.35 0.2...1.60 -0.048...1.60 -0.05...1.598 PG2897 -0.0124...0.25 0.4 10 -0.0124...0.3376 0.05...0.40 -0.012...0.40 -0.0124...0.3996 PG2898 -1...1 1.6 10 -1...1.1 -0.5...1.6 -0.998...1.6 -1...1.598 PG2899 -0.005...0.1 0.16 4 -0.005...0.135 0.02...0.16 -0.0048...0.16 -0.005...0.1598 PG2889The electronic “contact manometer” offers Common technical datathe following advantages: Type of pressure: relative pressure• 3 units in one: analogue display, transmitter Liquids and gases and switch – without using relays or switching amplifiers. Operating voltage [V DC] 18...32• Higher accuracy by electronic processing of Current rating [mA] 250 measured values Current consumption [mA] < 70• Parameterisable functions (switch points, NC / NO, hysteresis / window, hysteresis etc.) facilitate the selection of units and NO / NC, switching logic, reduce the variety of types current output, damping, Programming options adaptation of displayed• Easy specification of the right “manometer” values,• Rotatable display scalable, display unit, 2-point calibration• High-quality ceramic measuring cell with G 1 process connection Accuracy / deviation PG289x PG2889 (in % of the span) turn down 1:1• Excellent overload protection Deviation of the switch point < ± 0.2 < ± 0.5• Excellent vibration and shock resistance Deviation of the characteristics < ± 0.2 < ± 0.5 (no filling for vibration absorber or pressure Linearity < ± 0.15 < ± 0.25 transfer necessary) Hysteresis < ± 0.15 < ± 0.2 Repeatability < ± 0.1 < ± 0.1• Burst-resistant viewing glass Long-term stability < ± 0.1 < ± 0.1• Wear-free, even in case of dynamic load changes Temperature coefficients (TEMPCO) in the temperature range 0...70 °C• Low weight (no mechanics) (in % of the span per 10 K)Accessories Greatest TEMPCO of zero < ± 0.05 < ± 0.1 Greatest TEMPCO of the span < ± 0.15 < ± 0.2 Type Description Order -25...125 Medium temperature [°C] no. (145 max. 1 h) high-grade stainless steel Adapter G 1 316L /1.4404; E33601 Housing materials for Clamp 1-1.5" PTFE, FPM (Viton), PA, laminated safety glass high-grade stainless steel 316L /1.4435; Adapter G 1 Materials (wetted parts) E33612 ceramics (99.9 % Al2O3); for DIN11851 DN40 (1.5") PTFE Connectors and splitter boxes Adapter G 1 E33622 Type Description Order for Varivent type N (D68) no. Socket, M12, 4-pole EVT004 5 m orange, PVC cable Welding adapter G 1 E30013 Socket, M12, 4-pole EVT005 10 m orange, PVC cable Welding adapter G 1 with O-ring E30072 For further technical data please go to: www.ifm.com 11.2010 49
    • product news Hydrostatic level measurementFluid sensors and diagnostic systems in hazardous areas. New submersible pressure transmitter with ATEX, IECEx and GL approval. ATEX approval for group I, category M1 and group II, category 1G and 1D. GL approval to environmental category C, F, EMC 1. Longitudinal water resistance: no water penetrates in transmitter if cable damaged. High resistance due to stainless steel housing and FEP cable. Good overall accuracy and long-term stability. Application areas The ATEX submersible pressure transmitters of the PS3 series are designed for level measurement in areas subject to explosion hazard like tanks, containers, wells, streaming water, drill holes or wastewater plants. The sensors can be used in zone 0, 1, 2 or zone 20, 21, 22 as well as in mining. The GL approval allows an appli- cation in the maritime sector. Advantages The analogue output signal and the use of the two-wire technology allow easy integration in the applications. Voltage is supplied to the transmitter via an intrinsically safe supply isolator or a zener diode barrier. fluid sensors and diagnostic systems Tank level measurement in hazardous areas. position sensors and object recognition bus, identification and control systems 50
    • Pressure sensors Fluid sensors and diagnostic systems2-wire connection technologyMeasuring range up to 1 bar Measuring range Overload pressure Bursting pressure Cable length Protection Order Relative pressure no. [bar] [bar] [bar] [m]Analogue output 4...20 mA 0...0.25 2 2.4 5 IP 68 PS308A 0...0.6 4 4.8 10 IP 68 PS307A 0...1 5 6 15 IP 68 PS317ADimensions Common technical data 147 Operating voltage [V DC] 10...30 Output signal [mA] 4...20 27 Accuracy in % of the span Accuracy ≤ 0.5 (incl. non-linearity, hysteresis) Non-linearity ≤ 0.2Wiring diagram Long-term stability per year ≤ 0.2 Temperature coefficients (TEMPCO) BN (in % of the span per 10 K) L+ GN Temperature coefficient of zero typ. 0.2 L Temperature coefficient of the span typ. 0.2 BU 1 Ambient temperature / T6: -30...60 Medium temperature [°C] T5: -30...801) Screen (connected to the housing) 1G, 1/2G, 2G T4: -30...105 Ambient temperature / -30...40 (750 mW)Accessories Medium temperature [°C] -30...70 (650 mW) 1D, 1/2D, 2D -30...100 (550 mW) Type Description Order no. Compensated temperature range [°C] 0...50 Weight [kg] 0.2 (+ 0.08 per m of cable) Materials Housing high-grade stainless steel Additional weight for the PS3 series, (316Ti / 1.4571) E30402 approx. 500 g Diaphragm high-grade stainless steel (316Ti / 1.4571) Protective cover high-grade stainless steel (316Ti / 1.4571) Cable FEP Pull force [N] 500 Application The ATEX submersible pressure transmitters of the PS3 series are designed for numerous applications. The trans- mitters are of high resistance due to their housing, sensor diaphragm and cover cap made of stainless steel. There- fore it is no problem to use them in different media. The available pressure ranges enable measurement of filling levels of up to ten metres of water column. The ATEX, IECEx and GL approvals allow the use of the transmitters in potentially explosive atmospheres as well as on ships. The pressure transmitters are supplied with fixed cables at no extra cost, lengths available are 5 m, 10 m or 15 m. For further technical data please go to: www.ifm.com 11.2010 51
    • product news For fast temperature changes.Fluid sensors and diagnostic systems New Pt100 sensors for industrial applications. Ideal response times of T05 = 1 s and T09 = 3 s. Probe diameter of 6 mm or 8.2 mm for TM9900 (titanium measuring probe). Robust stainless steel housing with IP 68 and IP 69K protection ratings. High pressure resistance for different application areas. Precise temperature measurement using a Pt100 sensor element, class A. Long lasting precision The probe sensors ensure very precise temperature measurement using a Pt100 element of precision class A. The high protection ratings IP 68 / IP 69K and the high- grade stainless steel housing guarantee long life of the sensors. Even faster response times Using the latest technologies and a very thin sensor tip, the response time is extremely fast. A wide range of applications These new types complete the existing product range and can be used in many applications. fluid sensors and diagnostic systems Probe sensor with connected TR control monitor. position sensors and object recognition bus, identification and control systems 52
    • Temperature sensors Fluid sensors and diagnostic systemsProbe sensors TT Technical data TM, TT TM9900 Type Nominal length Order L [mm] no. ± (0.15 K + ± (0.3 K + Precision [%] 0.002 x ItI) 0.005 x ItI)Pt100, 6 mm Measuring element Class A Class B 50 TT9281 Pt100 to DIN EN 60571 100 TT0281 Measuring range [°C] -50...150 -40...125 150 TT1281 Nominal pressure [bar] (The fitting used determines the 160 300 250 TT2281 permissible operating pressure.) 350 TT3281 Protection IP 68 / IP 69K high-gradeProbe sensors TM4 stainless Material titanium steel (316L / Type Nominal length Order 1.4404) L [mm] no. Dynamic response time T05 / T90 [s] 1/3Pt100, 6 mm, G 1/2 Control monitor 50 TM4411 100 TM4431 Description Order no. 150 TM4441 250 TM4461 Control monitor, TR2432 1 x analogue output, 1 x PNP/NPNPt100, 6 mm, 1/2" NPT Control monitor, TR7432 50 TM4311 2 x PNP/NPN 100 TM4331 Measured signal converter, TP3237 Pt100 / Pt1000 in 4...20 mA, scaling 0...100 °C 150 TM4341 250 TM4361 AccessoriesProbe sensor titanium M18 x 1.5 Type Description Order no. Type Nominal length Order L [mm] no. Mounting set, connection of TT sensors E30017 to TR, stainless steel (303 / 1.4305)Pt100, 8.2 mm, M18 x 1.5 44 TM9900 Clamp fitting G 1/2, 6/8/10 mm, E30018 stainless steel (303 / 1.4305), FPM (Viton) Clamp fitting 1/2" NPT, 6/8/10 mm, E30025 stainless steel (303 / 1.4305); FPM (Viton)Connectors and splitter boxes Progressive ring fitting G 1/2, 6 mm, high- E30047 grade stainless steel (316Ti / 1.4571) Type Description Order no. Socket, M12, Progressive ring fitting 1/2" NPT, 6 mm, EVC004 E30049 2 m black, PUR cable high-grade stainless steel (316Ti / 1.4571) Socket, M12, EVC005 5 m black, PUR cable M12 jumper Progressive ring fitting G 1/4, 6 mm, high- EVC013 E33431 2 m black, PUR cable grade stainless steel (316Ti / 1.4571) M12 jumper EVC014 5 m black, PUR cable Welding adapter, 24.7 mm, clamp adapter, E30108 high-grade stainless steel (316L / 1.4404) Adapter G 1/2 for TM9900, E40114 Titanium Adapter G 1/4 for TM9900, E40115 Titanium For further technical data please go to: www.ifm.com 04.2011 53
    • product news New additions to temperatureFluid sensors and diagnostic systems probe range. Hygienic Pt100 sensors with 4-wire connection. As probe sensor or with integrated Tri-Clamp process connection. Probe diameter 6 mm. Robust stainless steel housing with IP 68 and IP 69K protection ratings. High pressure resistance for different application areas. Precise temperature measurement using a Pt100 sensor element, class A. Process connection Easy adaptation: The types TM48 and TM49 need no separate, hygienic process adapter. They are directly fitted with a 1...1.5" or a 2" clamp process connection. The TTx291 version can be easily fixed using clamp fittings. Fast response time The 6 mm thin sensor tip guarantees an excellent re- sponse time of T05 = 1 s and T09 = 3 s while ensuring high stability. For hygienic areas The sensor is perfectly fitted for use in hygienic applica- tions thanks to its high protection rating of IP 68 / IP 69 K and surface definition. fluid sensors and diagnostic systems Temperature measurement in beverage tanks. position sensors and object recognition bus, identification and control systems 54
    • Temperature sensors Fluid sensors and diagnostic systemsSensors with clamp process connection Common technical data Type Nominal length Order L no. Precision [%] ± (0.15 K + 0.002 x ItI) [mm] Pt100 to DIN EN 60571 Measuring element Class APt100, 6 mm, Clamp 1...1.5" Measuring range [°C] -50...150 30 TM4801 Nominal pressure [bar] 50 TM4811 160 (The fitting used determines the 100 TM4831 permissible operating pressure.) 150 TM4841 Protection IP 68 / IP 69K high-grade stainless steel Material (316L/1.4404)Pt100, 6 mm, Clamp 2" Dynamic response time T05 / T90 [s] 1/3 30 TM4901 50 TM4911 Control monitor 100 TM4931 Description Order 150 TM4941 no. Control monitor, TR2432 1 x analogue output, 1 x PNP/NPNProbe sensors Control monitor, TR7432 Type Nominal length Order 2 x PNP/NPN L no. Measured signal converter, [mm] TP3237 Pt100 / Pt1000 in 4...20 mA, scaling 0...100 °CPt100, 6 mm Accessories 50 TT9291 Type Description Order 100 TT0291 no. 150 TT1291 Mounting set, connection of TT sensors 250 TT2291 E30017 to TR, stainless steel (303 / 1.4305) 350 TT3291Connectors and splitter boxes Welding adapter, 24.7 mm, E30407 Type Description Order clamp fitting, PEEK sealing no. Socket, M12, EVT067 2 m orange PVC cable Socket, M12, EVT004 5 m orange PVC cable M12 jumper, EVT043 2 m orange, PVC cable M12 jumper, EVT044 5 m orange, PVC cable For further technical data please go to: www.ifm.com 04.2011 55
    • product news Head transmitter – a thing of the past.Fluid sensors and diagnostic systems Temperature plug – the future. Type TP: Modular transmitter – great benefit. Small, light housing with M12 connections. Reduced mounting complexity and error sources. Scalable Pt100 / Pt1000 evaluation from -50...300 °C. Status LED signals the operating status. Full potting and ecolink M12 technology guarantee high vibration resistance. Minimised installation and error sources. Because of the use of two standardised M12 connec- tions, the installation complexity of the TP temperature plug is reduced to a minimum as compared to a common head / DIN rail transmitter. Furthermore, error sources such as cable clamps are eliminated. Versatile use. Thanks to 4-wire Pt100 / Pt1000 evaluation, the trans- mitter can also be connected to a Pt element using con- nection cables. Due to its small size, it is also suited for harsh applications, because it can be installed in a safe position. In addition the scalability of the TP between -50...300 °C, using the USB interface E30396 allows individual adapta tion of the measuring range to almost any application. fluid sensors and diagnostic systems position sensors and object recognition bus, identification and control systems 56
    • Temperature sensors Fluid sensors and diagnostic systems Factory setting measuring range Order Accessories sensors (extract) (Measuring range scalable) no. Description OrderM12 connections • output function 4...20 mA / IO-link no. -50...300 °C TP3232 Probe sensors 0...100 °C TP3237 Pt100 probe sensor, Ø 10 mm, L = 160 mm TT1081 -50...150 °C TP3231 Pt100 probe sensor, Ø 10 mm, L = 260 mm TT2081 0...300 °F TP3233 Pt100 probe sensor, Ø 10 mm, L = 360 mm TT3081 Pt100 probe sensor, Ø 10 mm, L = 560 mm TT5081 Common technical data TP temperature plug Cable sensorsOperating voltage [V DC] 20...32 Pt100 bolt-on sensor for M6, 32 x 12 TS2229Ambient temperature [°C] -25...70 Pt100 cable sensor, Ø 10 mm, 2 m cable TS2056Max. measuring range (4...20 mA) [°C] -50...300 Pt100 cable sensor, Ø 6 mm, 2 m cable TS2256Accuracy via: Pt100 screw-in sensor, M6, 2 m cable TS2659IO-Link ± 0.3 K AccessoriesAnalogue output ± 0.3 K + (± 0.1 %) of the scaled span Type Description OrderTemperature coefficient no. < 0.1 %(in % of the span per 10 K)Vibration resistance 20 g USB IO-Link interface E303964-wire evaluation •Pt100 and Pt1000 PA PACM 12Housing material (TROGAMID); PET; seal: FPM (Viton) Sockets (extract) high-grade stainless steel Type Description OrderMaterial coupling nut (1.44.04) no.Protection IP 67, III Socket, M12, EVT067Dimensions 2 m orange, PVC cable Socket, M12, EVT004 5 m orange, PVC cable 25 M12x1 18 Socket, M12, EVC004 2 m black, PUR cable LED Socket, M12, EVC005 5 m black, PUR cable 52 22 Connection cables (extract) M12x1 2 Type Description Order no.1) Connection for voltage supply and output signals2) Connection for temperature sensor Connection cable, M12, EVT043 2 m orange, PVC cableWiring diagram 1 Connection cable, M12, B 2 EVT050 5 m orange, PVC cable 1 3 B 4 1 L+ 3 2 L TP 4 4 Connection cable, M12, IO-Link EVC013 1 3 2 m black, PUR cable 2 L 2 3 4 Connection cable, M12, EVC034 5 m black, PUR cable1) Two-wire sensor2) Four-wire sensor3) Operation as 2-wire temperature transmitter4) Operation as 3-wire unit, IO-Link communication possibleB) Link For further technical data please go to: www.ifm.com 11.2010 57
    • product news Pt100 / Pt1000 bolt-on andFluid sensors and diagnostic systems screw-in sensors. Pt100 / Pt1000 bolt-on sensors for different applications. Flexible mounting Bolt-on sensors for M6 and M10 screws. Screw-in sensors in M5 and M6. Temperature measurement of -30...180 °C. For complex applications with different requirements Every application has its own requirements as regards the temperature sensors to be used. Criteria such as housing material or mechanical design are as important as the connection to control monitors, plcs or AS-i modules. The housings and materials of the new screw-in and bolt-on sensors of ifm electronic have been designed for a wide range of applications. TS522A and TS502A for ATEX applications In addition, the bolt-on sensors TS522A and TS502A have the ATEX approval to group II, category 3D / 3G. fluid sensors and diagnostic systems position sensors and object recognition bus, identification and control systems 58
    • Temperature sensors Fluid sensors and diagnostic systems Measuring Type Housing material Cable material, Connection Measuring ATEX Order range cable length element category no. [°C] [m]Bolt-on sensors 12 x 32 Stainless steel -25...90 PUR, 2 M12 Pt100 – TS2229 for M6 305 / 308 /1.4303* 10 x 10 x 42 high-grade stainless steel 4-wire -20...115 silicone, 5 Pt100 II 3D / 3G TS522A for M6 316L /1.4404 wirable 10 x 18 x 48 high-grade stainless steel 4-wire -20...115 silicone, 5 Pt1000 II 3D / 3G TS502A for M10 320S17/1.4571 wirable* Sensor housing, bolt-on sensor: nickel-plated CuScrew-in sensors high-grade stainless steel -30...180 M6 silicone, 2 M12 Pt100 – TS2659 316L /1.4404 high-grade stainless steel -30...180 M5 silicone, 10 M12 Pt100 – TS0759 316L /1.4404 high-grade stainless steel -30...180 M5 silicone, 2 M12 Pt100 – TS2759 316L /1.4404 high-grade stainless steel 4-wire -30...180 M5 silicone, 4 Pt100 – TS4759 316L /1.4404 wirable high-grade stainless steel -30...90 M5 PUR, 2 M12 Pt100 – TS2789 316L /1.4404Dimensions Control monitor 51 Example TS2229 Description Order 14 35 no. M12 x1 Control monitor, 12 TR2432 49,5 6,5 1 x analogue output, 1 x PNP/NPN Control monitor, 1,8 8,7 TR7432 2 x PNP/NPN 17 Measured signal converter, TP3237 Pt100 / Pt1000 in 4...20 mA, scaling 0...100 °C Measured signal converter, TP3231 Example TS2759 Pt100 / Pt1000 in 4...20 mA, scaling -50...150 °C Measured signal converter, TP3232 25,7 Pt100 / Pt1000 in 4...20 mA, scaling -50...300 °C 58 8 Measured signal converter, M5 4 TP3233 M12 x1 Pt100 / Pt1000 in 4...20 mA, scaling 0...300 °F 5,4 8 Connection cables (extract) Type Description Order no.Sockets (extract) M12 jumper, Type Description Order EVT043 2 m orange, PVC cable no. Socket, M12, EVT067 2 m orange, PVC cable M12 jumper, EVT050 Socket, M12, 5 m orange, PVC cable EVT004 5 m orange, PVC cable Socket, M12, EVC004 2 m black, PUR cable M12 jumper, EVC013 Socket, M12, 2 m black, PUR cable EVC005 5 m black, PUR cable M12 jumper, EVC034 5 m black, PUR cable For further technical data please go to: www.ifm.com 11.2010 59
    • product news The interface for automation tech-Fluid sensors and diagnostic systems nology: the OPC server software. OPC server software for Multicode Reader and diagnostic electronics VSE. Simple data integration using standard OPC interface. Supports OPC specifications Data Access 1, 2, 3 and OPC XML-DA Windows. Supports namespace browsing. Optional: OPC-Tunnel avoids time consuming network configuration and OPC Store and Forward in case of network errors. The ifm OPC server software provides a software inter- face which standardises the data from the ifm electronic diagnostic electronics VSE and the Multicode Reader for integration into a higher level system. The software licenses are divided into four levels and are dependant on the number of networked units. Different OPC client programmes process the available OPC data enabling a wide variety of user scenarios. Using the diagnostic electronics VSE it is possible to ex- port and describe vibration characteristics and monitor- ing parameters, previously set using a configuration soft- ware, such as switch points, trigger and speed signals. For the Multicode Reader the OPC server also offers standardized access to decoded reading results and vari- ous parameters. fluid sensors and diagnostic systems Example of an OPC-based monitoring software. position sensors and object recognition bus, identification and control systems 60
    • Diagnostic systems Fluid sensors and diagnostic systemsSystem requirements Products PC with Pentium III or higher Description Order Microsoft Windows 2000 / XP / 2003 / Vista / 2008 / no. Windows 7 with current service packs (Version November 2010) OPC server software for diagnostic electronics VSE 1 GB RAM (for Vista and Windows 7) 256 MB free disk space OPC server software for 25 units VOS001 Ethernet 10 / 100 / 1000 MBit /s OPC server software for 50 units VOS002 OPC server software for 75 units VOS003Licensing OPC server software for 100 units VOS004 To license the OPC server software please register on- line following the instructions in the License Manager Diagnostic electronics VSE, supported by OPC server software. (using the order ID). A test version is available from our website. Diagnostic electronics for vibration sensors VSE002 VSE Diagnostic electronicsOptional accessories for vibration sensors VSE100 VSE Description Order no. OPC server softwareOPC tunnel software to create connection between for Multicode Readerthe ifm electronic OPC server and CMSpro software OPC server software for 25 units E2I210avoiding time consuming DCOM configuration.Including OPC Store & Forward, extension module VOS099 OPC server software for 50 units E2I211with buffer function in case of connection failure, OPC server software for 75 units E2I212for use with diagnostic electronics VSE andMulticode Reader (maximum 10,000 datapoints). OPC server software for 100 units E2I213 Multicode Reader, supported by OPC server software. O2I100 O2I104 Multicode Reader O2I101 O2I103System architecture main and planning level Enterprise Ressource Planning System e.g. SAP PM visualisation software e.g. CMSpro optional data acquisition visualisation software OPC server e.g. CMSpro interface software VSExxx => VOS001...4 O2Ixxx => E2I210...3 data server sensor level diagnostic electronics Multicode Reader VSExxx O2Ixxx For further technical data please go to: www.ifm.com 04.2011 61
    • product news ContinuousFluid sensors and diagnostic systems vibration monitoring. Vibration transmitter in stainless steel housing. Continuous vibration monitoring according to ISO 10816. 2-wire loop powered. 4...20 mA signal output. True rms monitoring of the overall velocity. Robust metal housing provides high protection rating. The sensor The vibration transmitter type VT monitors machinery and equipment according to ISO 10816. The sensor mea- sures the true rms velocity of non-rotating component surfaces. The values are then transmitted as an analogue signal (4...20 mA) directly to the PLC. The applications Due to its robust design, high IP Rating as well as the maximum ambient temperature of 105 °C the sensor is suitable for use in harsh environments. The installation The unit is quick and easy to install. No extra parameter software is required. fluid sensors and diagnostic systems Overall vibration monitoring of rotating equipment position sensors such as fans, centrifuges etc. and object recognition bus, identification and control systems 62
    • Diagnostic systems Fluid sensors and diagnostic systemsVibration transmitter VTOverall vibration monitoring of machinery and equipment according to ISO 10816.M12 connector.Dimensions Technical data Vibration transmitter 22 VTV122 M12 x1 Operating voltage [V] 9.6…32 DC Analogue output [mA] 4...20 63,25 max. (Ub - 9.6 V) x 50; Load for analogue output [Ω] 720 at Ub = 24 V Protection IP 68 / IP 69K, III Ambient temperature [°C] -30...105 22 stainless steel Housing material 316L / 1.44041) tightening torque 8 Nm2) customer specific connection configuration Shock resistance [g] 400 Frequency range [Hz] 10...1000Wiring diagram Accuracy [%] <±3 Repeatability [%] < 0.5 1 L+ Non-linearity (in % of the span) < ± 0.25 4 mA = 0 mm/s; 2 Measuring range [mm/s] L 20 mA = 25 mm/s Vibration velocity Measurand rms Connection M12 connector Connectors and splitter boxes (to be ordered separately) Type Description Order no. Socket, M12, 5-pole, EVT010 5 m orange, PVC cable Socket, M12, 5-pole, EVT011 10 m orange, PVC cable Socket, M12, 5-pole, EVT012 25 m orange, PVC cable Socket, M12, 4-pole, EVM002 5 m black, PUR cable Socket, M12, 4-pole, EVM003 10 m black, PUR cable Please note permissible temperature range For further technical data please go to: www.ifm.com 11.2010 63
    • product news ecolink M8 – the safe connectionConnection technology even in difficult applications. For hygienic and wet areas. Innovative profiled sealing ring for highest protection ratings. Optimum sealing even when mounted without tools. Connection technology meets the M8 standard (EN 61076). High-quality materials for a high plant uptime. Approval for UL /CSA in preparation. ecolink M8 for demanding applications Most applications require special solutions. Only high- quality materials, assured production processes and fault- less assembly lead to success in the long run. The innovative profiled sealing ring seals radially as well as axially, providing a high protection rating. No tools needed for installation and removal. The asymmetrically acting vibration protection holds the coupling nut tight in its position, ensuring an optimum and permanent seal. High-quality materials especially adapted to the applica- tion and intensive monitoring during and after produc- tion guarantee maximum quality standards. fluid sensors and diagnostic systems ecolink – position sensors a new dimension in connection technology. and object recognition bus, identification and control systems 64
    • Connection technology Connection technologyApplications:For hygienic and wet areas in the food industry.Technical data: Operating voltage: Type Description Order Description Order without LED 50 V AC / 60 V DC no. no. with LED 10...36 V DC Nominal current: 3 A Connection cable, M8, 3 poles Protection rating: IP 67, IP 68 and IP 69K 0.3 m EVT142 2m EVT145 in locked condition with the matching counterpart. 0.6 m EVT143 5m EVT146 Tightening torque connector: 0.3...0.5 Nm 1.0 m EVT144 10 m EVT147 adhere to the maximum value of the counterpart 0.3 m EVT148 2m EVT151 Tightening torque socket: 0.3...0.5 Nm 0.6 m EVT149 5m EVT152 Ambient temperature: -25...80 °C 1.0 m EVT150 10 m EVT153 Vibration / shock: 750 g, 1 million cycles 0.3 m, LED EVT154 2 m, LED EVT157Materials: 0.6 m, LED EVT155 5 m, LED EVT158 Housing / moulded body: PVC 1.0 m, LED EVT156 10 m, LED EVT159 Contact carrier: socket PA 6.6, connector PPS 0.3 m EVT160 2m EVT163 Coupling nut: high-grade stainless steel (316L/1.4404) 0.6 m EVT161 5m EVT164 Contacts: gold-plated 1.0 m EVT162 10 m EVT165 Sealing ring: EPDM 0.3 m EVT166 2m EVT169 3-pole cable: PVC, 3 x 0.34 mm 2, Ø 4.9 mm 4-pole: PVC, 4 x 0.34 mm 2, Ø 4.9 mm 0.6 m EVT167 5m EVT170 1.0 m EVT168 10 m EVT171Approvals: cRUus in preparation 0.3 m, LED EVT172 2 m, LED EVT175 0.6 m, LED EVT173 5 m, LED EVT176 1.0 m, LED EVT174 10 m, LED EVT177 Type Description Order no. Order no. Connection cable, M8, 4 poles old NEW 0.3 m EVT178 2m EVT181Socket, M8, 3 poles 0.6 m EVT179 5m EVT182 2m – EVT122 1.0 m EVT180 10 m EVT183 5m E11495 EVT123 0.3 m EVT184 2m EVT187 10 m E11496 EVT124 25 m E11497 EVT125 0.6 m EVT185 5m EVT188 2m – EVT126 1.0 m EVT186 10 m EVT189 5m E11498 EVT127 0.3 m EVT190 2m EVT193 10 m E11499 EVT128 25 m E11500 EVT129 0.6 m EVT191 5m EVT194 2 m, LED – EVT130 1.0 m EVT192 10 m EVT195 5 m, LED E11501 EVT131 0.3 m EVT196 2m EVT199 10 m, LED E11502 EVT132 25 m, LED E11503 EVT133 0.6 m EVT197 5m EVT200Socket, M8, 4 poles 1.0 m EVT198 10 m EVT201 2m – EVT134 5m E11223 EVT135 Dimensions 10 m E11224 EVT136 Example EVT154 25 m E11225 EVT137 M8x1 LED 2m – EVT138 10 19 5m E11220 EVT139 9 9 10 M8x1 10 m E11221 EVT140 36 L 25,5 25 m E11222 EVT141 For further technical data please go to: www.ifm.com 11.2010 65
    • product news AS-i Profinet gateway of theBus systems third generation. AS-i gateways with ultra short transfer times. Colour display for clear diagnosis and set-up. Earth fault monitor. Profinet switch with 2 ports. Profinet certification according to conformance class B. The bus at a glance The ifm gateway is the fast connection from AS-i to Pro- finet. Thanks to a colour display and web interface, the status of all AS-i slaves is recognizable at a single glance. The quick set-up menu and intuitive handling facilitate installation and diagnosis. In addition, the web interface allows full remote access. Three types of voltage supply The flexible voltage supply ensures a low-cost integration into your application. The units can be operated via AS-i power supplies, DC power supplies, or a combination of both. It is also allowed to supply several AS-i networks via a single power supply. fluid sensors and diagnostic systems position sensors and object recognition bus, identification and control systems 66
    • Bus system AS-interface Bus systemsAdvantages and customer benefits The products Communication interfaces: Description Order Profinet class B no. Profinet switch 2 ports integrated AS-i Profinet gateway 1 and 2 AS-i masters with M4 profile AC1401 1 AS-i master with M4 profile Configuration interface TCP / IP AS-i Profinet gateway AC1402 Connections: 2 AS-i masters with M4 profile AS-i and auxiliary supply: plug-in terminals AS-i data decoupling, AC1250 can be mounted on AS-i Profinet gateway (supplied with the unit) Profinet 2 x RJ45 Functions Configuration interface RJ45 Visualisation: • Pluggable data decoupling 1.8" colour display Via the optional data decoupling AC1250, the gateway LEDs for unit and fieldbus status and the connected AS-i slaves can be powered by one Housing: power supply. A single voltage source can hereby supply several gateways and their AS-i networks. Robust metal housing: aluminium powder-coated; steel sheet galvanised Power supplies with a voltage of 30 V (DC or AS-i) allow any possible AS-i structure at full cable length. Ambient temperature: Operating temperature 0...60 °C The use of a 24 V power supply offers the advantage Storage temperature -20...70 °C of AS-i power24: For AS-i networks of up to 50 m the introduction of the bus system AS-interface will become even more cost-efficient. • Transfer of AS-i data PLC user programmes can be transferred from existing Profibus to Profinet systems without changing the I /O addresses. Dimensions AC1401 / AC1402 93 106,2 128,2 135,5 67,5 AC1250 45 62,8 128,2 For further technical data please go to: www.ifm.com 11.2010 67
    • product news RFID for production and logistics.Identification systems The UHF system for worldwide use. Ultra low, low, mid and wide range antennas for every application. Ethernet TCP / IP interface for parameter setting and data transmission. UHF read / write unit with four external antenna terminals. Support of bulk reading / reader dense mode. Compliant with ISO 18000-6C, EPC, Global Class 1 Gen 2. The new UHF read / write unit from ifm As components of the UHF system platform, the read / write units DTE800 for Europe and DTE900 for the USA are compliant with 865-870 MHz and 902-928 MHz respectively. The UHF antenna concept of ifm The ultra low and low range antennas are distinguished by the near field. In order to achieve a high selectivity, the smallest possible designs are used as they manage short reading ranges. Due to its smaller dimensions the mid range antenna is chosen for applications in the near / far field with reading ranges of up to 2 m. The wide range antennas with 30° and 70° angles of aperture have been developed for applications in the far field where reading ranges of up to 7 m are required. fluid sensors and diagnostic systems position sensors and object recognition bus, identification and control systems 68
    • RF-identification systems Identification systemsApplication ProductsOwing to its application-specific antennas, the new UHF Description Ordersystem platform from ifm electronic is widely used in no.automation technology, e.g. in the fields of production,intralogistics and conveyor technology. RFID UHF reader, dimensions 270 x 234 x 68 mmGoods such as packaging or pallets can be detected with- RFID UHF reader, DTE800out contact. Ethernet, 2 DI / 2 DO, EU/ETSI RFID UHF reader,The UHF RFID has been optimised for applications in Ethernet, 2 DI / 2 DO, US/FCC DTE900• production control RFID UHF antennas, dimensions 90 x 60 x 18 mm• asset management• material flow control RFID UHF ultra low range antenna ANT805 EU/ETSI/US/FCC• track & trace RFID UHF low range antenna• supply chain management ANT810 EU/ETSIThe stationary units for setting up an identification sys- RFID UHF low range antenna ANT910tem in the UHF range allow long read / write ranges with US/FCCpassive tags. The RF readers (= read / write units) which RFID UHF antennas, dimensions 150 x 270 x 35 mmare for example used in conventional logistics and pro- RFID UHF mid range antennaduction-related logistics automatically detect every goods 100°/100° EU/ETSI ANT820movement and report it to the superposed systems.Current is supplied directly via an M12 connection. ATCP / IP Ethernet interface with M12 connection ensures RFID UHF antennas, dimensions 270 x 270 x 45 mmfast and easy integration. RFID UHF wide range antennaThe connected sensors or actuators of the inputs / out- ANT830 70°/70° EU/ETSIputs to be triggered are supplied via two additional M12 RFID UHF wide range antennasockets. ANT930 70°/70° US/FCCA robust housing with protection rating IP 65 and a wide RFID UHF antennas, dimensions 580 x 270 x 90 mmtemperature range ensure the use of the readers in harsh RFID UHF wide range antennaindustrial environments. 30°/70° EU/ETSI ANT840 RFID UHF wide range antenna ANT940 30°/70° US/FCCAccessories Common technical data Type Description Order DTE800, DTE900 no. Operating voltage [V] 24 DC ± 10 % Installation kit for wide range antenna E80340 Current consumption [mA] < 700 Current rating outputs [mA] 500 (per switching output) Ambient temperature [°C] -25...55 Protection IP 65 Connection cable for antennas RG58, E80330 Metal housing 3m Material with plastic cover Connection cable for antennas RG58, E80331 Switching inputs 2 6m Switching outputs 2 Ethernet, cross-over patch cable, E11898 2 m, PUR cable, M12 / RJ45 Frequency range EU/ETSI [MHz] 865...870 Ethernet, shielded patch cable, Frequency range US/FCC [MHz] 902...928 E12090 2 m, PUR cable, M12 / RJ45 Air interface ISO 18000-6C Ethernet, cross-over patch cable, Range [m] 7, depending on the tag E12204 10 m, PUR cable, M12 / RJ45 Antenna concept external Ethernet, cross-over patch cable, E12205 Antenna terminal, external 4 x TNCreverse 50 ohm 20 m, PUR cable, M12 / RJ45 RFID UHF transponder E80350 ID-TAG/D50X3.3/04 RFID UHF on-metal transponder E80351 ID-TAG/D55X13/04 For further technical data please go to: www.ifm.com 11.2010 69
    • product news For long distances: CANremote –Control systems remote diagnosis and visualisation. Web-based, wireless data exchange for mobile machines. Real-time diagnosis via CoDeSys programming system. Data indication and storage via configurable web portal. Indication and processing of geographical and route data. Integration into a machine network via CAN /CANopen interface. Predefined software libraries to IEC 61131-3. CANremote: wireless data exchange in real time or via an internet portal. In times of globalisation the distances to the customer keep increasing. The costs for the provision of services and reduction of downtime in case of malfunctions are becoming more and more important. Therefore machine and plant builders more and more often use the remote diagnosis via GSM /GPRS / EDGE radio connection. The CANremote radio gateway transfers the data directly from the machine controller. It is either transferred to the programming or diagnostic system of the machine manufacturer in real time or is buffered on a server and is available at any time via an internet portal. With CANremote GPS the position data can be directly visualised in the internet portal. fluid sensors and diagnostic systems position sensors and object recognition bus, identification and control systems 70
    • Control systemsfor mobile vehicles Control systemsFunctions and advantages ProductsWith CANremote, a complete hardware and software Description Orderpackage for remote maintenance via CoDeSys and ac- no.cess to application data via an internet portal is availablefor the first time. Units and accessoriesThe speed-optimised communication protocol also allows CANremote GSM quadband modem CR3105parameter setting of machines and machine tracking via CANremote GSM/GPS quadband modem CR3106GPS or fleet management. The different cost models for CANremote GSM antenna EC2092data services provide a cost-optimised solution for all CANremote GSM/GPS antenna EC2093controllers and displays of the ecomatmobile family. Socket, M12, 2 m black, PUR cable EVC070• RealTimeAccess of ifm electronic Socket M12, 5 m black, PUR cable EVC071 There is a real-time point-to-point connection between the programming PC for CoDeSys and the ecomatmo- Communication packages bile control component connected via GSM. Real-time access / internet portal / GPS (Europe) ZC0029 This connection allows access to the program down- Real-time access ZC0030 load, the debugging and the data of the machine con- Internet portal ZC0031 trol. For faster data transmission, an optimised com- munication protocol was developed. Internet portal / GPS (Europe) ZC0032 Among others the following functions are available: Real-time access for device pool ZC0033 - management of login data Real-time access / portal on demand ZC0034 - machine selection via dropdown list One-time customer-specific presetting ZC0035 - GSM status information Data transfer via Web Service Client ZC0036 - all monitoring and download functions of the System architecture CoDeSys programming environment• WebPortal of ifm electronic Parameters, machine information and position data can be stored and presented customer-specifically and machine-specifically on a predefined internet site. Among others the following functions are available: - customer-specific login screen with logo - free labelling of the heads of the columns - vehicle / machine overview - vehicle / machine tracking via Google Maps® with Geofencing function - GSM status information - presentation of the machine data tables - data analyses - upload and download of data (files can be loaded to or from the controller.) - customer-specific access to management functions• programming to IEC 61131-3 For the programming software CoDeSys and all pro- grammable devices of the ecomatmobile family, func- tion libraries that facilitate the integration of remote maintenance and diagnostic functions considerably are available. The function and program modules can be used immediately no matter if an SMS or e-mail is dis- patched of if operational and diagnostic data is trans- ferred.Applications:• complex construction machines, agricultural machines, municipal vehicles For further technical data please go to: www.ifm.com 04.2011 71
    • product news ecomatmobile Basic –Control systems integrate, activate, operate. Automation of mobile vehicles – easy, modular, cost-optimised. Easy installation thanks to a well-coordinated mechanical concept. Connection of sensors and actuators without further external wiring. Indication of system messages and visualisation of machine functions. High-performance CAN interfaces for various communication tasks. Programmable to IEC 61131-3 with CoDeSys. ecomatmobile Basic In many small and compact mobile applications, the re- quirements on control tasks are increasing. Cost-optimised and modular mini controllers for mobile use have not been available so far. Based on comprehensive market research ifm electronic has developed an appropriate control sys- tem. The result: ecomatmobile Basic. ecomatmobile Basic consists of three components which are well-adapted to each other: BasicRelay, BasicController, BasicDisplay. The ecomatmobile Basic control system has a modular design, is easy to install and to operate and is cost-opti- mised. Besides pure control functions it provides sol- utions for wiring and protection. In addition, a graphical visualisation module ensures the indication of system messages and simple display instru- ments. fluid sensors and diagnostic systems position sensors and object recognition bus, identification and control systems 72
    • Control systemsfor mobile vehicles Control systems BasicRelay Products Facilitates the connection Description Order and wiring. no. BasicRelay BasicRelay CR0421 Accessories BasicRelay contact set EC0457 Cover IP 54Functions and advantages EC0401 without display recess, with cable sealThe easily expandable relay and safety module finallybrings order to your wiring. Thus, it becomes a small, Technical datadecentralised “control room” for easy applications. BasicRelay• The mechanical structure Easy installation allows the use of the module exactly Housing plastic where it is needed. Locations for relays The BasicRelay is ready for connection and can be used (5 contact holders 6.3 mm, 6 without any external terminals. 4 contact holders 2.8 mm) Due to an increase of the protection rating through a Locations for automotive fuses cover and a pluggable cable seal, the BasicRelay can up to 30 A 10 (Splittable into 3 supply circuits) now also be used in areas that are exposed to splashing water. Supply rails for supply voltage and 2• The powerful wiring ground connection (GND) The BasicRelay features locations for automotive ISO Protection IP 20 relays. The additional 2.8 mm spring contacts allow with EC0401 cover IP 54 the use of solid state and logic relays with diagnostic Operating voltage [V DC] ≤ 30 capability. Total current [A] ≤ 80 In order to protect the individual load circuits there are Temperature range operation [°C] -40...85 ten locations for automotive fuses available. storage [°C] -40...85 By a common power rail and additional star points the CE, Standards and tests (extract) e1 (RL 2009/19/EC), load currents in the module can be distributed. The BN 411 002 integrated, confusion-free screw terminals allow for a connection to the battery cables. This means that no further external terminals are needed for the wiring. The wiring of the relay locations and fuse contacts is done on the spot with easy-to-install cable links or a ready-to-use cable tree.Applications:• compact construction machines• attachable units• mini vehicles 73
    • Control systems BasicController Products Small, compact, robust. Description Order no. BasicController BasicController 12 I / 12 O CR0403 Starter set includes BasicRelay, BasicController, BasicDisplay EC0400 incl. software, power supply, cable and accessories Functions and advantages Accessories The compact, flexible and inexpensive mini controller re- Cover IP 54 places the conventional relay logic and also demanding without display recess, with cable seal EC0401 and complex process controllers. Cover IP 54 EC0402 • The mechanical structure with display recess, with cable seal The control electronics integrated in a compact plastic Connection cable for 2 BasicControllers, 50 cm EC0451 housing provide all the necessary connections for the Plug set for BasicController EC0456 inputs and outputs, communication and program- CAN programming interface CANfox EC2112 ming. The coded connectors for mobile use are easy Adapter set CAN/RS232 for CANfox EC2113 to handle and available all over the world. The con- Programming software CoDeSys V2.3, German CP9006 nection of sensors and actuators is carried out without Programming software CoDeSys V2.3, English CP9008 further external wiring. Due to an increase of the pro- tection rating through a cover and a pluggable cable Common technical data seal the BasicController can also be used in areas that are exposed to splashing water. BasicController • The powerful electronics The integrated 32-bit processor and the electronics Housing plastic, potted are optimally tailored to the application. By means of AMP blade male terminals the application software the inputs and outputs can Device connection 6.3 mm be configured to adapt to the respective application. Protection IP 20 A status LED indicates the current operating status of with EC0401, EC0402 cover IP 54 the module. Operating voltage [V DC] 8...32 • Programming to IEC 61131-3 Current consumption [mA] ≤ 45 The CoDeSys software enables a clear and easy creation Temperature range operation [°C] -40...85 storage [°C] -40...85 of the application software for the user. The control module BasicController supports all common CoDeSys PowerPC 5517E Processor 50 MHz programming languages. For communication and spe- Indication LED (red/green) cial unit functions simple and clearly structured func- tion libraries are available. Data memory SRAM [kB] 208 / 592 CR0401 / CR0403 • The communication interfaces Data memory Flash [kB] 1536 The BasicController is equipped with two CAN interfaces Data memory (retain), FRAM [kB] 1 to ISO 11898. These interfaces are for example used to Inputs (total): 12 exchange data with the connected BasicDisplay, further digital, analogue, frequency 4 BasicController modules or the engine controller. The digital, resistance measurement 4 digital 4 interfaces support the CANopen and the J1939 protocol among others. Outputs (CR0401, CR0402, total): 8 digital, PWM, 2 A 2 For programming, the CAN interfaces are used as well. digital, PWM, 1 A 4 To do so, the unit electronics are directly and conveni- digital, PWM, 4 A 2 ently activated via the powerful PC-CAN interface CAN Outputs (CR0403, total): 12 fox. In this way, operating system and application pro- digital, PWM, 2 A 4 digital, PWM, current-controlled, 2 A 2 gramme can be loaded or parameters changed. digital, PWM, 1 A 4 digital, PWM, 4 A 2 Applications: Supported CAN protocols CANopen (DS 301 V4.1) • compact construction machines (CANopen only CR0403) SAE J 1939 • attachable units Standards and tests (extract) CE, e1 (RL 2009/19/EC) • mini vehicles 74
    • Control systemsfor mobile vehicles Control systems BasicDisplay Products To be fully in the picture. Description Order no. BasicDisplay BasicDisplay, 2.8", 320 x 240 pixels CR0451 Accessories Mounting frame for panel mounting BasicDisplay EC0403 Connection cable BasicDisplay, 10 cm, internal EC0452Functions and advantages Connection cable BasicDisplay, 10 cm, internalThe high-resolution colour display and a unique visual- EC0453 2 BasicControllers, 50 cmisation concept replace the conventional analogue dis- CAN programming interface CANfox EC2112play and, in part, the rudimentary operating elements of Adapter set CAN/RS232 for CANfox EC2113the machine. Programming software CoDeSys V2.3, German CP9006• The high-resolution display Programming software CoDeSys V2.3, English CP9008 Protected by a continuous membrane the modern dis- play, which can even be read in sunlight, provides a Technical data resolution of 320 X 240 pixels with an aspect ratio of 4:3. Graphics can be shown with a colour depth of up BasicDisplay to 256 colours.• The mechanical structure Housing plastic The BasicDisplay has a sealed plastic housing with pro- Device connection M12 connector tection rating IP 67. The integrated M12 connector provides all important connections for supply and Protection front IP 67 back IP 65 communication. The display can be easily mounted using a centralised fixing nut, either directly on the Operating voltage [V DC] 8...32 operator panel or in the module cover. Current consumption [mA] ≤ 70• The powerful electronics Temperature range operation [°C] -20...70 storage [°C] -30...80 The integrated 32-bit processor and the electronics 2.8" TFT LCD display tailored to the applications are optimally adapted to Display 320 x 240 the application area. A status LED indicates the current 256 colours operating status of the display. Processor PowerPC 5517E Stand-alone operation of the BasicDisplay is possible 50 MHz via the integrated watchdog. Indication LED (red/green)• Programming to IEC 61131-3 Data memory SRAM [kB] 592 The CoDeSys software enables a clear and easy crea- Data memory Flash [kB] 1536 tion of the application software for the user. Function Data memory (retain), FRAM [kB] 1 libraries are available for the special functions of the Function keys with softkey function, 5 BasicDisplay. backlit The graphic elements are created and animated via Rocker switch with cursor function, 1 backlit the integrated visualisation. CANopen (DS 301 V4.1)• The communication interface Supported CAN protocols SAE J 1939 The BasicDisplay is fitted with a CAN interface to ISO Standards and tests (extract) CE, e1 (RL 2009/19/EC) 11898. These interfaces are for example used to ex- change data between the connected controller, the de- centralised input / output modules or the engine con- troller. For this purpose the interface supports the CANopen and the J1939 protocol among others. With the master functionality of the CANopen protocol, networks can be built via decentralised input / output modules.Applications:• compact construction machines• attachable units• mini vehicles For further technical data please go to: www.ifm.com 11.2010 75
    • product news Dialogue module PDM360 NGControl systems for mobile vehicles. 7.0" TFT colour display with a resolution of 800 x 480 pixels. 9 backlit function keys with tactile feedback. Encoder with pushbutton or alternatively rocker switch. 1 gigabyte internal mass storage and USB interface for external media. 4 CAN interfaces with CANopen and SAE J1939 protocol. Programmable to IEC 61131-3 with CoDeSys 2.3. PDM360 NG dialogue module In almost all mobile machines a powerful process and dialogue unit is needed for machine operation and for indication of system messages. With its high-resolution graphic display, the powerful 32-bit controller and the flexible programming according to IEC 61131-3, the PDM360 NG is such a user interface. Its robust housing with protection rating IP 67 enables mounting inside or outside the cabin. It has been designed for surface and panel mounting. Four CAN interfaces, Ethernet and USB together with the Linux operating system form a universal platform for net- working and communication with other vehicle compo- nents. fluid sensors and diagnostic systems position sensors and object recognition bus, identification and control systems 76
    • Control systemsfor mobile vehicles Control systemsFunctions and advantages Products• High-resolution display Description Order Protected by a scratch-resistant glass pane, the modern no. display, which can even be read in sunlight, provides a Dialogue module PDM360 NG with encoder CR1080 resolution of 800 x 480 pixels with an aspect ratio of Dialogue module PDM360 NG with rocker switch CR1081 15:9. Images and graphics can be shown with a colour depth of up to 18 bits. Mounting frame for panel mounting EC2110 USB adapter cable, M12 / RJ45 socket, 1.5 m EC2099• Mechanical structure Ethernet, cross-over patch cable, The PDM360 NG has a fully sealed diecast aluminium E11898 2 m, PUR cable, M12 / RJ45 housing with protection rating IP 67. The integrated Socket, M12, 2 m black, PUR cable EVC001 M12 connectors provide all important connections for Socket, M12, 5 m black, PUR cable EVC002 supply, inputs /outputs and communication. It can be Programming software CoDeSys, German version CP9006 used as surface mount devices using the tried-and- Programming software CoDeSys, English version CP9008 tested RAM® mount system or can be mounted in a wall. The service lid on the back allows the exchange Technical data of the battery for the real-time clock as well as access to the USB 2.0 service interface. Dialogue modules PDM360 NG CR1080, CR1081• The powerful electronics The integrated 32-bit controller and the operating Housing closed, system Embedded Linux are the basis for the visualisa- diecast aluminium tion of the high-resolution graphics, the processing of 1 x M12 connector Device connection 6 x M12 socket the application program and the unit functions. Due to its universal software structure Embedded Linux Protection IP 65 / IP 67 furthermore provides many possibilities as regards com- Operating voltage [V DC] 10...32 munication and networking with other systems and Current consumption [mA] ≤ 300 networks. Temperature range operation [°C] -30...65 storage [°C] -30...80• Programming to IEC 61131-3 7" TFT-LCD display The CoDeSys software enables a clear and easy crea- Display 800 x 480 pixels tion of the application software for the user. Function 18-bit colour depth libraries are available for the special functions of the Indication RGB LED display. The graphic elements are created and animated Processor MPC5121 via the integrated visualisation. 32 bit, 400 Mhz Data memory Flash [MB] 128• The communication interfaces Data memory SRAM [MB] 128 The PDM360 NG is equipped with four CAN interfaces Internal mass storage [GB] 1 to ISO 11898. These interfaces are for example used to exchange data with the connected controller, the de- Operating elements pushbuttons 9 CR1080 (backlit) encoder 1 centralised input/output modules or the engine con- Operating elements pushbuttons 9 troller. For this purpose the interfaces support the CR1081 (backlit) rocker switch 1 CANopen and the J1939 protocol among others. The Inputs (digital/analogue/frequency) 1 integrated USB 2.0 interfaces provide easy data ex- Inputs with special functions: change with modern storage media. Internal temperature sensor 1 The Ethernet interface cannot only be used for pro- Photoelectric sensor 1 gramming but also for communication with other net- Outputs (digital) 1 work participants. 4 x CANApplications: Interfaces 1 x Ethernet 100 Mbit 2 x USB 2.0• Complex construction machines CANopen (DS 301 V4)• Agricultural machines Supports CAN protocols SAE J 1939• Municipal vehicles Programming software CoDeSys V2.3 CE, Standards and tests e1 (RL 2009/19/EC), (extract) BN 411 002 For further technical data please go to: www.ifm.com 11.2010 77
    • visit our website: www.ifm.comOverview ifm product range: Position sensors Fluid sensors Bus systems and object recognition and diagnostic systems Bus system AS-Interface Inductive sensors Level sensors Power supplies Capacitive sensors Flow sensors Connection technology Magnetic sensors, Pressure sensors cylinder sensors Temperature sensors Identification systems Safety technology Diagnostic systems Multicode reading systems Valve sensors Evaluation systems, RF-identification systems Photoelectric sensors power supplies Power supplies Object recognition Connection technology Connection technology Encoders Evaluation systems, Control systems power supplies Control systems Connection technology for mobile vehicles Connection technology ifm article no. 7511434 · Printed in Germany on non-chlorine bleached paper. We reserve the right to make technical alterations without prior notice. · 04.2011