Your SlideShare is downloading. ×
0
High efficiency solutions for server rooms
High efficiency solutions for server rooms
High efficiency solutions for server rooms
High efficiency solutions for server rooms
High efficiency solutions for server rooms
High efficiency solutions for server rooms
High efficiency solutions for server rooms
High efficiency solutions for server rooms
High efficiency solutions for server rooms
High efficiency solutions for server rooms
High efficiency solutions for server rooms
High efficiency solutions for server rooms
High efficiency solutions for server rooms
High efficiency solutions for server rooms
High efficiency solutions for server rooms
High efficiency solutions for server rooms
Upcoming SlideShare
Loading in...5
×

Thanks for flagging this SlideShare!

Oops! An error has occurred.

×
Saving this for later? Get the SlideShare app to save on your phone or tablet. Read anywhere, anytime – even offline.
Text the download link to your phone
Standard text messaging rates apply

High efficiency solutions for server rooms

1,539

Published on

Prezentare sustinuta de Eduard Bodor, Senior System Engineer APC in cadrul evenimentului "Proiectele europene si tehnologia informatiei – solutia cresterii economice pentru IMM-uri" organizat de IDG …

Prezentare sustinuta de Eduard Bodor, Senior System Engineer APC in cadrul evenimentului "Proiectele europene si tehnologia informatiei – solutia cresterii economice pentru IMM-uri" organizat de IDG Romania

Published in: Technology
0 Comments
1 Like
Statistics
Notes
  • Be the first to comment

No Downloads
Views
Total Views
1,539
On Slideshare
0
From Embeds
0
Number of Embeds
1
Actions
Shares
0
Downloads
78
Comments
0
Likes
1
Embeds 0
No embeds

Report content
Flagged as inappropriate Flag as inappropriate
Flag as inappropriate

Select your reason for flagging this presentation as inappropriate.

Cancel
No notes for slide

Transcript

  • 1. High Efficiency Solutions for Server Rooms Environment description and solution overview Eduard Bodor Senior System Engineer APC by Schneider Electric gives you the ability to power, cool, monitor, manage and service your server room with ease and confidence. Server rooms are 1- 5 rack environments that are often not specifically designed to provide the ideal environment for IT equipment.
  • 2. Unplanned growth  Tendency toward chaos Overheating Clogged underfloor Cable spaghetti Overdue maintenance “ Replace Battery” warning light It’s a swamp! Where can I plug it in?
  • 3. Trends impacting the environment <ul><li>Consolidation makes the server room a dynamic and unpredictable environment </li></ul><ul><li>Virtualization adds complexity to physical infrastructure and dramatically increases criticality of the physical server availability </li></ul><ul><li>Higher Density IT can drive the need for dedicated supplemental cooling </li></ul><ul><li>IT managers need to deliver higher levels of availability driving the need for higher performance power, cooling, racks, management and services. </li></ul><ul><li>Corporate governance and pending government regulations are driving increased efficiency requirements </li></ul><ul><li>Corporate desire for lower capital, operating and maintenance costs </li></ul>
  • 4. Typical customer problems <ul><li>My server room has experienced unplanned and unorganized growth and has become unreliable in operation and problematic to diagnose issues </li></ul><ul><li>I don’t know where or how to start the process of designing or building a new server room </li></ul><ul><li>I don’t know how to determine how much power and cooling capacity is left in each rack </li></ul><ul><li>I don’t know how to determine the optimal place to install new IT equipment in the IT racks for maximum efficiency and availability </li></ul><ul><li>When I have a problem I have to call multiple vendors for service </li></ul><ul><li>My server room is not designed for quick and easy growth or scalability </li></ul><ul><li>My server room is very cold and costs much more in electricity than it used to, but I still have hot spots and overheating servers </li></ul><ul><li>I have one or multiple server rooms that I would like to remotely manage from one central location. </li></ul>
  • 5. Modular architecture Scaled to follow the load Scalable architecture avoids waste Power/cooling capacity IT load Non-modular architecture Full buildout on day one A server room does not have to be inefficient ! Oversizing = inefficiency “ Right-sizing” Unused power and cooling capacity wastes capex, opex, and energy
  • 6. Standardized modular components Environmental Monitoring UPS InRow cooling unit Rackmount PDU Rack Universal – accepts all server designs Centralized Management
  • 7. <ul><li>Together, these design principles comprise the architecture </li></ul>Putting it all together This architecture can be deployed quickly, anytime, anywhere – enabling virtualization, handling high density, and increasing efficiency
  • 8. Close-coupled cooling ™ <ul><ul><li>Closely couples cooling with heat load, preventing air recirculation </li></ul></ul><ul><ul><li>Powerful enough to for spaces with no cooling, or as a supplement to overloaded comfort systems </li></ul></ul><ul><ul><li>Built-in management capabilities </li></ul></ul><ul><ul><li>Heat rejection up to 10kW with waterless design. </li></ul></ul><ul><ul><li>Lowers operating cost by monitoring inlet temperatures to modulate cooling capacity based on the cooling demand </li></ul></ul>Reduce power consumption up to 20% with InRow ® architecture Fan speed adjusts to follow changing IT heat load
  • 9. Rack Air Containment <ul><li>Perfect for single row server rooms </li></ul><ul><li>Rear containment prevents hot exhaust air from escaping </li></ul><ul><li>Optional front containment directs cool air to front of servers </li></ul><ul><li>Maximizes efficiency and effectiveness of InRow cooling </li></ul>Top Down View Front Rear InRow coolingunit InRow cooling unit Rear Containment Front Containment Top view NetShelter SX rack
  • 10. Manage cooling (without being there) <ul><li>Wiring Closet Ventilation Unit </li></ul><ul><ul><li>Easily configured for remote monitoring </li></ul></ul><ul><ul><li>Control the unit based on a predefined temperature set </li></ul></ul><ul><ul><li>Designed specifically for network closets </li></ul></ul><ul><li>InRow® SC air conditioning solution </li></ul><ul><ul><li>Monitor current and available cooling capacity in real time from anywhere on the network. A sophisticated microprocessor controller provides up-to-the-second data on inlet temperature, supply and return air temperature, airflow, cooling output and demand, and a dozen other status readings. </li></ul></ul>
  • 11. Monitor the environment - without being there <ul><li>NetBotz® monitoring appliances </li></ul><ul><li>Integrated surveillance cameras </li></ul>
  • 12. Centralized monitoring software <ul><ul><li>Real-time monitoring </li></ul></ul><ul><ul><li>One standard IP address </li></ul></ul><ul><ul><li>System-wide data </li></ul></ul><ul><ul><li>Power </li></ul></ul><ul><ul><ul><li>APC Smart-UPS® and Symmetra® units with embedded management capabilities </li></ul></ul></ul><ul><ul><li>Cooling </li></ul></ul><ul><ul><ul><li>InRow® air conditioning solution with embedded management capabilities </li></ul></ul></ul><ul><ul><li>Physical security systems </li></ul></ul><ul><ul><ul><li>NetBotz® monitoring appliances </li></ul></ul></ul><ul><ul><li>Row, rack, and U level </li></ul></ul><ul><ul><ul><li>Metered and Switched Rackmount PDU with embedded management capabilities </li></ul></ul></ul>InfraStruXure Central
  • 13. Pre-configured solutions* InfraStruXure for Server Rooms (1-5 Racks, 1-16kVA) NetShelter SX rack with Smart-UPS® RT • NetShelter SX rack enclosure, 42U • APC rack-mount Smart-UPS RT (choice of 5kVA, 8kVA/230V, or 10kVA) • Metered rack PDU, zero U • UPS network management card w/ environmental monitoring • User-replaceable batteries *NAM only NetShelter SX rack with Symmetra® LX • NetShelter SX rack enclosure, 42U • APC rack-mount Symmetra LX (8kVA or 16kVA) • Configurable for N+1 internal redundancy • Metered rack PDU, zero U • UPS network management card w/ environmental monitoring • User-replaceable batteries and modules
  • 14. Planning tools to support projects <ul><li>Standardized tools “bottle” our expertise and streamline the process </li></ul>Data Center Standard Specification ISX Designer – Drag-and-drop tool to lay out whole data center or just a new zone TradeOff Tools – Interactive tools for exploring what-if design scenarios Data center project process
  • 15. <ul><li>ARCHITECTURE – Standardized, modular structure Addresses all the challenges – High density, efficiency, scalability, standardization with flexibility </li></ul>APC server room solutions MANAGEMENT – Real-time, rack-level, model-based The “brain” that enables reliable high density, lean capacity, and high efficiency Components SOLUTION <ul><li>Whole-system “smart” design </li></ul><ul><li>SOLUTION that integrates all elements </li></ul>Standardized PROCESS and Design Tools - Standardized, repeatable process for planning and building Predictable roadmap – Standardized, no surprises, less cost, faster deployment SERVICES – Clearly defined by scopes-of-work (SOWs)
  • 16. <ul><li>[email_address] </li></ul>

×