Virtual instrumentation for measurement of strain using thin film strain gauge sensors
Upcoming SlideShare
Loading in...5
×
 

Virtual instrumentation for measurement of strain using thin film strain gauge sensors

on

  • 1,084 views

 

Statistics

Views

Total Views
1,084
Slideshare-icon Views on SlideShare
1,084
Embed Views
0

Actions

Likes
0
Downloads
22
Comments
0

0 Embeds 0

No embeds

Accessibility

Categories

Upload Details

Uploaded via as Adobe PDF

Usage Rights

© All Rights Reserved

Report content

Flagged as inappropriate Flag as inappropriate
Flag as inappropriate

Select your reason for flagging this presentation as inappropriate.

Cancel
  • Full Name Full Name Comment goes here.
    Are you sure you want to
    Your message goes here
    Processing…
Post Comment
Edit your comment

    Virtual instrumentation for measurement of strain using thin film strain gauge sensors Virtual instrumentation for measurement of strain using thin film strain gauge sensors Document Transcript

    • International Journal of Advanced Research in Engineering (IJARET) International Journal of Advanced Research in Engineering and Technologyand Technology (IJARET), ISSN 0976 – 6480(Print),ISSN 0976 – 6499(Online) Volume 1, IJARET ISSN 0976 – 6480(Print), ISSN 0976 – 6499(Online) Volume 1, Number 1, July - Aug (2010), © IAEMENumber 1, July - Aug (2010), pp. 68-76 © IAEME© IAEME, http://www.iaeme.com/ijaret.html VIRTUAL INSTRUMENTATION FOR MEASUREMENT OF STRAIN USING THIN FILM STRAIN GAUGE SENSORS Kalpana H.M Department of Instrumentation Siddaganga Institute of Technology, Tumkur-572103 E-mail: hm_kalpanaravi@yahoo.co.in John R Stephen Department of Instrumentation Siddaganga Institute of Technology, Tumkur– 572103 ABSTRACT: This paper describes the development of thin film strain gauge sensor for strain measurement and indication using LabVIEW. The strain gauges designed were deposited on either side of the cantilever of Beryllium copper (Be-Cu) using DC magnetron sputtering technique. LabVIEW version7.1, signal conditioning connecter block SCC2345 with half bridge type II strain gauge input module SG03 and Data Acquisition (DAQ) board 6221 have been utilized for the acquisition and indication of strain. Strain was also calculated & compared with the indicated value. The error found to within 0.5%. The developed strain gauges are expected to be used in aerospace and biomedical applications for the measurement of micro strain. Keywords: strain, Thin film strain gauge, LabVIEW. INTRODUCTION Measurement of strain is important in automotive and biomedical applications, aerospace industries, and also in seismic testing of bridges and other structures [1]. Strain depends on the amount of deformation of a body due to an applied force. More specifically, strain is defined as the fractional change in length. While there are several 68
    • International Journal of Advanced Research in Engineering and Technology (IJARET)ISSN 0976 – 6480(Print), ISSN 0976 – 6499(Online) Volume 1, Number 1, July - Aug (2010), © IAEMEmethods of measuring strain, the most common is with a strain gauge, a device whoseelectrical resistance varies in proportion to the amount of strain in the device. Strain gauge is a sensing device or sensor used to measure the linear deformationoccurring in the material during loading [2]. Based on the principles of operation, straingauges are classified as electrical, mechanical, optical, acoustical and pneumatic [3].Among these the electrical strain gauges have become widely accepted and at presentdominate this field. The different types of electrical strain gauges are metallic foil,semiconductor and thin film. Foil type strain gauge sensor is the most commonly usedone, but it has limitations such as thermal degradation, relatively low output signals,requirement of careful installation procedures and degradation in performance due tomoisture effect [4]. These limitations are overcome by using thin film sensors. Hence thinfilm strain gauges have widespread use in industry. Different kinds of materials that areused for thin film strain gauges are metals, alloys, cermets and semiconductors. The highresistivity of alloys along with their low temperature coefficient of resistance (TCR) andgood temporal stability make them prime candidates for strain gauge application.Nichrome (NiCr 80/20 wt.%) is the most widely used alloy because of its high resistivity,low TCR, commercial availability, low temperature dependence of gauge factor andsimilar properties[5]. The aim of this work is to design and develop Nickel-Chromium (NiCr) thin filmstrain gauge sensors and interface with associated instrumentation for strain measurementand indication using Virtual Instrumentation A virtual instrumentation system is the use of customizable software and modularmeasurement hardware to create user defined measurement systems. National Instruments (NI) LabVIEW data acquisition hardware and softwaremodules have become one of the most widely used tools to capture, view, process andcontrol. Hence, NI hardware has been utilized in our work also.2. DEVELOPMENT OF THIN FILM STRAIN GAUGES The strain gauge development involves the design of strain gauge, preparation ofcantilever beam (substrate), deposition of thin film strain gauges on it and wiring. Thesuitable pattern required for the thin film strain gauge was designed using AutoCAD. A 69
    • International Journal of Advanced Research in Engineering and Technology (IJARET)ISSN 0976 – 6480(Print), ISSN 0976 – 6499(Online) Volume 1, Number 1, July - Aug (2010), © IAEMEphoto plot of designed gauge pattern was obtained and, with the help of it, mechanicalmasks of Be-Cu material were made. The surface condition of the substrate and the type of the substrate material usedinfluence the performance of thin films [6 ]. The surface roughness of the substrateaffects the adhesive property of thin films [7,8]. Hence prior to the application of thepolymer layer, the surface of the substrate was prepared using standard polishing andcleaning procedures. In the present work Beryllium-copper (Be-Cu) material (98%copper and 2% Beryllium) has been chosen as substrate, because Be-Cu is a highlyductile material, which can be stamped and formed into very complex shapes with theclosest tolerances. Be-Cu can be strengthened by precipitate hardening. Heat treated Be-Cu features excellent dimensional stability, fatigue resistance and corrosion resistanceand mechanical strength. In order to electrically isolate the thin film strain gauges from the metallic surface,a thin layer of an epoxy adhesive (M-Bond 610) was applied on either side of thesubstrate. This polymer provides the highest level of performance and is suitable fortemperatures up to +230° C. The polymer layer was applied uniformly on the requiredregion and heat treatment of the substrate was done immediately in a temperature-controlled oven at 150°C for about 2hrs. Using the mechanical masks, thin film strain gauges were deposited on either sideof the cantilever beam using the DC Magnetron sputtering technique. This technique hasbeen chosen because of its high ionization efficiency and good adhesion of the depositedfilms & better molecular bonds that will ensure faithful transfer of strain experienced bythe strain gauges. The sputtering system used consists of an arrangement in which a plasmadischarge was maintained between the anode or substrate (Be-Cu) and the cathode ortarget (Nickel-Chromium). The chamber of the system was initially evacuated to apressure of 10-6 torr using a combination of rotary and diffusion pump and back filled tosputtering pressure with the inert gas argon [9,10]. The deposition parameters wereoptimized to achieve the required properties for the film. Thin film strain gauges ofNichrome were sputter deposited on either side of the cantilever. 70
    • International Journal of Advanced Research in Engineering and Technology (IJARET)ISSN 0976 – 6480(Print), ISSN 0976 – 6499(Online) Volume 1, Number 1, July - Aug (2010), © IAEME3. TRANSDUCER PARAMETRIC ANALYSIS A mechanical setup was designed and developed for study the characteristics ofthe strain gauge developed. The setup consists of a rectangular base plate made of brassmaterial with a cylindrical rod fixed vertically at the left wherein a fixture has beenprovided for holding the strain gauges in the form of a cantilever. The free end of thecantilever can be deflected by means of a digital micrometer fixed to a holder. Fig.1shows the photograph of the cantilever set up with strain gauges. Figure 1 Shows the photograph of the cantilever set up with strain gauges. The fractional change in resistance with respect to deflection of the cantileverwere stored in the data files.Using National Instruments LabVIEW version8.0,VI blockdiagram was created with spread sheet read icon and express xy plotter as shown in fig2.Data read by spread sheet reader and plotted in the xy plotter is found to be linear forboth compression & tensile mode and is as shown in figs 3 & 4 Figure 2 VI Block diagram to read & plot compression & tensile mode resistance values 71
    • International Journal of Advanced Research in Engineering and Technology (IJARET)ISSN 0976 – 6480(Print), ISSN 0976 – 6499(Online) Volume 1, Number 1, July - Aug (2010), © IAEME Figure 3 Deflection of Cantilever versus Figure 4 Deflection of cantilever versus strain gauge resistance under Strain gauge resistance under Compression tension. The gauge factor of the strain gauges developed were determined to be ~ 2.7using four point bending method.4. HARDWARE DESCRIPTION The block diagram of the strain measurement system developed is shown in Fig.5and the function of each of the blocks is explained below. Sensor Signal DAQ Unit conditioning unit unit PC with LabVIEW Figure 5 Block diagram of strain measurement system4.1 Sensor Unit. The sensor unit consists of a cantilever with thin film strain gauges on either side.The cantilever was fixed to the mechanical setup.4.2 Signal conditioning unit. This unit consists of NI signal conditioning connector block SCC2345 and straingauge input module SG03 [11].The SCC2345 has 20 SCC sockets, labeled J1 throughJ20. Sockets J1 through J8 accommodate SCC modules for conditioning signals on theanalog input channels of the DAQ card. SCC-SG03 is a dual-channel strain gauge module for conditioning half bridgestrain gauges. This module has two strain gage input channels, offset nulling circuitry for 72
    • International Journal of Advanced Research in Engineering and Technology (IJARET)ISSN 0976 – 6480(Print), ISSN 0976 – 6499(Online) Volume 1, Number 1, July - Aug (2010), © IAEMEeach channel and a 2.5V excitation source. Each input channel includes aninstrumentation amplifier with differential inputs with a fixed gain of 100. The output ofeach amplifier is filtered and buffered to prevent settling time delays.4.3 DAQ unit: DAQ card PCI6221 is required for the interfacing purpose. Hardwarefunctionality includes 16 analog inputs, 2 analog outputs, 24 digital I/O, counter/timers,triggering and synchronization circuitry.4.4 Personal Computer with Labview Personal computer with labVIEW version7.1 has been used for acquisition andindication of strain, in our present work.5 DATA ACQUISITION AND PRESENTATION USING LABVIEW The cantilever was fixed to the mechanical setup fabricated and strain gaugeswere connected to the strain gauge input module SG03. The bridge completion resistorspresent in SG03 completes Wheatstone bridge configuration. SG03 module was insertedinto one of the analog input sockets of the SC2345 connector, which in turn wasconnected to the PC through DAQ card 6221.The experimental set up is as shown in fig.6 Figure 6 Photograph of the experimental set up The data acquisition board was configured for strain measurement using themeasurement & Automation Explorer (MAX) of LabVIEW. Configuration was done byentering the gauge factor, gauge resistance, minimum & maximum values of strain to beindicated & setting the excitation voltage as internal. The strain gauge input moduleSG03 was configured as half bridge type II which measures only bending strain [12]. The block diagram VI & front panel VI were constructed using appropriate icons& function pallets of NI DAQmx on LabVIEW platform. These are shown in Figure 7 &Figure 8 respectively. 73
    • International Journal of Advanced Research in Engineering and Technology (IJARET)ISSN 0976 – 6480(Print), ISSN 0976 – 6499(Online) Volume 1, Number 1, July - Aug (2010), © IAEME Figure 7 Block Diagram VI of strain Figure 8 Front panel VI of strain measurement measurement system system Known weights were added in steps to the free end of the cantilever and thecorresponding amplified & filtered bridge output voltage of SG03 was acquired byanalog input (AI) channel by continuous sampling and was converted to strain, usingconvert to strain inbuilt functions present in block diagram VI and was stored in thesystem for indication in the front panel VI. The true value of strain was also calculatedusing physical dimensions of cantilever. Variations of mass versus indicated & calculatedstrain are as shown in Figure 9. 300 Bridge Excitation Voltage =2.5V 250 Indicated Strain Calculated strain 200 Micro strain 150 100 50 0 0 100 200 300 400 500 Mass in milli grams Figure 9 Variation of mass versus indicated & calculated strain 74
    • International Journal of Advanced Research in Engineering and Technology (IJARET)ISSN 0976 – 6480(Print), ISSN 0976 – 6499(Online) Volume 1, Number 1, July - Aug (2010), © IAEME6. CONCLUSIONS Using Labview strain was indicated as micro strain. The LabVIEW measurementplatform has dramatically reduced test times as results were automatically collected. Thistype of Strain measurement system can be used in closed loop for aerospace andbiomedical applications.ACKNOWLEDGEMENTS The authors thank Siddaganaga Institute of Technology, Tumkur, Karnataka,India, for supporting this research work.REFERENCES[1] Willshire, J., Niewczas,Dziuda, Fusiek, and McDonald,R., February 2004, “Dynamic strain measurement using an Extrinsic Fabry-perot interferometric sensor and an Arrayed Waveguide Grating Device” IEEE Transactions on instrumentation and measurement, VOL.53.No,1.[2] Murray, M., January 1962,what are strain gauges – what can they do?, ISA Journal, Vol9, No.1, , P.30[3] Dally.J.W andRiley,W.F., .Experimental stress analysis, 2nd edition, McGraw-Hill, Kogakusha, 1978.[4] Rajanna,K, Mohan,S and. Gopal,E.S.R 1989.’Thin film strain gauges – An overview”, Indian J. pure and Appl. Physics, Vol. 27, pp 453.[5] Kazi.H, Wild.P.M, Moore.T.N, Sayer.M.,2003. ‘The electromechanical behavior of nichrome(80/20 wt.%) film. Thin Solid Films 337-343, 433[6] Maissel, L. I, Glang, R, “ Hand book of Thin Film Technology”, International Business Macines Corporation Components Division, East Fishkill Facility Hopewell Junction N Y[7] Koski, K., Holsa, J., Ernoult 1996, “ the connection Between Sputter Cleaning and Adhesion of thin solid film”, surface and coatings Technology, 80) 195-199.[8] Liu, C S,. Chen, L.J.,1996 “Effects of Substrate Cleaning and Film Thickness the Epitaxial Growth of UltraHigh Vacuum Deposited Cu Thin Films on (001)Si”, Applied Surface Science, 92,) 84-88 75
    • International Journal of Advanced Research in Engineering and Technology (IJARET)ISSN 0976 – 6480(Print), ISSN 0976 – 6499(Online) Volume 1, Number 1, July - Aug (2010), © IAEME[9] Stephen R J, Rajanna, K, Vivek Dhar, K G Kalyan Kumar, and Nagabushanam, S 2004., “Thin Film Strain Gauge Sensors for Ion Thrust Measurement”, IEEE sensors Journal, Vol. 4, No.3, June.[10] Stephen, R,J., Rajanna, K, Vivek Dhar, K G Kalyan Kumar, and Nagabushanam, S “Comparative performance Study of Strain Gauge Sensors for Ion Thrust Measurement”, conference proceedings Vol. 3-1 pp121-126[11] National Instruments SCC-SG Series Strain gage Modules User Guide[12] National Instruments Data Sheet H.M.Kalpana working as assistant professor in the dept. Department of Instrumentation, Siddaganga Institute of Technology, Technology, Tumkur. She has completed her Graduation in Instrumentation & Electronics from Bangalore university and MTech in Industrial Electronics from Mysore university. She is currently pursuing her PhD in thin film sensors under Visvesvaraya Technological University, Belgaum. R John Stephen was born in Tiruchirapalli, Tamilnadu, India, in 1957. He received B.E. degree in Electronics and Instrumentation in the year 1982 from Annamalai university. After staying in industries for a period of about two years he joined as Lecturer, Siddaganga Institute of Technology (SIT), Tumkur, Karnataka, in the year 1984. He obtained M.Tech degree in Instrumentation technology from Indian Institute of Science (IISc), Bangalore, India, in the year 1988 & PhD degree from the IISc, Bangalore in the year 2006. At present he is an professor & HOD in the department of Instrumentation, SIT, Tumkur. He has publications both in National as well as in International Journals. 76