Cyber-secure     Data And Control Cloud              for Power GridsMarcel Mampaey, C-DAX Project CoordinatorNovember 8th,...
A Cloud Overlay for Smart Energy Applications                                                                             ...
A Holistic Approach to Energy Grids• The future grid requires a secure distributed control and  data overlay network (on t...
…in combination with a pervasive, distributedmedium voltage synchrophasor sensing layer  • Allow ‘MV’ operator to capture ...
Overall Architecture      Applications C-DAX: Secure DataDissemination & Control                                          ...
C-DAX Design Concept                                                      Applications                                    ...
C-DAX: an Implementation Project• Capture Requirements for C-DAX  derived from Smart Grid Application Use Cases  - Medium ...
C-DAX Communication• Dissemination  - Targeted conferences / events and publications    (IEEE GreenCom, IEEE Communication...
C-DAX Project ConsortiumKey data   • Duration: 36 months           • Total budget: 4.315.303 Euro           • EU-funding: ...
ContactMarcel MampaeyAlcatel-LucentCorporate Chief Technology Office+32 32 40 98 03marcel.mampaey@alcatel-lucent.comCyber-...
Upcoming SlideShare
Loading in...5
×

iMinds the conference 2012: Marcel Mampaey

196
-1

Published on

Published in: Technology
0 Comments
0 Likes
Statistics
Notes
  • Be the first to comment

  • Be the first to like this

No Downloads
Views
Total Views
196
On Slideshare
0
From Embeds
0
Number of Embeds
0
Actions
Shares
0
Downloads
1
Comments
0
Likes
0
Embeds 0
No embeds

No notes for slide

iMinds the conference 2012: Marcel Mampaey

  1. 1. Cyber-secure Data And Control Cloud for Power GridsMarcel Mampaey, C-DAX Project CoordinatorNovember 8th, 2012 EC FP7-ICT-2011-8 call project COPYRIGHT © 2012 ALCATEL-LUCENT. ALL RIGHTS RESERVED.
  2. 2. A Cloud Overlay for Smart Energy Applications Utility Retailers End-users IP Network Producers Storage systems 2 COPYRIGHT © 2012 ALCATEL-LUCENT. ALL RIGHTS RESERVED.
  3. 3. A Holistic Approach to Energy Grids• The future grid requires a secure distributed control and data overlay network (on top of IP)• Designed to support a whole spectrum of grid applications (unlike today’s silo’s): - From off-line to time-critical data capturing with limited data exchange, using P2P communication, message broadcast/multicast/… - Reaches into the core grid but can seamlessly be extended to include residential end-points - Design takes into account the stringent cyber-security requirements that are expected from the grid as a critical infrastructure - Design takes into account scalability, self-healing and autonomous operation - Allows multiple administrative domains to gain access to the grid fully respecting the business roles in the market 3 COPYRIGHT © 2012 ALCATEL-LUCENT. ALL RIGHTS RESERVED.
  4. 4. …in combination with a pervasive, distributedmedium voltage synchrophasor sensing layer • Allow ‘MV’ operator to capture the real-time state of its network • This full medium voltage smart grid control enables: - Integration of high level renewables - Islanding, Microgrid - Advanced Fault Management C-DAX overlay + breakthrough PMU* technology provides the utility a complete view and control over its his network - anytime, anywhere * PMU = Phasor Measurement Unit 4 COPYRIGHT © 2012 ALCATEL-LUCENT. ALL RIGHTS RESERVED.
  5. 5. Overall Architecture Applications C-DAX: Secure DataDissemination & Control Market Data models CIM Enterprise C-DAX Operation Station 61850 Field Process Generation Transmission Distribution DER Customer CIM = Common Information Model = IEC 61970-301 61850 = IEC 61850 (SCL – Substation Configuration Language) 5 COPYRIGHT © 2012 ALCATEL-LUCENT. ALL RIGHTS RESERVED.
  6. 6. C-DAX Design Concept Applications API Publish / Subscribe based middlewareEnd-users Other Streaming-based Data Query-based Data Point-2-Point Stakeholders Dissemination Secured Grid Overlay Network (unicast, multicast, broadcast) TCP/UDP IP LV MV PV LV S/S G G MV S/SPV = Photo-Voltaic LV = Low VoltageS/S = Sub-Station MV = Medium Voltage 6 COPYRIGHT © 2012 ALCATEL-LUCENT. ALL RIGHTS RESERVED.
  7. 7. C-DAX: an Implementation Project• Capture Requirements for C-DAX derived from Smart Grid Application Use Cases - Medium voltage (MV) distributed energy resources (DER) and Microgrids - Market retail transactions - Low Voltage pervasive DER• Design (iteratively) and architect C-DAX based on requirements• Implement a prototype (& functional testing)• Validate prototype and assess performance (& simulations)• Lab experiment (realtime emulation lab - integrates field equipment)• Field trial in a life electricity network (Alliander MSLivelab) with selected applications 7 COPYRIGHT © 2012 ALCATEL-LUCENT. ALL RIGHTS RESERVED.
  8. 8. C-DAX Communication• Dissemination - Targeted conferences / events and publications (IEEE GreenCom, IEEE Communications Magazine, IEEE PES-ISGT, etc.)• Standardization - Influence relevant standards (IEC 61850, IEEE C37.118, M490, IEC TC57, ETSI M2M, Cigre, IETF)• Collaboration with other projects• Dissemination on public Web site - cdax.eu / cdax-project.eu (will be available by end December 2012)• User Board - Early dissemination of results to a select group of industry players - Meetings organized at key project milestones 8 COPYRIGHT © 2012 ALCATEL-LUCENT. ALL RIGHTS RESERVED.
  9. 9. C-DAX Project ConsortiumKey data • Duration: 36 months • Total budget: 4.315.303 Euro • EU-funding: 2.931.000 Euro • Started: October 1st, 2012 9 COPYRIGHT © 2012 ALCATEL-LUCENT. ALL RIGHTS RESERVED.
  10. 10. ContactMarcel MampaeyAlcatel-LucentCorporate Chief Technology Office+32 32 40 98 03marcel.mampaey@alcatel-lucent.comCyber-secure Data And Control Cloud for Power GridsEC FP7-ICT-2011-8 call project 10 COPYRIGHT © 2012 ALCATEL-LUCENT. ALL RIGHTS RESERVED.
  1. A particular slide catching your eye?

    Clipping is a handy way to collect important slides you want to go back to later.

×