Electrophoresis ppt.
Upcoming SlideShare
Loading in...5
×
 

Electrophoresis ppt.

on

  • 20,753 views

ppt. by GULAM RAFEY &SAURAV,ON ELECTROPHORESIS

ppt. by GULAM RAFEY &SAURAV,ON ELECTROPHORESIS

Statistics

Views

Total Views
20,753
Slideshare-icon Views on SlideShare
20,750
Embed Views
3

Actions

Likes
6
Downloads
0
Comments
16

1 Embed 3

http://lms.crru.ac.th 3

Accessibility

Categories

Upload Details

Uploaded via as Microsoft PowerPoint

Usage Rights

© All Rights Reserved

Report content

Flagged as inappropriate Flag as inappropriate
Flag as inappropriate

Select your reason for flagging this presentation as inappropriate.

Cancel

110 of 16 Post a comment

  • Full Name Full Name Comment goes here.
    Are you sure you want to
    Your message goes here
    Processing…

110 of 16

Post Comment
Edit your comment

    Electrophoresis ppt. Electrophoresis ppt. Presentation Transcript

    • ELECTROPHORESIS Beckmann column chromatography instrumentGuided by ByMr. Saurabh Pandey Saurav Ghoshal Gulam Rafey M.Pharm (Pharmaceutics) PSIT 1
    • Electrophoresis 2 The term literally means “migration withelectricity.” It involves the separation of components of asample by the differential rate of migration ofions by attraction or repulsion in an applied dcelectric field. The technique was first developed by ArneTiselius in 1930s for the study of serum proteins.
    • Why Electrophoresis 3 The process has exhibited unparalleledresolution in the separation of charged species. Electrophoresis may separate between thepolynucleotides which may differ by may be a singleor just a few nucleotides. The Human Genome Project was possible onlyas a result of electrophoresis.
    • Types of Electrophoretic techniques 4Electrophoretic techniques may be of two typesA) Electrophoresis-Slab electrophoresis-TLC-Capillary electrophoresis-ColumnB) Electrochromatography
    • Principle 5 The principle involved in both slab and capillaryelectrophoresis are same which involveselectrophoretic mobility of the ions. It has been found that the migration velocity(v)(cms-1)of a molecule in an electric field is given by v=µeEwhere E=strength of electric field(Vcm-1) µe=electrophoretic mobility (cm2V-1s-1)
    • 6The value of (E) depends upon The charge of the analyte ion The frictional retarding forces which includes Size and shape of the ion Viscosity of the medium in which migration occurs
    • Plates 7The plate count in electrophoresis is given by the formulaN=µeV/2DWhere V=applied voltage D=diffusion coefficent of the solute(cm2s-1) Because the capillary has a small cross sectional area and longer length when compared with that of a slab and hence has much higher resistance when compared to that of a slab. Thus in the capillary format much higher voltages may be applied than in the case of slab which is of greater advantage.
    • Electroosmotic Flow (EOF) 8 An important feature of CE is the bulk flow of liquid through the capillary this is called the electroosmotic flow and is caused as follows. Silica capillary walls contain surface silanol(Si-OH) groups and these are ionized at pH values higher than 3 and the wall becomes (-)vely charged. Wall attracts cations and double-layer forms Cations in the diffuse layer are attracted towards cathode and migrate in that direction as they are in solution the buffer fluid is also dragged along with them. The direction of flow of EOF may be reversed by treatment with cetyl trimethylammonium bromide.
    • Formation of double layer for electroosmotic flow 9
    • Net result of electrophoretic and electroosmotic flow 10
    • Flow Profile in Electroosmotic flow 11A key feature of EOF is that it has flat flow profile, which is shown in Figurealongside the parabolic flow profile generated by an external pump, as used forHPLC. EOF has a flat profile because its driving force (ie., charge on the capillary wall)is uniformly distributed along the capillary, which means that no pressure dropsare encountered and the flow velocity is uniform across the capillary. In HPLC, in which frictional forces at the column walls cause a pressure drop across the column, yielding a parabolic or laminar flow profile.The flat profile of EOF is important because it minimizes zonebroadening, leading to high separation efficiencies that allow separationson the basis of mobility differences as small as 0.05 %.
    • Slab electrophoresis 121. porous layer 2-10 cm long - paper, cellulose acetate, polymer gel soaked in electrolyte buffer2. Slow3. simple but difficult to automate4. poor quantitation5. large quantities (mL)6. large cross-sectional area, short length leading to low electrical resistance, high currents7. Vmax=500 V8. N=100-1000 low resolution
    • Slab Electrophoresis 13
    • Slab Electrophoresis 14
    • Capillary Electrophoresis 15 Electrophoresis in buffer filled, narrow-bore capillaries. Each capillary is about 25-100 μm in internal diameter. Small cross-sectional area, long length leading to high resistance, low currents Vmax=20-100 kV N=100,000-10,000,000 high resolution
    • Contd... 16 When a voltage is applied to the solution, the molecules move through the solution towards the electrode of opposite charge. Depending on the charge, the molecules move through at different speeds. Thus separation is achieved. A suitable detector is then used to detect the solute as it comes out from the end of the capillary. The data obtained are analyzed by a computer and represented graphically.
    • Line Diagram of instrumentation 17
    • Instrumentation 18
    • Instrumentation - Capillary 19The length varies but normally 30-100 cm.Internal diameter (10-100µm).Small bore and thickness of the silica play a role.Using a smaller internal diameter helps prevent Joule Heating, heating due to voltage.
    • Capillaries (Column) 20The capillaries are normally made of fused silica as in the case of Gas chromatography Open Columns.The column is coated with polyimide to improve the durability.Glass and Teflon have also been used but silica provides best functionality.These may be made hydrophobic by the incorporation of alkyl groups which would shield the silanol groups and thus reduce electroosmotic flow.
    • Injection 211.Remove anode end capillary from buffer.2.Place end of capillary in sample.3.Injection volume ranges from 5-50nl. While values as low as 100pl have been reported.3.Apply field for short time (electrokinetic injection)discriminates against low migration rate analytes or apply pressure for short time (pressure injection) or place the sample chamber at a higher level (Siphoning).4.Replace in buffer.
    • Detector 22 UV/Visible absorption Fluorescence Radiometric (for radioactive substances) Mass Spectrometry Electrochemical  Conductivity  Amperometry  Potentiometry Indirect Detection
    • Detectors used and their limits of detection 23Type of detector LOD (attomoles)Absorption 1-1000Fluorescene 1-0.01Mass 1-0.01Conductivity 100Potentiometry 1Amperometry 0.1
    • Detector Cells 24 a) 3 mm Z cell b) 150 µm bubble cell c) Multireflection cell
    • Variants of CE 25Capillary Zone ElectrophoresisCapillary Gel ElectrophoresisCapillary Isoelectric FocusingCapillary IsotachophoresisMicellar Electrokinetic Chromatography
    • Capillary Zone Electrophoresis 26 In this the buffer composition is constantthroughout the region of the separation. Here the anions/cations when allowed to migrate inthe field towards the anode and cathode respectivelytend to be separated into bands which may be separate ormay overlap depending upon the migration velocity. The method may be used for both ions as well asderivatized molecules. Frequently used for separation of mixtures ofcations and anions. Synthetic herbicides, Pesticides,pharmaceuticals may be separated and analyzed afterderivatization.
    • Zone Electrophoresis 27
    • Capillary Gel Electrophoresis 28 It is generally performed in porous gel formed by a polymer matrix. The polymer used is normally Polyacrylamide ( monomer Acrylamide CH2=CH-CO-NH2) The gel used adds an additional component of sieving (size) into the separation process. Other gels used includeAgarosePolyethylene GlycolMethyl CellulosePolyvinyl AlcoholDextranPolydimethylacrylamide, etc.. The method finds most frequent application in DNA sequencing.The columns used may be of two types Low viscosity gels-replaceable High viscosity gels-fixed
    • Sieving Action 29
    • Capillary Isotachophoresis 30 In this process all analyte bands ultimately migrate at thesame velocity. In this the sample is injected between two buffers , aleading one containing ions of higher mobility than any of theanalyte ions and a terminating one with ions of mobilty lowerthan the analyte ions. At the beginning of the separation procedure all the ionsmigrate at the different velocities and then as there isseparation the faster moving electrons experience a weakerelectric field as compared to that of the slow moving electronsand thus are retarded. As this process of retardation based oncharge differences reaches equilibrium each of the bands areseparated on the basis of their migration rates. Markers may be added between bands to separate them.
    • Isotachophoresis 31
    • Capillary Isoelectric Focussing 32 In this technique the separation of amphiprotic substances can be performed in a buffer soln. whose pH varies along its length. In this procedure one end of the capillary bearing the cathode is dipped in a soln. of strong base (NaOH) and the end bearing anode is dipped into a soln. of a strong acid (H3PO4). + When the process starts the H ions migrate towards the cathode - and the OH migrates towards the anode, thus establishing a pH gradient, with higher pH towards anode. The analyte in combination with some other ampholytes (contain carboxylic and amine gp.) is also introduced in the sample and these migrate on the basis of their charge and during migration they may be protonated or lose proton depending on the direction of migration due to the existing pH gradient, the migration continues till the pH region where the ion has reached is equal to the pI and at this point the analyte or ampholytes becomes neutral. Once this occurs several sharp bands are formed and no further migration occurs.
    • Contd.. 33The bands may then be mobilized by adding NaCl to - base end and then this leads to less migration of OH and then the pH gradient is disturbed leading to migration of the soln. towards the cathode leading to the detection of the bands.
    • Capillary Isoelectric Focussing 34 Theoretical separation of compounds with varying pI
    • Micellar Electrokinetic Chromatography 35• Earlier, neutral molecules were not considered to be separated by electrophoresis• In 1984, Terabe and his group reported a technique that enabled capillary electrophoresis (CE) instrumentation to be used in the separation of neutral (as well as ionic) species=MEKC MEKC is primarily used for separation of neutral analytes but is also used for separation of ionic analytes• In this system, micelles are described as “pseudo-stationary phase” and the buffer as “mobile phase”=system for partitioning of analytes• When micelles are not present, neutral molecules will migrate with the electroosmotic flow and no separation will occur.• MEKC has the capability of separating, within a single run, anionic, neutral, and cationic species.• The micellar solution is divided into 2 flow preferences. The aqueous buffer has a strong flow toward the cathode (EOF) and the micelles are slowed down because they have anionic character and due to electrophoretic mobility they are attracted towards the anode.
    • Contd.. 36• The EOF is much stronger than the electrophoretic mobility, the solution is all headed toward the cathode, but the micelles head at a much slower rate because they are attracted to the anode on the opposite side.• The negatively charged species are repelled by the anionic micelle while the positively charged species are attracted to the micelle; because the micelle elutes later than the buffer, so do the positively charged species which are attracted to it The more negatively charged species - more repelled by micelle than the less negatively charged species (elute earlier) The more positively charged species - more attracted (strong electrostatic interaction) to the micelle than the less positively charged species (elute later with the micelle) The neutral species migrate between the two extremes and their separation is based on hydrophobicity
    • PACKED COLUMN ELECTROCHROMATOGRAPHY 37 Electrochromatography is a hybrid of HPLC & CE that factor offers some of the best features of the two methods. Like HPLC & MEKC, it is applicable to the separation of neutral species or charged species. In electrochromatography, a polar solvent is usually driven by electroosmotic flow through a capillary packed with a reversed-phase HPLC packing. Separation depend on distribution of the analyte species between the mobile phase and the liquid stationary phase held on the packing.
    • Field Flow Fractionation 38This separation technique involves the separation of the components of a mixture during its flow through a ribbon like channel by the application of a thermal, electrical, centrifugal or flow field. As the components migrate through the channel the channel the applied field in perpendicular direction leads to the accumulation of the particles at the bottom known as accumulation wall.
    • Field Flow Fractionation 39
    • Contd.. 40The ribbon like channel has following dimensions Length 25-100 cm Width 1-3 cm Thickness 50-500 µm Depending on the type of applied field it may be of four types:ThermalElectricalSedimentationFlowApplication- Mainly for particles of high mol. mass and neutral particles.
    • Applications 41 The vast applications of electrophoresis include Vaccine analysis. Protein and DNA analysis are also important electrophoresis applications. It has allowed researchers to map and see the differences in the genetic code of species on earth. Electrophoretic DNA analysis also provides a reliable tool in forensic investigations. Determination of impurities. Chiral Analysis. Analysis of carbohydrates and other macromolecules. Analysis of inorganic anions/metal ions.
    • Vaccine Analysis 42Vaccine analysis is one of the many important applications of electrophoresis. There are several vaccines that have been purified, processed and analyzed through electrophoresis, such as the influenza vaccine, hepatitis vaccine and polio vaccine.Manufacturers such as Wyeth, Merck and Sanofi- Aventis have been using electrophoresis as an effective vaccine analysis method.
    • DNA Analysis 43 Electrophoresis is one way of analyzing DNA, which is the unique code ofevery individual. Through electrophoresis, specific DNA sequences can be analyzed,isolated and cloned. The analyzed DNA may be used in forensic investigationsand paternity tests. For this wells are formed at one end of an agarose gel for the loading ofthe DNA sample. The slab is then placed horizontally into the electrophoresisbuffer chamber The DNA migrates in bands toward the positive electrode. Thesmaller molecules pass through the matrix more rapidly than the larger ones,which are restricted. The DNA bands are then stained using a fluorescent dyesuch as ethidium bromide. The stained gel is then viewed directly underultraviolet light and photographed. Another technique for detection involves the use of different fluorescentdyes which tend to bind to the bases of nucleotides and thus give unique stainingprofile
    • Protein Analysis 44Electrophoresis has advanced our understanding on the structure and function of proteins. These molecules are needed by our body cells and may be analyzed, for instance, by getting blood and urine samples. Then through electrophoresis, the amount of proteins in your blood or in your urine is measured and compared to established normal values---lower or higher than the normal levels usually indicates a disease.
    • Assay of Drugs 45Atropine sulphate i.v. soln.Codeine phosphate syrupKetamine HCl i.v.soln.Phenylepherine HCl i.v. soln. have sucessfully been assayed by this process.
    • 46