PGP Business: All buildings should be well

325 views

Published on

Presentation Dossier of the office building PGP Business.

More information at http://www.pgp.cat

Published in: Real Estate, Business, Travel
0 Comments
0 Likes
Statistics
Notes
  • Be the first to comment

  • Be the first to like this

No Downloads
Views
Total views
325
On SlideShare
0
From Embeds
0
Number of Embeds
5
Actions
Shares
0
Downloads
1
Comments
0
Likes
0
Embeds 0
No embeds

No notes for slide

PGP Business: All buildings should be well

  1. 1. All buildings should be well ... BUILDING
  2. 2. THE BUILDING THE BUILDING All buildings should be well ...2 floors of parking, ground floor commercial and office with 1,300 square meters of courtyard THE BUILDING BUILDING Ctra. de València (N-340a), 224 43007 TARRAGONA
  3. 3. THE BUILDING The area inside 13.577,60 m² Outdoor living area 1.293,35 m² Floor area All buildings should be well ... 14.182,25 m²2 floors of parking, ground floor commercial and office with 1,300 square meters of courtyard The building itself is a rectangular 50.64 x 76.40 m. located 12 m. the northern boundary of the plot, playing the N-340a, with access width of 12 meters east and west, leaving a free zone for south park. It comprises two basement floors for parking meters 3868.90, a ground floor of the same dimension as the basement consists of a transparent area of 3633.10 sqm of floor space and vertical communication cores and a plant consisting of offices Edge ring 12.66 m. width and an area of 2575.55 square meters with an inner courtyard of 1293.35 meters. For your height, this plant has broad views from all exterior walls to round him from the facades can be seen inside the courtyard of ample dimensions (51 x 25 m.). Taking advantage of the natural slope of land, this has been divided into two levels, one north, where the building is available, and a lower one to the south to the parking lot outside, and from where you access the underground car park, the NATO-open 1tiene south facade at this level. BUILDING
  4. 4. Beautiful location very close to major axes of Location and communications communication The building is located in a prime location.All buildings should be well Walk the N-340, one of the main communication routes of Tarragona, has the advantage of easy access, from the same road from Valencia, as from Tarragona and Salou. The brewed not have to get to downtown and find parking or proximity to major nucleos of communication as are the airport, port, highway or the train AVE constituyen also points soon to the deposit location of this new immueble , under construction which also lies a few kilometers from Reus and Vila-seca Next construction distances: Tarragona (city center) 2 km Reus 11 km Vila-seca 6 km Port de Tarragona 2 km Aeroport de Reus 5 km del Camp Station(AVE) 12 km (Centro) (Centro) Central future central (AVE) 5 km Salou 10 km Barcelona 93 km Direction: Ctra. de Valencia (N-340a), 224 València 250 km Lleida 94 km More information:
  5. 5. Beautiful location very close to major axes of Location and communications communicationAll buildings should be well å More information:
  6. 6. Beautiful location very close to major axes of Ground and building plot communicationAll buildings should be well More information:
  7. 7. Beautiful location very close to major axes of Views of the building communication Main facade (N-340a)All buildings should be well Rear facade Side facade More information:
  8. 8. Beautiful location very close to major axes ofAll buildings should be well Views of building interiors communication More information:
  9. 9. Beautiful location very close to major axes of Building connected to the future communication Facilities more than 200 points yesterday. The building electrical cumple de Baja Tensión the Regulation and its complementaryAll buildings should be well directions, as well as the Rules vigente so respected in the installation of plumbing and S A N E A M I E N T O . With regard to the telecommunications, building comprises Setup Phone General upon Royal Decree 401/2003. He has written the amount Draft Infraestructuras shared telecommunications (ICT). Setup Emergency crews covering the protection of facilities for contraindendios Dar sent to CTE DB YES: portable extinguishers, fire nozzle, alarm system and emergency lighting. The climate of the offices is obtiene mediante Provision of technical floors and ceilings heat pump, with 16 units spread uniformemente d i s p o s a l . The total usable space available technical floors Setup covering the renovation of the ventilation and ceilings with lighting technicians isophone air inside the plant and offices mediante installed. These building blocks facilitate the Conductos acceptance of mechanical distribution of users when making connections to ventilation for mining located in the false ceiling, computer hardware and allow the passage of and with the departures and entrances located the necessary facilities. in the pool, in agreement with the CTE DB HS 3 More information:
  10. 10. Beautiful location very close to major axes of Accessibility communication The building gives compliance to the Codi Moreover, the building also has four chambers Accessibility: is framed within the group of adapted for handicapped hygiene (2 men and offices open to the public of over 500 meters, so 2 women). In these, the mirrors are tilted for easy viewing from a wheelchair, while the soap andAll buildings should be well the routes, lifts and ladders are adapted. In this sense, the three parking areas available to the paper are at an accessible distance, and the building have suitable places to people with sink, which is free for the bottom for easy minisvalías. These spaces are closest to the wheelchair access . elevators, stairs while also adapting to the disabled guests, by expressly distance between rungs below for ease of use. More information:
  11. 11. All commercial areas should be wellAn open space with easy parking, good transport links and with many possibilities BUILDING
  12. 12. The area inside All commercial areas should be wellAn open space with easy parking, good transport links and with many possibilities The ground floor has two vertical Comuniación nuclei that have a total built area of 152.82 square meters. Each of them consists of lobby, elevator, 12 places, straight out of the parking and access stairs to first floor. Adjacent to the lobby cameras are placed throughout the building facilities (with direct input from the outside). As for the shopping center, the core this (facing the city) is the chief, and is finished with fine materials. It has a width of 3 m. and has automatic doors at the entrance. The western nucleus has a width of 2 m. and functions as an alternative entrance and emergency exit. BUILDING
  13. 13. Beautiful location very close to major axes ofAll businesses should be well Views commercial plant communication More information:
  14. 14. Beautiful location very close to major axes ofAll businesses should be well Commercial plant distribution communication More information:
  15. 15. PLANT OFFICES PLANT OFFICES All offices should be well2,700 m² of offices divisible into 16 modules of 169 meters with an interior courtyard of 1,300 m² PLANT OFFICES BUILDING
  16. 16. PLANT OFFICES The area inside Plant divisible into All offices should be well 16 modules2,700 m² of offices divisible into 16 modules of 169 meters with an interior courtyard of 1,300 m² The office floor has a total constructed area of 2575.55 sq meters and consists of a transparent area of 2224.15 square meters of floor space, and two service cores m² of floor space 103.50 each consisting of lobby, lift, level access and toilet facilities (the male has 2 WCs, 1 adapted toilet, 3 urinals and three toilets, the women have 4 WCs, 1 toilet adapted and 4 toilets). From the lobby you access the outdoor courtyard, with a usable area of 1293.35 square meters. From the patio access to the offices through 16 doors (4 on each side). The renovation of the indoor air ventilation is achieved by taking into account that the openings are fixed. This system allows the plant sectorize, since they have provided 16 inputs and 16 outputs of air evenly distributed. The air conditioning is particular sector, as there is a possibility of having up to 16 units distributed evenly. The quality of the glass enhances the thermal losses and solar are minimal involvement. BUILDING
  17. 17. Beautiful location very close to major axes ofAll offices should be well Plant having offices communication More information:
  18. 18. Beautiful location very close to major axes of Distribution office floor communication Example of partitioning the maximum possible: 16 offices.All offices should be well Acceso servicios Acceso principal More information:
  19. 19. PARKING PARKINGAll car parks should be well 2 floors of parking with 148 spaces per floor PARKING BUILDING
  20. 20. PARKING PLACES 296 spaces Covered parking All car parks should be well more than 118 spaces Outdoor parking 2 floors of parking with 148 spaces per floor Consisting of two floors, with 148 seats each, the two parking levels are connected with each other and the upper floors with 2 lifts. The parking meets the code Accecibilidad and has 8 adapted spaces (4 per floor), with maximum proximity to pedestrian access, are duly marked. have minimum size and have access as provided in paragraph 2.4.1 of Annex 2. In addition, the land annexed to the building has an outdoor parking lot located to the south, with 118 seats. BUILDING
  21. 21. Beautiful location very close to major axes ofAll building should be well A building connected with the future communication More information:
  22. 22. Beautiful location very close to major axes ofAll building should be well Distribution basement -2 communication Acceso aparcamiento More information:
  23. 23. Beautiful location very close to major axes ofAll building should be well Distribution basement -1 communication Acceso aparcamiento More information:

×