Lighthouse Overview Presentation Linkedin2
Upcoming SlideShare
Loading in...5
×
 

Lighthouse Overview Presentation Linkedin2

on

  • 1,072 views

Lighthouse Worldwide Solutions Overview Presentation

Lighthouse Worldwide Solutions Overview Presentation

Statistics

Views

Total Views
1,072
Views on SlideShare
1,071
Embed Views
1

Actions

Likes
0
Downloads
7
Comments
0

1 Embed 1

http://www.linkedin.com 1

Accessibility

Categories

Upload Details

Uploaded via as Adobe PDF

Usage Rights

© All Rights Reserved

Report content

Flagged as inappropriate Flag as inappropriate
Flag as inappropriate

Select your reason for flagging this presentation as inappropriate.

Cancel
  • Full Name Full Name Comment goes here.
    Are you sure you want to
    Your message goes here
    Processing…
Post Comment
Edit your comment

Lighthouse Overview Presentation Linkedin2 Lighthouse Overview Presentation Linkedin2 Presentation Transcript

  • Lighthouse Worldwide Solutions
  • Our CEO: Winner Best Places to Work in Bay Area Silicon Valley Best Places to Work 2 Years in a Row 2005, 2006!
  • R&D / HQ: Manufacturing Medford, OR Manufacturing Operations Service & Repair Center Central Calibration Lab RMA CenterMedford, OR Fremont, CA Research & Development Engineering Pilot Production Executive Management Fremont, CA
  • New Headquarters: Silicon Valley
  • Lighthouse Focus on QualityISO 9001:2000 Facilities United States: The Medford, OR Netherlands: Singapore Thailand San Jose, CA Alphen 5 Lighthouse Locations are ISO 9000 Registered
  • Monitoring Solutions General Monitoring Specific Applications  Air/Liquid/Gas Particle  Current on FFU’s Temperature/Humidity  Chillers  Air Velocity  Door Switches  Differential Pressure  Oven Temp  Electrostatic Charge  Dry Box Humidity  TOC  Gas Purity  Large LCD Displays
  • Process and Environmental Monitoring
  • Process Monitoring • Sample locations as close as possible to the critical process areas to help correlate high counts to yield issues.
  • Environmental Monitoring  Temperature/Humidity Sensors  Room  Ovens  Freezers  Differential Pressure  Room to Room  Mini Environment  Air Velocity  Cleanroom  Ducts
  • Environmental Monitoring TRH Sensor Humidity Inside Fridge APC DP TRH Air Particle Velocity Multiple DP Sensors Air Velocity in Duct
  • Environmental Monitoring Replace your Magnahelic Pressure Sensors Air Velocity in a Duct Monitor Air Velocity in Ducts
  • Environmental Monitoring Incubator Fluid or Tank Temperature Levels Dry Box Humidity and Particle
  • Leak Detection  Real Time Leak Detection  Analog Signal
  • Power Monitoring  Voltage Monitoring  Current Monitoring  Split or Solid Core  4 – 20mA Output
  • Particle Monitoring in Ducts  0.2 to 100 Micron  Early Warning System  Immediately Notification of Catastrophic Failure
  • Lab Monitoring
  • Lab Monitoring
  • Lab Monitoring Transmitter  Replacing Chart Recorders  Temperature Thermocouple
  • Refrigerator/Freezer  Replacing Chart Recorders  Temperature Local Display Dual Transmitter
  • Tank Levels and Status Cryo Tank  LN2 Tank Level  LN2 Tank Lid (Open/Closed)  LN2 Bulk Tank Level  Co2 Tank Level  Oxygen Sensor
  • Differential Pressure  Differential Pressure  4 – 20mA Output  Gown Room Pressure  Cleanroom Pressure
  • Incubator  Temperature  Humidity  C02  Door is open/closed
  • HVAC System  HVAC Status  Temperature  Power Consumption
  • Power Monitoring  Voltage Monitoring  Current Monitoring  Split or Solid Core  4 – 20mA Output
  • Lab Monitoring Alarm Light APC in Flow Bench Differential Pressure Wireless Temp inside Temp/Hum Incubator APC in Flow Bench APC in Flow Bench
  • Wireless Considerations: Wireless Temp Sensor with Internal Probe  Building Construction Wireless Temp/Humidity  Installation (inside or outside) Particle Sensor with External Probe  Distances  Sampling Frequency Wireless Converter (4 – 20mA to Wireless)  Response Time  Battery Life vs. PoweredDifferential ReceiverPressure
  • Power Savings
  • Power Savings  Typical Flow Rates 70 – 120 FPM Reduced Air Changes = Power Savings Particle Counters Used to Verify Performance Particle Count Data is fed back to HVAC system VFD is required for FFU or HVAC system
  • Power Savings Air Velocity and Particle Data  Step 1: Verify room performance through certification Step 2: Select optimum sample locations (Critical and Busy Sampling) Step 3: Lower FFU speed and monitor for an increase in particle counts. Step 4: Set new acceptable air flow rate based on testing Step 5: Set alarming parameters Step 6: Install the system
  • ProductsSlide 30 Lighthouse Worldwide Solutions CONFIDENTIAL
  • Lighthouse Family of Products World’s Number One Particle Counters!Slide 31 Lighthouse Worldwide Solutions CONFIDENTIAL
  • Airborne Particle Counting
  • Particle Counters: HANDHELD * Handheld 2016 Touch Screen Interface * Handheld 3016 * Handheld 5016 * Handheld 3016 IAQ Removable Battery Temp/Hum Probe
  • Portable Particle Counters: SOLAIR SOLAIR 5100 / 3100 0.5 / 0.3 Micron 1.0 CFM Touch Screen Interface SOLAIR 5200 / 3200 0.5 / 0.3 Micron 2.0 CFM or 50 Liters per Minute Removable Battery SOLAIR 1100LD 0.1 Micron 1.0 CFM Alphanumeric Location Labels
  • Portable Particle Counters: SOLAIR Boulder Counter 0.5 to 100 Micron 1.0 CFM Easy to Use Interface SOLAIR 5350 / 3350 0.5/0.3 Micron 3.5 CFM or 100 Liters per Minute Sample Setup Historical Data Review
  • SOLAIR 1100LD GSO (Gas Sampling Option) 8 Particle Channel Sizes Wide Dynamic Range, 0.1 to 5.0 µM Battery Powered Customizable Gas Sampling Recipes 3,000 Sample Records May be Used with Any Inert Gases Auto Flow Rate Compensation ensures accurate measurement Gases Sampled: Argon, Nitrogen, Carbon Dioxide, Helium, CDA, Neon, XenonSlide 36 Lighthouse Worldwide Solutions CONFIDENTIAL
  • Particle Counters: REMOTE Remote 2010/3010/5010 0.2/0.3/0.5 Micron Detection 0.1 CFM Air Flow Pulse Communication Remote 2012/3012/5012 0.2/0.3/0.5 Micron Detection 0.1 CFM Air Flow 0.1 Analog (4 -20mA) Communication
  • Remote 5104P / 3104P Remote Particle Counter w/Pump Supports Remote Display Interface: USB, RS-485 or Ethernet HEPA Filter Cooling Fan Exhaust and Pump Exhaust Interface with Manifold  32 Port  6 Port Reduced Cost for Manifold SystemsSlide 38 Lighthouse Worldwide Solutions CONFIDENTIAL
  • Remote 5104PN / 5102PN Remote 5104PN: Modbus Remote 5102PN: 4-20mA 1.0 CFM (28.3 LPM) Flow Rate Built In Pump Filter Pump Exhaust Pump Start / Stop via Software (5104PN) Stainless Steel Construction 316L Wipe-down Enclosure 90-240 VAC Power (50/60Hz) 39
  • Manifolds: Universal Manifold 32 Sample Locations 1.0 CFM Works with Lighthouse and Met One Particle Counters Mini Manifold 6 Sample Locations Fan HEPA / ULPA Filter 0.1 CFM Particle Shedding / 4 Analog Inputs Mini-Manifold Generation & 0.2 Micron Particle Mini Manifold+ Counter 6 Sample Locations 1.0 CFM Mini-Environment Monitoring With Mini-Manifold & Single Particle Counter
  • TOC Monitoring
  • Neptune TOC  Patent Pending UVX Technology  TOC Range: 0.05 ppb to 1000 ppb  Repeatability: <5 ppb, 0.05 ppb; >5 ppb, 5%ppb  Conductivity Range: 0.055 to 2 uS/cm  Resistivity Range: 0.5 to 18.24 MOhm*cm NeptuneTOC - Pharma 21-JUL-2011
  • Neptune TOC  Interfaces Ethernet - MODBUS/TCP Isolated RS232/485 - MODBUS ASCII/RTU Four Channels 4-20mA Output Four Relay Outputs NeptuneTOC - Pharma 21-JUL-2011
  • Neptune TOC  Two Year Warranty  Dimensions: 18.3 x 20.3 x 21 cm [7.2” x 8” x 8.25”]  Weight: 0.21 kg [7.22 lbs.]  Power: 24VDC @ 1.5 Amps  Operating Temperature: 5 to 50 C, 0% to 95% non- condensing Relative Humidity NeptuneTOC - Pharma 21-JUL-2011
  • Liquid Particle Counting
  • Liquid Particle Counting: Online Remote LPC 0.5 Remote LPC 0.3 0.5 – 20 Micron 0.3 – 3.0 Micron 4 Channels 4 Channels 100 mL Flow Rate 100 mL Flow Rate Remote LPC 0.2 Remote LPC 0.1 0.2 – 2.0 Micron 0.1 – 0.5 Micron 4 Channels 4 Channels 100 mL Flow Rate 100 mL Flow Rate
  • Advanced NanoCount 25, 30 and 50  Local Display  Higher Sensitivity  Higher Sample Volume  25nM SensitivitySlide 47 Lighthouse Worldwide Solutions CONFIDENTIAL
  • Liquid Particle Counting: Batch Sampling System
  • Systems
  • Online Systems – Star Configuration 6 Real Time Particle Counters with External Vacuum Pump Real Time Data Hub Software - Ethernet or Modbus Output - Supplies Power to Remotes Power From Data Hub RS-485 MODBUS Vacuum Gauge Vacuum Manifold Optional Items Vacuum pumpAlarm TRH DPLight Sensor Sensor
  • Online Systems- Network Configuration 4 Real Time Particle Counters with Built in Vacuum Pump Over Ethernet Built in Vacuum Real Time Pumps Software ethernet ethernet ethernet ethernet Power ps Power ps Power ps Power ps and Ethernet and Ethernet and Ethernet and Ethernet LAN Optional Items View View Station StationAlarm TRH DPLight Sensor Sensor
  • Online Systems Manifold Sampling System Real Time Up to 32 Sample Ports Software Particle Counter and Data Hub - Ethernet or Modbus Output Sequential Sampling Manifold RS-485 MODBUS Optional ItemsAlarm TRH DPLight Sensor Sensor
  • Online System with Server
  • Online System with Server
  • Portable Cart System  Real time monitoring of multiple locations  Troubleshoot the Process  Identify particle sources quickly  Characterize the process  Qualify the tool
  • Software
  • Ultimate in ScalabilityLMS Professional Monitoring System is designedto scale from a single point to thousands ofpoints and still maintain the same look and feel. Building 1 Central System Building 2 Building 357
  • RedundancyRedundant Data Acquisition (failover)Automatic Recovery (fail-back) No Loss of Existing Calculations, Summations or ProcessesRedundant ClientsNo Operator Intervention RequiredMirrored Historical Data58
  • Data Communication: Wireless Network Wireless Adapter Ethernet Wireless LWS Adapter Wireless Adapter 59
  • Connectivity The Lighthouse Monitoring System is designed to meet all your monitoring needs. Connectivity:  4 – 20 mA  MODBUS  Ethernet  Digital Input  Digital Output  Thermocouple  RTD  OPC
  • Connectivity The Lighthouse Monitoring System can be can send and or receive data from other types of Building Automation, SCADA or Control Based Systems. Common Interface Between Systems Are:  OPC  MODBUS TCP or MODBUS ASCII  Profi Bus LWS  Device Net Database  The database is ODBC/SQL Compliant ODBC SQL Compliant
  • Connectivity
  • Main Screen63
  • Multilevel Maps Unique Sensor ShapesDrill Down Maps allowyou to see an overviewof the facility and thenstatus of a specificroom
  • From Map to Graph Simple Mouse Click Navigation to the Data You Want to See…65 Lighthouse Worldwide Solutions CONFIDENTIAL
  • Logical System Structure
  • List ScreenView All Sensors Status Real Time Color Status Real Time Data Status Location Name Values Date and Time Click n GoSort by Status Acknowledge an Alarm Display a Trend Disable/Enable Alarms Configure Locate a Sensor Lighthouse Worldwide Solutions CONFIDENTIAL
  • SchedulesSetup a scheduled event basedon date and time. Turn on/off a pump Automatically change alarm limits Trigger sampling recipes Print Reports Stop recording data 68
  • Status ScreenView All Sensors Status Real Time Color Status Real Time Data Status Location Name Values Date and Time Current/Historical Graphs Alarm Acknowledgment Click n Go Mouse Click Menu Selection Simplifies Use…69 Lighthouse Worldwide Solutions CONFIDENTIAL
  • Report Function Conformance Report  Raw Data by Channel Size  Color Coded  Summary of Events  # of Measurements  # of Warnings  # of Alarms  Min  Max  Average  Mean  Standard Deviation  Graphs of Selected Points70
  • Simplified DeploymentTemplates and Recipes allow for easy and consistentdeployment of monitoring changes across multiple sites.Export E-mail ImportRemote Desktop Singapore Thailand USA China71
  • DROID Based Application Watch and Receive Your System Information on the go… DROID Powered Phone DROID Powered Tablet 72
  • Installation and Service
  • ISO 21501 Calibration Standards  Improved Reproducibility  Greater Counting Accuracy  Increased Testing to Minimize Errors  Enhanced Correlation between Instruments ISO 21501 Summary:  Size Calibrated  Particle Count Verification  Size Resolution  False Count Rate Verification  Maximum Concentration Limit Verification  Flow Rate Verification  Sample Time Verification  Sample Volume Verification
  • Installation Services  Mounting Styles (Fixed Probes vs. Movable Probes)  Probe Locations  Tool Integrated Probes  Wall Mounted Fixtures  Non-Viable & Viable Probes  Custom Fixtures & Conduits  Getting the utilities to the instrumentation is key  NEMA 4X enclosures
  • Validation Services  Requirements Documents  Design Qualification  Installation Qualification  Operational Qualification  Performance Qualification  SOPs
  • Training Services  Monitoring System Training  User Level  Administer Level  Service  Calibration Training (Optional)  Contamination Training  Cleanroom Protocol Training
  • Contact us at 510-438-0500 or www.golighthouse.comSlide 78 Lighthouse Worldwide Solutions CONFIDENTIAL