Ivf products,Ivf supplier,Fornax Spermfuge,ivf,shivani ivf,india ivf,Shivani Scientific
Upcoming SlideShare
Loading in...5
×
 

Ivf products,Ivf supplier,Fornax Spermfuge,ivf,shivani ivf,india ivf,Shivani Scientific

on

  • 3,397 views

Spermfuge is an improvised centrifuge, dedicated totally for elevating the total motile sperm recovery from the parent semen sample, by controlling/maintaining the main parameter of "Temperature" thus ...

Spermfuge is an improvised centrifuge, dedicated totally for elevating the total motile sperm recovery from the parent semen sample, by controlling/maintaining the main parameter of "Temperature" thus aimed at Enhancing the ART results. The instrument has been designed to regulate and subsequently maintain the "Critical" inner chamber temperature before, after and during centrifugation. Maintenance of this critical temperature throughout the entire sperm processing procedure helps the sperm maintain their peak motility and enhanced linearity. The two of the most vital parameters which act as a yard stick to gauge the effectiveness of an ideal sperm wash. The existing dependency on RPM will be eliminated by on screen g-force selection.

Statistics

Views

Total Views
3,397
Views on SlideShare
3,396
Embed Views
1

Actions

Likes
0
Downloads
14
Comments
1

1 Embed 1

http://www.slideshare.net 1

Accessibility

Categories

Upload Details

Uploaded via as Adobe PDF

Usage Rights

© All Rights Reserved

Report content

Flagged as inappropriate Flag as inappropriate
Flag as inappropriate

Select your reason for flagging this presentation as inappropriate.

Cancel

11 of 1

  • Full Name Full Name Comment goes here.
    Are you sure you want to
    Your message goes here
    Processing…
Post Comment
Edit your comment

    Ivf products,Ivf supplier,Fornax Spermfuge,ivf,shivani ivf,india ivf,Shivani Scientific Ivf products,Ivf supplier,Fornax Spermfuge,ivf,shivani ivf,india ivf,Shivani Scientific Presentation Transcript

    • Technical Specification Temperature Management Centrifugation Details Digital programming via microprocessor control Max rotational speed 2200 RPM in 1.0 C increments.measurement of Rotational speed range 300 to 2200 RPM temperature in chamber via digital sensor. Over Relative centrifugal force 800 g max temperature protection system independent of Acceleration and braking programmable Spermfuge microprocessor control. Rotor capacity 8 x 15 ml Choice of tubes 6ml, 14ml, 15ml Range 2 °C above ambient to 42 °C Control ± 1 °C Electrical supply Stability ± 1 °C Operating Voltage 100 120 Volts 60 Hz uniformity ± 1 °C or 220 240 Volts 50 Hz Power consumption 450 watts max Temperature Regulated Centrifuge specifications subject to change without notice Ordering information SF 800 Spermfuge SF 800 100 120 Volts 60 Hz order code FX 1055 Spermfuge SF 800 220 240 Volts 50 Hz order code FX 1056 Dimensions 385 mm 470 mm 220 mm Traceability calibration in accordance with C For more details go to national and international standards, NIST USA www.shivaniscientific.com Q Individual and expressive quality control certificate Shivani Scientific Industries (P) Ltd Tel - + 91 22 2845 6768 26A Raju Industrial Estate, Penkar Pada Road + 91 22 2845 6769 Near Dahisar Check Naka, Mira-401104 + 91 22 2845 6770 Dist. Thane (Mumbai) Maharashtra, INDIA e-mail sales@shivaniscientific.com Fax - + 91 22 2845 7140 ssipl@bom5.vsnl.net.in + 91 22 2845 6766 Distributor We make it possible Spermfuge SF 800 Temperature Regulated Centrifuge SF 800 Spermfuge ACCELERATION AND BRAKING An adjustable brake is provided to prevent the Temperature Regulated Centrifuge rotor from stopping too quickly at the end of run SF 800 which might cause disturb to the firmly formed pellet. One can select 3 mode in acceleration and braking, slow medium and to fast can be given on screen. CONCEPT OPERATING SECURITY SPERMFUGE is an improvised centrifuge, G FORCE The Vision port in the lead at the center helps dedicated totally for elevating the total motile to confirm rotational speed with a stroboscopic The exact indication of g-force helps the ideal sperm recovery from the parent semen sample, device. The safety interlock in the lead prevents sperm pellet formation by subjecting the sperm by controlling/maintaining the main parameter of accidental opening once the Rotor is operational. to an exact and precise amount of g-force unlike “Temperature” thus aimed at Enhancing the ART The maximum RCF is 800g which prevents other Centrifuges where g-force is subject to RPM results. The instrument has been designed to accidental damage to the sperm. and the tube size. Now a days centrifugation regulate and subsequently maintain the “Critical” speeds are never reported in RPM as those inner chamber temperature before, after and numbers are not useful for any one wanting during centrifugation. Maintenance of this critical to reproduce the method. (Being dependent temperature throughout the entire sperm Rotor radius.) processing procedure helps the sperm maintain their peak motility and enhanced linearity. The two of the most vital parameters which act as a TEMPERATURE AND yard stick to gauge the effectiveness of an ideal sperm wash. The existing dependency on RPM CENTRIFUGATION will be eliminated by on screen g-force selection. The heating range of SPERMFUGE's chamber is from 2°C above ambient to 42°C. The intelligent INTELLIGENT CONTROL SYSTEM DESIGN control system does not allow the centrifugation to State of the art microcontroller with optomagnetic commence till the set temperature is attained. The SPERMFUGE has been designed after taking encoder provides intelligent control system. However, one does have the option to commence into consideration detailed cellular physiological Digital programming via microprocessor control the centrifugation without chamber heating and to demands, locomotion kinetics and pooling for various parameters including temperature, commence the chamber heating without together ideal suggestions, opinions, ideas and RCF and time. The parameters are displayed on centrifugation. propositions of numerous Andrologists and four line LCD display . Embryologists and other professionals in the field ROTOR HEAD AND of Human Reproduction. TUBE SELECTION MULTIPLE PROGRAMS The SPERMFUGE with its Temperature MAINTENANCE SPERMFUGE has a swing out rotor head to controlled chamber ( room temperature to 42° C), The SPERMFUGE facilitates user selectable accommodate 8 tubes maximum of 15 ml. The programmable microprocessor based controls, 9 programs for different applications and also for The SPERMFUGE is virtually maintenance free Sperm Fuge can accommodate 6ml Tubes multiple tube selection, accurate g-force different set of protocols as standardized by since it utilizes brushless drive motor. The motor is (Falcon 2003), 14 ml Tubes (Falcon 2001) and 15 selection, independent centrifugation and/or various clinics, laboratories and regulatry bodies. extremely smooth even during running at the ml Tubes (Falcon 2095). The tube selection can be heating selection and other added advantages The user can select RCF, RPM, Tube Size, maximum speed. The motor is electrically done on screen with the help of the encoder, make it an ideal state of the art instrument for use temperature, time for each program by a digital controlled during the acceleration and breaking which ensures an exact g-force selection. in an ART laboratory. encoder. with smoothness.