VIBRATION OF LIGHTNING PROTECTION CABLES ON RION-ANTIRION BRIDGE
Dr. Panayoti PAPANIKOLAS
Vice-Chairman & Managing Director
GEFYRA S.A.- 2 Rizariou Str., 152 33 Halandri, Greece
Olivier FLAMAND
CSTB – 11 rue H. Picherit, 44300 Nantes – France
Olivier.flamand@cstb.fr
Introduction
The Rion-Antirion bridge is a major cable stayed structure upon the golf of Corinth in Greece. On the
27th
of January 2005, the bridge has been struck by lightning, leading to the failure of one stay cable.
The improvements of the lightning protection system consisted, among other provisions, on the
installation of stretch stainless steel ropes above the stay cables. These cables were not initially
designed to avoid wind excitation and were prone to severe vibrations under usual weather
conditions.
PRESENTATION
Lightning is a very common weather phenomenon and probability that a standing structure will be hit
by a thunderbolt is not negligible. Large vertical cable structures are particularly prone to lightning
impact because of their size, their height and metallic cables conductivity. On the 27th
of January
2005, the Rion-Antirion Bridge, one of the longest multi-span cable stay bridges, has been impacted
by a lightning strike which created a fire on one of the upper stay cables, leading finally to the
collapse of this stay cable.
The best protection of large structures against lightning consists in conductive cable net surrounding
the protected area, the aim of which is to offer a preferential way for electrostatic charges to translate
from earth to clouds. This kind of Faraday cage is commonly used in rockets launch pad.
After a series of laboratory tests at full scale that clarified the reasons of the fire one of the strategies
used for the enhancement of the lightning protection system for the Rion-Antirion Bridge consisted in
installing stretch wires above the stay cables in order to intercept most of the lightning flashes [1].
Figure 1 : principle of the stretch cables protecting Rion-Antirion bridge stays from lightning
Several reasons existed to justify separation of the lightning protection cables from the suspension
stays, among which the will to keep the upper stay shape unchanged for aerodynamic purpose.
The choice of stainless steel ropes for the protection cable lead to an assembly of three ropes of
common diameter in order to achieve the required conductivity and to create a redundancy in case of
lightning damage of one of them. The three ropes were bound together with intermediate collars at
specific interval locations..
After these three ropes cables were installed vibrations occurred, as reported by eye witnesses. A rapid
analysis concluded at this time it might be vortex shedding excitation and the cable provider installed
Stockbridge dampers in May 2006 and air flow spoilers, consisting in an helical strake of limited
length running around the three ropes, in august 2006.
After 9 month observation by frequent close visual inspections it was concluded that:
- Stockbridge dampers were efficient in mitigating cables vibrations but they suffered fatigue
and were removed in October 2007 before parts fall down on the road.
- Air flow spoilers didn’t avoid cables vibrations and were accused to generate new torsion
excitation.
- The lightning protection cables themselves were suffering fatigue and some broken wires were
reported, where stress concentration occurred at some deviation collars.
At this stage a deeper investigation was decided before choosing another mitigation technique. Twelve
channels of the bridge monitoring system, out of 372, were used to monitor three lightning protection
cables with six 2D accelerometers in December 2007. Four months records of vibrations, wind speed
and wind direction at a rate of 100 Hz were transmitted to CSTB for analysis.
FULL SCALE DATA ANALYSIS
Rion Antirion bridge in orientated 20° from a north-south line. The wind direction influences both the
aerodynamics of the cables and the turbulence level of oncoming wind. Wind from north-east is less
turbulent than from east direction for instance, due to steep hills surrounding.
Figure 2 : bridge orientation compared to compass and hills surrounding
As usually observed in full scale measurement there are possibly many sources of cable vibration:
vortex shedding, galloping, parametric excitation may be responsible for vibrations of the same cable
Rion-Antirion Bridge
at different times or locations. The first concern here was to look for a correlation between wind
events and recorded large amplitudes of cables.
Looking at wind speed history compared to RMS value of accelerations it was obvious that wind
speed modulus was not the only parameter governing cable excitation because many strong wind
events did not correspond to large vibration amplitude and contrarily many large amplitude movement
occurred with moderate wind speed.
A first ranking of data was realized as strong, moderate, light vibration or no vibration that was
plotted against wind speed and direction. This showed a difference in the wind speed required to
produce moderate or strong vibration with wind direction, especially for easterly wind. For westerly
winds, coming from the open sea, there was no difference in amplitude whatever the wind direction.
This first analysis confirmed that vibration was linked to oncoming wind turbulence intensity.
The wind speed threshold above which moderate or strong vibrations occurred was close to 6 m/s for
westerly winds and wind directions surrounding 65°, but it was higher than 15 m/s for winds coming
from directions close to 95°, after passing upon a mountainous area. This threshold was minimum for
wind direction normal to bridge axis.
Comparison of vibration occurrences on the three monitored cables showed they didn’t happen at the
same time. Eye witnesses confirmed cables of the same length on the same pylon did not usually
vibrate together.
The dynamic analysis of recorded data showed that large amplitude vibrations occurred mainly for
1.1Hz frequency and its harmonics for the 299m long cable referenced M4NE.
Cable ropes are made of austenitic stain less steel grade ASTM AISI 316, open spiral strands with 19
wires 3.18mm organized as 1+6+12. The whole rope diameter is 16mm, it weights1.24 kg/m with a
nominal tension of 180 kN. The cable, composed of three ropes, 299m long, should have a first mode
frequency of 0.37Hz. The third mode of the cable was this way mainly excited in this example. At the
same time frequencies measured on the deck in the vertical direction were 0.255Hz and 0.412Hz,
corresponding to the two first vertical modes of it and on the pylon 1.58 Hz.
Figure 3 : PSD of cable M4NE (left) and bridge deck (right) vertical acceleration during a large amplitude event.
From these observations it was deduced the large amplitude vibration was not a parametric excitation
kind, but its dependency to wind proved it could be a purely aerodynamic phenomenon. Therefore
wind tunnel experiments were undertaken in order to verify these assessments and look for efficient
countermeasures.
WIND TUNNEL STATIC TESTS
A piece of rope was provided in order to build a wind tunnel sectional model. Three ropes were first
joined together in the shape of the actual cable referred as the “compact arrangement” (figure 4), this
way the wind tunnel model was representing the whole shape and the strands. Sectional model was
1.5m long.
Figure 4 : shape of the actual cable referred as “compact arrangement”
Figure 5 : model on supporting frame in wind tunnel
Model was build with high concern for its shape on a flat reference surface. The three ropes were
glued together in order to provide stiffness and avoid twisting or bending deformation. Both ends
were bound to two supporting three components balances hidden in a rigid frame situated in the
middle of a 6m wide x 5m high wind tunnel. The rigid frame maintained 2 dimensional wind
conditions without development of a boundary layer on edge panels.
The model was set horizontal. The force coordinates was chosen in order to exhibit symmetry, actual
wind normal to bridge axis corresponding to -60° or +90° incidence. Drag and lift coefficients in the
wind coordinates Cdrag and Clift were measured for wind speed 5, 10 and 15 m/s and incidence
ranging from -90° to +90°. As shown Figure 7 they were not symmetrical on both sides of 0°
incidence, what may be explained by stranding of wires.
Figure 6 : force coefficients coordinates for compacted arrangement study
Wind incidence
i>0
Forces on
the model
Fx
Fy
Fdrag
Flift
compacted arrangement, Cdrag coefficient
0.0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
4.0
-100 -80 -60 -40 -20 0 20 40 60 80 100
incidence (°)
Cd
u=5m/s
u=10m/s
u=15m/s
compacted arrangement, Clift coefficient
-2.0
-1.5
-1.0
-0.5
0.0
0.5
1.0
1.5
2.0
-100 -80 -60 -40 -20 0 20 40 60 80 100
incidence (°)
Cl
u=5m/s
u=10m/s
u=15m/s
Figure 7 : Compacted arrangement, Cdrag coefficient (left) and Clift coefficient (right) for wind incidence varying from -
90° to +90°
The slope of the lift coefficient in cable coordinates Cy (figure 8) reached twice a negative value of -1
in the wind incidence range, close to -60° and +90° that broadly corresponds on the actual bridge to
wind perpendicular to bridge axis.
The Scruton number for this cable , 2
2
D
dm
Sc
×
××
=
ρ
, calculated from damping decrement
d=0.001measured on site, cable mass m=1.24x3 kg/m, air density ρ=1.2 kg/m3 and cable apparent
diameter D=0.016x2 m, reached the value of 6, indicating a real capability of galloping for this ropes
arrangement.
Compacted arrangement, slope of the lift coefficient, dCy/di
-1
0
1
2
3
4
5
6
7
8
9
-100 -50 0 50 100
incidence (°)
u=5m/s
u=10m/s
u=15m/s
Figure 8 :Compacted arrangement, Cy coefficient slope variation with wind incidence
Another rope arrangement was suggested and its stability measured in wind tunnel.
Figure 9 : force coordinates for spaced out arrangement of ropes proposed
Wind incidence
i>0
225mm
This arrangement was called “spaced out” because the three ropes were maintained separated by
225mm by a thin metal spacer.
The same measurements as for the compact arrangement were realized in wind tunnel showing (figure
10 ) that force coefficients Cdrag and Clift were very uniform regarding wind incidence. With this
arrangement Cy slope never became negative as shown figure 11. As a first conclusion, changing the
arrangement of ropes could be an elegant solution avoiding lightning protection upper cable galloping.
At the same time, cable supplier’s preferred solution was to install viscous dampers at the lower end
of LPUC, what means no major work on the bridge, but aesthetically not the preferred solution by the
owner. Dynamic modeling in wind tunnel was achieved in order to evaluate this dissipative solution.
spaced out arrangement, Cdrag coefficient
0.0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
4.0
4.5
5.0
-100 -80 -60 -40 -20 0 20 40 60 80 100
incidence (°)
Cd
u=5m/s
u=10m/s
u=15m/s
spaced out arrangement, Clift coefficient
-2.0
-1.5
-1.0
-0.5
0.0
0.5
1.0
1.5
2.0
-100 -80 -60 -40 -20 0 20 40 60 80 100
incidence (°)
Cl
u=5m/s
u=10m/s
u=15m/s
Figure 10 : Spaced out arrangement, Cdrag coefficient (left) and Clift coefficient (right) for wind incidence varying from -
90° to +90°
spaced out arrangement, slope of the lift coefficient, dCy/di
-1
0
1
2
3
4
5
6
7
8
9
-100 -50 0 50 100
incidence (°)
u=5m/s
u=10m/s
u=15m/s
Figure 11 :Spaced out arrangement, Cy coefficient slope variation with wind incidence
WIND TUNNEL DYNAMIC TESTING
Both sectional models designed for force measurement were used for dynamic testing. Because
models had been realized with actual pieces of ropes and included end plates and supporting devices,
final model mass was 50% higher than actual cable.
It was suspended horizontally to springs arranged in a way vertical oscillation only can occurred at
frequency 1.1Hz with a damping decrement d=0.004. Model and supporting rig were installed inside
the 4m x 2m section of a low turbulence wind tunnel.
This time models were oriented in a way 0° wind incidence in wind tunnel corresponds to wind
normal to bridge axis on site.
For the compact arrangement cable strong vibrations were observed at incidence 0° and 1° and at 54°
to 56° for wind speed as low as 4m/s.
Figure 12 : Coordinates for dynamic testing of compact arrangement of ropes
Compacted cable
0
2
4
6
8
10
12
14
16
18
20
0 5 10 15 20
Wind speed (m/s)
RMSvalueofvertical
displacement(mm)
incid00°
incid01°
incid02°
incid03°
incid04°
incid05°
incid06°
incid07°
incid08°
incid09°
incid10°
Compacted cable
0
2
4
6
8
10
12
14
16
18
20
0 5 10 15
Wind speed (m/s)
RMSvalueofvertical
displacement(mm)
incid15°
incid20°
incid25°
incid30°
incid35°
incid40°
incid45°
incid50°
incid53°
incid54°
incid55°
incid56°
incid57°
incid58°
incid59°
Figure 13 : Aeroelastic response of compact arrangement cable with wind speed, amplitude in mm.
Figure 14 : increasing amplitude of compact arrangement cable for wind speed 5m/s at incidence 54° (left) and 1°(right).
Compacted cable : various damping level
0
2
4
6
8
10
12
14
0 5 10 15 20 25
Wind speed (m/s)
RMSvalueofvertical
displacement(mm)
0.22%
0.30%
0.80%
1%
1.30%
1.60%
2.20%
2.80%
Figure 15 : Effect of increasing structural damping on galloping amplitude of compact arrangement cable.
Compact
arrangementi=0°
i=60°
For the incidence considered worse, 54°, mechanical damping was increased step by step in order to
look for the minimum damping able to mitigate galloping. Fig15 shows galloping was not suppressed
with damping level less than 1.3% of critical, that is decrement d=0.08.
Same kinds of tests were conducted for the spaced out arrangement cable without any vibration
observed, whatever the wind speed and incidence. This gave another argument to guarantee this rope
arrangement will suppress galloping excitation.
Various models of spacers had been suggested, some of them including a damping effect. For one
model, consisting in a short PU cylinder, wind tunnel tests were realized in order to check the stability
of the spaced out arrangement modified by this damper. No instability was observed in a wide range
of wind speed up to 26m/s, for wind perpendicular to cable axis.
Figure 16 : Wind tunnel test of spaced out cable stability when equipped with a PU ring acting as a damping spacer.
CONCLUSION
Vibration phenomenon of Lightning Protection Upper Cables on the Rion-Antirion bridge was
identified as galloping, due to the arrangement of the three constitutive ropes.
Another arrangement of ropes was proposed and wind tunnel studies showed its efficiency in
suppressing the galloping phenomenon..
An alternative mitigation solution was damping increase by mean of viscous dampers. Wind tunnel
tests showed this solution would be efficient only if a high level of damping could be provided.
Finally it was decided to change ropes arrangement with spacers providing additional damping.
REFERENCE
[1] A. Rousseau, L. Boutillon, A. Huynh, 2006, “Lightning protection of a cable-stayed bridge”, 28th
International Conference on Lightning Protection, Kanazawa, Japan, 18-22 september 2006.

More Related Content

What's hot

Overvoltage phenomenon
Overvoltage phenomenonOvervoltage phenomenon
Overvoltage phenomenonSwaminathan P
 
A circuit for measurement of high voltage corona
A circuit for measurement of high voltage coronaA circuit for measurement of high voltage corona
A circuit for measurement of high voltage coronaaswanthmrajeev112
 
Lightning Protection
Lightning ProtectionLightning Protection
Lightning Protectionsuresh5
 
Deicing of transmisson line by dielectrc losses
Deicing of transmisson line by dielectrc lossesDeicing of transmisson line by dielectrc losses
Deicing of transmisson line by dielectrc lossesbindasbhabani
 
Deployable Helical Antenna for Nano-Satellites
Deployable Helical Antenna for Nano-SatellitesDeployable Helical Antenna for Nano-Satellites
Deployable Helical Antenna for Nano-SatellitesDaniel Ochoa
 
PROTECTION AGAINST OVER VOLTAGE AND GROUNDING Part 1
PROTECTION AGAINST OVER VOLTAGE AND GROUNDING Part 1PROTECTION AGAINST OVER VOLTAGE AND GROUNDING Part 1
PROTECTION AGAINST OVER VOLTAGE AND GROUNDING Part 1Dr. Rohit Babu
 
EC6602-Antenna fundamentals new
EC6602-Antenna fundamentals new EC6602-Antenna fundamentals new
EC6602-Antenna fundamentals new krishnamrm
 

What's hot (13)

Overvoltage phenomenon
Overvoltage phenomenonOvervoltage phenomenon
Overvoltage phenomenon
 
A circuit for measurement of high voltage corona
A circuit for measurement of high voltage coronaA circuit for measurement of high voltage corona
A circuit for measurement of high voltage corona
 
Lightning Protection
Lightning ProtectionLightning Protection
Lightning Protection
 
Lightning Protection
Lightning ProtectionLightning Protection
Lightning Protection
 
Transmission Line
Transmission LineTransmission Line
Transmission Line
 
Deicing of transmisson line by dielectrc losses
Deicing of transmisson line by dielectrc lossesDeicing of transmisson line by dielectrc losses
Deicing of transmisson line by dielectrc losses
 
study of lightning arrester
study of lightning arresterstudy of lightning arrester
study of lightning arrester
 
Microwaves
MicrowavesMicrowaves
Microwaves
 
Deployable Helical Antenna for Nano-Satellites
Deployable Helical Antenna for Nano-SatellitesDeployable Helical Antenna for Nano-Satellites
Deployable Helical Antenna for Nano-Satellites
 
Insulator String
Insulator StringInsulator String
Insulator String
 
PROTECTION AGAINST OVER VOLTAGE AND GROUNDING Part 1
PROTECTION AGAINST OVER VOLTAGE AND GROUNDING Part 1PROTECTION AGAINST OVER VOLTAGE AND GROUNDING Part 1
PROTECTION AGAINST OVER VOLTAGE AND GROUNDING Part 1
 
Corona1
Corona1Corona1
Corona1
 
EC6602-Antenna fundamentals new
EC6602-Antenna fundamentals new EC6602-Antenna fundamentals new
EC6602-Antenna fundamentals new
 

Viewers also liked

Tips to build your business
Tips to build your businessTips to build your business
Tips to build your businessMelonie Boone
 
Workshop Arrival Reflection--Thought Provoking Quotes About Strong Sustainabi...
Workshop Arrival Reflection--Thought Provoking Quotes About Strong Sustainabi...Workshop Arrival Reflection--Thought Provoking Quotes About Strong Sustainabi...
Workshop Arrival Reflection--Thought Provoking Quotes About Strong Sustainabi...Antony Upward
 
FourBeat #mft2012
FourBeat #mft2012FourBeat #mft2012
FourBeat #mft2012itog
 
Unimed leste fluminense_pf
Unimed leste fluminense_pfUnimed leste fluminense_pf
Unimed leste fluminense_pfeasysaude
 
Seismic Design for the Foundation of the Rion Antirion Bridge
Seismic Design for the Foundation of the Rion Antirion BridgeSeismic Design for the Foundation of the Rion Antirion Bridge
Seismic Design for the Foundation of the Rion Antirion Bridgegefyra-rion
 
Proyecto honda barcelona 2013 by think tank
Proyecto honda barcelona 2013 by think tankProyecto honda barcelona 2013 by think tank
Proyecto honda barcelona 2013 by think tank2013 Think Tank
 
3º eso tema 8 la salud y la enfermedad_ (1)
3º eso  tema 8  la salud y la enfermedad_ (1)3º eso  tema 8  la salud y la enfermedad_ (1)
3º eso tema 8 la salud y la enfermedad_ (1)Carma Guay Perez
 
Diga hello world ao mundo mobile
Diga hello world ao mundo mobileDiga hello world ao mundo mobile
Diga hello world ao mundo mobileCarlos Cavalcanti
 

Viewers also liked (13)

Tips to build your business
Tips to build your businessTips to build your business
Tips to build your business
 
La llamada conquista
La llamada conquistaLa llamada conquista
La llamada conquista
 
Workshop Arrival Reflection--Thought Provoking Quotes About Strong Sustainabi...
Workshop Arrival Reflection--Thought Provoking Quotes About Strong Sustainabi...Workshop Arrival Reflection--Thought Provoking Quotes About Strong Sustainabi...
Workshop Arrival Reflection--Thought Provoking Quotes About Strong Sustainabi...
 
Ix 29
Ix 29Ix 29
Ix 29
 
FourBeat #mft2012
FourBeat #mft2012FourBeat #mft2012
FourBeat #mft2012
 
Las emociones (1)
Las emociones (1)Las emociones (1)
Las emociones (1)
 
Unimed leste fluminense_pf
Unimed leste fluminense_pfUnimed leste fluminense_pf
Unimed leste fluminense_pf
 
Seismic Design for the Foundation of the Rion Antirion Bridge
Seismic Design for the Foundation of the Rion Antirion BridgeSeismic Design for the Foundation of the Rion Antirion Bridge
Seismic Design for the Foundation of the Rion Antirion Bridge
 
Proyecto honda barcelona 2013 by think tank
Proyecto honda barcelona 2013 by think tankProyecto honda barcelona 2013 by think tank
Proyecto honda barcelona 2013 by think tank
 
3º eso tema 8 la salud y la enfermedad_ (1)
3º eso  tema 8  la salud y la enfermedad_ (1)3º eso  tema 8  la salud y la enfermedad_ (1)
3º eso tema 8 la salud y la enfermedad_ (1)
 
Монгол дээл
Монгол дээлМонгол дээл
Монгол дээл
 
Little red riding hood p5
Little red riding hood p5Little red riding hood p5
Little red riding hood p5
 
Diga hello world ao mundo mobile
Diga hello world ao mundo mobileDiga hello world ao mundo mobile
Diga hello world ao mundo mobile
 

Similar to Iscd2009 flamand ppa_final

ACSR Overhead Transmission lines Modeling Considering Sag-Tension Estimation ...
ACSR Overhead Transmission lines Modeling Considering Sag-Tension Estimation ...ACSR Overhead Transmission lines Modeling Considering Sag-Tension Estimation ...
ACSR Overhead Transmission lines Modeling Considering Sag-Tension Estimation ...IJCSIS Research Publications
 
Cable Ladder Bonding with Earth Wire, Is it Necessary?
Cable Ladder Bonding with Earth Wire, Is it Necessary?Cable Ladder Bonding with Earth Wire, Is it Necessary?
Cable Ladder Bonding with Earth Wire, Is it Necessary?Mike Hamilton
 
UNIT - 06 TRANSMISSION LINES AND SUBSTATIONS
UNIT - 06 TRANSMISSION LINES AND SUBSTATIONSUNIT - 06 TRANSMISSION LINES AND SUBSTATIONS
UNIT - 06 TRANSMISSION LINES AND SUBSTATIONSPremanandDesai
 
System design-engineering-j jicable11-0279_final-evolution-in-method-performa...
System design-engineering-j jicable11-0279_final-evolution-in-method-performa...System design-engineering-j jicable11-0279_final-evolution-in-method-performa...
System design-engineering-j jicable11-0279_final-evolution-in-method-performa...nak maneth
 
A Review Paper on Converting Wind Energy to Electrical Energy using Wind-Belt...
A Review Paper on Converting Wind Energy to Electrical Energy using Wind-Belt...A Review Paper on Converting Wind Energy to Electrical Energy using Wind-Belt...
A Review Paper on Converting Wind Energy to Electrical Energy using Wind-Belt...IRJET Journal
 
Case study sterlite deadend grip
Case study  sterlite deadend gripCase study  sterlite deadend grip
Case study sterlite deadend gripHarish Agarwal
 
ESA Module 1 Part-B ME832. by Dr. Mohammed Imran
ESA Module 1 Part-B ME832. by Dr. Mohammed ImranESA Module 1 Part-B ME832. by Dr. Mohammed Imran
ESA Module 1 Part-B ME832. by Dr. Mohammed ImranMohammed Imran
 
Presentation cdynamics_sciencemeetsindustry2019
Presentation cdynamics_sciencemeetsindustry2019Presentation cdynamics_sciencemeetsindustry2019
Presentation cdynamics_sciencemeetsindustry2019Glenn Tørå
 
Montrιal o.flamand
Montrιal o.flamandMontrιal o.flamand
Montrιal o.flamandgefyra-rion
 
Experimental stress analysis BE notes by mohammed imran
Experimental stress analysis BE notes by mohammed imranExperimental stress analysis BE notes by mohammed imran
Experimental stress analysis BE notes by mohammed imranMohammed Imran
 
Behaviour Analysis of Corroded Wires Based on Statistical Models
Behaviour Analysis of Corroded Wires Based on Statistical ModelsBehaviour Analysis of Corroded Wires Based on Statistical Models
Behaviour Analysis of Corroded Wires Based on Statistical ModelsIJERDJOURNAL
 
IRJET-Sensitivity Analysis of Maximum Overvoltage on Cables with Considering ...
IRJET-Sensitivity Analysis of Maximum Overvoltage on Cables with Considering ...IRJET-Sensitivity Analysis of Maximum Overvoltage on Cables with Considering ...
IRJET-Sensitivity Analysis of Maximum Overvoltage on Cables with Considering ...IRJET Journal
 
Electrical Design of Overhead Lines.ppt
Electrical Design of Overhead Lines.pptElectrical Design of Overhead Lines.ppt
Electrical Design of Overhead Lines.pptAkdDeshmukh
 
Analysis-And-Design-Of-220kv-Transmission-Line-Tower-In-Different-Zones-I-&-V...
Analysis-And-Design-Of-220kv-Transmission-Line-Tower-In-Different-Zones-I-&-V...Analysis-And-Design-Of-220kv-Transmission-Line-Tower-In-Different-Zones-I-&-V...
Analysis-And-Design-Of-220kv-Transmission-Line-Tower-In-Different-Zones-I-&-V...Deepak Saxena
 
IDENTIFICATION OF TOWER AND BOOM-WAKES USING COLLOCATED ANEMOMETERS AND LIDAR...
IDENTIFICATION OF TOWER AND BOOM-WAKES USING COLLOCATED ANEMOMETERS AND LIDAR...IDENTIFICATION OF TOWER AND BOOM-WAKES USING COLLOCATED ANEMOMETERS AND LIDAR...
IDENTIFICATION OF TOWER AND BOOM-WAKES USING COLLOCATED ANEMOMETERS AND LIDAR...IAEME Publication
 
Rion antirion - yerevan - oct 2003
Rion antirion - yerevan  - oct 2003Rion antirion - yerevan  - oct 2003
Rion antirion - yerevan - oct 2003gefyra-rion
 
Cable vibration dampers
Cable vibration dampers  Cable vibration dampers
Cable vibration dampers chandra shekar
 
Energy’s Method for Experimental Life Prediction of a 1 + 6 Strand
Energy’s Method for Experimental Life Prediction of a 1 + 6 StrandEnergy’s Method for Experimental Life Prediction of a 1 + 6 Strand
Energy’s Method for Experimental Life Prediction of a 1 + 6 Strandtheijes
 
Wind Induced Vibrations on Cable Stayed Bridges
Wind Induced Vibrations on Cable Stayed BridgesWind Induced Vibrations on Cable Stayed Bridges
Wind Induced Vibrations on Cable Stayed BridgesIRJET Journal
 

Similar to Iscd2009 flamand ppa_final (20)

ACSR Overhead Transmission lines Modeling Considering Sag-Tension Estimation ...
ACSR Overhead Transmission lines Modeling Considering Sag-Tension Estimation ...ACSR Overhead Transmission lines Modeling Considering Sag-Tension Estimation ...
ACSR Overhead Transmission lines Modeling Considering Sag-Tension Estimation ...
 
Cable Ladder Bonding with Earth Wire, Is it Necessary?
Cable Ladder Bonding with Earth Wire, Is it Necessary?Cable Ladder Bonding with Earth Wire, Is it Necessary?
Cable Ladder Bonding with Earth Wire, Is it Necessary?
 
UNIT - 06 TRANSMISSION LINES AND SUBSTATIONS
UNIT - 06 TRANSMISSION LINES AND SUBSTATIONSUNIT - 06 TRANSMISSION LINES AND SUBSTATIONS
UNIT - 06 TRANSMISSION LINES AND SUBSTATIONS
 
System design-engineering-j jicable11-0279_final-evolution-in-method-performa...
System design-engineering-j jicable11-0279_final-evolution-in-method-performa...System design-engineering-j jicable11-0279_final-evolution-in-method-performa...
System design-engineering-j jicable11-0279_final-evolution-in-method-performa...
 
A Review Paper on Converting Wind Energy to Electrical Energy using Wind-Belt...
A Review Paper on Converting Wind Energy to Electrical Energy using Wind-Belt...A Review Paper on Converting Wind Energy to Electrical Energy using Wind-Belt...
A Review Paper on Converting Wind Energy to Electrical Energy using Wind-Belt...
 
Case study sterlite deadend grip
Case study  sterlite deadend gripCase study  sterlite deadend grip
Case study sterlite deadend grip
 
ESA Module 1 Part-B ME832. by Dr. Mohammed Imran
ESA Module 1 Part-B ME832. by Dr. Mohammed ImranESA Module 1 Part-B ME832. by Dr. Mohammed Imran
ESA Module 1 Part-B ME832. by Dr. Mohammed Imran
 
Presentation cdynamics_sciencemeetsindustry2019
Presentation cdynamics_sciencemeetsindustry2019Presentation cdynamics_sciencemeetsindustry2019
Presentation cdynamics_sciencemeetsindustry2019
 
Montrιal o.flamand
Montrιal o.flamandMontrιal o.flamand
Montrιal o.flamand
 
Experimental stress analysis BE notes by mohammed imran
Experimental stress analysis BE notes by mohammed imranExperimental stress analysis BE notes by mohammed imran
Experimental stress analysis BE notes by mohammed imran
 
Behaviour Analysis of Corroded Wires Based on Statistical Models
Behaviour Analysis of Corroded Wires Based on Statistical ModelsBehaviour Analysis of Corroded Wires Based on Statistical Models
Behaviour Analysis of Corroded Wires Based on Statistical Models
 
IRJET-Sensitivity Analysis of Maximum Overvoltage on Cables with Considering ...
IRJET-Sensitivity Analysis of Maximum Overvoltage on Cables with Considering ...IRJET-Sensitivity Analysis of Maximum Overvoltage on Cables with Considering ...
IRJET-Sensitivity Analysis of Maximum Overvoltage on Cables with Considering ...
 
Electrical Design of Overhead Lines.ppt
Electrical Design of Overhead Lines.pptElectrical Design of Overhead Lines.ppt
Electrical Design of Overhead Lines.ppt
 
Analysis-And-Design-Of-220kv-Transmission-Line-Tower-In-Different-Zones-I-&-V...
Analysis-And-Design-Of-220kv-Transmission-Line-Tower-In-Different-Zones-I-&-V...Analysis-And-Design-Of-220kv-Transmission-Line-Tower-In-Different-Zones-I-&-V...
Analysis-And-Design-Of-220kv-Transmission-Line-Tower-In-Different-Zones-I-&-V...
 
IDENTIFICATION OF TOWER AND BOOM-WAKES USING COLLOCATED ANEMOMETERS AND LIDAR...
IDENTIFICATION OF TOWER AND BOOM-WAKES USING COLLOCATED ANEMOMETERS AND LIDAR...IDENTIFICATION OF TOWER AND BOOM-WAKES USING COLLOCATED ANEMOMETERS AND LIDAR...
IDENTIFICATION OF TOWER AND BOOM-WAKES USING COLLOCATED ANEMOMETERS AND LIDAR...
 
Rion antirion - yerevan - oct 2003
Rion antirion - yerevan  - oct 2003Rion antirion - yerevan  - oct 2003
Rion antirion - yerevan - oct 2003
 
Cable vibration dampers
Cable vibration dampers  Cable vibration dampers
Cable vibration dampers
 
Energy’s Method for Experimental Life Prediction of a 1 + 6 Strand
Energy’s Method for Experimental Life Prediction of a 1 + 6 StrandEnergy’s Method for Experimental Life Prediction of a 1 + 6 Strand
Energy’s Method for Experimental Life Prediction of a 1 + 6 Strand
 
Wind Induced Vibrations on Cable Stayed Bridges
Wind Induced Vibrations on Cable Stayed BridgesWind Induced Vibrations on Cable Stayed Bridges
Wind Induced Vibrations on Cable Stayed Bridges
 
Sheath bonding method for underground cables
Sheath bonding method for underground cablesSheath bonding method for underground cables
Sheath bonding method for underground cables
 

More from gefyra-rion

ΓΕΦΥΡΑ Α.Ε. – Ισολογισμός 31.12.2012
ΓΕΦΥΡΑ Α.Ε. – Ισολογισμός 31.12.2012ΓΕΦΥΡΑ Α.Ε. – Ισολογισμός 31.12.2012
ΓΕΦΥΡΑ Α.Ε. – Ισολογισμός 31.12.2012gefyra-rion
 
ΓΕΦΥΡΑ Α.Ε. – Πρόσκληση σε τακτική γενική συνέλευση των μετόχων
ΓΕΦΥΡΑ Α.Ε. – Πρόσκληση σε τακτική γενική συνέλευση των μετόχωνΓΕΦΥΡΑ Α.Ε. – Πρόσκληση σε τακτική γενική συνέλευση των μετόχων
ΓΕΦΥΡΑ Α.Ε. – Πρόσκληση σε τακτική γενική συνέλευση των μετόχωνgefyra-rion
 
Universite de tous les savoirs
Universite de tous les savoirsUniversite de tous les savoirs
Universite de tous les savoirsgefyra-rion
 
The stay cable system papanikolas liolios
The stay cable system papanikolas lioliosThe stay cable system papanikolas liolios
The stay cable system papanikolas lioliosgefyra-rion
 
Patras 4th congress on steel structures
Patras 4th congress on steel structuresPatras 4th congress on steel structures
Patras 4th congress on steel structuresgefyra-rion
 
Mokpo symposium pecker 2006
Mokpo symposium pecker 2006Mokpo symposium pecker 2006
Mokpo symposium pecker 2006gefyra-rion
 
Hsgf bolts papanikolas
Hsgf bolts papanikolasHsgf bolts papanikolas
Hsgf bolts papanikolasgefyra-rion
 
Geo trans2004 pecker
Geo trans2004 peckerGeo trans2004 pecker
Geo trans2004 peckergefyra-rion
 
Fib2010 article269 june 2008 eq case study_rev_a
Fib2010 article269 june 2008 eq case study_rev_aFib2010 article269 june 2008 eq case study_rev_a
Fib2010 article269 june 2008 eq case study_rev_agefyra-rion
 
Fib2010 article263 concrete durability_rev_a
Fib2010 article263 concrete durability_rev_aFib2010 article263 concrete durability_rev_a
Fib2010 article263 concrete durability_rev_agefyra-rion
 
Fib2010 article260 design & construction_rev_a
Fib2010 article260 design & construction_rev_aFib2010 article260 design & construction_rev_a
Fib2010 article260 design & construction_rev_agefyra-rion
 

More from gefyra-rion (20)

ΓΕΦΥΡΑ Α.Ε. – Ισολογισμός 31.12.2012
ΓΕΦΥΡΑ Α.Ε. – Ισολογισμός 31.12.2012ΓΕΦΥΡΑ Α.Ε. – Ισολογισμός 31.12.2012
ΓΕΦΥΡΑ Α.Ε. – Ισολογισμός 31.12.2012
 
ΓΕΦΥΡΑ Α.Ε. – Πρόσκληση σε τακτική γενική συνέλευση των μετόχων
ΓΕΦΥΡΑ Α.Ε. – Πρόσκληση σε τακτική γενική συνέλευση των μετόχωνΓΕΦΥΡΑ Α.Ε. – Πρόσκληση σε τακτική γενική συνέλευση των μετόχων
ΓΕΦΥΡΑ Α.Ε. – Πρόσκληση σε τακτική γενική συνέλευση των μετόχων
 
Universite de tous les savoirs
Universite de tous les savoirsUniversite de tous les savoirs
Universite de tous les savoirs
 
Travaux no 809
Travaux no 809Travaux no 809
Travaux no 809
 
The stay cable system papanikolas liolios
The stay cable system papanikolas lioliosThe stay cable system papanikolas liolios
The stay cable system papanikolas liolios
 
Pecker aci2003
Pecker aci2003Pecker aci2003
Pecker aci2003
 
Pecker salencon
Pecker salenconPecker salencon
Pecker salencon
 
Patras 4th congress on steel structures
Patras 4th congress on steel structuresPatras 4th congress on steel structures
Patras 4th congress on steel structures
 
Mokpo symposium pecker 2006
Mokpo symposium pecker 2006Mokpo symposium pecker 2006
Mokpo symposium pecker 2006
 
Londe ap
Londe apLonde ap
Londe ap
 
Lisbonne
LisbonneLisbonne
Lisbonne
 
La recherche
La rechercheLa recherche
La recherche
 
Hsgf bolts papanikolas
Hsgf bolts papanikolasHsgf bolts papanikolas
Hsgf bolts papanikolas
 
Habib
HabibHabib
Habib
 
Geo trans2004 pecker
Geo trans2004 peckerGeo trans2004 pecker
Geo trans2004 pecker
 
Fip rion2
Fip rion2Fip rion2
Fip rion2
 
Fib2010 article269 june 2008 eq case study_rev_a
Fib2010 article269 june 2008 eq case study_rev_aFib2010 article269 june 2008 eq case study_rev_a
Fib2010 article269 june 2008 eq case study_rev_a
 
Fib2010 article263 concrete durability_rev_a
Fib2010 article263 concrete durability_rev_aFib2010 article263 concrete durability_rev_a
Fib2010 article263 concrete durability_rev_a
 
Fib2010 article260 design & construction_rev_a
Fib2010 article260 design & construction_rev_aFib2010 article260 design & construction_rev_a
Fib2010 article260 design & construction_rev_a
 
Enr jan2001
Enr jan2001Enr jan2001
Enr jan2001
 

Recently uploaded

DevoxxFR 2024 Reproducible Builds with Apache Maven
DevoxxFR 2024 Reproducible Builds with Apache MavenDevoxxFR 2024 Reproducible Builds with Apache Maven
DevoxxFR 2024 Reproducible Builds with Apache MavenHervé Boutemy
 
Advanced Computer Architecture – An Introduction
Advanced Computer Architecture – An IntroductionAdvanced Computer Architecture – An Introduction
Advanced Computer Architecture – An IntroductionDilum Bandara
 
The Role of FIDO in a Cyber Secure Netherlands: FIDO Paris Seminar.pptx
The Role of FIDO in a Cyber Secure Netherlands: FIDO Paris Seminar.pptxThe Role of FIDO in a Cyber Secure Netherlands: FIDO Paris Seminar.pptx
The Role of FIDO in a Cyber Secure Netherlands: FIDO Paris Seminar.pptxLoriGlavin3
 
Anypoint Exchange: It’s Not Just a Repo!
Anypoint Exchange: It’s Not Just a Repo!Anypoint Exchange: It’s Not Just a Repo!
Anypoint Exchange: It’s Not Just a Repo!Manik S Magar
 
DSPy a system for AI to Write Prompts and Do Fine Tuning
DSPy a system for AI to Write Prompts and Do Fine TuningDSPy a system for AI to Write Prompts and Do Fine Tuning
DSPy a system for AI to Write Prompts and Do Fine TuningLars Bell
 
The State of Passkeys with FIDO Alliance.pptx
The State of Passkeys with FIDO Alliance.pptxThe State of Passkeys with FIDO Alliance.pptx
The State of Passkeys with FIDO Alliance.pptxLoriGlavin3
 
SALESFORCE EDUCATION CLOUD | FEXLE SERVICES
SALESFORCE EDUCATION CLOUD | FEXLE SERVICESSALESFORCE EDUCATION CLOUD | FEXLE SERVICES
SALESFORCE EDUCATION CLOUD | FEXLE SERVICESmohitsingh558521
 
How to write a Business Continuity Plan
How to write a Business Continuity PlanHow to write a Business Continuity Plan
How to write a Business Continuity PlanDatabarracks
 
The Fit for Passkeys for Employee and Consumer Sign-ins: FIDO Paris Seminar.pptx
The Fit for Passkeys for Employee and Consumer Sign-ins: FIDO Paris Seminar.pptxThe Fit for Passkeys for Employee and Consumer Sign-ins: FIDO Paris Seminar.pptx
The Fit for Passkeys for Employee and Consumer Sign-ins: FIDO Paris Seminar.pptxLoriGlavin3
 
Artificial intelligence in cctv survelliance.pptx
Artificial intelligence in cctv survelliance.pptxArtificial intelligence in cctv survelliance.pptx
Artificial intelligence in cctv survelliance.pptxhariprasad279825
 
Training state-of-the-art general text embedding
Training state-of-the-art general text embeddingTraining state-of-the-art general text embedding
Training state-of-the-art general text embeddingZilliz
 
Unraveling Multimodality with Large Language Models.pdf
Unraveling Multimodality with Large Language Models.pdfUnraveling Multimodality with Large Language Models.pdf
Unraveling Multimodality with Large Language Models.pdfAlex Barbosa Coqueiro
 
A Journey Into the Emotions of Software Developers
A Journey Into the Emotions of Software DevelopersA Journey Into the Emotions of Software Developers
A Journey Into the Emotions of Software DevelopersNicole Novielli
 
Transcript: New from BookNet Canada for 2024: BNC CataList - Tech Forum 2024
Transcript: New from BookNet Canada for 2024: BNC CataList - Tech Forum 2024Transcript: New from BookNet Canada for 2024: BNC CataList - Tech Forum 2024
Transcript: New from BookNet Canada for 2024: BNC CataList - Tech Forum 2024BookNet Canada
 
"Debugging python applications inside k8s environment", Andrii Soldatenko
"Debugging python applications inside k8s environment", Andrii Soldatenko"Debugging python applications inside k8s environment", Andrii Soldatenko
"Debugging python applications inside k8s environment", Andrii SoldatenkoFwdays
 
"ML in Production",Oleksandr Bagan
"ML in Production",Oleksandr Bagan"ML in Production",Oleksandr Bagan
"ML in Production",Oleksandr BaganFwdays
 
Merck Moving Beyond Passwords: FIDO Paris Seminar.pptx
Merck Moving Beyond Passwords: FIDO Paris Seminar.pptxMerck Moving Beyond Passwords: FIDO Paris Seminar.pptx
Merck Moving Beyond Passwords: FIDO Paris Seminar.pptxLoriGlavin3
 
A Deep Dive on Passkeys: FIDO Paris Seminar.pptx
A Deep Dive on Passkeys: FIDO Paris Seminar.pptxA Deep Dive on Passkeys: FIDO Paris Seminar.pptx
A Deep Dive on Passkeys: FIDO Paris Seminar.pptxLoriGlavin3
 
DevEX - reference for building teams, processes, and platforms
DevEX - reference for building teams, processes, and platformsDevEX - reference for building teams, processes, and platforms
DevEX - reference for building teams, processes, and platformsSergiu Bodiu
 
What is Artificial Intelligence?????????
What is Artificial Intelligence?????????What is Artificial Intelligence?????????
What is Artificial Intelligence?????????blackmambaettijean
 

Recently uploaded (20)

DevoxxFR 2024 Reproducible Builds with Apache Maven
DevoxxFR 2024 Reproducible Builds with Apache MavenDevoxxFR 2024 Reproducible Builds with Apache Maven
DevoxxFR 2024 Reproducible Builds with Apache Maven
 
Advanced Computer Architecture – An Introduction
Advanced Computer Architecture – An IntroductionAdvanced Computer Architecture – An Introduction
Advanced Computer Architecture – An Introduction
 
The Role of FIDO in a Cyber Secure Netherlands: FIDO Paris Seminar.pptx
The Role of FIDO in a Cyber Secure Netherlands: FIDO Paris Seminar.pptxThe Role of FIDO in a Cyber Secure Netherlands: FIDO Paris Seminar.pptx
The Role of FIDO in a Cyber Secure Netherlands: FIDO Paris Seminar.pptx
 
Anypoint Exchange: It’s Not Just a Repo!
Anypoint Exchange: It’s Not Just a Repo!Anypoint Exchange: It’s Not Just a Repo!
Anypoint Exchange: It’s Not Just a Repo!
 
DSPy a system for AI to Write Prompts and Do Fine Tuning
DSPy a system for AI to Write Prompts and Do Fine TuningDSPy a system for AI to Write Prompts and Do Fine Tuning
DSPy a system for AI to Write Prompts and Do Fine Tuning
 
The State of Passkeys with FIDO Alliance.pptx
The State of Passkeys with FIDO Alliance.pptxThe State of Passkeys with FIDO Alliance.pptx
The State of Passkeys with FIDO Alliance.pptx
 
SALESFORCE EDUCATION CLOUD | FEXLE SERVICES
SALESFORCE EDUCATION CLOUD | FEXLE SERVICESSALESFORCE EDUCATION CLOUD | FEXLE SERVICES
SALESFORCE EDUCATION CLOUD | FEXLE SERVICES
 
How to write a Business Continuity Plan
How to write a Business Continuity PlanHow to write a Business Continuity Plan
How to write a Business Continuity Plan
 
The Fit for Passkeys for Employee and Consumer Sign-ins: FIDO Paris Seminar.pptx
The Fit for Passkeys for Employee and Consumer Sign-ins: FIDO Paris Seminar.pptxThe Fit for Passkeys for Employee and Consumer Sign-ins: FIDO Paris Seminar.pptx
The Fit for Passkeys for Employee and Consumer Sign-ins: FIDO Paris Seminar.pptx
 
Artificial intelligence in cctv survelliance.pptx
Artificial intelligence in cctv survelliance.pptxArtificial intelligence in cctv survelliance.pptx
Artificial intelligence in cctv survelliance.pptx
 
Training state-of-the-art general text embedding
Training state-of-the-art general text embeddingTraining state-of-the-art general text embedding
Training state-of-the-art general text embedding
 
Unraveling Multimodality with Large Language Models.pdf
Unraveling Multimodality with Large Language Models.pdfUnraveling Multimodality with Large Language Models.pdf
Unraveling Multimodality with Large Language Models.pdf
 
A Journey Into the Emotions of Software Developers
A Journey Into the Emotions of Software DevelopersA Journey Into the Emotions of Software Developers
A Journey Into the Emotions of Software Developers
 
Transcript: New from BookNet Canada for 2024: BNC CataList - Tech Forum 2024
Transcript: New from BookNet Canada for 2024: BNC CataList - Tech Forum 2024Transcript: New from BookNet Canada for 2024: BNC CataList - Tech Forum 2024
Transcript: New from BookNet Canada for 2024: BNC CataList - Tech Forum 2024
 
"Debugging python applications inside k8s environment", Andrii Soldatenko
"Debugging python applications inside k8s environment", Andrii Soldatenko"Debugging python applications inside k8s environment", Andrii Soldatenko
"Debugging python applications inside k8s environment", Andrii Soldatenko
 
"ML in Production",Oleksandr Bagan
"ML in Production",Oleksandr Bagan"ML in Production",Oleksandr Bagan
"ML in Production",Oleksandr Bagan
 
Merck Moving Beyond Passwords: FIDO Paris Seminar.pptx
Merck Moving Beyond Passwords: FIDO Paris Seminar.pptxMerck Moving Beyond Passwords: FIDO Paris Seminar.pptx
Merck Moving Beyond Passwords: FIDO Paris Seminar.pptx
 
A Deep Dive on Passkeys: FIDO Paris Seminar.pptx
A Deep Dive on Passkeys: FIDO Paris Seminar.pptxA Deep Dive on Passkeys: FIDO Paris Seminar.pptx
A Deep Dive on Passkeys: FIDO Paris Seminar.pptx
 
DevEX - reference for building teams, processes, and platforms
DevEX - reference for building teams, processes, and platformsDevEX - reference for building teams, processes, and platforms
DevEX - reference for building teams, processes, and platforms
 
What is Artificial Intelligence?????????
What is Artificial Intelligence?????????What is Artificial Intelligence?????????
What is Artificial Intelligence?????????
 

Iscd2009 flamand ppa_final

  • 1. VIBRATION OF LIGHTNING PROTECTION CABLES ON RION-ANTIRION BRIDGE Dr. Panayoti PAPANIKOLAS Vice-Chairman & Managing Director GEFYRA S.A.- 2 Rizariou Str., 152 33 Halandri, Greece Olivier FLAMAND CSTB – 11 rue H. Picherit, 44300 Nantes – France Olivier.flamand@cstb.fr Introduction The Rion-Antirion bridge is a major cable stayed structure upon the golf of Corinth in Greece. On the 27th of January 2005, the bridge has been struck by lightning, leading to the failure of one stay cable. The improvements of the lightning protection system consisted, among other provisions, on the installation of stretch stainless steel ropes above the stay cables. These cables were not initially designed to avoid wind excitation and were prone to severe vibrations under usual weather conditions. PRESENTATION Lightning is a very common weather phenomenon and probability that a standing structure will be hit by a thunderbolt is not negligible. Large vertical cable structures are particularly prone to lightning impact because of their size, their height and metallic cables conductivity. On the 27th of January 2005, the Rion-Antirion Bridge, one of the longest multi-span cable stay bridges, has been impacted by a lightning strike which created a fire on one of the upper stay cables, leading finally to the collapse of this stay cable. The best protection of large structures against lightning consists in conductive cable net surrounding the protected area, the aim of which is to offer a preferential way for electrostatic charges to translate from earth to clouds. This kind of Faraday cage is commonly used in rockets launch pad. After a series of laboratory tests at full scale that clarified the reasons of the fire one of the strategies used for the enhancement of the lightning protection system for the Rion-Antirion Bridge consisted in installing stretch wires above the stay cables in order to intercept most of the lightning flashes [1]. Figure 1 : principle of the stretch cables protecting Rion-Antirion bridge stays from lightning
  • 2. Several reasons existed to justify separation of the lightning protection cables from the suspension stays, among which the will to keep the upper stay shape unchanged for aerodynamic purpose. The choice of stainless steel ropes for the protection cable lead to an assembly of three ropes of common diameter in order to achieve the required conductivity and to create a redundancy in case of lightning damage of one of them. The three ropes were bound together with intermediate collars at specific interval locations.. After these three ropes cables were installed vibrations occurred, as reported by eye witnesses. A rapid analysis concluded at this time it might be vortex shedding excitation and the cable provider installed Stockbridge dampers in May 2006 and air flow spoilers, consisting in an helical strake of limited length running around the three ropes, in august 2006. After 9 month observation by frequent close visual inspections it was concluded that: - Stockbridge dampers were efficient in mitigating cables vibrations but they suffered fatigue and were removed in October 2007 before parts fall down on the road. - Air flow spoilers didn’t avoid cables vibrations and were accused to generate new torsion excitation. - The lightning protection cables themselves were suffering fatigue and some broken wires were reported, where stress concentration occurred at some deviation collars. At this stage a deeper investigation was decided before choosing another mitigation technique. Twelve channels of the bridge monitoring system, out of 372, were used to monitor three lightning protection cables with six 2D accelerometers in December 2007. Four months records of vibrations, wind speed and wind direction at a rate of 100 Hz were transmitted to CSTB for analysis. FULL SCALE DATA ANALYSIS Rion Antirion bridge in orientated 20° from a north-south line. The wind direction influences both the aerodynamics of the cables and the turbulence level of oncoming wind. Wind from north-east is less turbulent than from east direction for instance, due to steep hills surrounding. Figure 2 : bridge orientation compared to compass and hills surrounding As usually observed in full scale measurement there are possibly many sources of cable vibration: vortex shedding, galloping, parametric excitation may be responsible for vibrations of the same cable Rion-Antirion Bridge
  • 3. at different times or locations. The first concern here was to look for a correlation between wind events and recorded large amplitudes of cables. Looking at wind speed history compared to RMS value of accelerations it was obvious that wind speed modulus was not the only parameter governing cable excitation because many strong wind events did not correspond to large vibration amplitude and contrarily many large amplitude movement occurred with moderate wind speed. A first ranking of data was realized as strong, moderate, light vibration or no vibration that was plotted against wind speed and direction. This showed a difference in the wind speed required to produce moderate or strong vibration with wind direction, especially for easterly wind. For westerly winds, coming from the open sea, there was no difference in amplitude whatever the wind direction. This first analysis confirmed that vibration was linked to oncoming wind turbulence intensity. The wind speed threshold above which moderate or strong vibrations occurred was close to 6 m/s for westerly winds and wind directions surrounding 65°, but it was higher than 15 m/s for winds coming from directions close to 95°, after passing upon a mountainous area. This threshold was minimum for wind direction normal to bridge axis. Comparison of vibration occurrences on the three monitored cables showed they didn’t happen at the same time. Eye witnesses confirmed cables of the same length on the same pylon did not usually vibrate together. The dynamic analysis of recorded data showed that large amplitude vibrations occurred mainly for 1.1Hz frequency and its harmonics for the 299m long cable referenced M4NE. Cable ropes are made of austenitic stain less steel grade ASTM AISI 316, open spiral strands with 19 wires 3.18mm organized as 1+6+12. The whole rope diameter is 16mm, it weights1.24 kg/m with a nominal tension of 180 kN. The cable, composed of three ropes, 299m long, should have a first mode frequency of 0.37Hz. The third mode of the cable was this way mainly excited in this example. At the same time frequencies measured on the deck in the vertical direction were 0.255Hz and 0.412Hz, corresponding to the two first vertical modes of it and on the pylon 1.58 Hz. Figure 3 : PSD of cable M4NE (left) and bridge deck (right) vertical acceleration during a large amplitude event. From these observations it was deduced the large amplitude vibration was not a parametric excitation kind, but its dependency to wind proved it could be a purely aerodynamic phenomenon. Therefore wind tunnel experiments were undertaken in order to verify these assessments and look for efficient countermeasures. WIND TUNNEL STATIC TESTS A piece of rope was provided in order to build a wind tunnel sectional model. Three ropes were first joined together in the shape of the actual cable referred as the “compact arrangement” (figure 4), this way the wind tunnel model was representing the whole shape and the strands. Sectional model was 1.5m long.
  • 4. Figure 4 : shape of the actual cable referred as “compact arrangement” Figure 5 : model on supporting frame in wind tunnel Model was build with high concern for its shape on a flat reference surface. The three ropes were glued together in order to provide stiffness and avoid twisting or bending deformation. Both ends were bound to two supporting three components balances hidden in a rigid frame situated in the middle of a 6m wide x 5m high wind tunnel. The rigid frame maintained 2 dimensional wind conditions without development of a boundary layer on edge panels. The model was set horizontal. The force coordinates was chosen in order to exhibit symmetry, actual wind normal to bridge axis corresponding to -60° or +90° incidence. Drag and lift coefficients in the wind coordinates Cdrag and Clift were measured for wind speed 5, 10 and 15 m/s and incidence ranging from -90° to +90°. As shown Figure 7 they were not symmetrical on both sides of 0° incidence, what may be explained by stranding of wires. Figure 6 : force coefficients coordinates for compacted arrangement study Wind incidence i>0 Forces on the model Fx Fy Fdrag Flift
  • 5. compacted arrangement, Cdrag coefficient 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 -100 -80 -60 -40 -20 0 20 40 60 80 100 incidence (°) Cd u=5m/s u=10m/s u=15m/s compacted arrangement, Clift coefficient -2.0 -1.5 -1.0 -0.5 0.0 0.5 1.0 1.5 2.0 -100 -80 -60 -40 -20 0 20 40 60 80 100 incidence (°) Cl u=5m/s u=10m/s u=15m/s Figure 7 : Compacted arrangement, Cdrag coefficient (left) and Clift coefficient (right) for wind incidence varying from - 90° to +90° The slope of the lift coefficient in cable coordinates Cy (figure 8) reached twice a negative value of -1 in the wind incidence range, close to -60° and +90° that broadly corresponds on the actual bridge to wind perpendicular to bridge axis. The Scruton number for this cable , 2 2 D dm Sc × ×× = ρ , calculated from damping decrement d=0.001measured on site, cable mass m=1.24x3 kg/m, air density ρ=1.2 kg/m3 and cable apparent diameter D=0.016x2 m, reached the value of 6, indicating a real capability of galloping for this ropes arrangement. Compacted arrangement, slope of the lift coefficient, dCy/di -1 0 1 2 3 4 5 6 7 8 9 -100 -50 0 50 100 incidence (°) u=5m/s u=10m/s u=15m/s Figure 8 :Compacted arrangement, Cy coefficient slope variation with wind incidence Another rope arrangement was suggested and its stability measured in wind tunnel. Figure 9 : force coordinates for spaced out arrangement of ropes proposed Wind incidence i>0 225mm
  • 6. This arrangement was called “spaced out” because the three ropes were maintained separated by 225mm by a thin metal spacer. The same measurements as for the compact arrangement were realized in wind tunnel showing (figure 10 ) that force coefficients Cdrag and Clift were very uniform regarding wind incidence. With this arrangement Cy slope never became negative as shown figure 11. As a first conclusion, changing the arrangement of ropes could be an elegant solution avoiding lightning protection upper cable galloping. At the same time, cable supplier’s preferred solution was to install viscous dampers at the lower end of LPUC, what means no major work on the bridge, but aesthetically not the preferred solution by the owner. Dynamic modeling in wind tunnel was achieved in order to evaluate this dissipative solution. spaced out arrangement, Cdrag coefficient 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 -100 -80 -60 -40 -20 0 20 40 60 80 100 incidence (°) Cd u=5m/s u=10m/s u=15m/s spaced out arrangement, Clift coefficient -2.0 -1.5 -1.0 -0.5 0.0 0.5 1.0 1.5 2.0 -100 -80 -60 -40 -20 0 20 40 60 80 100 incidence (°) Cl u=5m/s u=10m/s u=15m/s Figure 10 : Spaced out arrangement, Cdrag coefficient (left) and Clift coefficient (right) for wind incidence varying from - 90° to +90° spaced out arrangement, slope of the lift coefficient, dCy/di -1 0 1 2 3 4 5 6 7 8 9 -100 -50 0 50 100 incidence (°) u=5m/s u=10m/s u=15m/s Figure 11 :Spaced out arrangement, Cy coefficient slope variation with wind incidence WIND TUNNEL DYNAMIC TESTING Both sectional models designed for force measurement were used for dynamic testing. Because models had been realized with actual pieces of ropes and included end plates and supporting devices, final model mass was 50% higher than actual cable. It was suspended horizontally to springs arranged in a way vertical oscillation only can occurred at frequency 1.1Hz with a damping decrement d=0.004. Model and supporting rig were installed inside the 4m x 2m section of a low turbulence wind tunnel. This time models were oriented in a way 0° wind incidence in wind tunnel corresponds to wind normal to bridge axis on site. For the compact arrangement cable strong vibrations were observed at incidence 0° and 1° and at 54° to 56° for wind speed as low as 4m/s.
  • 7. Figure 12 : Coordinates for dynamic testing of compact arrangement of ropes Compacted cable 0 2 4 6 8 10 12 14 16 18 20 0 5 10 15 20 Wind speed (m/s) RMSvalueofvertical displacement(mm) incid00° incid01° incid02° incid03° incid04° incid05° incid06° incid07° incid08° incid09° incid10° Compacted cable 0 2 4 6 8 10 12 14 16 18 20 0 5 10 15 Wind speed (m/s) RMSvalueofvertical displacement(mm) incid15° incid20° incid25° incid30° incid35° incid40° incid45° incid50° incid53° incid54° incid55° incid56° incid57° incid58° incid59° Figure 13 : Aeroelastic response of compact arrangement cable with wind speed, amplitude in mm. Figure 14 : increasing amplitude of compact arrangement cable for wind speed 5m/s at incidence 54° (left) and 1°(right). Compacted cable : various damping level 0 2 4 6 8 10 12 14 0 5 10 15 20 25 Wind speed (m/s) RMSvalueofvertical displacement(mm) 0.22% 0.30% 0.80% 1% 1.30% 1.60% 2.20% 2.80% Figure 15 : Effect of increasing structural damping on galloping amplitude of compact arrangement cable. Compact arrangementi=0° i=60°
  • 8. For the incidence considered worse, 54°, mechanical damping was increased step by step in order to look for the minimum damping able to mitigate galloping. Fig15 shows galloping was not suppressed with damping level less than 1.3% of critical, that is decrement d=0.08. Same kinds of tests were conducted for the spaced out arrangement cable without any vibration observed, whatever the wind speed and incidence. This gave another argument to guarantee this rope arrangement will suppress galloping excitation. Various models of spacers had been suggested, some of them including a damping effect. For one model, consisting in a short PU cylinder, wind tunnel tests were realized in order to check the stability of the spaced out arrangement modified by this damper. No instability was observed in a wide range of wind speed up to 26m/s, for wind perpendicular to cable axis. Figure 16 : Wind tunnel test of spaced out cable stability when equipped with a PU ring acting as a damping spacer. CONCLUSION Vibration phenomenon of Lightning Protection Upper Cables on the Rion-Antirion bridge was identified as galloping, due to the arrangement of the three constitutive ropes. Another arrangement of ropes was proposed and wind tunnel studies showed its efficiency in suppressing the galloping phenomenon.. An alternative mitigation solution was damping increase by mean of viscous dampers. Wind tunnel tests showed this solution would be efficient only if a high level of damping could be provided. Finally it was decided to change ropes arrangement with spacers providing additional damping. REFERENCE [1] A. Rousseau, L. Boutillon, A. Huynh, 2006, “Lightning protection of a cable-stayed bridge”, 28th International Conference on Lightning Protection, Kanazawa, Japan, 18-22 september 2006.