Enviro Technology Services plc




EnviroHire


With the largest stock of state-of-the-art environmental
monitoring equipm...
EnviroHire


                         Real-time                                                             Air Quality
  ...
Industrial Health and                                      Continuous Emissions
Safety Equipment                          ...
EnviroHire


Vehicle Emission                                        Indoor
Monitoring                                    ...
Upcoming SlideShare
Loading in …5
×

Et enviro hire leaflet

542 views
474 views

Published on

Published in: Technology
0 Comments
0 Likes
Statistics
Notes
  • Be the first to comment

  • Be the first to like this

No Downloads
Views
Total views
542
On SlideShare
0
From Embeds
0
Number of Embeds
0
Actions
Shares
0
Downloads
2
Comments
0
Likes
0
Embeds 0
No embeds

No notes for slide

Et enviro hire leaflet

  1. 1. Enviro Technology Services plc EnviroHire With the largest stock of state-of-the-art environmental monitoring equipment for hire in the UK, we can offer just about any item from individual analysers, portable air samplers and dust monitoring equipment to meteorological stations and remote sensing air pollution monitoring systems and networks. Accuscan RSD System With no capital outlay and a choice of long, medium or short-term agreements APPLICATIONS available, it can, under certain circumstances, make sound economic sense to hire rather than purchase. All instruments are certified to National Standard calibrations • Consultants and, from initial enquiry to delivery, you will have the confidence of dealing with one of the most highly qualified service teams in the world. • Private industry Whether the location is a major city centre or a remote highland hill top, our • Local Authorities installation engineers are equipped with the latest technology, including 4-wheel • Research establishments drive vehicles, to get the equipment where you want it, when you want it, set-up and running – fast! NEW – Enviro Technology can provide clients with a unique vehicle emissions monitoring survey using the Accuscan 4600 remote sensing system www.et.co.uk
  2. 2. EnviroHire Real-time Air Quality Particulate Samplers Monitoring SM200 Real-time Dust Analyser/ ET Stand-alone Analysers 40 filter Sampler Continuous gas analysers for measuring criteria The SM200 can be used for both automatic dust pollutants, VOCs and BTX. On-line diagnostics and sampling and filter sampling (up to 40 filters). data recovery with large internal storage facility. The analyser conforms to both UK and EU US-EPA, MCERTS and TÜV approved. CE marked. specifications for particulate measurement (CEN Specialist applications: SO2, NO, NO2, NOX, CO, O3, VOCs, 12341 approved). Available with inlet heads for Benzene, 1.3 Butadiene, H2S, N2O, NH3 and others. TSP, PM10 and PM2.5, the SM200 is the most flexible dust monitor available providing maximum ET Systems and Networks performance with minimal maintenance. ET digital Air Quality Systems and Networks are Specialist applications: TSP, PM10 and PM2.5. the most advanced and flexible systems available. Utilising Integrated Digital Technology (IDT), data BAM 1020 Real-time Dust Analyser retrieval is redefined and the standard for air Advanced real-time beta-attenuation particulate quality monitoring systems reset. monitor suitable for urban, roadside and background Designed with the user in mind, ET’s systems are monitoring. Features automatic calibration checking compact, simple to operate, easy to maintain and system, large internal data storage facility and are guaranteed "future-proof". A wide range of integral 8-channel data logger for logging other continuous gas, dust and meteorological sensors is sensors, e.g. wind speed and direction. US-EPA, available and analysers and sensors can either be UK Equivalent Method*. used together as an integrated system or as stand- Specialist applications: TSP, PM10 and PM2.5. alone units. Adding a new analyser is simple – just BAM 1020 plug in to the digital RS232 switch and make a E-Sampler quick change in the EnviMan software. The E-Sampler is the most feature-packed light- Specialist applications: SO2, NO, NO2, NOX, CO, O3, VOCs, scatter Aerosol Monitor available. Whatever your Benzene, 1.3 Butadiene, H2S, N2O, NH3 and others. PM10, monitoring need the E-Sampler will provide PM2.5, TSP and meteorological sensors. accurate, dependable and relevant data. The E-Sampler is a dual technology instrument that VOC Analyser combines the unequalled real-time measurement of Compact design, continuous gas chromatograph light scatter with the accuracy standard of filter PID for measuring VOCs including benzene, toluene, methods. The simple filter loading process testifies xylene, BTX and 1.3 butadiene. An ideal VOC analyser to the seamless blending of both technologies. for urban, roadside and background monitoring. Specialist applications: Vinyl chloride and ethylene oxide. M200E NOx Analyser ET Project Management SM 200 & Installation Team Aerocet 531 *Shown to meet equivalence criteria set out in the report on ‘UK equivalence programme for monitoring of particulate matter’. (See www.airquality.co.uk/archive/reports/cat05/0606130952_UKPMEquivalence.pdf)
  3. 3. Industrial Health and Continuous Emissions Safety Equipment Monitoring Aerocet ET Multi-gas Cross Duct Particulate Mass Monitor and Particle counting in a Monitoring Systems single unit. The 531 combines hand-held portability Using differential optical absorption spectroscopy with highly precise measurements. Data records are (DOAS), ET systems can simultaneously measure a stored in memory and may be transferred to a PC wide range of industrial pollutants in stacks, ducts using the supplied software or printed using the or flues with no part of the system coming into optional portable printer. physical contact with the sample. A remarkably flexible, higher performance Specialist applications: SO2, NO, NO2, CO, CO2, NH3, VOCs, HCL and HF. instrument featuring: • Operates as either a particulate counter ET Compact Analysers and LD500 or mass monitor For simple, single gas monitoring, ET Compact • Battery-operated, hand-held Analysers represent excellent value and can be up • Two channel particle counter and running within a few hours. Based on the • PM1, PM2.5, PM7, PM10 or reliable and time-proven dilution extraction Total Suspended Particulates technique, no complicated heated sample systems As a mass particular monitor, particles are detected, are required, meaning operator maintenance and sized and counted in multiple size ranges. Mass sample conditioning is kept to an absolute minimum. conversion is made using standard conversion The LD500 Laser Diode Analyser is a simple, cost- factors, or by using user-programmable factors effective and reliable monitor using tuneable based on unique conditions. The particle mass can wavelength laser technology. be displayed as PM1, PM2.5, PM7, PM10 or Total Suspended Particulates. Specialist applications: HF, H2O, HCI, NH3, CO, CO2, H2S, O2, CH4. When configured as a particle counter, size-based particle counts are displayed as cumulative (counts ECA 450 Analyser above threshold) above 0.5 and 5.0 microns, the The ECA 450 determines the burner efficiency of two most popular size ranges. furnaces, boilers and other industrial combustion equipment helping plants reduce fuel costs whilst monitoring and analysing pollutant levels. EPA/ETV Particulate Sampling test verified for NOx emissions, the ECA 450 has the most user-friendly interface currently available and MiniVol Portable Air Sampler provides accurate measurements of O2, CO, NO, Portable sampling device weighing less than 10kg NO2, SO2, and calculates combustion efficiency, and measuring only 50cm high, the MiniVol is excess air, carbon dioxide and NOx. compact, rugged, battery operated and can be Specialist applications: Plant maintenance, industrial hung from trees, poles, street lights or supported boiler/furnace servicing, energy co-ordination, compliance studies, and environmental on its own tripod. and Health & Safety audits. Specialist applications: TSP, PM10 and PM2.5. CEN 12341 Gravimetric Samplers The single filter LVS3 (Kleinfilter) is the EU reference method for particulate sampling in accordance with Council Directive CEN EN12341. Also available, the 15 filter sequential sampler is suitable for long periods of unattended operation whilst also meeting CEN 12341. Rugged, reliable and fully EU approved, these samplers can be used for a multitude of urban ECA 450 Analyser and industrial applications. Specialist applications: Ambient air quality monitoring.
  4. 4. EnviroHire Vehicle Emission Indoor Monitoring Air Quality Remote Sensing Device (RSD) - Graywolf Accuscan Graywolf's DirectSense provides Indoor Air Quality This quick, unobtrusive drive-by measurement using software, interface and sensor technology system enables vehicle emissions to be tested that unleashes the power of Microsoft Mobile “in-situ”. The main benefit of this technology is Windows Pocket PCs, as well as Notebook, Tablet that the motorist is not required to stop for a and Laptop computers for accurate, easy, efficient, manual exhaust pipe test, which is labour upgradeable, thoroughly documented monitoring. intensive and often requires a police presence. Application tips, industry documents and an The system's digital camera photographs each extremely intuitive user interface are loaded on the Graywolf DirectSense vehicle's registration plate and advanced software mobile PC. Detailed data collection and reporting merges vehicle registration information with the has never been easier. Graywolf also manufactures emissions result and registration plate image. Classical Line Instruments for IAQ, IH, HVAC, ∆P The entire process is accomplished in a fraction of and other applications. a second. RSD measures fine particulate matter The DirectSense IAQ monitor from Graywolf makes (PM and PM2.5) - the most harmful pollutants in proactive indoor air quality surveys efficient and diesel exhaust with greater accuracy than basic easy to conduct. Optimise the balance between opacity testing. RSD also measure carbon facility energy efficiency and occupant health and monoxide, hydrocarbons and nitrogen in diesel comfort. Identify potential IAQ issues before they exhaust. become problems and respond immediately to complaints with the most advanced, most accurate and most intuitive portable IAQ monitors and test Housings and instrumentation available today. Enclosures • Measure Carbon Dioxide (dilution ventilation), Carbon Monoxide, %RH, temperature, DewPoint and more Mobile and Static A wide range of systems housings, from roadside • Options for TVOCs, particle counts, toxic gases, airflow, differential pressure and more cabinets and mobile trailers to permanent, fully- air conditioned enclosures is offered. • Store enhanced survey information on site; data and text, drawings, audio notes and Housings can be customised to meet individual photographs operational requirements including anti-vandal, high security features; structures designed to • On-board “hand holding”: IAQ educational materials, IAQ and sensor tips, government blend with existing surroundings and/or comply and industry guidelines, health effects, typical with local planning restrictions; and units to background levels and more satisfy specific Health and Safety regulations. • Add your own IAQ related procedures, documents and Word field forms for on-site use • Extremely easy to use • Desktop data analysis and reporting software is included • Optional “Advanced Report Generator: IAQ Edition” software makes comprehensive IAQ Monitoring report generation easy and efficient. for Life EnviroTechnology Services plc Advanced Environmental Systems - Sales, Hire and Services Kingfisher Business Park, London Road, Stroud, Gloucestershire, GL5 2BY Tel: +44 (0)1453 733200 Fax: +44 (0)1453 733201 Email: info@et.co.uk www.et.co.uk

×