  1. 1. SIST M AL E ARM & P M RCIK E E 1
  2. 2. SIST M AL E ARM K B ARAN E AKSISTEM ALARM KEBAKARAN ADALAH SISTEM INSTALASI ELEKTRONIKYANG BERFUNGSI UNTUK MEMBERITAHU ADANYA SUMBER GEJALAAPI KEBAKARAN SEDINI MUNGKIN SEJAK SAAT-SAAT AWAL GEJALAITU MUNCULINFORMASI ADANYA SUMBER API BISA DINYATAKAN DALAM BENTUKZONE AREA KEBAKARAN MELIPUTI LUASAN TERTENTU, ATAUDINYATAKAN DALAM TITIK (POINT) KEBAKARAN YANG MELIPUTIRUANGAN TERTENTUINFORMASI LOKASI KEBAKARAN DIKIRIM DALAM BENTUK SINYALLISTRIK INPUT DARI SUMBER API KE SENTRAL KONTROL DIRUANGAN KONTROL MELALUI KABEL YANG SETELAH DIPROSESSECARA ELEKTRONIK AKAN MENGHASILKAN SINYAL LISTRIKOUTPUT YANG AKAN MEMBUNYIKAN ALARM BELL DAN MENYALAKANSAKLAR LISTRIK
  3. 3. PR E ANGK SIST M AL AT E ARM1. DETECTOR Terdapat beberapa jenis DETECTOR tergantung gejalaKebakaran yang dideteksinya : SMOKE DETECTOR Alat ini bekerja apabila Ion asap memasuki ruang deteksi radio aktif sehingga terjadi perubahan perbandingan partikel Ion + (positif) dan Ion negatif yang mengakibatkan rangkaian electrik contactmenjadi aktif. Biasanya alat ini digunakan apabila dibutuhkan deteksi seawal mungkin untuk suatu ruangan seperti ruang computer,arsip,akan tetapi ruangan tersebut tidak diperkenankan merokok.
  4. 4. HEAT DETECTORAlat ini bekerja apabila panas yang masuk pada ruang deteksi naik7-10 derajat perdetik sehingga perbedaan panas kedua ruangandeteksi berbeda yang m,rngakibatkan mechanikal contactmenjadiaktifBiasanya alat ini digunakan sebagai,alat deteksi panas biasa untukruangan2 kantor , hotel , pusat perbelanjaan.
  5. 5. FLAME DETECTORAlat ini bekerja apabila terdapat api sehingga sinar ultra violet yangdipancarkan dapat ditangkap oleh deteksi ultra violetmengakibatkan rangkaian electronik – contact menjadi aktifAlat ini digunakan untuk deteksi ruangan yang agak besar / tinggiatau ruangan yang menyimpan barang2yang mudah terbakarseperti gudang mesiu, minyak, bahan kimia. 5
  6. 6. 1. MASTER CONTROL PANEL FIRE ALARM (MCFA)ADA 2 (dua) JENIS MCPFA A. CONVENTIONAL SYSTEM UNTUK MENUNJUKKAN LOKASI KEBAKARAN, MAKA RUANGAN- RUANGAN PADA SATU LANTAI DIBAGI KEPADA BEBERAPA ZONE AREA KEBAKARAN. PEMBAGIAN ZONE INI UNTUK MEMUDAHKAN INFORMASI BAGI PETUGAS PEMADAM AGAR BERGERAK CEPAT DAN EFFEKTIF MENUJU SUMBER API, UNTUK PENGECEKAN DAN PENANGGULANGAN KEBAKARAN, PENENTUAN ZONE INI DISESUAIKAN DENGAN LOKASI TANGGA KEBAKARAN, MISSAL : ZONE 20 T = LANTAI 20 AREA TIMUR. PENENTUAN AREA 1 ZONE DITENTUKAN JUGA OLEH JUMLAH DETECTOR DALAM ZONE TERSEBUT. A. ADDRESSABLE SYSTEM UNTUK INFORMASI LOKASI API YANG LEBIH AKURAT DIGUNAKAN SISTEM ALAMAT TITIK API (ADDRESS POINT), DIMANA INFORMASI SUMBER KEBAKARAN BERUPA TITIK LOKASI YANG LEBIH JELAS DAN PASTI, MISALNYA RUANG FOTO COPY, RUANG PANEL LISTRIK.
  7. 7. PERANGKAT KERAS YANG ADA DIDALAM MCFA ADALAH : 1. MAIN CONTROL UNIT (Central Processing Unit) 2. INPUT/OUTPUT MODULE 3. INDICATOR LAMPS & DISPLAY 4. OUTPUT BUZZER / SOUNDER / AUDIBLE DEVICE 5. SWTICTH & BUTTON FOR CONTROL, TEST & RESET 6. POWER SUPPLY UNIT & BATTERY CHARGER 7. INTERFACE KE ANNUNCIATOR, PC DAN PRINTERPROGRAM (SOFTWARE) YANG DIKERJAKAN OLEH MCPFA ADALAH : 1. MEMONITOR DETEKSI SUMBER KEBAKARAN 2. MEMBERI INFORMASI MENGENAI LOKASI SUMBER KEBAKARAN 3. SECARA OTOMATIS MELAKUKAN ANNOUNCEMENT, EVAKUASI DAN TINDAKAN PENGENDALIAN DALAM RANGKA PENANGGULANGAN KEBAKARAN MELALUI PERALATAN- PERALATAN MEKANIKAL & ELEKTRIKAL YANG SUDAH DISIAPKAN. 4. MEREKAM DATA INFORMASI KEBAKARAN 5. MENYEDIAKAN SARANA MANUAL UNTUK PENGENDALIAN BERUPA MMI (man to Mchine Interface)
  8. 8. 1. ALARM BELL ALARM BELL BERFUNGSI UNTUK MEMBERIKAN PERINGATAN DINI BAGI SELURUH PENGHUNI GEDUNG KARENA ITU DIPERLUKAN UKURAN FISIK DAN KEKUATAN SUARA YANG MEMADAI UNTUK MEMENUHI FUNGSI TERSEBUT. UKURAN FISIK UMUMNYA BERDIAMETER 6 INCH. KEKUATAN SUARA (SOUND PRESSURE LEVEL = SPL) SEKITAR 87 Db/1 m SAMPAI 90 Db/1m BEKERJA DENGAN 24 VDC DARI SENTRAL DALAM MENILAI MUTU ALARM BELL DIPERHATIKAN MENGENAI ALARM CURRENT (mA) DAN SOUND PRESSURE LEVEL (SPL) DALAM Db/1 m. PATUT DIPERHATIKAN BAHWA PARTISI RUANGAN BAIK KAYU, BATA NAUPUN BETON AKAN MENGAKIBATKAN REDAMAN TERTENTU PADA LEVEL SUARA BELL.
  9. 9. 1. ALARM LAMP ALARM LAMP DITEMPATKAN DI AREA PUBLIC ATAU ESCAPE ROUTE DEKAT MANUAL ALARM. BERGUNA UNTUK MENUNJUKKAN LOKASI MANUAL ALARM SEKALIGUS MEMBIMBING KEARAH JALAN YANG AMAN PADA SAAT EVAKUASI. BEKERJA DENGAN TEGANGAN 24 VAD/VDC – 21 mA DARI SENTRAL1. CONTACTOR CONTACTOR LISTRIK BERADA PADA PANEL LISTRIK PERALATAN MEKANIKAL & ELEKTRIKAL YANG ADA HUBUNGANNYA DENGAN KEBAKARAN. DIGUNAKAN UNTUK MENERIMA SINYAL PENGENALIDAN DARI SENTRAL FIRE ALARM, BAIK UNTUK ON MAUPUN OFF.
  10. 10. 1. MIMIC PANEL MERUPAKAN PANEL LAMPU YANG DIPASANG DI DINDING, YANG MUDAH DILIHAT DARI PINTU RUANG PUSAT KENDALI KEBAKARAN. BERISI INFORMASI MENGENAI ZONE AREA KEBAKARAN DAN AKTIFITAS PERALATAN M & E YANG IKUT BERPERAN DALAM PENANGGULANGAN KEBAKARAN. PANEL DILENGKAPI DENGAN ALARM LAMP, BUZZER, TEST BUTTON DAN SILENCER/RESET BUTTON. HUBUNGAN ANTARA MIMIC PANEL DENGAN MCPFA MELALUI KABEL DATA. UKURAN SEKITAR 80 cm x 120 cm ATAU DISESUAIKAN DENGAN KEBUTUHAN.
  11. 11. PRINSIP K RJ AL E A ARM K B ARAN E AK ADANYA GEJALA SUMBER BAHAYA KEBAKARAN BISA MUNCUL DALAM BEBERAPA INDIKASI : SUHU YANG TINGGI, KENAIKAN SUHU YANG CEPAT, ADANYA ASAP, ADANYA BUNGA API (PERCIK), ADA KEBOCORAN GAS, GETARAN GEMPA BUMI DAN KEBOCORAN LISTRIK. 1. SUHU KEADAAN RAWAN SEBAGAI SUMBER BAHAYA KEBAKARAN BERDASARKAN INDIKASI SUHU ADALAH : a. SUHU RUANGAN MENCAPAI 520 C – 57o C/MENIT UNTUK FIXED TEMPERATURE b. KENAIKAN SUHU DENGAN KECEPATAN 10o C /MENIT UNTUK RATE OF RISE
  12. 12. 1. ASAP KEADAAN RAWAN SEBAGAI SUMBER BAHAYA KEBAKARAN BERDASARKAN INDIKASI ASAP ADALAH MUNCUL DAN NAIKNYA ASAP YANG MENYEBABKAN LEVEL CAHAYA RUANGAN MENURUN SEBESAR 0,1 – 0,3 % ft LIGHT OBSCURATION (PENGABURAN CAHAYA)1. BUNGA API KEADAAN RAWAN SEBAGAI INDIKASI SUMBER BAHAYA KEBAKARAN ADALAH TERLIHAT ADANYA BUNGA API ATAU PERCIK API YANG UMUMNYA MEMANCARKAN SINAR INFRA MERAH.
  13. 13. 1. MANUAL ALARM POINT PERANGKAT INI BERUPA SWITCH YANG MENJADI ON BILA DITEKAN OLEH SESEORANG YANG INGIN MEMBERITAHU LANGSUNG KE SENTRAL, BAHWA ADA BAHAYA API KEBAKARAN DI AREA SEKITAR MANUAL ALARM POINT. MANUAL ALARM POINT TERDIRI DARI : A. TARIK B. TEKAN C. TEKAN - TARIK
  14. 14. SPRINKLER Adalah suatu sistim instalasi pemadam kebakaran yang dipasangsecara tetap/permanen didalam bangunan yang dapatmemadamkan kebakaran secara otomatisdengan menyemprotkanair ditempat mulai terjadi kebakaran.1. Kepadatan Pancaran Jumlah debit air ( liter/menit ) yang dikeluarkan oleh 4 kepala splingkler yang berdekatan dan terletak di empat sudut bujur sangkar2. Penyedian air. Volume air - Bahaya kebakaran ringan : minimal masa pakai 45 menit - Bahaya kebakaran sedang ; minimal masa pakai 60 menit - Bahaya kebakaran berat ; minimal masa pakai 90 menit
  15. 15. - Sumber air Air dari sumur pompa atau dari perusahaan air minum dengan kualitas air bersih.3. Pompa Sprinkler - mampu mensuplai air dalam kapasitas besar, daya dorong cukup tinggi - Karakteristik dan kinerja pompa paling cocok untuk pompa kebakaran4. Motor penggerak - motor listrik - motor diesel5. Panel pompa harus dapat mengalihkan arus listrik konstant kepompa dengan pengaturan start otomatis dengan stop manual.
  16. 16. 6. Penyedian pompa - pompa pembantu ( jocky pump ) - pompa utama - pompa cadangan7. Ruang pompa - mudah dicapai - ruang gerak bebas sehingga mudah melakukan perbaikan,pemeliharaan - nyaman - tidak banjir - bebas dari barang yang mudah terbakar - bebas dari penempatan barang lainnya.
  17. 17. 7. Kapasitas pompa - kemampuan pompa untuk mensuplai volume air - kemampuan pompa untuk mendorong volume air - kemampuan untuk menghisap air dari permukaan sampai ke poros pompa
  18. 18. Kapasitas pompa untuk sprinkler Tersendiri disesuaikan dengan klasipikasi sprinkler Gabungan dengan hidran8. Pemipaan Bahan Pipa: disesuaikan dengan perhitungan hidrolik atau skedul pipa - pipa tembaga - black steel - Galvanized - Besi tuang dengan flaus - besi tuang dengan motJenis Pipa - Pipa hisap - Pipa Pembagi - Pipa Utama - Pipa Cabang - Pipa Tegak - Pipa Pembagi Utama
  19. 19. Terima Kasih

×