Viking ® Non-Metallic Mag Drive Pumps                                      Sealless, Non-Metallic Pumps                   ...
Viking Reliability in a Sealless, Non-metallic Gear Pump                 ®CMD Mag Drive Series outer magnets are turned by...
ApplicationsCorrosive Chemicals                                                                    Volatile Organic Chemic...
Viking CMD Series Gear Pump Benefits                              ®                      ■ Innovative Magnet System       ...
■ Bi-directional Pump Design                                Bi-directional pumping design eliminates cost                 ...
Materials of Construction  SpecificationsCMD Gear Pump Construction                                                       ...
DimensionsDimensions For E02, E05  E12           (Top View)                                                               ...
Worldwide Leader Since 1911 for Positive Displacement                                                 Pumping Solutions fo...
Upcoming SlideShare
Loading in...5
×

Cmd brochure

261

Published on

Published in: Business
0 Comments
0 Likes
Statistics
Notes
  • Be the first to comment

  • Be the first to like this

No Downloads
Views
Total Views
261
On Slideshare
0
From Embeds
0
Number of Embeds
0
Actions
Shares
0
Downloads
1
Comments
0
Likes
0
Embeds 0
No embeds

No notes for slide

Cmd brochure

  1. 1. Viking ® Non-Metallic Mag Drive Pumps Sealless, Non-Metallic Pumps for Crucial Liquid Containment Applications Capacity to 75 LPM (20 GPM) Pressure to 10 Bar (150 PSI) Viscosity 0.8 to 5,000 cSt (28 to 25,000 SSU) Temperature -40°C to +65°C (-40°F to +150°F)Universal Flanges & Motor Adapters• Standard Housing Mates to Both DIN and ANSI Flange Systems• Standard Adapters Mate to Multiple NEMA and IEC Motors
  2. 2. Viking Reliability in a Sealless, Non-metallic Gear Pump ®CMD Mag Drive Series outer magnets are turned by a motor, and their magnetic force passesthrough the hermetically sealed canister causing the rotation of the Mag Drives inner magnets. Theinner magnets turn the drive gear shaft, which turns the driven gear, carrying the liquid from the Marketssuction to discharge port. The CMD Series pumps combine a proven design with state-of-the-artengineered composites for a structurally rugged, reliable, simple-to-service pump with a lower costof ownership. ChemicalThe Viking AdvantagesAdvanced DurabilityViking’s CMD series external gear pump is made of engineered fluoropolymers with superior corrosion Food & Beverageresistance and strength over a broad range of chemicals and temperatures. Its sealless design eliminates CMD Series Benefitspotential leak points, as well as the eddy current energy loss and heat rise common in metallic pumps. Vs. Other Mag Drive Gear Pumps:Fully encapsulated, self-aligning magnets use patent pending spline design allowing them to "float" on the • CMD offers one of the broadest Pharmaceuticaldrive shaft without inducing axial loads, extending service life. With short-term run-dry capabilities supplied ranges of chemical resistance in theby a patent pending bearing design, the CMD series has built-in protection during system upset conditions market, enabling one pump to besuch as closed suction valve or empty supply tank. used on many different liquids. MiningEase of Installation Vs. Non-metallic Mag DriveA unique, universal flange design provides easy installation to both ANSI and DIN flanged systems alike. Centrifugal Pumps:Its robust construction and rigid pump base with slotted holes makes retrofitting of existing installations • CMD offers high efficiencies, usuallysimple. The close-coupled mounting eliminates the traditional alignment issues with pump and motor for reducing energy usage, Dyes Paints & resulting inquicker, easier installation. The CMD Series modular design of magnet hub provides one drive magnet lower life cycle cost than centrifugals.per pump size, with interchangeable adapter-hubs to fit both standard NEMA and IEC motors. • CMD offers flow proportional toApplication Flexibility speed, allowing use in chemical PetroleumViking’s CMD series non-metallic construction delivers a broad range of chemical compatibility. Its metering applications.sealless design provides trouble-free performance where liquid containment is crucial to environmental • CMD handles viscosities from lessrequirements. This pump series is ideally suited for low-flow operation where centrifugal pumps perform than 1 to 5,000 cSt, enabling use ofinefficiently and can experience cavitation, increased radial loads and unstable flow. Designed with simple one pump on many different liquids. Petrochemicalserviceability in mind, you can replace all of the typical wear components easily by removing only the frontcover, maximizing uptime. Vs. Diaphragm Metering Pumps: • CMD handles entrained gases better,Lower Cost of Ownership resulting in lower chance of vapor Pulp & PaperNon-metallic construction eliminates the need for expensive alloys. Sealless design eliminates service lock on liquids that off-gas, likerequirements of mechanical seals and expensive seal flush systems. Run-dry capabilities provide sodium hypochlorite.protection against system • CMD offers continuous flow insteadupsets without catastrophic Performance Envelope Power & Energy of pulsating flow, to eliminate “slug”failure. Advanced design 10 20 30 40 50 60 70 feeding of chemicals and ensureutilizes fewer parts (16 150 10 better mixing.fabricated parts) minimizing Pressure (PSI) 7.5 • Vertical porting option allows Pressuremaintenance time and 100 Water Treatment (Bar) 60 Hz – 1750 RPM 5 replacement of diaphragm meteringinventory requirements. 50 2.5 pumps with minimal repiping.Patent pending casing liner 0 5 10 15 20transfers wear from casing Capacity (GPM) Vs. Air Operated Double General Industriesto replaceable liner, which 10 20 30 (LPM) 40 50 60 70 Diaphragm (AODD) Pumps:is part of the recommended 150 10 • CMD electric motor drive ensuresspare parts kit, to provide Pressure (PSI) 7.5 lower energy usage than compressed Pressure 100cost-effective, 100% renewal 50 Hz – 1450 RPM (Bar) 5 Steel Industries air, usually resulting in lower life cycleof CMD pump efficiency and 50 2.5 cost than AODD pumps.performance for a lower total 0 5 10 15 20 • Eliminates pulsation.cost of ownership. Capacity (GPM) Viking CMD Series
  3. 3. ApplicationsCorrosive Chemicals Volatile Organic Chemicals Flammable LiquidsThese pumps handle a broad pH range, allowing the same pump These pumps use a magnetic drive system to eliminate the mostto be used for a variety of liquids. They are designed for metering common source of pump leakage and vapor emissions, the shaftliquids in process control systems as well as for simple tank-to-tank seal. This helps protect employees and the environment, and ittransfer. The fluoropolymer and ceramic wetted materials in these prevents infiltration of air into the pump to protect liquids that reactpumps are compatible with many corrosives, yet are more affordable with air or water vapor.than pumps made of Alloy 20, Alloy C, titanium and other exotic Typical Applications:materials required to handle some highly corrosive materials. • Solvents: Acetone, TolueneTypical Applications: • Refrigerants: Freons, Ammonia• Acids: Hydrochloric, Nitric, Phosphoric, Sulfuric • Refined Fuels: Ethanol, Biodiesel• Bases: Sodium Hydroxide • Adhesives: Cyanoacrylate, Epoxies• Coagulants: Ferric Chloride • Odorants: Mercaptans, Fragrances, Aldehydes• Disinfectants: Sodium Hypochlorite • Organics: Formaldehyde, Vinyl Chloride MonomerModel Number KeyCMD - E02 E L V F - X Series: Model: Materials/Ports: O-Rings: Options: Composite Mag Drive E02 E = ETFE, FNPT V = Viton® A = Bearing Flush Ports E05 (E02, E05, E12) E = EPDM B = Combination of Options A and N E12* B = ETFE, ISO 7-1 N = Without Drive Magnet E25* (E02, E05, E12) X = Complete Pump (No Options) E75* F = ETFE, Flange (E25, E75) Mounting Arrangement: F = NEMA 56C (E02, E05, E12, E25) Bearings: O = NEMA 143TC-182C (E05, E12, E25, E75) L = Carbon Graphite R = NEMA 182TC-184TC (E75) B = Graphite-Impregnated H = IEC B34 63 (E02, E05, E12) Silicon-Carbide K = IEC B34 80 (E02, E05, E12) P = IEC B14 100/112 (E25, E75)* Export license required under U.S. Export Y = No Motor Mount Kit (E02, E05, E12, E25, E75) Administration ECCN 28350 and 28999.Viton® is a registered trademark of DuPont Performance Elastomers. Viking CMD Series
  4. 4. Viking CMD Series Gear Pump Benefits ® ■ Innovative Magnet System % Temperature Rise During Dry Run Patent pending spline design allows the magnet to self-align on shaft with no added fasteners. Eliminates axial loading on shaft, extending % Temperature Rise pump life.ADVANCED DURABILITY ■ Heavy-Duty Bearings Self-lubricating materials and patent pending geometry allow dry-run capabilities and generates cooling flow through canister. Provides built-in protection against system upset, extending pump life, allowing vertical mounting. Time (Minutes) ■ Short-term Run-Dry Capabilities ■ Non-Metallic Magnet Canister High efficiency, self-priming pump with short-term, run-dry capabilities. Minimizes heat rise and magnet inefficiencies due Provides protection against system upsets without catastrophic failure. to eddy current losses found in metallic canisters. Minimizes heat rise to protect sensitive fluids. ■ Unique, Universal Flange Universal flange design uses replaceable PTFE raised face flange inserts for easy installation to both ANSI and DIN flanged systems. Eliminates flange adapters, simplifying installation into virtually any system. ■ Rigid Pump Base (E25 E75 only)EASY INSTALLATION Robust, corrosion resistant base offers optimum pump support in harsh environments. Slotted holes in base permit easy retrofitting of existing installations. ■ Close-Coupled Mounting Eliminates coupling, guard, and the cost and issues associated with pump and motor alignment. Provides quicker, easier installation. ■ Rotatable Casing 3 smaller sizes have rotatable, motor mount casing with NEMA or IEC adapters. Permits horizontal or vertical porting for easier installation. Viking CMD Series
  5. 5. ■ Bi-directional Pump Design Bi-directional pumping design eliminates cost of second pump, piping, and valving needed for loading/unloading or line stripping. Provides APPLICATION FLEXIBILITY application flexibility and reduces system costs. ■ Modular Magnet Hub and Universal Motor Adapter One drive magnet per pump size, with inter- changeable adapter-hubs. Provides easy mating to fit either standard NEMA or IEC motors. ■ Broad Chemical Compatibility CMD Series wetted components are made of Engineered Fluoropolymers, Ceramic and Carbon Graphite-Impregnated Carbide with excellent corrosion resistance and strength over a broad range of chemicals and temperatures. Enhances application flexibility ■ Easy To Assemble Better design with self-aligning parts and piloted fits ensure proper assembly every time. Significantly reduces maintenance costs and parts inventory needs for a lower cost of ownership. LOWER COST OF OWNERSHIP ■ 10 Minute Maintenance CMD series normal wear components can be replaced without detachment of pump from system and no special tools required. Reduces down time and maintenance costs, for lower cost of ownership. ■ Simple Design Advanced non-metallic design utilizes fewer parts (16 fabricated parts) to simplify servicing. Minimizing Kit maintenance requirements and inventory rts requirements. Pa are d Sp de ■ Renewable Performance men om Regain 100 % performance with the change ofRec a recommended spare parts kit, to keep pump running optimally. Provides cost-effective renewal of pump performance and efficiency. Viking CMD Series
  6. 6. Materials of Construction SpecificationsCMD Gear Pump Construction Inner Magnet Outer Magnet Construction Casing / Head Gears Canister Assembly Assembly Shafts Bearings O-Rings Carbon Carbon Carbon ETFE Nickel- Alumina Standard Reinforced Reinforced Reinforced Encapsulated Plated Steel / Carbon Graphite Viton® Ceramic ETFE PTFE ETFE Neodymium Neodymium Graphite-Impregnated Optional N/A N/A N/A N/A N/A N/A EPDM Silicon-CarbideCMD Gear Pump Specifications 22 cSt (100 SSU) Ports Performance Nominal Nominal Maximum Maximum Maximum Approximate Capacity at Capacity at Differential Hydrostatic Recommended Shipping 1450 RPM 1750 RPM Pressure Pressure Temperature Weight Pump Size Model Type in. GPM LPM GPM LPM BAR PSI BAR PSI Deg. C Deg. F kg. lb. NPT E02 1/4 0.34 1.3 0.4 1.5 10 150 14 200 65 150 2 4 ISO 7-1 NPT E05 3/8 1.3 4.9 1.5 5.8 10 150 14 200 65 150 5 9 ISO 7-1 NPT E12 3/4 2.6 10.0 3.2 12.1 10 150 14 200 65 150 6 10 ISO 7-1 ANSI Flg. E25 1 5.5 21.0 6.5 24.6 10 150 14 200 65 150 12 26 DIN Flg. ANSI Flg. E75 1-1/2 16.5 62.5 20.0 75.0 10 150 14 200 65 150 20 44 DIN Flg. Viton® is a registered trademark of DuPont Performance Elastomers. Viking CMD Series
  7. 7. DimensionsDimensions For E02, E05 E12 (Top View) (Side View) (Front View) Model A B C D E F G P R X mm 1/4 Inch FNPT 183.50 154.40 6.40 80.20 34.90 69.90 193.00 147.60 76.20 E02 in. or ISO 7-1 7.22 6.08 0.25 3.16 1.38 2.75 7.60 5.81 3.00 mm 3/8 Inch FNPT 201.20 160.30 11.90 85.60 38.10 76.20 210.70 147.60 96.80 E05 in. or ISO 7-1 7.92 6.31 0.47 3.37 1.50 3.00 8.93 5.81 3.81 mm 3/4 Inch FNPT 217.00 168.30 11.90 85.60 47.60 95.30 226.60 147.60 96.80 E12 in. or ISO 7-1 8.54 6.63 0.47 3.37 1.88 3.75 8.93 5.81 3.81NOTE: Pumps must be mounted to a footed motor with a face (NEMA C or Metric B34). Will accept motors with or without a foot/rigid base. Pump foot is removable.Dimensions For E25 E75 A - Port Dimensions Dim “A” Dim “B” Model Flange IN (mm) IN (mm) ANSI 1” RF 150 LB. .62 (15.7) 3.12 (79.2) E25 DIN 20 RF 10 BAR .68 (17.3) 2.95 (75.0) DIN 25 RF 10 BAR .68 (17.3) 3.35 (85.0) ANSI 1.5” RF 150 LB. .62 (15.7) 3.88 (98.4) E75 DIN 32 RF 10 BAR .68 (17.3) 3.94 (100.1) DIN 40 RF 10 BAR .68 (17.3) 4.34 (110.1) (Side View) (Foot Plate Only) (Front View) Model B C D E F G J K L M N O P R S T V X Y Z mm 111.10 127.00 114.30 190.50 215.90 254.00 206.40 17.50 22.20 277.10 294.6 19.10 15.90 215.90 215.90 158.8 19.00 38.10 31.7 19.00 E25 in. 4.38 2 X 5.00 4.50 2 X 7.50 2 X 8.50 10.00 8.12 0.69 0.88 10.91 11.6 0.75 0.62 8.50 8.50 2 x 6.25 2 x .75 2 x 1.50 2 x 1.25 2 x .75 mm 127.10 127.00 136.50 190.50 215.90 254.00 241.30 25.40 57.10 349.60 375.00 19.10 23.80 257.20 215.90 158.80 19.00 38.10 31.7 19.00 E75 in. 5.00 2 X 5.00 5.38 2 X 7.50 2 X 8.50 10.00 9.50 1.00 2.25 13.77 14.77 0.75 0.93 10.12 8.50 2 x 6.25 2 x .75 2 x 1.50 2 x 1.25 2 x .75NOTE: Pumps must be mounted to a motor with a face (NEMA C or Metric B34). Will accept motors with or without a foot/rigid base. Pump foot is removable. Viking CMD Series
  8. 8. Worldwide Leader Since 1911 for Positive Displacement Pumping Solutions for Industrial, OEM, andA Unit of IDEX Corporation Sanitary Applications.Innovation and Experience Material Options Matched to Quality ManufacturingViking Pump has been a pump industry Application Viking uses ISO9001-2000, ISO14001,leader and innovator since its founding in Vikings dedicated iron and alloys foundries Six-Sigma, and Lean/Kaizen in its worldwide1911. We continue to build on our ever provide pump construction materials from manufacturing and assembly processes togrowing experience delivering innovative new cast iron to Hastelloy®. Application-specific remove waste, reduce development costs,pumping solutions, including custom designs, materials of construction extend pump life and deliver superior products on schedule.to many thousands of customers who use significantly, while reducing maintenance Dedicated Viking foundries and manufacturingmillions of Viking ® pumps in some of the world’s and unplanned downtime, which enables facilities utilize state-of-the-art CNC equipmenttoughest applications. increased production and a better bottom line. to assure unmatched quality is built into every pump. Viking products also meetBroad Performance Range Liquid Integrity Protection the applicable standards or certificationCapacity: Viking has developed multiple positive requirements for ATEX, CE, DIN, EHEDG,0.5 to 360 M³/Hr (0.1 to 1600 GPM ) displacement pump principles to protect BSP, JIS, ANSI, UL, 3-A and others.Pressure: shear-sensitive liquids, and low-shear options0 to 172 Bar (0 to 2500 PSI) to prevent damage to fibers, polymers, and Custom Designed SolutionsTemperature: Viking has provided custom designed pumps solids. Full-jacketing options provide precise-40°C to 370°C (-40°F to 700°F) temperature control throughout the pump. to end-users and OEMs since its first pumpViscosity: The Viking Mag Drive® and other seal options in 1911, when Viking invented the gear-within-0.5 to 1,000,000 cSt (28 to 4,500,000 SSU) prevent fluid contact with air, assuring liquid a-gear pumping principle to remove water integrity. from a rock quarry. Today, enabled by VikingsUltimate in Sealing Solutions engineering staff, extensive applicationsViking’s offering of packing, componentmechanical seals, cartridge seals, and Local Applications and experience, and in-house foundries, moresealless Mag Drive technology provides the Engineering Support than 20% of Vikings sales are new Viking Over 245 Authorized Viking Pump Distributors in designs, or pumps designs derived from morebest choices for sealing flexibility needed to 68 countries provide local application support and than 1000 Viking catalog pumps with more thanprovide your application a customized sealing service, backed by Viking Application Engineers 40,000 active configurations. So, whether yousolution every time - saving you money, time, and Viking Region Managers strategically are an end-user or an OEM, Viking can provideand unplanned downtime. located around the world. custom designed pumping solutions to meet your specific needs. For more information, contact your local authorized Viking Pump Distributor or contact Viking at:VIKING PUMP, INC.A Unit of IDEX CorporationP.O. Box 8Cedar Falls, Iowa 50613-0008 U.S.A.Telephone: (319) 266-1741Fax: (319) 273-8157Email: info.viking@idexcorp.comWeb site: www.vikingpump.comCANADA LATIN AMERICA EUROPE MIDDLE EAST ASIA-PACIFIC GROUPViking Pump of Canada, Inc. Viking Pump (Latin America) Viking Pump (Europe) Ltd. IDEX Middle East FZE Singapore China - Shanghai China - Beijing China - Guangzhou India - MumbaiWindsor, Ontario D.F. Mexico C.F. Shannon, Ireland Dubai, UAE Phone: +65-6763-6633 Phone: +86-21-5241-5599 Phone: +86-10-6522-7567/27 Phone: +86-20-3886-6156 Phone: +91-22-6678-0048/53Phone: (519) 256-5438 Phone: +52 (5) 5255-1357 Phone: +353 (61) 471933 Phone: +971-4-2257978 Fax: +65-6764-4020 Fax: +86-21-5241-8339 Fax: +86-10-6522-7563 Fax: +86-20-3886-2776 Fax: +91-22-6678-0055Fax: (519) 256-5070 Fax: +52 (5) 5255-1356 Fax: +353 (61) 475046 Fax: +971-4-2259796 www.idexapg.com www.idexapg.com www.idexapg.com www.idexapg.com www.idexapg.comwww.vikingpumpcanada.com www.vikingpumpeurope.co.uk www.idexapg.com © Viking Pump, Inc. Copyright 2007 Printed in U.S.A. 8/2007 Form No. 344-B

×