NordIq Intelligent Sub-stations save money, energy and environment

Loading...

Flash Player 9 (or above) is needed to view presentations.
We have detected that you do not have it on your computer. To install it, go here.

0 comments

Post a comment

    Post a comment
    Embed Video
    Edit your comment Cancel

    1 Group

    NordIq Intelligent Sub-stations save money, energy and environment - Presentation Transcript

    1. NordIQ Göteborg AB Intelligent Sub-stations save money, energy and environment Dr Peter Gummérus, Development Matts Lindgren, CEO gummerus@nordiq.se matts.lindgren@nordiq.se +46 736 006 202 +46 736 88 99 73 1 2009-06-18
    2. How can you save energy ? Intelligent control = stable temperature Tidsvariationer i inomhustemperatur Stable temperature = low energy consumption °C 25 Easier adjustment = better adjustment 20 Konventionellt Softcontrol Acceptansnivå More information = better energy work 15 e 11 17 19 21 23 1 3 5 7 9 13 15 m h Ti Trad °C 80 20 -20 0 20 T ute  Qegenuppvärmning  Qrad kW Tinne Tute 200  Qrad  Qväggtransm 0 -20 0 20 T ute
    3. Adjust power signature from statistics Tindoor vs TAmbient Tindoor 28 26 24 22 Internal heating 20 18 16 TAmbient -10 0 10 20 Balance temperature
    4. This is District heating Internet Sub-station
    5. Two independent evaluations Pilot project Swedish Energy Agency Gävle Energi, Familjebostäder, Göteborg Energi, Svensk Fjärrvärme, Fjärrvärmebyrån Jägarg, Gävle, 28 lgh S Köpmannag, Gävle, 39 lgh Jökelv, Gävle, 76 lgh 177 kWh/m2 112 kWh/m2 156 kWh/m2 Rävpasset, Gävle, 60 lgh Kaplansg, Gävle Gröna Vallen, Göteborg Comparison conventional vs lNordIQ 141 kWh/m2 47 lgh, 172 kWh/m2 120 lgh, 192 kWh/m2 New conventional substation 2001. NordIQ substation 2004 Result: -12% average energy consumption 12 degrees lowered return temperatures Result: Lower power demand Ny konv NordIQ Energy total +/- 0 -14% Energy heat +/- 0 -26% Return temp winter -11°C -13°C
    6. EnergyEfficiency-Process Surveillance and Energy Installation control Energy- analysis Commissioning Adjustments Follow-up Measurements Analysis 1 Measures 1 Operation year1 Analysis 2 Åtgärder år1 Åtg Substation Flow adjustment Radio sensors Vacum deair unit Driftoptimering av fjärrvärmecentraler Idrifttagning
    7. ”Det finns ingen energibrist bara effektivitetsbrist” prof Sven Werner

    + Echangeur Bordeaux AquitaineEchangeur Bordeaux Aquitaine, 4 months ago

    custom

    260 views, 0 favs, 0 embeds more stats

    NordIq : Intelligent Sub-stations save money, ener more

    More info about this document

    © All Rights Reserved

    Go to text version

    • Total Views 260
      • 260 on SlideShare
      • 0 from embeds
    • Comments 0
    • Favorites 0
    • Downloads 0
    Most viewed embeds

    more

    All embeds

    less

    Flagged as inappropriate Flag as inappropriate
    Flag as inappropriate

    Select your reason for flagging this presentation as inappropriate. If needed, use the feedback form to let us know more details.

    Cancel
    File a copyright complaint
    Having problems? Go to our helpdesk?

    Categories

    Groups / Events