    1. SAVE ENERGY – LISBON PILOT
    2. MUNICIPALITY’S MAIN OFFICE BUILDING: CAMPO GRANDE 25 MUNICIPALITY’S MAIN OFFICE BUILDING: CAMPO GRANDE 25 BRIEF BUILDING DESCRIPTION Lisbon’s Municipality main office building is located in Entrecampos and started to function in 1998, serving both as administrative office and public attending services.
    3. MUNICIPALITY’S MAIN OFFICE BUILDING: CAMPO GRANDE 25 MUNICIPALITY’S MAIN OFFICE BUILDING: CAMPO GRANDE 25 BRIEF BUILDING DESCRIPTION - approximately 1800 employees; - approximately 200 daily visits; - constituted by 6 blocs, all interconnected; - working hours from 7 am to 11 pm; - total area above the ground: 28.000 sqm; - total area under the ground : 17.000 sqm; - useful area for working places: 18.000 sqm
    4. MUNICIPALITY’S MAIN OFFICE BUILDING: CAMPO GRANDE 25 MUNICIPALITY’S MAIN OFFICE BUILDING: CAMPO GRANDE 25 BRIEF BUILDING DESCRIPTION - 25.000€ monthly electricity bill - Electricity consumption: 3491 MWh/year; - 250€ monthly gas bill; - Natural gas consumption: 327 MWh/year; - According to the Air Conditioning Energy Systems Regulation the building’s energy class is B-, with an average consumption of 50kWh/sqm.year.
    5. MUNICIPALITY’S MAIN OFFICE BUILDING: CAMPO GRANDE 25 MUNICIPALITY’S MAIN OFFICE BUILDING: CAMPO GRANDE 25 BRIEF BUILDING DESCRIPTION
    6. MUNICIPALITY’S MAIN OFFICE BUILDING: CAMPO GRANDE 25 MUNICIPALITY’S MAIN OFFICE BUILDING: CAMPO GRANDE 25 THE INTEGRATED APPROACH TO THE BUILDING Dynamic analysis of the building energy performance Identification of the opportunities matrix regarding the building optimization; Emission of the Energy and Indoor Air Quality Certificate (B-). Mobility Plan Mobility matrix for the building users: Identification of sustainable mobility strategies: smart work centres; teleconference betweens users, carsharing, online information on public transports User Behaviour Change: SAVE ENERGY project Involve the building’s users and promote a dissemination campaign on good practices, influencing their energy consumption pattern;
    7. MUNICIPALITY’S MAIN OFFICE BUILDING: CAMPO GRANDE 25 MUNICIPALITY’S MAIN OFFICE BUILDING: CAMPO GRANDE 25 THE SAVE ENERGY PILOT AREA The SAVE ENERGY project will focus on two of the building areas: Block 1 B – Intervention and monitoring Administrative services 52 working technicians 478 sqm Block 2 B – Monitoring and control Administrative services 64 working technicians 550 sqm
    8. MUNICIPALITY’S MAIN OFFICE BUILDING: CAMPO GRANDE 25 MUNICIPALITY’S MAIN OFFICE BUILDING: CAMPO GRANDE 25 THE SAVE ENERGY PROJECT TASKS IN LISBON Tasks Explanation T-1 Definition of Pilot T-2 Energy Audit T-3 Technical Solution Design T-4 Identification of Equipment T-5 Equipment Installation & Mtg T-6 Central Data Collection T-7 Pilot Testing T-8 Pilot Implementation T-9 User Engagement Strategy T-10 Training and Documentation
    9. MUNICIPALITY’S MAIN OFFICE BUILDING: CAMPO GRANDE 25 MUNICIPALITY’S MAIN OFFICE BUILDING: CAMPO GRANDE 25 THE SAVE ENERGY PROJECT TASKS IN LISBON Task 1 Definition of Pilot Areas Focus in the Municipality 1st floor, section B, active promotion of users behaviour change. Municipality 2nd floor, section B, will also be monitored for control. Task 2 Energy Audit -The current Municipality energy information is for the whole building only, performed with 2007 data, 50kWh/sqm; -There is the ability to provide a breakdown assessment to the energy consumption of different blocs within each floor. This assessment will be made during the first two months of the monitoring equipment implementation. -The acclimatization and elevators systems are centralized. No breakdown is possible for the areas under analysis.
    10. MUNICIPALITY’S MAIN OFFICE BUILDING: CAMPO GRANDE 25 MUNICIPALITY’S MAIN OFFICE BUILDING: CAMPO GRANDE 25 THE SAVE ENERGY PROJECT TASKS IN LISBON Application Role of Users Problem Technical Solution Schedule: 7:00h to 20:00h Lighting, 8W/sqm, Operation and Manual Control Lack of adequacy to natural 500 lux Control Installation of photo sensor light Reduce the unnecessary use 1 PC per user Manual control of Unnecessary use of power power, interactive contact by (345W/unit) power supply consumes displays (turn it off) 1 PC screen per Manual control of Interactive communication with the Unnecessary use of power user (70W/unit) power supply users: off during lunch Interactive communication with the Operation and Printers (3 in 1B) Schedule: always on users: Last user turn every Control equipment off! Interactive communication with the Operation and Coffee-machines Schedule: always on users: Last user turn every Control equipment off! Users Equipments On when full charge and Operation and Interactive communication with the like without any cell phone Control users: turn the equipment off! mobile chargers connected
    11. MUNICIPALITY’S MAIN OFFICE BUILDING: CAMPO GRANDE 25 MUNICIPALITY’S MAIN OFFICE BUILDING: CAMPO GRANDE 25 THE SAVE ENERGY PROJECT TASKS IN LISBON Task 3 Technical Solution Design - ISA is responsible for setting Lisbon’s project solution; - The monitoring equipments were already identified and presented to the Municipality; - First check of compliance with the existing conditions for monitoring in the selected areas; - Final monitoring architecture solution is being prepared and should be validated in the field. The communication/interaction model with the users needs to be precisely defined. Public display meters with online data and individual contact. Task 4 Identification of Equipment - ISA presented some of it’s equipments: iPlugMeter; iMeterRail; iPoint; iDisplayMeter How will the Nokia Home Control Unit be included?
    12. MUNICIPALITY’S MAIN OFFICE BUILDING: CAMPO GRANDE 25 MUNICIPALITY’S MAIN OFFICE BUILDING: CAMPO GRANDE 25 THE SAVE ENERGY PROJECT TASKS IN LISBON Task 3 Technical Solution Design – Sensor Architecture Implementation
    13. MUNICIPALITY’S MAIN OFFICE BUILDING: CAMPO GRANDE 25 MUNICIPALITY’S MAIN OFFICE BUILDING: CAMPO GRANDE 25 THE SAVE ENERGY PROJECT TASKS IN LISBON Task 3 Technical Solution Design – Middleware architecture platform
    14. MUNICIPALITY’S MAIN OFFICE BUILDING: CAMPO GRANDE 25 MUNICIPALITY’S MAIN OFFICE BUILDING: CAMPO GRANDE 25 THE SAVE ENERGY PROJECT TASKS IN LISBON Task 3 Technical Solution Design – Blue Prints Implementation
    15. MUNICIPALITY’S MAIN OFFICE BUILDING: CAMPO GRANDE 25 MUNICIPALITY’S MAIN OFFICE BUILDING: CAMPO GRANDE 25 THE SAVE ENERGY PROJECT TASKS IN LISBON Task 5 Equipment Installation and Management ISA is responsible for the installation and management of the system. Task 6 Central Data Collection Utilise wireless network within the building for data transfer to the central project server and for the building display. Task 7 Pilot Testing Ensure full functionality and delivery of project objectives prior to full implementation of “live” system. Two periods for data collection: a first period for baseline assessment in both areas, project presentation to the users and afterwards the period of active interaction (1st floor, block B) and monitoring ( 2nd floor, block B).
    16. MUNICIPALITY’S MAIN OFFICE BUILDING: CAMPO GRANDE 25 MUNICIPALITY’S MAIN OFFICE BUILDING: CAMPO GRANDE 25 THE SAVE ENERGY PROJECT TASKS IN LISBON Task 8 Pilot Implementation Full implementation of Lisbon Pilot – until 31st August 2010 (M18) Task 9 User Engagement Strategies Lisbon Municipality staff – identify a focus group, voluntary group that commits to the Save Energy objectives and acts dynamically, promoting their and other users behaviour change. Municipality staff in the 2nd floor, block B – monitoring control area. Strategy for user engagement – strategy/incentives for user participation and motivation: focus group, workshops, active dissemination Task 10 Training and Documentation Documentation on the SAVE ENERGY objectives and the opportunities for energy consumption reduction through behaviour change.
    17. MUNICIPALITY’S MAIN OFFICE BUILDING: CAMPO GRANDE 25 MUNICIPALITY’S MAIN OFFICE BUILDING: CAMPO GRANDE 25 THE SAVE ENERGY COMMUNICATION STRATEGY Local Data Visualization
    18. MUNICIPALITY’S MAIN OFFICE BUILDING: CAMPO GRANDE 25 MUNICIPALITY’S MAIN OFFICE BUILDING: CAMPO GRANDE 25 THE SAVE ENERGY COMMUNICATION STRATEGY GOING TO LUNCH!! TURN YOUR MONITOR OFF At the end of the year, it will represent: - 20kWh avoided consumption; - 2,5 € of economy and; - 10 kg of CO2; - 100€ of economy in 1B!
    19. MUNICIPALITY’S MAIN OFFICE BUILDING: CAMPO GRANDE 25 MUNICIPALITY’S MAIN OFFICE BUILDING: CAMPO GRANDE 25 THE SAVE ENERGY COMMUNICATION STRATEGY ENOUGH FOR TODAY!! TURN YOUR COMPUTER OFF At the end of the year, it will represent: - 1MWh avoided consumption; - 150€ of economy and; - 2600kg of CO2
    20. MUNICIPALITY’S MAIN OFFICE BUILDING: CAMPO GRANDE 25 MUNICIPALITY’S MAIN OFFICE BUILDING: CAMPO GRANDE 25 THE SAVE ENERGY PROJECT TASKS IN LISBON Year 1 Year 2 Year 3 Months 1 - 12 Months 13 - 18 Months 19-30 2009 2010 2011 0 03 04 05 06 08 09 10 11 12 01 02 03 04 05 06 07 08 09 10 11 12 01 02 03 04 05 06 07 08 7 T-1 T-2 T-3 T-4 T-5 T-6 T-7 T-8 T-9 T-10

    + DenisDenis, 5 months ago

    custom

    216 views, 0 favs, 0 embeds more stats

    Presentation delivered at SAVE ENERGY project meeti more

    More info about this document

    © All Rights Reserved

    Go to text version

    • Total Views 216
      • 216 on SlideShare
      • 0 from embeds
    • Comments 0
    • Favorites 0
    • Downloads 7
    Most viewed embeds

    more

    All embeds

    less

    Flagged as inappropriate Flag as inappropriate
    Flag as inappropriate

    Select your reason for flagging this presentation as inappropriate. If needed, use the feedback form to let us know more details.

    Cancel
    File a copyright complaint
    Having problems? Go to our helpdesk?

    Groups / Events