Double Duct Heat Pumps 2012

863 views

Published on

Our double duct heat pumps are ideal for modular or prefab buildings. In addition the uniqueness of our product lends itself to temporary buildings. Finally our virtual plug and play concept will provide much needed cooling or heating to those with cabins or cottages. Please take a moment to view the attached pdf file for more information.

Published in: Business, Technology
0 Comments
0 Likes
Statistics
Notes
  • Be the first to comment

  • Be the first to like this

No Downloads
Views
Total views
863
On SlideShare
0
From Embeds
0
Number of Embeds
1
Actions
Shares
0
Downloads
6
Comments
0
Likes
0
Embeds 0
No embeds

No notes for slide

Double Duct Heat Pumps 2012

  1. 1. Sonkor International Sales Presentation: DD Monobloc (1) High Efficiency Single Chassis “Monobloc” Heat Pump A unique solution Provides cooling and heating for :  Mobile Homes/Cottages/Cabins  Residential Containers/Pre Fabrication Units  Portable/Temporary Offices Ambient-Operating range between - 4F (-20°C) to + 125.6F (+ 52°C)1
  2. 2. Sonkor International Sales Presentation: DD Monobloc (1) Application Product Solution Mobile/Pre Fabricated Units Product Range Superior to Window and Splits The special lightweight construction The full range of Sonkor heat pumps Our cylinder block heat pump was of mobile homes and residential adapts well to extreme conditions uniquely designed for this type of prefabs provide good insulation in from the bitter cold of northern application and offers many winter but not in summer. Unit countries to dry or damp heat advantages over window, package placement is sometimes unclear locations such as in Africa, Asia, or traditional split systems, including until the actual time of sale, which India, USA, Latin America. ease of installation and unique could mean a variety of temperature performance . and humidity ranges.2
  3. 3. Sonkor International Applications Sales Presentation: DD Monobloc (1) Mobile Homes/Cabins Container Housing Temporary Offices Cottages/Cabins/Pre Fabs Day and Night: Simple Comfort Strong Thermal Loads Special attention was devoted to the Used on job sites or even small office These applications have high thermal acoustic insulation of heat pumps buildings - in either case you will need loads especially in summer conditions. allowing the units to be installed in any powerful machines to meet the ever- Adding to the external loads are items room configuration: living room, bedroom, changing thermal loads. Our product such as computers, lamps and heat guest rooms, etc. range provides a solution for these needs generated from people. Thanks to the with the utmost respect of environmental special fresh air intake feature our heat and acoustic comfort. pumps ensures optimum comfort whilst also providing a high level of air quality and low concentrations of C02.3
  4. 4. Sonkor International No Outdoor Unit Required Sales Presentation: DD Monobloc (1) Products and Solutions High wall - iCool and iWarm Product Range There are four product configurations including an EC motor option de- signed to improve energy efficiency and increase the COP and EER of the units. An additional option is the possibility to add 1600 watts of back up heat. The unit will work up to minus 4 degrees Fahrenheit (minus 20 de- grees Centigrade). Our sleek design measures only 7.7 inches (19.5 centi- meters) in depth and includes activated carbon filters. Low wall - PTTW Product Range The low wall product range also consists of four models configured with AC or EC motors. One of the versions is equipped with 2000 watts of back up heat, which allows for continuous operation of the unit up to - 4F (-20°C). Hot gas bypass, on board controls, and an indoor air exchange system are just a few of the many features. Extremely compact measuring only 9.45 inches (24 centimeters) in depth. This is a very attractive design with many options.4
  5. 5. Sonkor International Benefits Sales Presentation: DD Monobloc (1) Simplified Installation Ultra Quiet Ecological Two Tubes Ultra Quiet Ecology and low energy consumption Installation is easy requiring only two Our use of Expanded Polypropylene The use of high efficiency motors and holes on the outside wall. (EPP) and insulating fibers provide levels compressors help obtain the minimum of soundproofing impossible with COP and EER levels to comply with the In installations where outside tempera- traditional window or package type units. European Energy labeling Directive 2013 tures reach below 32°F (0°C), we recom- and 2014 and in North America the DOE/ mend the installer connect the condensate The units offer a comfortable low noise AHRI standards 210/240-2008 (Window outlet for heat pump operation. level at the top of it’s class. units) 310/380-2004 (PTAC) . Additionally, the possibililty of theft or tampering is greatly reduced since the unit is located 100% on the inside of the building.5
  6. 6. Sonkor International Benefits Sales Presentation: DD Monobloc (1) Low Wall Mount High Wall Mount CO2 Minimized Low Wall Range High Wall Range Fresh Air Exchange Our floor range is aesthetic to the eye and For those preferring a high wall unit our The presence of fresh air exchange in competes quite favorably against tradition- unique design appears to be as a tradi- both product platforms guarantees a con- al compact fan coils. tional split unit but has all the advantage stant fresh air intake rate of 30-40 m3/h. of being self contained on the inside of the This is particularly useful in bedrooms or Attractive in design with on board controls. building. The lower flap and adjustable au- offices, where the CO2 levels tend to in- to louver are designed to distribute opti- crease with the presence of people. This mally the air in the surrounding environ- is a plus not found in traditional split type ment. units.6
  7. 7. Sonkor International Additional Benefits Sales Presentation: DD Monobloc (1) -4F (–20°C) Outdoor +125.6F (+52°C) Outdoor On Board Controls Low and High Wall Units T3 - Tropicalized Performance Practicality Air-to-air heat pumps, such as split, Our rigorous testing helps ensure smooth In addition to offering remote controls the window, and package units have problems operation and minimal reduction in units have on board controls for ease of of not providing the necessary thermal performance of the units even in extreme use. Both low and high wall units come power when the outside temperature tropical conditions: with infrared hand held remote con- drops below 32 degrees F (0 degrees C). trols. 90F (32°C) indoor temperature Our range ensures maximum comfort even in these extreme conditions, 125.6F (52°C) outdoor temperature reducing the dependency of defrost cycling through the use of a hot gas This is made possible through the bypass system. generous heat exchangers and air flow.7
  8. 8. Sonkor International Additional Benefits Sales Presentation: DD Monobloc (1) Certifications 3D air diffusion Lower Total Costs TUV CE - ETL - RoHS High Wall Project Savings Our entire product range is TUV Our unique three-dimensional air distribu- Low installation and maintenance costs Rheinland or ETL certified. This allows us tion system allows the unit to reach set plus lower risk of refrigerant leaks when to provide maximum electrical safety and point quickly. This unique feature is not compared to split units, are just some of reduction of claims. available in conventional window, split, the strengths of our innovative product so- package type air conditioners. lution. Additional certifications include CE mark + RoHS and EMC. Our heat pumps are ideal for manufactur- ers of mobile homes and container housing. In the end we provide a winning solution in terms of total cost.8
  9. 9. Sonkor International High Wall From 32F (0°C) to 125.6F (52°C) External Sales Presentation: DD Monobloc (1) iCool ECM MODEL iCool High Efficiency Total cooling capacity kW 2.01 2.01 Heating capacity kW 2.01 2.01 Electric heat booster kW - - Power input W 837 770 EER rating (Class) W/W 2.49 (B) 2.71 (A) COP rating (Class) W/W 2.90 (B) 3.20 (A) Performance Certification Own lab Own lab Air volume CMH 390 390 Fan speed 3+Auto 3+Auto Dehumidification l/h 0.7 1.0 Indoor sound pressure level @ 1 metre dB(A) 42/46/49 42/46/49 Outdoor sound pressure level @ 1 metre dB(A) 50/56/60 50/56/60 Serial BUS communication (protocol) Standard (MODBUS) Standard (MODBUS) Electrical supply V/ph/Hz 230/1/50 230/1/50 Refrigerant R410a R410a Dimensions - Width mm 950 950 Dimensions - Height mm 430 430 Dimensions - Depth Mm 195 195 Net weight kg 38 39 Wall hole diameter mm 200 200 Certification TUV CE/RoHS/ETL TUV CE/RoHS/ETL9
  10. 10. Sonkor International High Wall From 32F (0°C) to 125.6F (52°C) External Sales Presentation: DD Monobloc (1) iWarm ECM MODEL iWarm High Efficiency Total cooling capacity kW 2.01 2.01 Heating capacity (incl. electric heat) kW 2.01 (3.61) 2.01 (3.61) Electric heat booster kW 1.6 1.6 Power input (electric heat) W 837 (1,600) 770 (1,600) EER rating (Class) W/W 2.49 (B) 2.71 (A) COP rating (Class) W/W 2.90 (B) 3.20 (A) Performance Certification Own lab Own lab Air volume CMH 390 390 Fan speed 3+Auto 3+Auto Dehumidification l/h 0.7 1.0 Indoor sound pressure level @ 1 metre dB(A) 42/46/49 42/46/49 Outdoor sound pressure level @ 1 metre dB(A) 50/56/60 50/56/60 Serial BUS communication (protocol) Standard (MODBUS) Standard (MODBUS) Electrical supply V/ph/Hz 230/1/50 230/1/50 Refrigerant R410a R410a Dimensions - Width mm 1010 1010 Dimensions - Height mm 430 430 Dimensions - Depth mm 195 195 Net weight kg 38 39 Wall hole diameter mm 200 200 Certification TUV CE/RoHS/ETL TUV CE/RoHS/ETL10
  11. 11. Sonkor International Low Wall From 25F (–4°C) to 125.6F (52°C) External Sales Presentation: DD Monobloc (1) MODEL PTTW-09 PTTW-12 Total cooling capacity kW 2.46 3.25 Heating capacity (incl. electric heat) kW 2.78 3.33 (3.83) Electric heat booster kW - 500 Power input (electric heat) W 980 1370 (500) EER rating (Class) W/W 2.53 (B) 2.43 (B) COP rating (Class) W/W 2.83 (B) 2.60 (C) Performance Certification Own lab Own lab Air volume CMH 400 480 Fan speed 3+Auto 3+Auto Dehumidification l/h 0.8 1.1 Indoor sound pressure level @ 1m dB(A) 37/40/46 37/44/48 Outdoor sound pressure level @ 1m dB(A) 43 41/52 Serial BUS communication (protocol) Optional (MODBUS) Standard (MODBUS) Electrical supply V/ph/Hz 230/1/50 230/1/50 Refrigerant R410a R410a Dimensions - Width mm 1000 1000 Dimensions - Height mm 580 580 Dimensions - Depth mm 230 245 Net weight kg 40 42 Wall hole diameter mm 162 162 Certification TUV CE / RoHS / ETL TUV CE / RoHS / ETL11
  12. 12. Sonkor International Low Wall From 25F (–4°C) to 125.6F (52°C) External Sales Presentation: DD Monobloc (1) PTTW-10-ECM PTTW-10-ECM-EH MODEL High Efficiency High Efficiency Total cooling capacity kW 2.90 2.90 Heating capacity (incl. electric heat) kW 2.96 2.96 (4.96) Electric heat booster kW - 2.00 Power input (electric heat) W 905 905(2000) EER rating (Class) W/W 3.27 (A++) 3.27 (A++) COP rating (Class) W/W 3.51 (A++) 3,51 (A++) Performance Certification SGS Institute SGS Institute Air volume CMH 450 450 Fan speed 3+Auto 3+Auto Dehumidification l/h 1.0 1.0 Indoor sound pressure level @ 1m dB(A) 37/44/48 37/44/48 Outdoor sound pressure level @ 1m dB(A) 41/52 41/52 Serial BUS communication (protocol) Standard (MODBUS) Standard (MODBUS) Electrical supply V/ph/Hz 220/1/60 220/1/60 230/1/50 230/1/50 Refrigerant R410a R410a Dimensions - Width mm 1000 1000 Dimensions - Height mm 580 580 Dimensions - Depth mm 245 245 Net weight kg 42 42 Wall hole diameter mm 162 mm 162 mm Certification TUV CE / RoHS / ETL TUV CE / RoHS / ETL12

×