Esterilização e desinfecção
Upcoming SlideShare
Loading in...5
×
 

Like this? Share it with your network

Share

Esterilização e desinfecção

on

  • 11,634 views

 

Statistics

Views

Total Views
11,634
Views on SlideShare
11,631
Embed Views
3

Actions

Likes
0
Downloads
170
Comments
0

1 Embed 3

http://www.dapab.com.br 3

Accessibility

Upload Details

Uploaded via as Adobe PDF

Usage Rights

© All Rights Reserved

Report content

Flagged as inappropriate Flag as inappropriate
Flag as inappropriate

Select your reason for flagging this presentation as inappropriate.

Cancel
  • Full Name Full Name Comment goes here.
    Are you sure you want to
    Your message goes here
    Processing…
Post Comment
Edit your comment

Esterilização e desinfecção Presentation Transcript

  • 1. CONTROLE DE MICRORGANISMOS ESTERILIZAÇÃO E DESINFECÇÃO WALDEREZ GAMBALE ICBUSP FMJ
  • 2. HISTÓRICO ARISTÓTELES KOCH E PASTEUR-MICRORGANISMOS APLICAÇÃO MAIS VARIADOS CAMPOS – ALIMENTOS – INDUSTRIAS – HOSPITAIS – ÁREAS LIMPAS
  • 3. CONCEITOS ESTERILIZAÇÃO DESINFECÇÃO ESTERILIZANTE DESINFETANTE ANTISSÉPTICO GERMICIDA GERMISTÁTICO ASSEPSIA-TÉCNICAS ASSÉPTICAS
  • 4. CONTROLEMÉTODOS QUÍMICOS DESINFECÇÃO
  • 5. ANTI-SÉPTICOS E DESINFETANTES ELIMINAR (IDEALMENTE) MINIMIZAR RISCO DE ADQUIRIR INFECÇÕES
  • 6. CARACTERÍSTICAS DE UM BOM DESINFETANTE AMPLO ESPECTRO EMPREGO EM BAIXAS CONCENTRAÇÕES SOLUBILIDADE EM ÁGUA ESTABILIDADE INOCUIDADE PARA HOMEM E ANIMAIS TOXICIDADE PARA MICRORGANISMOS PODER DE PENETRAÇÃO NÃO SER CORROSIVO OU TINTORIAL HOMOGENEIDADE SEM CHEIRO OU CHEIRO AGRADÁVEL BARATO
  • 7. CLASSIFICAÇÃO DOS DESINFETANTES NÍVEL DE DESINFECÇÃO DESEJADO – ALTO- HOSPITALARES – INTERMEDIÁRIO – DOMICILIARES – BAIXO- DOMICILIARES
  • 8. NÍVEIS DE ATIVIDADE DESINFETANTEALTO BACTERIAS ESPORULADAS Bacillus ClostridiumINTERMEDIARIO MICOBACTERIAS Mycobacterium PEQUENOS VÍRUS-N LIP Poliovírus Coxsackie Rhinovirus FUNGOSBAIXO BACTERIAS VEGETATIVAS Pseudomonas Staphylococcus Salmonella VÍRUS MÉDIOS- LIP Herpes simplex Citomegalovirus VSR-Hep B-HIV
  • 9. CLASSIFICAÇÃO DOS DESINFETANTES COMPOSIÇÃO QUÍMICA ÁLCOOIS: ETÍLICO E ISOPROPÍLICO ALDEIDOS: FÓRMICO E GLUTARALDEIDO FENÓIS: CRESOL, TIMOL, TRICLOSAN HALOGENIOS: HIPOCLORITOS, IODO CATIÔNICOS E ANIÔNICOS: CLOROHEXIDINE AGENTES OXIDANTES: H2O2, PERMANG.DE k METAIS PESADOS: PRATA E COBRE
  • 10. MECANISMO DE AÇÃO ALTERAÇÕES NA MEMBRANA DESNATURAÇÃO DE PROTEINAS OXIDAÇÃO PH
  • 11. FATORES INTERFERENTES CONCENTRAÇÃO TEMPO PH TEMPERATURA SUBSTÂNCIAS ESTRANHAS – MUCO, SALIVA, SANGUE, FEZES, ETC
  • 12. CONTROLE-MÉTODOS FÍSICOS ESTERILIZAÇÃOCALOR SECO FLAMBAGEM BICO DE BUNSEN AR QUENTE FORNO PASTEUR ÚMIDO < 100OC PASTEURIZAÇÃO 100OC ÁGUA FERVENTE TINDALIZAÇÃO > 100OC AUTOCLAVEFILTRAÇÃO VELAS MEMBRANAS FILTRANTES FILTROS HEPADESSECAÇÃORADIAÇÕES IONIZANTES Y-X NÃO IONIZANTES UV
  • 13. CALOR SECO BICO DE BUNSEN INCINERADORES FORNO PASTEUR
  • 14. BICO DE BUNSEN
  • 15. CALOR ÚMIDO ABAIXO DE 100 0C – PASTEURIZAÇÃO 100 0C – ÁGUA FERVENTE – VAPOR FLUENTE-TINDALIZAÇÃO ACIMA DE 100 0C – AUTOCLAVE
  • 16. PASTEURIZAÇÃOCALOR ABAIXO DE 100 0C 60 0C 30 MINUTOS 71,7 0C 15 SEGUNDOS ESFRIAMENTO RÁPIDO DESTROI PATOGÊNICOS NÃO DESTROI ESPORULADOS
  • 17. ÁGUA FERVENTE CALOR A 1000CTEMPERATURA DE EBULIÇÃO-ALTITUDE1021009896949290888684 0 600 1200 1800 2400 3000
  • 18. AUTOCLAVE-CALOR ACIMA DE 1000C TEMPERATURA DO VAPOR D’ÁGUA SOB PRESSÃOPressão d’água Temperatura (lb/pol2) 0 100 5 109 10 115 15 121,5 20 126,5
  • 19. AUTOCLAVE
  • 20. RESISTÊNCIA NATURALBactérias Mínima Ótima MáximaPsicrófilas 0oC 10-20 25Mesófilas 5-25 37 43Termófilas 22-45 50-55 60-90 Fungos -290 100
  • 21. TEMPO DE DESTRUIÇÃO DE ESPOROS CALOR ÚMIDO CALOR SECO TEMP. MORTE-MIN TEMP MORTE-MINB.anthracis 100 2-15 140 >180 105 5-10 180 3C.botulinum 100 300-530 120 50 110 32-90 130 15-35 115 10-40 140 5C. Perfringens 100 5-45 120 50 105 5-27 140 5 120 1C. Tetani 100 5-90 130 20-40 105 5-25 140 5-15 120 1 160 12
  • 22. CONTROLE DE ESTERILIDADE BACTÉRIAS ESPORULADAS BACILLUS ATHROPHAEUS GEOBACILLUS STEARATERMOPHILLUS
  • 23. FILTRAÇÃO VELAS – CHAMBERLAND – BERKEFELD MEMBRANAS FILTRANTES – CELULOSE- MILLIPORE – AMIANTO- SEITZ FILTROS HEPA
  • 24. FILTRO MILLIPORE
  • 25. FILTRAÇÃO
  • 26. FLUXO LAMINAR FILTROS HEPA
  • 27. DESSECAÇÃO DESIDRATAÇÃO LIOFILIZAÇÃO ALTAS CONCENTRAÇÕES – AÇUCAR – SAL
  • 28. RADIAÇÕES IONIZANTES – RAIOS GAMA NÃO IONIZANTES – LUZ UV
  • 29. LUZ ULTRAVIOLETA
  • 30. MÉTODOS DE ESTERILIZAÇÃOMÉTODO CONCENTRAÇÃO OU NÍVELVAPOR SOB PRESSÃO 121 0C- VÁRIOS TEMPOSCALOR SECO 1H 171 0CFILTRAÇÃO 0,22 um PORO; FILTRO HEPAULTRAVIOLETA 254 nm-EXPOSIÇÃO VARIÁVELIONIZANTE MICROONDAS OU GAMAÓXIDO DE ETILENO 450-1200 mg/L-29-65 0C-2-5HVAPOR DE FORMALDEIDO 2%-5% A 60-80 0CVAPOR PERÓXIDO 30% A 55% ATÉ 60 0CHIDROGÊNIOGÁS DE PLASMA GÁS PER. HIDROG IONIZADOÁC. PERACÉTICO 0,2%GLUTARALDEIDO 2%
  • 31. MÉTODOS DE DESINFECÇÃOMÉTODO CONCENTRAÇÃO (NÍVEL)CALOR ÚMIDO 75-100 0C-30 MIN- (ALTO)GLUTARALDEIDO 2% (ALTO)PERÓXIDO DE HIDROGÊNIO 3-25% (ALTO)FORMALDEIDO 3-8% (ALTO/INTERM)DIÓXIDO DE CLORO VARIÁVEL (ALTO)ÁCIDO PERACÉTICO VARIÁVEL (ALTO)COMPOSTOS DE CLORO 100-1.000 ppm C livre (ALTO)ÁLCOOL (ETÍLICO, ISOPROPÍLICO) 70%-95% (INTERM)COMPOSTOS FENÓLICOS 0,4-5,0% (INTERM/BAIXO)COMPOSTOS IODÓFOROS 30-50 ppm I livre (INTERM)QUATERNÁRIOS DE AMÔNIA 0,4-1,6% (BAIXO)
  • 32. AGENTES ANTI-SÉPTICOSAGENTE CONCENTRAÇÃOÁLCOOL (ETÍL- ISOPROPÍLICO) 70%-90%IODÓFOROS 1-2 mg I LIVRE/LCLORHEXIDINA 0,5-4%TRICLOSAN 0,3-2,0%
  • 33. MATERIAIS, INSTRUMENTOS, EQUIPAMENTOS ESTERILIZAÇÃO OU DESINFECÇÃO MÉTODOS FÍSICOS OU QUÍMICOS CRÍTICOS-ESTERILIZAÇÃO – CONTATO COM TECIDOS, SANGUE, ÁREAS ESTÉREIS – BISTURI, AFASTADORES, SUTURAS, TESOURAS, AGULHAS E OUTROS USADOS EM CIRURGIAS SEMI-CRÍTICOS-DESINFECÇÃO – CONTATO COM MUCOSAS ÍNTEGRAS – EQUIPAMENTOS RESPIRATÓRIOS, ENDOSCÓPIOS, CATÉTERES URINARIOS, EQUIPAMENTOS EXAME GARGANTA, TERMÔMETROS NÃO-CRÍTICOS – DEMAIS