Your SlideShare is downloading. ×
0
Dymeter Catalog
Dymeter Catalog
Dymeter Catalog
Dymeter Catalog
Dymeter Catalog
Dymeter Catalog
Dymeter Catalog
Dymeter Catalog
Dymeter Catalog
Dymeter Catalog
Dymeter Catalog
Dymeter Catalog
Dymeter Catalog
Dymeter Catalog
Dymeter Catalog
Dymeter Catalog
Dymeter Catalog
Dymeter Catalog
Dymeter Catalog
Dymeter Catalog
Dymeter Catalog
Dymeter Catalog
Upcoming SlideShare
Loading in...5
×

Thanks for flagging this SlideShare!

Oops! An error has occurred.

×
Saving this for later? Get the SlideShare app to save on your phone or tablet. Read anywhere, anytime – even offline.
Text the download link to your phone
Standard text messaging rates apply

Dymeter Catalog

560

Published on

Water Quality Measuring System, Chloride Meter, Digital Salt Tester

Water Quality Measuring System, Chloride Meter, Digital Salt Tester

0 Comments
0 Likes
Statistics
Notes
  • Be the first to comment

  • Be the first to like this

No Downloads
Views
Total Views
560
On Slideshare
0
From Embeds
0
Number of Embeds
0
Actions
Shares
0
Downloads
3
Comments
0
Likes
0
Embeds 0
No embeds

Report content
Flagged as inappropriate Flag as inappropriate
Flag as inappropriate

Select your reason for flagging this presentation as inappropriate.

Cancel
No notes for slide

Transcript

  • 1. Water Quality Measuring On-line System#207 Ace techno tower(Ⅱ), 197-7, Guro-3dong, Guro-gu,Seoul, Korea (152-766)TEL : 82-2-858-6870 FAX : 82-2-866-9422E-mail : chloride@kita.net http://chloride.en.ecplaza.net
  • 2. Table of Contents About us Water Quality Measuring On-line System pH Analyzer ………………………………………………………………………………………… 1 ORP Analyzer ……………………………………………………………………………………… 3 Dissolved Oxygen Analyzer ……………………………………………………………………… 5 Conductivity Analyzer …………………………………………………………………………… 7 Residual Chlorine Analyzer ……………………………………………………………………… 9 Mixed Liquor Suspended Solids Analyzer ………………………………………………… 11 Suspended Solids Analyzer …………………………………………………………………… 13 Turbidity Analyzer ……………………………………………………………………………… 15 Installation Site (Outdoor / Indoor)…………………………………………………………… 17 Basic Selection Table Guide ………………………………………………………………… 18 Portable Multi Parameter ……………………………………………………………………… 19 On-line Multi Parameter ……………………………………………………………………… 20 Mounting Example ……………………………………………………………………………… 21 Installation Example …………………………………………………………………………… 22 Digital Pocket Tester Conductivity Pocket Tester …………………………………………………………………… 25 pH Pocket Tester ……………………………………………………………………………… 26 ORP Pocket Tester …………………………………………………………………………… 27 Malaysia SiteDear Sir/Madam, Home & Industrial Measurement Digital Salt Tester ……………………………………………………………………………… 28Good day to you!!! Digital Hygro Thermometer …………………………………………………………………… 29 Digital Thermometer …………………………………………………………………………… 30O ur company was founded in 1982 and is specialized in electrochemical sensors and industrial measuring instruments. We aim to maximize our company value throughwide experience and the management for customer satisfaction as a leader in the field. Mini Digital Salt Checker ……………………………………………………………………… 31Our company is producing high quality products through strict inspection. Aquariums & Pets Supply Digital Marine Tester …………………………………………………………………………… 32 We feel you maybe interested in our products and would like to briefly introduce them asfollows:Please see attached our Product Lines. Measuring & Testing EquipmentThanks a lot. Portable Chloride Meter for Fresh Concrete ……………………………………………… 33 Digital Air Meter ………………………………………………………………………………… 34 Portable Chloride Meter for Hardened Concrete ………………………………………… 35 Certificates Certificates ……………………………………………………………………………………… 36
  • 3. DWA-3000A/3000B/2000A pH Analyzer pH Electrode Model PP34 / PW34 Model PP13F / PW31F Pure water, Clean water (PP34) Application Pure water, Clean water (PP13F) Wastewater, Sewage, General (PW34) Application Wastewater, Sewage, General (PW31F) 2 ~ 12 pH (PP34) Range Range 0 ~ 14 pH 0 ~ 14 pH (PW34) 0 ~ 80 C (PP13F) ˚ 0 ~ 80 C (PP34) ˚ Temp. Range Temp. Range 0 ~ 110 C (PW31F) ˚ 0 ~ 110 C (PW34) ˚ Water Quality Measuring On-line System Temp. Sensor PT1000/Order Temp. Sensor PT1000/Order Pressure Max. 0.6Mpa Pressure Max. 0.6Mpa Body Material Glass Body Material PPS Cable Fixed cable Cable Fixed cable Thread PG13.5 Thread 3/4" NPT Holder Submersion/Flow-through Holder Submersion/Flow-through Model P1 Model P20 / P21 / P30 Features Application General Application General Range 0 ~ 14 pH Range 0 ~ 14 pH Real Time Trend Analysis Function Temp. Range 0 ~ 80 C ˚ Temp. Range 0 ~ 80 C ˚ Microprocessor-based Digital Program Controller None (P20,P21) Temp. Sensor None Temp. Sensor Isolated DC (4-20/0-20/0-24mA) Output Transmission PT1000/Order (P30) Automatic Cleaning Control Function Pressure Max. 0.3Mpa Pressure Max. 0.3Mpa Low-cost For User Satisfaction Body Material Glass Body Material PC CE Mark Accredited Cable Plug-In Cable Fixed cable Thread PG13.5 Thread None Holder Submersion/Flow-through Holder Submersion/Flow-through pH System Configuration (3000A) NO. MODEL MATL 1 POWER CABLE 2.0SQ×3C FR-CVV 2 CLEANER CABLE 1.25SQ×2C FR-CVV 3 ANALOG CABLE 1.25SQ×2C FR-CVVSB 4 DIGITAL CABLE 4C×20#AWG SHIELD 5 AIR HOSE ф5 6 SOLVALVE 1/4〞PT AIR ONLY Specification Range 0~14 pH (Resolution : 0.01) Method Combination glass electrode Accuracy ±0.02 pH (Of Full Scale) Response time 30 sec (90% saturation) Analog output Isolated 4~20mA DC (STD) / 0~20mA, 0~24mA(OPT) Digital output 3000A : RS-232C (STD), RS-485 (OPT) / 3000B : RS-232C / 2000A : N/A Relay output 3000A : HH, H, L, LL & Cleaning / 3000B, 2000A : High, Low & Cleaning IP Rating IP65 / IP64 / IP54 Display Trend graph, Measuring value, Measuring status, Temperature, Unit Size 240 x 180 x 115mm / 155 x 155 x 184mm / 96 x 96 x 125mm Installation Wall mounting / DIN 144 panel mounting / DIN 96 panel mounting Power 110 / 220V, 50 / 60Hz1 2
  • 4. DWA-3000A/3000B/2000A ORP Analyzer ORP Electrode Model R01 Model R11 Application Wastewater, Sewage Application Wastewater, Sewage Range ±1,500 mV Range ±1,500 mV Temp. Range 0 ~ 110 C ˚ Temp. Range 0 ~ 110 C ˚ Temp. Sensor None Temp. Sensor None Water Quality Measuring On-line System Pressure Max. 0.6Mpa Pressure Max. 0.6Mpa Body Material PPS Body Material Glass Cable Fixed cable Cable Fixed cable Thread 3/4" NPT Thread PG13.5 Holder Submersion/Flow through Holder Submersion/Flow through Model R28 Features Application General Range ±1,500 mV Real Time Trend Analysis Function Temp. Range 0 ~ 80 C ˚ Microprocessor-based Digital Program Controller Isolated DC (4-20/0-20/0-24mA) Output Transmission Temp. Sensor None Automatic Cleaning Control Function Pressure Max. 0.3Mpa Low-cost For User Satisfaction Body Material PC CE Mark Accredited Cable Fixed cable Thread None Holder Submersion/Flow through ORP System Configuration (3000B) NO. MODEL MATL 1 POWER CABLE 2.0SQ×3C FR-CVV 2 CLEANER CABLE 1.25SQ×2C FR-CVV 3 ANALOG CABLE 1.25SQ×2C FR-CVVSB 4 DIGITAL CABLE 4C×20#AWG SHIELD 5 AIR HOSE ф6 6 SOLVALVE 1/4 PT 〞 AIR ONLY Specification Range ±1,500 mV (Resolution : 1) Method Combination Pt electrode Accuracy ±1 mV Response time 60 sec (90% saturation) Analog output Isolated 4~20mA DC (STD) / 0~20mA, 0~24mA(OPT) Digital output 3000A : RS-232C (STD), RS-485 (OPT) / 3000B : RS-232C / 2000A : N/A Relay output 3000A : HH, H, L, LL & Cleaning / 3000B, 2000A : High, Low & Cleaning IP Rating IP65 / IP64 / IP54 Display Trend graph, Measuring value, Measuring status, Unit Size 240 x 180 x 115mm / 155 x 155 x 184mm / 96 x 96 x 125mm Installation Wall mounting / DIN 144 panel mounting / DIN 96 panel mounting Power 110 / 220V, 50 / 60Hz3 4
  • 5. DWA-3000A/3000B/2000A Dissolved Oxygen Analyzer DO Electrode Model D34 / D21(Replaceable membrane) Model D13F Wastewater (D34), Pure water, Application Application General (D21) Clean water Range 0 ~ 20 ppm Range 40 ppb ~ 20 ppm Temp. Range 0 ~ 80 C ˚ Temp. Range 0 ~ 80 C ˚ Temp. Sensor PT1000 Temp. Sensor PT1000 Water Quality Measuring On-line System Max. 0.4Mpa (D34) Pressure Max. 0.3Mpa Pressure Max. 0.3Mpa (D21) Body Material SUS316L Body Material PPS Cable Fixed cable Cable Fixed cable Thread PG13.5 Thread 3/4" NPT Submersion/ Holder Submersion/Flow through Holder Flow through Model 21M (For replacement membrane) Features Body Material PTFE / POM Real Time Trend Analysis Function Microprocessor-based Digital Program Controller Components Electrolyte x 1 bottle Membrane x 3 pcs Isolated DC (4-20/0-20/0-24mA) Output Transmission Automatic Cleaning Control Function Low-cost For User Satisfaction CE Mark Accredited DO System configuration (2000A) NO. MODEL MATL 1 POWER CABLE 2.0SQ×3C FR-CVV 2 CLEANER CABLE 1.25SQ×2C FR-CVV 3 ANALOG CABLE 1.25SQ×2C FR-CVVSB 4 DIGITAL CABLE 4C×20#AWG SHIELD 5 AIR HOSE ф6 6 SOLVALVE 1/4 PT 〞 AIR ONLY Specification Range 0 ~ 20 mg/L (Resolution : 0.01) Method Polarograph Accuracy ±1 % (Of Full Scale) Response time 120 sec (90% saturation) Analog output Isolated 4~20mA DC (STD) / 0~20mA, 0~24mA(OPT) Digital output 3000A : RS-232C (STD), RS-485 (OPT) / 3000B : RS-232C / 2000A : N/A Relay output 3000A : HH, H, L, LL & Cleaning / 3000B, 2000A : High, Low & Cleaning IP Rating IP65 / IP64 / IP54 Display Trend graph, Measuring value, Measuring status, Temperature, Unit Size 240 x 180 x 115mm / 155 x 155 x 184mm / 96 x 96 x 125mm Installation Wall mounting / DIN 144 panel mounting / DIN 96 Panel mounting Power 110 / 220V, 50 / 60Hz5 6
  • 6. DWA-3000A/3000B/2000A Conductivity Analyzer Conductivity Electrode Model C001 / C01 Model C1 Pure water, Clean water (C001) Application General Application General (C01) Range 0 ~ 2,000 ㎲/cm 0 ~ 20 ㎲/cm (C001) Range 0 ~ 200 ㎲/cm (C01) Temp. Range 0 ~ 100 C ˚ Temp. Range 0 ~ 100 C ˚ Temp. Sensor PT1000/Order Water Quality Measuring On-line System Temp. Sensor PT1000/Order Pressure Max. 1.0Mpa Pressure Max. 1.0Mpa Body Material SUS316L Body Material SUS316L Cable Fixed cable Cable Fixed cable Thread 1/2" NPT Thread 3/4" NPT Holder Submersion/Flow through Holder Submersion / Flow through Features CD System Configuration (3000A) Real Time Trend Analysis Function Microprocessor-based Digital Program Controller NO. MODEL MATL Isolated DC (4-20/0-20/0-24mA) Output Transmission 1 2 POWER CABLE CLEANER CABLE 2.0SQ×3C 1.25SQ×2C FR-CVV FR-CVV Automatic Cleaning Control Function 3 4 ANALOG CABLE DIGITAL CABLE 1.25SQ×2C 4C×20#AWG FR-CVVSB SHIELD Low-cost For User Satisfaction 5 6 AIR HOSE SOLVALVE ф5 1/4 PT 〞 AIR ONLY CE Mark Accredited Specification Range 0 ~ 2,000 ㎲/cm or user spec’ Accuracy ±1 % (Of Full Scale) Response time 30 sec (90% saturation) Analog output Isolated 4~20mA DC (STD) / 0~20mA, 0~24mA(OPT) Digital output 3000A : RS-232C (STD), RS-485 (OPT) / 3000B : RS-232C / 2000A : N/A Relay output 3000A : HH, H, L, LL & Cleaning / 3000B, 2000A : High, Low & Cleaning IP Rating IP65 / IP64 / IP54 Display Trend graph, Measuring value, Measuring status, Temperature, Unit Size 240 x 180 x 115mm / 155 x 155 x 184mm / 96 x 96 x 125mm Installation Wall mounting / DIN 144 panel mounting / DIN 96 panel mounting Power 110 / 220V, 50 / 60Hz7 8
  • 7. DWA-3000A/3000B/2000A Residual Chlorine Analyzer Polarographic Electrode Model R70 Model R122470 Application Swimming Pool, Wastewater 0.05 ~ 10 mg/L Range 0.01~ 5 mg/L Range 0 ~ 20 mg/L Temp. Sensor PT1000/Order Temp. Sensor PT1000/Order Material SUS316L, POM, PTFE Material SUS316L Holder Flow through Holder Flow through Water Quality Measuring On-line System Cleaning Solenoid Auto Drain Cable Fixed Cable Operating Condition Thread None Pressure Max. 0.1Mpa Cleaning Solenoid Auto Drain Operation Flow 50ml/min Operating Condition pH Range 4~8.2pH Pressure Max. 0.1Mpa Operation Flow 50ml/min Temp. Range 4~45 ˚C pH Range 4~8.2pH Temp. Range 4 ~ 45 C ˚ Galvanic Electrode Features 70M Model DCL-8046 Model (For replacement membrane) Real Time Trend Analysis Function Range 0 ~ 2 mg/L Microprocessor-based Digital Program Controller Temp. Sensor PT1000 Isolated DC (4-20/0-20/0-24mA) Output Transmission Body TEFLON / POM Material Acryl Material Automatic Cleaning Control Function Holder Flow through Low-cost For User Satisfaction Cleaning Auto Beads Cleaning CE Mark Accredited Operating Condition Sample Out Operation Flow 1,000ml/min Electrolyte x 1 bottle Components Membrane x 3 pcs pH Range 5.6~7.6pH Temp. Range over 16 C ˚ RC System Configuration (3000B) NO. MODEL MATL 1 POWER CABLE 2.0SQ×3C FR-CVV 2 CLEANER CABLE 1.25SQ×2C FR-CVV 3 ANALOG CABLE 1.25SQ×2C FR-CVVSB 4 DIGITAL CABLE 4C×20#AWG SHIELD 5 AIR HOSE ф6~8 Sample In Specification Range 0 ~ 20 mg/L / 0.05 ~ 10 mg/L / 0.01 ~ 5 mg/L / 0 ~ 2 mg/L Method Polarographic / Galvanic Accuracy ±3 % (Of Full Scale) Response time 120 sec (90% saturation) Analog output Isolated 4~20mA DC (STD) / 0~20mA, 0~24mA(OPT) Digital output 3000A : RS-232C (STD), RS-485 (OPT) / 3000B : RS-232C / 2000A : N/A Relay output 3000A : HH, H, L, LL & Cleaning / 3000B, 2000A : High, Low & Cleaning IP Rating IP65 / IP64 / IP54 Display Trend graph, Measuring value, Measuring status, Temperature, Unit Size 240 x 180 x 115mm / 155 x 155 x 184mm / 96 x 96 x 125mm Installation Wall mounting / DIN 144 panel mounting / DIN 96 panel mounting Power 110 / 220V, 50 / 60Hz9 10
  • 8. DWA-3000A/3000B/2000A MLSS Analyzer MLSS Electrode Model MLSS-180 Range 0 ~ 15,000 mg/L Water Quality Measuring On-line System Body Material SUS304 , ACETAL Holder SUS316 Cable 10 m (STD) or user spec’ Features Cleaning Unit Air / Water Real Time Trend Analysis Function Microprocessor-based Digital Program Controller Isolated DC (4-20/0-20/0-24mA) Output Transmission Automatic Cleaning Control Function MLSS System Configuration (2000A) Low-cost For User Satisfaction CE Mark Accredited NO. MODEL MATL 1 POWER CABLE 2.0SQ×3C FR-CVV 2 CLEANER CABLE 1.25SQ×2C FR-CVV 3 ANALOG CABLE 1.25SQ×2C FR-CVVSB 4 AIR HOSE ф5 5 SOLVALVE 1/4 PT 〞 AIR ONLY Specification Range 0 ~ 15,000 mg/L (Resolution : 1) Method IR LED 880nm Transmitted (180 ˚) Accuracy ±3 % (Of Full Scale) Response time 30 sec (90% saturation) Analog output Isolated 4~20mA DC (STD) / 0~20mA, 0~24mA(OPT) Digital output 3000A : RS-232C (STD), RS-485 (OPT) / 3000B : RS-232C / 2000A : N/A Relay output 3000A : HH, H, L, LL & Cleaning / 3000B, 2000A : High, Low & Cleaning IP Rating IP65 / IP64 / IP54 Display Trend graph, Measuring value, Measuring status, Unit Size 240 x 180 x 115mm / 155 x 155 x 184mm / 96 x 96 x 125mm Installation Wall mounting / DIN 144 panel mounting / DIN 96 panel mounting Power 110 / 220V, 50 / 60Hz11 12
  • 9. DWA-3000A/3000B/2000A SS Analyzer SS Sensor Model SS-450 Model TCSS-200 Range 0 ~ 1,500 mg/L Range 0 ~ 100 or 0 ~ 200 mg/L Material SUS304 , ACETAL Material SUS304 , ACETAL Water Quality Measuring On-line System Cable 10 m (STD) or user spec’ Cable 10 m (STD) or user spec’ Cleaning Cleaning Air / Water Wiper Unit Unit Features SS System Configuration (3000A) Real Time Trend Analysis Function Microprocessor-based Digital Program Controller NO. MODEL MATL Isolated DC (4-20/0-20/0-24mA) Output Transmission 1 POWER CABLE 2.0SQ×3C FR-CVV 2 CLEANER CABLE 1.25SQ×2C FR-CVV Automatic Cleaning Control Function 3 ANALOG CABLE 1.25SQ×2C FR-CVVSB 4 DIGITAL CABLE 4C×20#AWG SHIELD Low-cost For User Satisfaction CE Mark Accredited Specification Range 0 ~ 1,500 mg/L or user spec’ Method IR LED 880nm Scattering (45 ˚) Accuracy ±3 % (Of Full Scale) Response time 120 sec (90% saturation) Analog output Isolated 4~20mA DC (STD) / 0~20mA, 0~24mA(OPT) Digital output 3000A : RS-232C (STD), RS-485 (OPT) / 3000B : RS-232C / 2000A : N/A Relay output 3000A : HH, H, L, LL & Cleaning / 3000B, 2000A : High, Low & Cleaning IP Rating IP65 / IP64 / IP54 Display Trend graph, Measuring value, Measuring status, Unit Size 240 x 180 x 115mm / 155 x 155 x 184mm / 96 x 96 x 125mm Installation Wall mounting / DIN 144 panel mounting / DIN 96 panel mounting Power 110 / 220V, 50 / 60Hz13 14
  • 10. DWA-3000A/3000B Turbidity Analyzer TBD Sensor Model TURB-902 / 905 / 910 / 9100 0 ~ 2 NTU Material SUS316, ACETAL 0 ~ 5 NTU Range Operation Flow 500 ~ 600 ml/min 0 ~ 10 NTU 0 ~ 100 NTU Holder Flow through Water Quality Measuring On-line System Features Real Time Trend Analysis Function Microprocessor-based Digital Program Controller Isolated DC (4-20/0-20/0-24mA) Output Transmission Automatic Cleaning Control Function Low-cost For User Satisfaction CE Mark Accredited TBD System Configuration (3000B) NO. MODEL MATL 1 POWER CABLE 2.0SQ×3C FR-CVV 2 ANALOG CABLE 1.25SQ×2C FR-CVVSB 3 DIGITAL CABLE 4C×20#AWG SHIELD Specification Range 0 ~ 10, 0 ~ 100 NTU or user spec’ Method IR LED 880nm Scattering Accuracy ±2 % (Of Full Scale) Response time 5 min (90% saturation) Analog output Isolated 4~20mA DC (STD) / 0~20mA, 0~24mA(OPT) Digital output 3000A : RS-232C (STD), RS-485 (OPT) / 3000B : RS-232C Relay output 3000A : HH, H, L, LL & Cleaning / 3000B : High, Low & Cleaning IP Rating IP65 / IP64 Display Trend graph, Measuring value, Measuring status, Temperature, Unit Size 240 x 180 x 115mm / 155 x 155 x 184mm Installation Wall mounting / DIN 144 panel mounting Power 110 / 220V, 50 / 60Hz15 16
  • 11. Installation Site Outdoor / Indoor Basic Selection Table Guide < For Water Quality Measuring On-line System > OSAN CITY ENVIRONMENTAL AFFAIR AGENCY PYOUNGTAEK THERMOELECTRIC POWER PLANT Measuring Subject Check Point : Water Quality Measuring On-line System A. General Specification 1. Process Line : 2. Installation Point : ( A : Indoor B : Outdoor ) 3. Tag No. : 4. Serial No. : 5. Measuring Subject : B. Process (Set-Up) Environment 1. Measurement Range : 2. Structure Type : ( A :Pond Type B : Pipe Type C : Tank Type ) 3. Flow rate : 4. Average Flow rate : 5. Temperature Range : SAMSUNG ELECTRO-MECHANICS BORYEONG POWER PLANT 6. Average Temperature Range : 7. Pressure Range : 8. Average Pressure Range : 9. Conductivity : 10. Sludge existence (Yes or No) : 11. Bubble existence (Yes or No) : 12. Steam existence (Yes or No) : C. Meter Selection 1. Type : ( A : DIN96 B : DIN144 C: Maker Standard ) 2. Protection grade : 3. Installation Method: ( A :Pipe Stanchion B :Wall Mounting C :Panel Mounting D :Others ) 4. Operating Temperature : 5. Power Supply : ( A : AC110V B : AC220V C : Others ) 6. Surrounding Temperature : 7. Surrounding Average Temperature : 8. Signal Output : ( A : 4~20mA B : 1~5V C : Others ) 9. Digital Interface : ( A : RS-232C B : RS-485 C : Others ) GYUNGWON HILLS GOLF RESORT INCHEON CITY SEWAGE DISPOSAL PLANT D. Sensor Selection 1. Application: 2. Measurement Range : 3. Operating Temperature Range : 4. Operating Pressure Range : 5. Temperature Compensation (Yes or No) : 6. Sensor formula Type : 7. Installation condition: ( A : Submersion B : Flow-through C : Insertion D : Sampling ) 8. Cleaning Method : ( A : No B : Water-jet C : Air-jet D : Others ) 9. Sensor Holder Length : 10. Sensor Holder Material : 11. Sensor Cable : 12. Sensor and Meter distance : ** Please check it and put down this Table before requesting on your quotation and send us it now for our prompt reference.17 18
  • 12. DWA-3000M Portable Multi-Parameter DWA-3000T On-line Multi-Parameter Description By 1 meter, User can measure multi Water Quality Measuring On-line System parameter water quality. Measuring desired water quality is Description possible by combination of sensors with CH1, CH2, CH3. This automatic on-line multi instrument can apply user’ request and it can make possible s to operate all the system best effectively by checking and analyzing the water on real time. Features • Channel : Min. 3CH ~ Max. 10CH or Order • Multi parameter of 10 items (pH,ORP,DO,Conductivity,RC,MLSS,SS, Turbidity,Resistivity,TDS&Temp) • Suitable electrodes for industry • 7 or 15 Touch panel PC Application. 〞 〞 Features (user spec’ ) • Real time trend analysis graph function • Channel : Min. 2CH ~ Max. 7CH or Order • RS-232C, RS-485 Communication • Multi parameter of 7 items (STD) • Self breakdown diagnosis function (pH,ORP,DO,Conductivity,Resistivity,TDS&Temp) • Sensor replacement period perception • Auto calibration of according to user’ setting s • Data memory save func’ Max. 6 month : • Data memory save func’ Max. 100 points : • CE Mark Accredited • RS-232 communication and easy to read. • CE Mark Accredited Specification Specification Model DWA-3000M Model DWA-3000T Channel Min. 2CH ~ Max. 7CH or Order Channel Min. 3CH ~ Max. 10CH or Order Meter : Adapter (Input : AC110/220V, Output : DC9V) / Ni-MH rechargeable battery 1.2 V x 6 ea (AA) Enclosure Material : Aluminum, Size : 632(w) x 2100(H) x 268(D) mm (In case of 5CH) Power Printer : Alkaline battery 1.5V x 4 ea (AA) Power AC110/220V, 50/60Hz, 3Watt Items pH ORP DO COND Resistivity TDS Temp Items pH ORP DO COND RC MLSS SS Turbidity Resistivity TDS Temp 0.00 ~ 0.00 ~ 0.00 ~ 0.00 ~ 0~ 0.00 ~ 0~ 0.00 ~ 0~ 0 ~15,000 0~ 0 ~ 10, 0.00 ~ 0~ Range ±2000 mV Range ±1,500 mV 14.00 pH 20.00 mg/L 200.00㎳/cm 20.00 MΩ 10,000 ppm 14.00pH 20mg/L 2,000㎲/cm 20mg/L mg/L 1,500mg/L 0 ~ 100 NTU 20.00 MΩ 10,000 ppm Accuracy ±0.01pH ±1 mV ±3 % ±3 % ±3 % ±3 % Accuracy ±0.01pH ±1 mV ±3 % ±3 % ±3 % ±3 % ±3 % ±3 % ±3 % ±3 % 0 ~ 99 ˚C 0~ Reproducibility ±0.01 pH ±1 mV ±3 % ±3 % ±3 % ±3 % 99 C ˚ Reproducibility ±0.01pH ±1 mV ±3 % ±3 % ±3 % ±3 % ±3 % ±3 % ±3 % ±3 % 30sec 60sec 120sec 30sec 30sec 120sec 30sec 30sec 120sec 30sec 120sec 180sec 180sec 5min 30sec 120sec Response time Response time (90%) (90%) (90%) (90%) (90%) (90%) (90%) (90%) (90%) (90%) (90%) (90%) (90%) (90%) (90%) (90%)19 20
  • 13. Mounting Example DO/pH/ORP/COND Installation (Example) 3000A Water Quality Measuring On-line System MLSS/SS Installation (Example) 3000B Turbidity Installation (Example) 2000A21 22
  • 14. RC Installation (Example) Sensor Holder Polarographic Sensor Submersion type Flow-through type Water Quality Measuring On-line System Holder Bracket Galvanic Sensor Installation Example23 24
  • 15. Digital Pocket CD Tester DMT-25 Digital Pocket pH Tester DMT-30 All DMT-25 have been factory tested All DMT-30 have been factory tested and calibrated for accuracy and calibrated for accuracy Digital Pocket Tester Specification Specification Model DMT-25 Model DMT-30 Measuring Range 0~2,000 ㎲/cm Measuring Range 0~14pH Measuring Method Replaceable Conductivity Electrode Measuring Method Replaceable Glass Electrode Measuring Subject Aqueous Solution Measuring Subject Aqueous Solution Accuracy ±1% (Of Full Scale) Accuracy ±0.02 pH Response time M < 60 sec (at 25 C) ˚ Response time M < 60 sec (at 25 C) ˚ Temp Range 0~40 C ˚ Temp Range 0~60 C ˚ Resolution 0.01㎲/cm Resolution 0.01pH Slope -50~-90nA (25 C) ˚ Calibration 3point at pH4, pH7 and pH10 Operating Temp 5~40 C ˚ Slope 0-10pH-(PTS)≥98.5(25 C) ˚ Operating Humidity (≤85%) Below 85% R.H Operating Temp 5~40 C ˚ Description Temp Compensation Automatic 0~50˚C (ATC) Description Operating Humidity (≤85%) Below 85% R.H Temp Compensation Automatic 0~100˚C (ATC) The DMT-25 is an inexpensive pocket type Power CR2032 Button Battery x 2pcs The DMT-30 is an inexpensive pocket type pH Power CR2032 Button Battery x 2pcs Conductivity Tester with easy to operate and Approximately 100 hours continuous Battery Life use Tester with easy to operate and replaceable Battery Life Approximately 100 hours replaceable electrode ideal for Environmental Dimension 30 x 30 x 195mm electrode ideal for Aquaculture(Fish Farm), Enviro continuous use industry. Weight Abt.61g (Including batteries) nmental(AquaticEcosystem),Industrial(Water Dimension 30 x 30 x 195mm Weight Abt.61g (Including batteries) intake & discharge processing), Education(Labs & Schools) fields and more. Features • Lightweight and compact • Quick, Stable & Accuracy result Features • Waterproof to IP57 Standard design floats • Lightweight and compact • User-replaceable electrode-reuse • Quick, Stable & Accuracy result • ATC Function • Waterproof to IP57 Standard design floats • Large & Easy to read LCD • User-replaceable electrode-reuse • Electronic self calibration • ATC Function • Inexpensive pocket type Conductivity Tester • Large & Easy to read LCD • Automatic shut-off • Electronic self calibration • Inexpensive pocket type pH Tester • Automatic shut-off25 26
  • 16. Digital Pocket ORP Tester DMT- 40 Digital Salt Tester DMT-20 All DMT-40 have been factory tested and calibrated for accuracy Home & Industrial Measurement Specification Model DMT-40 Measuring Range -999~999mV Measuring Method Replaceable Pt Electrode Measuring Subject Aqueous Solution Accuracy ±1mV Response time M < 60 sec (at 25 C) ˚ Temp Range 0~60 C ˚ Resolution 1mV Calibration 255mV(Quinhydrone)-Black "This product measures the concentration of dissolved Salt in water" Slope 265mV±30mV(25 C) ˚ Operating Temp 5~40 C ˚ Description Operating Humidity (≤85%) Below 85% R.H The DMT-40 is an inexpensive pocket Power CR2032 Button Battery x 2pcs Technology : 2 in 1 Functions Approximately 100 hours Battery Life type ORP Tester with easy to operate and continuous use - Measurement : Salt(%) / Temp.(℃/℉) replaceable electrode ideal for Monitor Dimension 30 x 30 x 195mm - Range : 0.0~5.0%(Salt) Ozone system, Aquarium & Aquaculture Weight Abt.61g (Including batteries) - Operating Temp. : 0~70℃ (32℉~158℉) monitoring, Water purification & Drinking - CE Mark Accredited Water, Water pollution monitoring, Pools & spas, Industrial(Pulp bleaching, chromate reduction etc.) fields and more. Application Fields : Home / Food Industry / Health-Care / Industry 1) Indispensable for those with SALT heaith concerns Features 2) Preservation of fixed taste of food 3) Salt amount of food measurement • User-replaceable electrode-reuse • Lightweight and compact • Quick, Stable & Accuracy result • Waterproof to IP57 Standard design floats • Large & Easy to read LCD • Electronic self calibration • Inexpensive pocket type ORP Tester • Automatic shut-off27 28
  • 17. Digital Hygro Thermometer DHT-1 Digital Thermometer HDT-1 4 Displays Humidity Temp. Timer and Clock Description (In/Out Sensor, Mini/Maxi) This Meter measures the Temperature in Liquids/Solids.(All Hot & Cold fluids/solids) Application Fields 4 IN 1 Home & Industrial Measurement • Kitchen & Bakeries / Oil for Frying • Storage/Cold-storage Foods Temp. of Freezing • Freezers/Coolers and Heating Systems ▶ Humidity • Hydroponics & Aquaculture • Motor Maintenance, Generator Systems etc. ▶ Temperature • Surface of the earth Temp of Flower/Flowerpot ▶ Timer ▶ Clock Features Specification • Range : -50° C~300° (-58° C F~572° F) • Very Competitive Price (Under Bottom Price) • Resolution : ±0.1° C • Complete with Hand-Held type • Power : LR44 or LR1154 button cell (1.5V) x 1ea • Durable ø4.0 S.S Probe (S.S NO.304) • Battery Life : Abt.12 months • Wide Temp range & Large LCD Display Based on 2 times use per day • Fast response • Dimension / Weight : 25 x 11 x 223mm / Abt.35g • CE Mark Accredited • Material: 1> Sensor Probe: S.S No.304 2> Body: ABS plastic Measurement • Humidity : 20~95% RH - Indoor : -30℃~50℃(-22℉~122℉) - Outdoor : -50℃~70℃(-58℉~158℉) • Timer : Min / Sec • Clock Format : 24 Hour • Clock Alarm : 60 sec • Jumbo 4-Display LCD • Min/Max : Hum, Temp. • In/Out Sensor : Temp. • ℃/℉ Exchange • Timer : Count down • 24H Clock & Alarm • Flip-Out Stand : Desk-Top/Wall mount • Power : AAA 1.5V×1EA29 30
  • 18. Digital Marine Tester DMT-10 bo Digital Salt Checker DMT-20-1 iJum Min Specific Gravity Salinity Temperature “ Mini, Slim and Compact ” Aquariums & Pets Supply • Measures Specific Gravity / Salinity(ppt) / Temperature(℃ or ℉) • Handheld Digital Tester : Easy to read Digital LCD & operate 3 IN 1 Take Control of Your Salt Intake!! • Automatic Temperature Compensation & Waterproof probe • Laboratory grade for presicion accuracy Specific Gravity : 1.000~1.037 Salinity(ppt) : 0ppt~50ppt • Fast Response : Instantly get results within 10 sec. Temperature(℃ or ℉) • Battery Saving Function : Automatically turns off within 1 min. Features / Specification • CE Mark Accredited • Mini, Slim & Compact : 120mm(L) / 12.80mm(T) / 23g(Weight) • Salt Range : 0.0~1.5% • Temperature : ATC(0~70℃) • Preservation of Fixed Taste of Food • Salt Amount of Food Measurement • CE Mark Accredited31 32
  • 19. Portable Chloride-Meter DY-2501A Digital Concrete Air-Meter DY-300 <Field Test System> <Field Test System> Quickly determine percentage of entained Air in Freshly mixed Concrete Measuring & Testing Equipment by Digital Digit in LCD Ideal for Construction sites / Ready-Mixed Concrete works... • Digital Measuring System(By the pressure method) • With built in automatic electric Air compressor giving Air pressure & Keeping it constant all along the test (Max. 120.0 kPa / 20 Sec.) • Original Volume of Air is by the principle of Boyles Law • Automatic Calibration : 2 points (0%, 4.5%) • Easy to read, operate and accuracy • CE Mark Accredited “ Measures the content of Chloride contained in concrete” - Capacity : 7 Liters - Air Content Range : (0.00~9.99 % selectable) - Range : 0.001%~1.500&(Cl-) - Dual Digital Digit LCD - Accuracy : ±0.1%(2 Digit)/ ± 0.05% (3 Digit) @ 25℃ - Automatic Temp. Compensation(ATC) - Memory Recalling holds 100 Readings. - Air Pressure Sensor : Ceramic Cell - All-Function-in-One - Easy to carry & operate(Portable) Max. 200.0 kPa, Div : 0.1 kPa (Calibration/Measurement/Printing etc.) - Fast Results : Abt. 2 Min - Power : Ni-MH×8 Pcs (Rechargeable) - CE Mark Accredited - Display Meter Size / Weight ; 120×110×125 mm/Abt. 1.1kg33 34
  • 20. Portable CHLORIDE-METER DY-2501B Water Quality Measuring On-line System For Hardened Concrete <Field Test System> “ Both Hardened & Fresh Concrete Can be tested with this system for chioride” Certificates - Measurement · Content of Acid Soluble chloride(%) · Content of Water-Soluble chloride(%) · Total Volume of chloride (kg/m3) - Range : 0.0005 % ~ 2.0000 % (CI - ) - Measuring Method : By Combi chloride ISEs - All Function-In-One - Automatic Temp. Compensation (ATC) - Memory Recalling holds 100 Readings - Digital Digit LCD - Fast Response : Abt. 2 Min - CE Mark Accredited35 36
  • 21. Home/Aquariums/Industrial Measurement Measuring & Testing Equipment Certificates37 38
  • 22. < Application 사례 > < Application 사례 >

×