3 8 12 Overview Of New Products Pat
 

3 8 12 Overview Of New Products Pat

on

  • 706 views

APC NEW Products 2012

APC NEW Products 2012

Statistics

Views

Total Views
706
Views on SlideShare
695
Embed Views
11

Actions

Likes
0
Downloads
16
Comments
0

1 Embed 11

http://www.linkedin.com 11

Accessibility

Categories

Upload Details

Uploaded via as Microsoft PowerPoint

Usage Rights

© All Rights Reserved

Report content

Flagged as inappropriate Flag as inappropriate
Flag as inappropriate

Select your reason for flagging this presentation as inappropriate.

Cancel
  • Full Name Full Name Comment goes here.
    Are you sure you want to
    Your message goes here
    Processing…
Post Comment
Edit your comment

    3 8 12 Overview Of New Products Pat 3 8 12 Overview Of New Products Pat Presentation Transcript

    • Data Center Products Pat Gentile Consulting Engineer Specialist Patrick.Gentile@SCHNEIDER-ELECTRIC.COMAll content in this presentation is protected – © 2008 American Power Conversion Corporation
    • Who is APC? A Heritage of leadership, experience and innovation ● APC was acquired by Schneider Electric in 2007 ● MGE UPS Systems, another division of Schneider Electric, merged with APC ● Together they represent the IT Business Unit of Schneider ElectricAPC by Schneider Electric
    • Portfolio from 10kVA to 1600kVA Symmetra LX Symmetra PX Symmetra MW The broadest UPS portfolio in the industry with solutions from the wiring closet to the data center to the factory floor. Smart-UPS Smart-UPS VT MGE Galaxy MGE EPSAPC by Schneider Electric
    • Where does the power go? Infrastructure ITAPC by Schneider Electric
    • Typical UPS efficiency curve Below 30% load Nominal 92% efficiency only applies efficiency drops rapidly when UPS load is over 70% 100% 90% 80% 70% 60% 50% 40% 30% 20% 10% 0% 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% UPS Load % of full power ratingAPC by Schneider Electric
    • Scalable Modular UPS ● White space or backroom install Key Features ● Double conversion online topology ● 96% efficiency – highest in its class ● Input PF regulated to unity ● 400 or 480VAC input/output ● 1.0 output PF (kW=kVA) ● Dual mains ● Internal bypass static switch ● On-the-fly/ off-line firmware upgrades ● Event logging w/ graphs ● Regulated fan speed (reduces noise) ● Extended life batteries (5 – 8 yrs) ● Predictive maintenance ● Waveforms graphically displayed Redundant, Scalable, High Availability Power ProtectionAPC by Schneider Electric
    • Symmetra®® PX250/500kW500kW of High-Efficiency Scalable Power Protection 475kW 450kW 425kW 400kW 375kW 350kW 325kW 300kW 275kW 250kW 225kW 200kW 175kW 150kW 125kW 100kW 75kW 50kW 25kWAPC by Schneider Electric
    • Modular Designs Hot air is exhausted to the hot aisle and Air conditioners return neutralized (ambient returns to the back of the air conditioners room temperature) air to the front of the racks Hot aisle Cold aisle Integral row-based air conditioners Instrumented with local display and networked to central management systemAPC by Schneider Electric
    • 400 VAC Data Center Power Distribution 400 VAC Configuration Utilizes no PDUs to Transform UPS voltage to Server Power Supply Voltages  400Y/230 VAC, 3 Phase, 4 W + G to Rack.  Distribution More Closely Sized to the System Rating.  Single Autotransformer or 400 VAC UPS System can be used. Greatly Reduced Weight and Footprint Considerations in the Data Center White Space. No or Reduced XFMR Heat Losses 400Y/230 VAC. Five Conductors, A, B, C, N, G, Lower AmperageAPC by Schneider Electric
    • What is Modular Power Distribution? ● A simple, cost effective solution to install 3PH Power Distribution infrastructure ● Populated with Breaker Modules as capacity is needed ● No hot-work ● No downtime ● Includes: ● Enclosure ● Breaker Module with whip (cord set) and connector ● Branch Current Monitoring ● Breaker Position MonitoringAPC by Schneider Electric – Name – Date
    • High Density, High Efficiency Distribution ½ Rack Power Distribution Unit (PDU) Distribution ½ Rack Remote Power Panel (RPP) Modules PDU 480V:415V/240Y •266kW @320A •72 Poles •24 Modules RPP •20A 400V RPP (transformerless) •IEC309 connector •277 kW 400A •3XC19 •Circuit monitoring included •72 Poles •Breaker position monitoring •24 ModulesAPC by Schneider Electric – Name – Date
    • Power Monitoring Features • RMS: • Voltage available to load at each phase • Current in each phase of distribution cable • Percent current loading in each phase of distribution cable • Total KW usage of each distribution cable • Total KWh usage for each distribution cable • Individual reset of KWh usage per distribution cable • User programmable string to identify: • Location of load equipment fed by distribution cable • Load of equipment, fed by distribution cable • User programmable upper and lower • Warning current thresholds for each distribution cable • Critical current thresholds for each distribution cableAPC by Schneider Electric – Name – Date
    • Next Gen Rack PDU Design Benefits Low profile breakers Space saving form factors New low profile breaker for decreased interference with Low profile 0U designs maximize rack mounted IT equipment available space and increased airflow efficiency (select AP8000 series Rack PDUs) APC Industry Outlet Status LED Low Standard Profile Indicate on/off status of each individual outlet (AP8900 and 51.2mm 90 mm AP8600 series only) Locking IEC Cords Optional solution to secure Local display your power cords Local display allows users to make real-time decisions Temperature/Humidity Probe input cord allows use of external temperature/humidity probesAPC by Schneider Electric – Name – Date
    • Next Generation Rack PDU Features New Interactive LCD Display and Advanced Remote Management Connectivity Industry’s First APC Exclusive Ultra Low-Profile Breakers Locking IEC Connectors APC Industry Low Standard Profile 2.0” 3.5” 51.3mm 88.9mm Avoid space interference with IT equipment and improve airflow with these low profile branch-rated, hydraulic- Easy to install and space saving solution magnetic type breakers – The best overcurrent protection to secure critical power cords for high temperature rack enclosure environments!APC by Schneider Electric
    • What is ‘In-Row’ Cooling? Traditional (Perimeter) Design In-Row DesignAPC by Schneider Electric
    • InRow Cooling Architecture ● InRow Cooling ● Close coupled heat source and heat removal ● Raised floor not required for air distributionAPC by Schneider Electric
    • Row Cooling Product Solutions ACRD1XX, ACRD2X ACRC1XX, Model # ACRP1XX ACRP5XX ACSC1XX ACRD5XX X ACRC 5XX Product InRow InRow RD InRow RC InRow RP InRow RP InRow SC Family RD Heat Water/Gl Chilled Chilled Self Air-Cooled Air Cooled Rejection ycol Water Water Contained 2.8 Ton / 5 Ton / Nominal 10kW 2.8 Ton 18kW, 8.2 Ton / 23.3 Ton / 1.4 Ton / Capacity 8.2Ton / 29 /10kW 12.3 Ton / 29kW 43kW 5kW kW 43 kW 12 in 12 in (300 12 in Nominal (300mm), 24 in (600 24 in (600 12 in (300 mm), 24 in (300 Width 24 in mm) mm) mm) (600mm) mm) (600mm)APC by Schneider Electric
    • Air Containment Rack Air Containment Hot Aisle Containment System (RACS) System (HACS)APC by Schneider Electric
    • InRow OA System Architecture InRow OA InRow OA Mounting Kit Modular Piping R-134a Piping Headers (RDU to InRow OA) Chilled Water Piping (RDU to Chiler) Refrigerant Distribution Unit Air Containment (RDU) Curtain IT RacksAPC by Schneider Electric
    • InRow OA Design Benefits Aisle Width: Micro Channel Independent Heat Exchanger Variable Speed Hot Swappable Fans Integrated Lighting Primary and Rollers Secondary Power InputsAPC by Schneider Electric
    • Uniflair Room Cooling Technical PresentationAll content in this presentation is protected – © 2008 American Power Conversion Corporation
    • Efficient - Components 111 Backward Curved EC Fans (EBM Pabst)2 Immersed Electrode Humidifier (Carel) 7 63 30% Efficiency Air Filters (MERV 7) 5 8 34 2 or 3-Way Valve & Actuator (Schneider Electric)5 Blue-Fin Coated Cooling Coil (Heatcraft/Luvata)6 9 Temperature and Humidity Sensor (Carel) 4 Manual Disconnect Switch (Schneider7 2 Electric) 10 18 User Interface (Carel)9 Microprocessor Controller (Carel) Pictured: TDCV2500 (25-Ton est. capabity)10 Integrated Airflow Switches11 Front Service AccessAPC by Schneider Electric
    • EcoBreeze – Theory of Operation High Level Application *Not to scale ● Sits outside the data center ● Optional ground or roof placement ● Turn-key solution ● Set it in place ● Run power and water to the unit ● Duct it to the spaceAPC by Schneider Electric
    • 3. Does their data center design allow space for the EcoBreeze outside the building?● The EcoBreeze is a large footprint. The customer site will need the required space to fit the system, including service clearances● 40’ Frame area 320ft2● 20’ Frame area 160ft2● Total 40’ frame area with service clearances is 1024 ft2● Total 20’ frame area with service clearances is 544ft2● This includes clearance on a ground or roof installation clearances 8ft – 10ft 4ftAPC by Schneider Electric
    • Hot ambient air is expelled through the condenser to the atmosphere Cool IT Air isHot Air is returned from suppliedthe Data Center through the98°F-102 F(~37°C-39°C) evaporator coil and back to the Data Center 77 F(~25°C) Indirect Heat exchange between the IT and ambient airstreams (Evaporative or Cool Ambient Air is Air-to-Air) brought in by the Scavenger Fan APC by Schneider Electric
    • All content in this presentation is protected – © 2008 American Power Conversion Corporation
    • greensource team Ez Housh ezh@greensourcecincinnati.com Elizabeth Housh Reynolds ereynolds@greensourcecincinnati.com Steven Surges ssurges@greensourcecincinnati.com Rhonda Bailey rbailey@greensourcecincinnati.com Website: www.greensourcecincinnati.com Phone: 1.866.846.4733APC by Schneider Electric