    • Manual of Petroleum Measurement Standards Chapter 4—Proving Systems Section 7—Field Standard Test Measures SECOND EDITION, DECEMBER 1998COPYRIGHT 2000 American Petroleum InstituteInformation Handling Services, 2000
    • COPYRIGHT 2000 American Petroleum InstituteInformation Handling Services, 2000
    • Manual of Petroleum Measurement Standards Chapter 4—Proving Systems Section 7—Field Standard Test Measures Measurement Coordination Department SECOND EDITION, DECEMBER 1998COPYRIGHT 2000 American Petroleum InstituteInformation Handling Services, 2000
    • SPECIAL NOTES API publications necessarily address problems of a general nature. With respect to partic- ular circumstances, local, state, and federal laws and regulations should be reviewed. API is not undertaking to meet the duties of employers, manufacturers, or suppliers to warn and properly train and equip their employees, and others exposed, concerning health and safety risks and precautions, nor undertaking their obligations under local, state, or fed- eral laws. Information concerning safety and health risks and proper precautions with respect to par- ticular materials and conditions should be obtained from the employer, the manufacturer or supplier of that material, or the material safety data sheet. Nothing contained in any API publication is to be construed as granting any right, by implication or otherwise, for the manufacture, sale, or use of any method, apparatus, or prod- uct covered by letters patent. Neither should anything contained in the publication be con- strued as insuring anyone against liability for infringement of letters patent. Generally, API standards are reviewed and revised, reafÞrmed, or withdrawn at least every Þve years. Sometimes a one-time extension of up to two years will be added to this review cycle. This publication will no longer be in effect Þve years after its publication date as an operative API standard or, where an extension has been granted, upon republication. Status of the publication can be ascertained from the API Measurement Coordination Department [telephone (202) 682-8000]. A catalog of API publications and materials is published annu- ally and updated quarterly by API, 1220 L Street, N.W., Washington, D.C. 20005. This document was produced under API standardization procedures that ensure appropri- ate notiÞcation and participation in the developmental process and is designated as an API standard. Questions concerning the interpretation of the content of this standard or com- ments and questions concerning the procedures under which this standard was developed should be directed in writing to the director of the Authoring Department (shown on the title page of this document), American Petroleum Institute, 1220 L Street, N.W., Washington, D.C. 20005. Requests for permission to reproduce or translate all or any part of the material published herein should also be addressed to the director. API standards are published to facilitate the broad availability of proven, sound engineer- ing and operating practices. These standards are not intended to obviate the need for apply- ing sound engineering judgment regarding when and where these standards should be utilized. The formulation and publication of API standards is not intended in any way to inhibit anyone from using any other practices. Any manufacturer marking equipment or materials in conformance with the marking requirements of an API standard is solely responsible for complying with all the applicable requirements of that standard. API does not represent, warrant, or guarantee that such prod- ucts do in fact conform to the applicable API standard. All rights reserved. No part of this work may be reproduced, stored in a retrieval system, or transmitted by any means, electronic, mechanical, photocopying, recording, or otherwise, without prior written permission from the publisher. Contact the Publisher, API Publishing Services, 1220 L Street, N.W., Washington, D.C. 20005. Copyright © 1998 American Petroleum InstituteCOPYRIGHT 2000 American Petroleum InstituteInformation Handling Services, 2000
    • FOREWORD This publication consolidates the latest changes and improved technology in Field Stan- dard Test Measures since it was Þrst published in October 1988. Units of measurement in this publication are in United States Customary (USC) units and the International System (SI) consistent with North American industry practices. This standard has been developed through the cooperative efforts of many individuals from industry under the sponsorship of the American Petroleum Institute (API) and with the assistance of the National Institute of Standards and Technology (NIST). Joint participation between the API and NIST has enabled a new gravimetric calibration facility for test mea- sures to be designed and built in Gaithersburg, MD. This new calibration laboratory will pro- vide higher accuracies, improved calibration service, and reduced volume uncertainties in Þeld standard test measure volumes determined at this new facility. API publications may be used by anyone desiring to do so. Every effort has been made by the Institute to assure the accuracy and reliability of the data contained in them; however, the Institute makes no representation, warranty, or guarantee in connection with this publication and hereby expressly disclaims any liability or responsibility for loss or damage resulting from its use or for the violation of any federal, state, or municipal regulation with which this publication may conßict. Suggested revisions are invited and should be submitted to the director of the Measure- ment Coordination Department, American Petroleum Institute, 1220 L Street, N.W., Wash- ington, D.C. 20005. iiiCOPYRIGHT 2000 American Petroleum InstituteInformation Handling Services, 2000
    • COPYRIGHT 2000 American Petroleum InstituteInformation Handling Services, 2000
    • CONTENTS Page 0 INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1 SCOPE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 2 REFERENCED PUBLICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 3 DEFINITIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 4 EQUIPMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 4.1 Materials and Fabrication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 4.2 Gauge Glass . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 4.3 Drain Lines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 4.4 Levels and Leveling. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 4.5 Neck . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 4.6 Scale Plate and Graduations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 4.7 Case . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 4.8 Outlet Valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 4.9 Nameplate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 4.10 Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 5 CALIBRATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 5.1 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 5.2 Calibrated Volume . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 5.3 Calibration Frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 5.4 Number of Calibration Runs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 5.5 Test Measure Control Charts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 5.6 Seals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 5.7 Disputes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 6 CALIBRATION METHODS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 6.1 Gravimetric Calibration of Neck Scale Test Measures . . . . . . . . . . . . . . . . . . . . . 8 6.2 Gravimetric Calibration of Slicker-Plate Test Measures . . . . . . . . . . . . . . . . . . . . 9 6.3 Volumetric Calibration of Neck Scale and Slicker-Plate Test Measures. . . . . . . . 9 7 INSPECTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 7.1 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 7.2 Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 7.3 Visual Inspection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 7.4 Cleaning Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 7.5 Integrity. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 8 OPERATION AND USE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 8.1 Field Use of Volumetric Test Measures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 8.2 Normal Test Measure Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 8.3 Irregular Test Measure Operations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 vCOPYRIGHT 2000 American Petroleum InstituteInformation Handling Services, 2000
    • CONTENTS Page APPENDIX A ACCURACY REQUIREMENTS FOR VOLUMETRIC TEST MEASURES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 APPENDIX B CALCULATION OF UNCERTAINTY OF A FIELD STANDARD TEST MEASURE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 APPENDIX C TEST MEASURE CONTROL CHARTS . . . . . . . . . . . . . . . . . . . . . . . . 31 APPENDIX D LABORATORY WEIGHTS AND MASS STANDARDS . . . . . . . . . . 33 APPENDIX E NIST CERTIFICATES OF CALIBRATION FOR FIELD STANDARD TEST MEASURES (EXAMPLES) . . . . . . . . . . . 35 APPENDIX F WATER DENSITY EQUATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 Figures 1 Various Types of Standard Test Measures (I) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 2 Various Types of Standard Test Measures (II) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 3 Field Standard Test MeasureÑInvertible Type . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 4 Field Standard Test MeasureÑBottom Drain Type . . . . . . . . . . . . . . . . . . . . . . . . 19 5 Gauge Glass and Scale Assembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 6 Field Standard Test Measure Control Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 7 Levels of the Petroleum Measurement Hierarchy . . . . . . . . . . . . . . . . . . . . . . . . . 26 Tables 1 Capillary Rise in Gauge Glass Tubes with Varying Water Quality . . . . . . . . . . . . . 3 2 Effect of Out-Of-Level of Normal Sensitivity Test Measures on Gauge Glass Level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 3 Effect of Out-Of-Level of Normal Sensitivity Test Measures on Measure Volumes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 4 Scale Graduations for Normal-Sensitivity Test Measures . . . . . . . . . . . . . . . . . . . . 5 5 Scale Graduations for High-Sensitivity Test Measures . . . . . . . . . . . . . . . . . . . . . . 5 6 Scale Meniscus Errors Due to Contaminated Water . . . . . . . . . . . . . . . . . . . . . . . . 5 7 Range Limits versus Number of Calibration Runs. . . . . . . . . . . . . . . . . . . . . . . . . . 7 8 Volume Errors Due to Test Measure Internal Deposits . . . . . . . . . . . . . . . . . . . . . 11 A1 Hierarchy of Measurements for the Metered Volumes of Petroleum. . . . . . . . . . . 23 A2 Uncertainty Requirements for a Petroleum Measurement Hierarchy Using a Single Custody Transfer Meter and the Waterdraw Calibration of a Displacement Prover . . . . . . . . . . . . . . . . . . . . . . . . . 23 A3 Uncertainty Limits for Calibration of Normal Sensitivity Test Measures as Used in the Calibration of Conventional Displacement Provers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 A4 Uncertainty Limits for the Calibration of High Sensitivity Test Measures as Used in the Calibration of Small Volume Provers . . . . . . . . . . . 24 A5 Uncertainty Limits for the Calibration of Test Measures Used for Displacement Provers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 A6 Hierarchy of Petroleum Metered Volume Measurements Including Calibration of Meter Provers by a Master Meter . . . . . . . . . . . . . . . . . . . . . . . . . . 24 A7 Uncertainty Requirements for a Petroleum Measurement Hierarchy Including a Single Custody Transfer Meter With Master Meter Prover Calibration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 viCOPYRIGHT 2000 American Petroleum InstituteInformation Handling Services, 2000
    • CONTENTS Page A8 Total Hierarchy of Measurements of Metered Volumes of Petroleum Showing International Standards, Calibration of Test Measures Other Than by NIST and Meter Prover Calibration by a Master Meter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 B1 Uncertainty for the Gravimetric Determination of the Contained Volume at Room Temperature of NISTÕs 100-gallon (0.379 m3) Neck Scale Test Measure . . . . . . . . . . . . . . . . . . . . . . . . . . 28 B2 Uncertainty for the Gravimetric Determination of the Contained Volume at Room Temperature of NISTÕs 50-gallon (0.189 m3) Neck Scale Test Measure . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 B3 Uncertainty for the Gravimetric Determination of the Contained Volume at Room Temperature of NISTÕs 5-gallon (0.0189 m3) Neck Scale Test Measure . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 B4 Uncertainty for the Gravimetric Determination of the Contained Volume at Room Temperature of NISTÕs 5-gallon (0.0189 m3) Slicker Plate Test Measure. . . . . . . . . . . . . . . . . . . . . . . . . . 30 C1 Statistical Analysis Table of the Calibration History of Test Measure #123456 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 D1 Maximum and Minimum Limits for Density in g/cm3 . . . . . . . . . . . . . . . . . . . . . 34 D2 Application of Standard Mass Weights. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 viiCOPYRIGHT 2000 American Petroleum InstituteInformation Handling Services, 2000
    • COPYRIGHT 2000 American Petroleum InstituteInformation Handling Services, 2000
    • Manual of Petroleum Measurement Standards—Proving Systems Field Standard Test Measures 0 Introduction NIST1 A Þeld standard test measure is a vessel fabricated to meet Handbook 105 SpeciÞcations and Tolerances for Reference speciÞc design criteria and calibrated by an ofÞcial agency Standards and Field Standard Weights and such as the National Institute of Standards and Technology Measures, Part 3ÑSpeciÞcations and Toler- (NIST). Its primary purpose is to provide a standardized vol- ances for Graduated Neck-Type Volumetric ume, used for the calibration of displacement and tank prov- Field Standards ers, when calibrated by the waterdraw method. 3 Definitions 1 Scope 3.1 borosilicate glass: A glass with a low coefÞcient of This chapter details all the essential elements of Þeld stan- thermal expansion. dard test measures by providing descriptions, construction details, calibration procedures, operation, inspection, and 3.2 brim test measure: A vessel similar to a Þeld stan- Þeld use requirements. Accuracy and uncertainty require- dard test measure, except it has no sight glass and neck scale. ments are also discussed. The normal volume range for test It is Þlled until the liquid just extends to the top of the neck measures is 1 to 1,000 gallons, approximately 4 to 4,000 due to surface tension. Any liquid overßow is caught in the liters. The information contained in this chapter is limited to reservoir below and drained away and/or measured. atmospheric, graduated neck type, metal, volumetric Þeld- 3.3 calibrated volume: Also deÞned as the Base Mea- standard test measures. The volume is determined between an sure Volume (BMV); the delivered volume of a Þeld standard upper neck scale zero, and either a solid bottom or a tapered test measure, at its reference temperature, between its deÞned bottom with a drain line and shut-off valve, depending on the Òfull and emptyÓ levels. size of the test measure. Bottom-neck scale test measures and prover tanks are not addressed in this document. 3.4 calibration: A set of operations which establish, Test measures are classiÞed as: under speciÞed conditions, the relationship between the val- a. ÒTo deliverÓ volumetric test measures. ues indicated by a measuring device and the corresponding b. ÒTo containÓ volumetric test measures. known values indicated when using a suitable measuring standard. Guidelines are provided in this document for the design, manufacture, calibration, and use of new and/or replacement 3.5 cessation of main flow: During the draining of a test measures and are not intended to make any existing test Þeld standard test measure, the moment when the full dis- measures obsolete. charging water stream ÒbreaksÓ and becomes a small trickle. 3.6 clingage: The Þlm of liquid that adheres to the inside 2 Referenced Publications surface of a Þeld standard test measure after it has been The following standards, codes, and speciÞcations contrib- drained and is considered empty. uted to this standard and have been used as an appropriate resource for reference material: 3.7 field standard test measure: DeÞned as a volu- metric, nonpressurized, round, metal container, with a cylin- API drical neck containing a gauge glass and scale. Designed to Manual of Petroleum Measurement Standards stringent speciÞcations, it ÒcontainsÓ or ÒdeliversÓ an exact Chapter 1ÑVocabulary volume between a Þxed bottom or a bottom shut-off valve Chapter 4.2ÑConventional Pipe Provers and an upper neck scale reading. Chapter 4.3ÑSmall Volume Provers Chapter 4.4ÑTank Provers 3.8 high-resolution type: A Þeld standard test measure Chapter 4.8ÑGuide to the Operation of Proving designed with a smaller diameter neck, which is used to Systems achieve greater neck volume resolution in reading the water Chapter 7ÑTemperature Determination level meniscus. This type of test measure is also characterized Chapter 11ÑPhysical Properties Data by the terms Òhigh-sensitivityÓ or Òhigh-accuracyÓ. Chapter 12ÑCalculation of Petroleum Quantities Chapter 13ÑStatistical Aspects of Measuring and 1National Institute of Standards and Technology, Gaithersburg, Sampling Maryland 20899. 1COPYRIGHT 2000 American Petroleum InstituteInformation Handling Services, 2000
    • 2 API CHAPTER 4—PROVING SYSTEMS 3.9 measurement: A procedure to determine the value of 4 Equipment a physical variable. Statements that best describe the quality of these measurements as used in this standard are deÞned 4.1 MATERIALS AND FABRICATION below: A vessel used as a Þeld standard test measure shall be con- a. Accuracy. Describes the degree of closeness between mea- structed of corrosion-resistant stainless steel. All parts of the sured values and the true value. main body of the test measure shall be made of the same material. b. Error. Describes the difference between a measured value and the true value. All interior seams shall be Þlled and ground smooth enough to prevent any entrapment of air, liquid, or foreign c. Precision. Describes the degree to which all the data material. within the set of measurement variables is clustered together. Fabrication shall ensure that no pockets, dents, or crevices d. Range. Describes the area between a high value to a low are present that may entrap air or liquid or impair the proper value. Þlling or draining of the standard. e. Repeatability. Describes the measure of agreement The materials of construction of the Þeld standard test between the results of successive measurements of the same measure shall be thermally stable and not have an unduly variable, by the same method, with the same instrument and high coefÞcient of thermal expansion, which might render the operator, at the same location, over a short time period. test measure unsuitable for Þeld use. All applicable physical f. Tolerance. Describes the maximum permissible error in a property data must be reliably documented. series of measurements. Any horizontal cross-section shall be circular, and the g. True value. Describes the only correct value of a variable. shape of the vessel shall permit complete emptying and drain- h. Uncertainty. Describes the range of deviation between a ing. Dimensional requirements for U.S. Customary and Met- measured value and the true value, expressed as a percentage. ric Test Measures are shown in Tables 1a and 1b of the NIST For example, a device with an accuracy of 2% would have an Handbook 105-3, July 1997, pages 18Ð19. uncertainty of ±2%. Where appropriate, reinforcing bands shall be used to pre- 3.10 reference temperature: The temperature at which vent distortion of the measure or Þeld standard when it is full the test measure is intended Òto containÓ or Òto deliverÓ its of liquid. nominal capacity. The opening at the top of the neck shall be structurally durable because of the thickness of the metal, or it shall be 3.11 slicker-plate test measure: Described as a vessel reinforced. similar to a Þeld standard test measure, except it has no sight The top of the neck shall be Þnished so that the level position glass and neck scale. It is Þlled so that the liquid just extends of the Þeld standard test measure can be determined by placing above the top of the neck, due to surface tension, where the a machinistÕs precision spirit level across it. Proper adjustment excess is sheared off by sliding a transparent plate across the of all replacement levels shall be achieved in this manner. top of the neck. The bottom of the Þeld standard test measure shall be designed to prevent distortion when it is Þlled with liquid and 3.12 “to contain” volume: A method of characterization prevent damage during use. of a Þeld standard test measure that determines its contained A Þeld standard test measure in use must be leveled and volume, at reference temperature, when it is Þlled from a stand solidly on a surface with its vertical axis perpendicular clean, dry, empty, condition. to that surface. 3.13 “to deliver” volume: A method of characterization of a Þeld standard test measure that determines its delivered 4.2 GAUGE GLASS volume, at reference temperature, when it is emptied from its A Þeld standard test measure shall be equipped with a full condition and drained in accordance with the prescribed gauge glass mounted on the side of the neck. draining time. This gauge glass shall be made of borosilicate type glass or 3.14 traceability: The property of the result of a measure- equivalent, and shall be free from any irregularities or defects ment or the value of a standard whereby it can be related to that will distort the appearance of the liquid surface. Any stated references, usually national or international reference gauge glass made of a substitute material must be impervious standards, through an unbroken chain of comparisons, all to petroleum products. controlled, and having stated uncertainties. It should be noted The gauge glass shall be installed to facilitate cleaning and that traceability only exists, when scientiÞcally rigorous evi- removal. Replacement glass must conform to the original size dence is collected, on a continuing basis, showing that the and bore speciÞed by the manufacturer. The bottom mounting measurement is producing documented results, for which the of the gauge glass shall be made leak proof, without the use of total measurement uncertainty in quantiÞed. cement, by using compressible gaskets or O-rings. RemovalCOPYRIGHT 2000 American Petroleum InstituteInformation Handling Services, 2000
    • SECTION 7—FIELD STANDARD TEST MEASURES 3 Table 1—Capillary Rise in Gauge Glass Tubes with Varying Water Quality Capillary Rise (in.) Gauge Glass Tube Diameter (in.) Pure Water Aerated Water Dirty Water 5/ 0.025 0.0060 0.016 8 3/ 0.015 0.0035 0.012 4 1 0.005 0.0011 0.005 and replacement of the glass shall be accomplished without be sealed and covered for protection. All seals should be difÞculty and without affecting the calibration of the measure. afÞxed with corrosion-resistant Series 316 stainless steel or Table 1 shows the effect of surface tension capillary rise equivalent wire. within the glass tube, when using different size gauge If a trailer is used for mounting and/or transporting a Þeld glass tubes, due to variability of water quality. Dirty water standard test measure, then it shall have provision for level- is shown for comparison only and is not intended to ing. Any truck on which a Þeld standard test measure is endorse or recommend the use of dirty or contaminated mounted shall be equipped with leveling jacksÑone near water in any test application. each corner of the vehicle. To achieve a higher precision in the calibration of Þeld 4.3 DRAIN LINES standard test measures and in their use, spirit-level precision If a drain line extends from the bottom center of a Þeld requirements shall be speciÞed. During each calibration run, standard test measure, the downward slope of the line must operating instructions should require test-measure level veri- provide complete and proper drainage. This drain line shall Þcation prior to scale reading after Þlling. A minimum dis- be sized to provide the maximum drainage rate possible con- crimination of two minutes (2) per division is recommended sistent with a smooth and controlled drainage, while empty- for all precision test measure levels. Liquid spirit levels vary ing the test measure with the drain valve fully open and in sensitivity from 30 minutes (30) per division to 5 seconds adhering to the prescribed draining time. Minimum drain per division. MagniÞcation must be used with high-precision sizes are described in NIST Handbook 105-3, July 1997, spirit levels. The potential error due to an out-of-level test Tables 1a and 1b, pages 18Ð19. measure can be estimated as follows: A test measure drain is described as a gravity discharge line between the bottom of the bottom cone and the shut-off e = x sin q valve. It shall have a downward slope of at least 5¡ from the horizontal plane. All pipes connected to the test measure where drain line, downstream of the shut-off valve, shall be posi- tioned at an elevation to ensure the complete emptying of the e = Scale reading error (in.), test measure. x = Distance from centerline of test measure to out- A test measure that is not in a permanent installation, side of gauge tube (in.), equipped with a bottom drain, shall have a minimum of three adjustable legs that will enable the test measure to be leveled. q = Out-of-level angle uncertainty. 4.4 LEVELS AND LEVELING Errors for various test measure sizes because of out-of- The level position of the Þeld standard test measure can be level conditions are shown in Tables 2 and 3. The uncertain- determined by placing a precision machinistÕs spirit level ties in the tables do not include potential errors as a result of across the top of the neck of the test measure. This level veri- level instability of the test measures, or possible structural Þcation must be determined in two directions, 90¡ apart, and instability. For the purposes of measurement, errors are also shall be used to verify the permanently mounted spirit levels. caused by the failure to re-level the test measures prior to All Þeld standard test measures shall be equipped with a reading the scale each time. minimum of two or more adjustable spirit levels, mounted at right angles to each other, or with equivalent leveling indica- 4.5 NECK tors on the upper cone in a protected position on the sides of the vessel. The adjusting screws for these levels shall be pro- The neck diameter of Þeld standard test measures shall be vided with a means of wire sealing and the level shall be consistent with their intended applications and required scale equipped with a protective cover. Once set the levels should resolution. The neck assembly, or the top cone area of the testCOPYRIGHT 2000 American Petroleum InstituteInformation Handling Services, 2000
    • 4 API CHAPTER 4—PROVING SYSTEMS Table 2—Effect of Out-Of-Level of Normal Sensitivity Test Measures on Gauge Glass Level Uncertainty in Scale Reading, ± in.3, versus Level Discriminationa Size of Test Measure (gal.) ±30 minutes per division ±10 minutes per division ±2 minutes per division 1 0.011 0.004 0.0007 5 0.011 0.004 0.0007 10 0.011 0.004 0.0007 25 0.015 0.005 0.0010 50 0.015 0.005 0.0010 100 0.020 0.007 0.0013 200 0.026 0.009 0.0017 500 0.041 0.014 0.0028 a Level discrimination is estimated as 1/ the minimum discrimination or resolution of the spirit level. 2 Table 3—Effect of Out-Of-Level of Normal Sensitivity Test Measures on Measure Volumes Uncertainty in Scale Reading, ± % Volume, versus Level Discriminationa Size of Test Measure (gal.) ± 30 minutes per division ± 10 minutes per division ± 2 minutes per division 1 0.056 0.020 0.0036 5 0.011 0.004 0.0007 10 0.006 0.002 0.0004 25 0.005 0.002 0.0003 50 0.002 0.001 0.0002 100 0.003 0.001 0.0002 200 0.004 0.001 0.0003 500 0.009 0.003 0.0006 a Level discrimination is estimated as twice the minimum discrimination or resolution of the spirit level. measure and neck assembly, may be designed to open front. The metric scale (m3) is recommended situated on the (swivel), provided that the assembly has a metal-to-metal right side of the gauge glass. Provisions shall be made allowing joint, sufÞcient clamping points to prevent distortion of the either scale to be adjusted individually so that the two zero joint, and a means of ensuring that the device is properly lines will lie in parallel planes. assembled, leveled and leak-free. The distance between scale graduations shall not be less than 1/16 in. (1.5 mm). 4.6 SCALE PLATE AND GRADUATIONS Scales shall be graduated both above and below the zero The scale plate shall be made of corrosion-resistant metal line. For neck sizes smaller than 17 in. (43 cm) in diameter, and shall be mounted tangent to the front of or directly behind every Þfth line on the scale shall be considered a major division the gauge glass. In either case, it shall not be more than 1/4 in. and shall be longer than the intermediate or subdivision lines. (6 mm) from the glass. Every major line shall be numbered with the volume to that If the scale is mounted behind the gauge glass, a shield mark. For neck diameters of 17 in. (43 cm) or larger, every should be provided to protect the glass and allow for replace- tenth line may be designated a major division line. For small- ment of the gauge glass without difÞculty. diameter, high-sensitivity measures that have diameters of 2, 3, If the scale adjustment provides for movement by incre- or 4 in. (5, 71/2, or 10 cm), every fourth or Þfth division is a ments only, the maximum increment shall be 1/4 of the small- major numbered division depending upon the scale increments. est scale division. A sufÞcient number of scale brackets (a minimum of two) Scale numbering on all Þeld standard test measures shall be shall hold the scale plate rigid. The brackets shall be mounted speciÞed on the scale in milliliters (ml), cubic inches (in.3), or on adjusting rods. other volume units. The units of measurement should be An adjusting rod shall be provided with a means for seal- clearly marked on the scale. To avoid confusion and possible ing that will prevent movement. The scale plate shall be errors in reading, dual numbering on any one scale (e.g. cubic securely attached to the brackets and provided with a means inches and decimal fractions of a gallon) is not permitted. Dual for sealing. Movement of the adjusting mechanism or scale numbering is permitted only if two scale plates are used; in this plate shall not be possible without breaking the seal. All seals case, the U.S. customary units scale (in.3) is preferred and should be afÞxed with corrosion-resistant Series 316 stainless located on the left when the test measure is viewed from the steel or equivalent wire.COPYRIGHT 2000 American Petroleum InstituteInformation Handling Services, 2000
    • SECTION 7—FIELD STANDARD TEST MEASURES 5 Table 4—Scale Graduations for Normal-Sensitivity Test Measures Neck Minimum Number Minimum Discrimination Maximum Scale Nominal Diameter of in.3 Between Graduations Spacing Gallon Size (in.) Above & Below 0 ( in.3) (in.) 1 37/8 15 1 0.085 5 37/8 15 1 0.085 10 37/8 30 1 0.085 25 5 60 2 0.102 50 5 120 2 0.102 100 7 250 5 0.130 200 10 500 10 0.127 500 17 1250 25 0.110 Table 5—Scale Graduations for High-Sensitivity Test Measures Neck Nominal Volume Minimum Discrimination Maximum Scale Nominal Diameter of in.3 Between Graduations Spacing Gallon Size (in.) Above & Below 0 ( in.3) (in.) 1 2 20 1/ 0.080 4 5 2 20 1/ 0.080 4 10 2 20 1/ 0.080 4 25 3 35 1/ 0.071 2 50 3 50 1/ 0.071 2 50 4 50 1 0.080 100 4 50 1 0.080 The graduation lines, numbers, and other information on alter its volume. Adequate protection, such as a strong padded the scale plate shall be permanent. Graduation lines shall be case, shall be provided for storing and transporting the test of uniform width. The width of the lines shall be no more measure. than 0.025 in. (0.6 mm) or less than 0.015 in. (0.4 mm). On scale plates mounted to the front of the gauge glass, the 4.8 OUTLET VALVE major (numbered) lines shall be at least 1/4 in. (6 mm) in length. The intermediate lines shall be at least 1/8 in. (3 mm) It must be noted that the outlet (drain) valve of a Þeld stan- in length. The major and intermediate lines shall extend to the dard test measure is a critical component of the calibrated edge of the scale plate nearest the gauge glass. The zero line volume, which if modiÞed or replaced will necessitate the shall extend completely across the plate. recalibration of the test measure. Test measure drain valves On a scale plate mounted behind the gauge glass, the major should be sealed, painted, or by some other method indicate (numbered) lines shall be at least 3/4 in. (19 mm) in length. whether the valve has been changed, modiÞed, replaced, or Intermediate lines shall be at least 1/2 in. (13 mm) in length. repaired in any way since the last calibration. If seals are used The zero line shall extend completely across the plate. they should be afÞxed with corrosion-resistant Series 316 Two commercially available classes of test measures are designated normal sensitivity and high sensitivity. Uncer- Table 6—Scale Meniscus Errors Due to tainty in the calibration is different for each class of the same Contaminated Water size test measure. This is due to the improved scale sensitiv- ity, and the repeatability of the smaller diameter neck in the Error,% Volume high-sensitivity test measures. Nominal Scale graduations for normal sensitivity test measures are Gallon Size Air in Water Dirty Water listed in Table 4. Scale graduation for high-sensitivity test mea- 1 Ð0.170 Ð0.108 sures are listed in Table 5. Scale reading errors due to using 5 Ð0.034 Ð0.022 contaminated water in test measures are shown in Table 6. 10 Ð0.017 Ð0.011 25 Ð0.006 Ð0.003 4.7 CASE 50 Ð0.003 Ð0.0015 100 Ð0.003 Ð0.0015 A Þeld standard test measure is a precision instrument and 200 Ð0.003 Ð0.0015 must be handled with great care to avoid damage that may 500 Ð0.004 Ð0.002COPYRIGHT 2000 American Petroleum InstituteInformation Handling Services, 2000
    • 6 API CHAPTER 4—PROVING SYSTEMS stainless steel or equivalent wire and provide positive integ- 5.2 CALIBRATED VOLUME rity that the drain valve has not been replaced. Test measures may be calibrated either Òto containÓ or Òto Many test measures have drain valves that are simply deliver.Ó A Þeld standard test measure can be designed and screwed into the drain line. The volume is altered if this valve built Òto containÓ a precise liquid volume when Þlled from a is turned to a different number of threads, either more or less. clean, empty, and dry condition. Test measures calibrated Òto The importance of this valve to the calibrated volume cannot containÓ are not used in prover calibrations, because the be overemphasized and properly sealing screwed drain valves ÒemptyÓ condition means empty, clean, and dry before every should be an absolute priority for volumetric test measures. use, usually an impractical Þeld operations requirement. Alternatively, a metal-to-metal ßange arrangement between Normally test measure volumes are used in the Òto deliverÓ the drain line and the drain valve is the preferred method of mode. To prepare the test measure for calibration use requires drain valve connection. that it is wetted prior to use. It should be Þlled with water to its This drain valve shall be a quick-acting full-opening valve, zero mark, leveled, and then drained exactly for the prescribed open-ended for visual inspection, or shall have a visual-inspec- draining time as given on the certiÞcate of calibration. The test tion device immediately downstream of the valve to detect measure is then returned to an upright position or its drain valve failure. This valve must be leak-free at all times. valve is closed leaving it with a controlled and repeatable amount of clingage (water) inside prior to use. To ensure that 4.9 NAMEPLATE this clingage quantity is repeatable means that the test measure must be completely Þlled, and then emptied, in strict compli- Each Þeld standard test measure shall bear in a conspicuous ance with the operating procedures and draining times that are place the name of the manufacturer, the nominal volume, and speciÞed on its calibration certiÞcate. Just wetting the interior a serial or identiÞcation number. The material from which the of the test measure prior to use is completely unacceptable. standard is constructed shall be shown together with its cubi- This standard dictates that water shall be used as the cali- cal coefÞcient of thermal expansion per ¡F (or ¡C) for that brating liquid because of its stability, low thermal coefÞcient material. of expansion, and high heat capacity. Instructions sent to NIST for the calibration of a Þeld stan- 4.10 ASSEMBLY dard test measure should clearly state that it is to be calibrated as a Òto deliverÓ volume, and indicate whether this calibration All parts of the assembly of a Þeld standard test measure shall be performed by the gravimetric or volumetric method. and all piping and valves that affect the volume of the prover If the volumetric method of calibration is chosen, then the shall be fully assembled by the manufacturer or supplier. calibrated volume of the test measure and all measurements subsequently made using it, will have a larger level of uncer- 5 Calibration tainty than if calibrated by the gravimetric method. This must be acceptable to all parties using this test measure. 5.1 GENERAL The prescribed draining time for all test measures cali- brated by NIST and drained by inverting, is currently 10 sec- The National Institute of Standards and Technology (NIST) onds after the cessation of main ßow. Similarly, the draining is the calibrating agency of choice in the United States for Þeld time for all NIST calibrated test measures having bottom standard test measures used to calibrate meter provers. drains, is currently 30 seconds after the cessation of main SpeciÞcations for test measures shall be in accordance with ßow. The actual prescribed draining time used however, shall this standard and the latest edition of NIST Standard Hand- be in accordance with the CertiÞcate of Calibration for the book 105-3. Calibrations shall be made using clean potable particular test measure in use. water as the calibrating liquid. CertiÞed laboratory graduates may be used for measuring partial volumes of the Þeld-stan- 5.3 CALIBRATION FREQUENCY dard test measure. The actual capacity of the test measure, as shown on the laboratory report or calibration certiÞcate, shall Field standard test measures calibrated by NIST, shall be used as the ofÞcial capacity rather than the nominal capac- be recalibrated at the following regularly prescribed inter- ity of the measure. Whenever possible, calibrations of the test vals of use: measure shall be maintained at an uncertainty of ± 0.01 per- a. Maximum certiÞcation intervals shall be as follows: cent or better. 1. All new test measures shall be calibrated prior to use Water-density data provided in API MPMS Chapter 11 (initial certiÞcation). should be compatible with the density used by the calibrating 2. All existing test measures, in regular use, shall be reca- agency. See Appendix F, Water Density Equations. librated every 3 years.COPYRIGHT 2000 American Petroleum InstituteInformation Handling Services, 2000
    • SECTION 7—FIELD STANDARD TEST MEASURES 7 3. Test measures stored and infrequently used may have For example, if the uncertainty limit for the calibration of a their recalibration suspended. Infrequent use has allowed test measure is ± 0.01%, the random uncertainty due to varia- some ßexibility between successive recalibrations. In this tions of the calibration runs should not exceed ± 0.0025% to situation, use of this test measure shall be allowed if it has ± 0.050%. The range limit for a speciÞc number of calibra- a valid certiÞcate of calibration current within the past 5 tion runs to meet a prescribed uncertainty limit of the average years. can be calculated as follows, using equation 20 from the API MPMS Chapter 13.2, November 1994. Control charts shall be maintained on every test measure (see Appendix C). where b. Test measures shall be calibrated any time there is evi- dence of damage, distortion, repairs, alterations, maintenance a( X ) W ( X ) = ---------------- - to the test measure or replacement of the drain valve that Z (%,n) could affect its volume or its use. c. If appropriate, it may be necessary to calibrate test mea- W (X) = Range Limit for a Set of Calibration Runs (%), sures after change of ownership. This calibration may or may not be necessary. It shall depend on the transfer circum- a ( X ) = Prescribed Uncertainty Limit for the Set of Cal- stances, i.e. the condition of the test measure at the time of ibration Runs (± %), transfer and its previously known calibration history. All these factors shall be considered in deciding whether a cali- Z ( %, n ) = Range to Estimated Uncertainty Conversion bration is necessary and should be determined after a careful Factor for Averages. check of all these parameters and in consultation with all (See Table II in API MPMS Chapter 13, interested parties. Section 2.) The calibrated volume of all test measures shall be reported to Þve or more signiÞcant digits. If a 95% ConÞdence Level is required for data analyses, All Þeld standard test measures for prover calibrations in the range limits versus number of calibration runs for an the United States, shall have a CertiÞcate of Calibration, uncertainty limit of the average of ± 0.005% are shown issued by NIST, that is current within the last 3 years. The below: CertiÞcate of Calibration provided by NIST for the test mea- sure shall be supplied to the owner, together with all the cali- For procedural uncertainty limits other than ± 0.005%, the bration data obtained during the calibration procedure. range limits can be modiÞed from the above values as On some occasions, the same test measure may be cali- follows: brated by two or more different national calibration agencies; e.g. NIST and the Canadian Standards Agency (CSA) may a( X ) both calibrate the same test measure for use in different coun- W ( X ) = ----------------------- ± 0.005% tries. Similarly, on occasions the same test measure can be calibrated in different units of measurement. For example, the where test measure may be calibrated in both in.3 and ml. This will require that two different certiÞcates of calibration, developed W (X) = the value from Table 7. either by the same calibrating agency, or by two different agencies, need to be issued. Units of measurement, test mea- 5.5 TEST MEASURE CONTROL CHARTS sure volumes, and required drain times must all be followed exactly for the speciÞc certiÞcate of calibration being used. Every test measure shall have a data record prepared and No interchanging of data or requirements between two differ- maintained by NIST, containing all the relevant information ent certiÞcates of calibration for the same test measure is per- pertaining to the history of the test measure. mitted. Table 7—Range Limits versus Number 5.4 NUMBER OF CALIBRATION RUNS of Calibration Runs When calibrating a test measure, a sufÞcient number of cali- Number of Calibration Runs Range Limits, W(X),% Average bration runs shall be conducted to ensure that the random 2 0.00063 uncertainty of the calibration measurements are no greater than 3 0.0034 1/ , and preferably 1/ , of the overall uncertainty speciÞed for 4 0.0064 2 4 the calibration. 5 0.0093COPYRIGHT 2000 American Petroleum InstituteInformation Handling Services, 2000
    • 8 API CHAPTER 4—PROVING SYSTEMS The relevant information should contain: where a. The identity of the test measure by owner and the ownerÕs From step d: number. P = The atmospheric pressure (mm of Hg), b. The makerÕs name, identiÞcation number, nominal volume, scale divisions, coefÞcient of expansion of material of con- U = The relative humidity (%), struction, dates and details of all types of cleaning performed. (Tair) = The air temperature (¡C). c. Calibration dates, corresponding seal numbers, together with Òto containÓ and Òto deliverÓ volumes. f. Level the test measure on the platform of the mass d. Uncertainty history. comparator. g. Weigh and record the empty mass of the clean and dry test The calibration history of all test measures shall be docu- measure to be calibrated. mented and recorded and a control chart developed for each h. Fill the test measure with distilled water up to the region of test measure. See Figure 6 and the discussion in Appendix C. the zero reference mark on the neck scale. Inspect the test measure for leaks. 5.6 SEALS i. Measure and record the temperature of the distilled water (Tw) in the test measure with a calibrated temperature probe. Calibration and subsequent certiÞcation must include the j. Read the water meniscus in the glass tube of the neck afÞxing of a tamper proof seal on the adjustable scale and scale, and record the deviation of the reading from the zero drain valve by the calibrating authority. reference mark in volume units. k. Weigh and record the mass of the Þlled test measure. 5.7 DISPUTES l. Drain the test measure for the prescribed draining period. At the end of the prescribed draining time, close the drain In the case of a dispute between interested parties over the valve. accuracy of a test measure, the disputed test measure shall be m. Weigh and record the mass of the drained test measure. submitted to NIST for Þnal judgement of its accuracy. n. Calibrate the neck scale in volume units: 1. ReÞll the test measure to a point approximately 50% 6 Calibration Methods below the zero reference mark on the test measureÕs neck scale. Volumetric and gravimetric calibration methods for test 2. Read and record the indicated value of the neck measures are described in the following sections. Uncertain- scale (1). ties associated with the volumes determined by both methods 3. Add a known volume of distilled water using an appro- are discussed in Appendix B. priate device (Vn). 4. Read and record the indicated value of the neck 6.1 GRAVIMETRIC CALIBRATION OF NECK scale (2). SCALE TEST MEASURES Calculate the neck-scale correction factor, k. a. Inspect the test measure for damage, rust, and internal cleanliness. Vn b. Exercise the balance (mass comparator) several times to k = ------------------- - ( h1 Ð h2 ) ensure smooth operation. c. Test the balance with the appropriate test weights to assure where the balance response is within tolerance. If out of tolerance, recalibrate the balance in mass units prior to proceeding with Vn = The volume of distilled water added, the calibration of the test measure. h1 = The indicated value of the scale reading (2), d. Measure and record the room air temperature, the atmo- spheric pressure, and the relative humidity. h2 = The indicated value of the scale reading (1). e. Calculate the air density, r (Tair), in kg/m3, using the o. Calculate the distilled water density from the Kell Equa- formula: tion (see Appendix F). 2 2 3 4 5 464.56P Ð U { 4.47 Ð 1.8504 ( T air ) + 00.085594 ( T air ) } a + bT w + cT w + dT w + eT w + f T w r ( T air ) = -------------------------------------------------------------------------------------------------------------------------------------- 3 - r ( T w ) = ----------------------------------------------------------------------------------------- kg/m3 - { ( T air ) + 273.16 } ´ 10 1 + gT wCOPYRIGHT 2000 American Petroleum InstituteInformation Handling Services, 2000
    • SECTION 7—FIELD STANDARD TEST MEASURES 9 p. Calculate the contained volume of the test measure at the above. The slicker-plate test measure is Þlled such that the temperature of the distilled water using the equation: water extends above the top of the neck of the measure due to surface tension and the excess is sheared off by sliding a m f Ð me transparent plate across the top of the neck making, V contain ( T w ) = ------------------------------------ + h (m3) - r ( T w ) Ð r ( T air ) h º dh º 0 ( º is deÞned as Òabsolutely equivalent toÓ), where h = The deviation of the location of the meniscus from zero with the appropriate sign applied, mf = The mass of the test measure Þlled with dis- tilled water, dh = One tenth of the least division of the neck scale, read with a magniÞer Þtted with an anti-paral- me = The mass of the clean, empty and dry test lax device. measure, Transparency of the slicker-plate enables visual inspec- r (Tw) = The density of the distilled water, tion for air voids under the plate, which must not be allowed to occur. r (Tair) = The density of the air, The equations for the calculation of uncertainty in the cali- h = The deviation of the location of the meniscus bration of neck-scale test measures (Appendix A) are also from zero with the appropriate algebraic sign applicable to slicker-plate test measures with h º dh º 0 . applied. Table 4 in Appendix B lists the uncertainty for a typical 5-gallon slicker-plate test measure. The uncertainty deter- q. Calculate the delivered volume of the test measure at the mined for a 5-gallon neck-scale test measure is normally temperature of the water using the equation: more than 4 times that of a 5-gallon slicker-plate test mea- sure. This is due to the uncertainty in the neck scale read- m f Ð md ing and is shown in detail in Tables 3 and 4 contained in V delivered ( T w ) = ------------------------------------ + h (m3) - r ( T w ) Ð r ( T air ) Appendix B. where 6.3 VOLUMETRIC CALIBRATION OF NECK SCALE AND SLICKER-PLATE TEST MEASURES md = The mass of the drained test measure. Calibration is achieved by the volumetric transfer of a known volume of water from a standard test measure into the r. Calculate the volume of the test measure at the desired ref- test measure of unknown volume (test measure being cali- erence temperature using the equation: brated), and calculating either the contained or delivered vol- ume of the unknown test measure. V cal ( T b ) = V cal ( T ) [ 1 Ð b t ( T Ð T b ) ] (m3) Ideally, it is preferred to have a platform elevator and large storage tank for distilled water. The calibration can then be where performed by the following method: Vcal(T) = The volume of the test measure calibrated a. Select a standard test measure, designated (U), of known either to contain or to deliver, delivery volume at a speciÞed reference temperature, scale graduation, and known cubical coefÞcient of thermal expan- T = The temperature of the distilled water, sion, ( a ) . The standard test measure can be placed on an elevator, leveled, and raised to an appropriate height. Tb = The standard reference temperature (60¡F or b. Place the test measure to be calibrated, designated (Z), 15¡C), below the standard test measure and level. b t = The volume coefÞcient of thermal expansion c. If the test measure is to be calibrated Òto contain,Ó then its for the test measure. interior must be dry. If the test measure is to be calibrated Òto deliverÓ then both the standard test measure and the measure to be calibrated must be wet. They are wetted by Þlling the 6.2 GRAVIMETRIC CALIBRATION OF SLICKER- standard test measure and then draining it into the measure to PLATE TEST MEASURES be calibrated with a 30-second draining time of the standard The calibration of a slicker-plate test measure by the gravi- test measure. Then drain the test measure under calibration in metric method differs from that of the neck-scale type only in the same way. This process is only to wet the surfaces and the way the measure is Þlled with distilled water, step h deÞne the amount of clingage.COPYRIGHT 2000 American Petroleum InstituteInformation Handling Services, 2000
    • 10 API CHAPTER 4—PROVING SYSTEMS d. Fill the standard test measure, U, to any point on the neck This expression can be solved for Z60, which is the vol- scale, LA, with distilled water from the storage. Record the ume required. This can be either a Òto containÓ or a Òto water temperature, TA. Read the meniscus scale and record. deliverÓ volume. e. Drain the standard test measure while ensuring no loss of water into the test measure to be calibrated. Close the drain on U 60 [ 1 + a ( T A Ð T b ) ] the standard test measure after draining for the prescribed time. Z 60 = ------------------------------------------------ - rq [ 1 + b ( T q Ð T b ) ] f. Read the meniscus scale reading in the test measure being calibrated. Record the neck scale reading, Lq, and the water The standard test measure, U60, has a known volume at the temperature, Tq. zero graduation on the neck scale, Lo, The difference in vol- g. In situations where the standard test measure is smaller ume, D A, between Lo and LA may be calculated by knowl- than test measure being calibrated, steps cÐf will have to be edge of the neck calibration constant. The numerical value of repeated the appropriate number of times, each time draining D A is used in the calculation of Z60. the standard test measure for the speciÞed time. h. After one complete calibration or ÒrunÓ is completed, additional runs may be performed. r A { U 60 [ 1 + a ( T A Ð T b ) ] + D A } i. A neck calibration as described in ÒGravimetric Cali- Z 60 = ------------------------------------------------------------------------- - Pq [ 1 + b ( T q Ð T b ) ] brationÓ is performed. On test measures having dual scale plates, denote whether one scale plate or both scale plates have been calibrated. 7 Inspection Field Standard Test Measure volumes are always refer- 7.1 GENERAL enced to standard temperature, i.e. either 60¡F or 15¡C. For one transfer of the standard test measure, U, to cali- Measurement activities often include the inspection or brate a test measure, Z. examination of test measures. Inspections or examinations are most often required when a new test measure is received from the manufacturer. M ----- = U 60 [ 1 + a ( T A Ð T b ) ] rA 7.2 DOCUMENTATION Documentation shall be available to all persons who have M ---- = Z 60 [ 1 + b ( T q Ð T b ) ] - custody transfer interests in the test measure. This paperwork rq shall include the manufacturerÕs identiÞcation of the construc- tion material, together with a statement of the primary calibra- where tion. All subsequent records of calibrations along with the control charts shall be maintained. Detail drawings, interior- r A = Density of water in the Standard Test Measure, coating identiÞcation (if applicable), gauge-glass sizes, and all other relevant documents, shall be sustained on Þle for exami- r q = Density of the water in the Test Measure to be nation when required. Calibrated, M = The same mass of water transferred from the 7.3 VISUAL INSPECTION standard test measure U60 into the test measure A visual inspection of any Þeld standard test measure shall to be calibrated Z60, be made before each use to ascertain that the capacity has not been altered by dents, internal corrosion or surface deposits. a = Cubical coefÞcient of expansion/¡F of the stan- In addition inspect the test measure carefully to make sure it dard test measure, U, is free of rust, broken seals, broken gauge glasses or scales, broken or missing levels, leaks or defective drain valves. The b = Cubical coefÞcient of expansion/¡F of the test effects of internal deposits on the calibrated volume of a test measure to be calibrated, Z, measure are shown in Table 8. Tb = Reference temperature, either 60¡F or 15¡C. Visual inspection shall include the following: a. An examination of all surfaces that affect volume to Since the two masses of water are the same: ensure that they are free from dents. Any minor dents that are considered acceptable must be identiÞed on the certiÞ- Z 60 [ 1 + b ( T q Ð T b ) ] = U 60 [ 1 + a ( T a Ð T b ) ] cate of calibration.COPYRIGHT 2000 American Petroleum InstituteInformation Handling Services, 2000
    • SECTION 7—FIELD STANDARD TEST MEASURES 11 Table 8—Volume Errors Due to Test Noninvertible test measures must be equipped with a Measure Internal Deposits Þxed anti-swirl plate to eliminate the formation of a vortex during draining. Errors Due to 0.0001 inch Test Measure Size Internal Deposit Minus (Ð) The neck on a test measure shall be uniformly cylindrical in Gallons Percentage of Total Volume in length and regular in diameter. 1 0.0094 The scale must be of corrosion-resistant metal, Þrm, secure, 5 0.0053 and easily adjustable. A provision must exist for afÞxing a 10 0.0042 lead-and-wire seal to provide a means for detecting unautho- 25 0.0032 rized adjustment. The scale divisions or graduations must be 50 0.0023 linear. The scale length must be appropriate to the test mea- 100 0.0018 sure. Applicable volume units (cubic inches, cubic milliliters, 200 0.0013 gallons, liters, or others) must be clearly indicated, and scale 500 0.0012 markings must be legible. b. A veriÞcation that noninvertible test measures have a rigid, The gauge glass must be clean and clear after wetting (that sloping drain line. The drain line must be equipped with a suit- is, no droplets should be present), and it must be capable of able drain valve and provide the capability to detect leaks. being removed, cleaned, and replaced. c. A veriÞcation that noninvertible test measures are The top surface of the neck of a test measure must be equipped with two adjustable spirit levels mounted at right ground, machined, or smoothly formed to serve as a level angles to each other on the upper cone or equivalent equip- benchmark. This surface shall be the primary level indication ment. The levels must be a shielded style and of high quality, in two axial directions. or provided with a protective cover and have adjusting screws Any test measure that is normally transported to various to permit leveling. Adjusting screws should allow a lead-and- locations shall be protected. A case, shipping container, or wire seal to be installed by the calibrating authority. other means that sufÞciently protects the test measure against dents and/or scale damage during storage or transportation d. An examination of the surface Þnish to determine that it is shall be used. Test measures mounted and moved on trailers clean and free from mill scale, grease, or other contaminants. shall be secured to prevent movement or damage during travel. If the exterior surface is painted, the paint coating must be reasonably free from scratches and corrosion damage. 7.4 CLEANING PROCEDURES e. An examination of welding quality to ensure that smooth, full-penetration welds are provided. All test measures shall be inspected and cleaned prior to f. If NIST Handbook 105-3 is the speciÞcation used, veriÞ- calibration, unless clean water was used as the calibration cation must indicate that each test measure bears in a ßuid and the test measure was cleaned, dried, sealed, and put conspicuous place the name or trade mark of the manufac- into storage at the completion of the previous calibration. turer, the nominal volume (in gallons, cubic inches, liters, or Prior to any cleaning of a test measure, it should be exam- other units), and a serial or other identiÞcation number. The ined for any signs of damage as described in the inspection material from which the standard is constructed shall be iden- section. Normal cleaning of the interior of the test measure tiÞed together with the cubical coefÞcient of thermal involves scrubbing with a biodegradable detergent and water. expansion per ¡F or ¡C for that material. However, if the interior of the test measure contains oil resi- Interior joints and seams shall be smooth and uniform. Sur- due then it may be necessary to use solvents for cleaning prior faces, including joints and seams, must be clean and free to cleaning with detergents. from grease, dirt, or oil Þlm. Surfaces must be smooth and In the event a test measure is heavily contaminated with oil free from rust corrosion. Potential air or water traps, resulting residues the additional step of steam cleaning the interior of from either design or damage, are not permitted. the test measure prior to any solvent cleaning or detergent Prolonged, and sometimes, even only isolated use of con- washing will be required. taminated water in a test measure will cause corrosive dam- After the above cleaning, each test measure should be Þlled age, pitting, and/or deposits to adhere to the interior surfaces. with water and allowed to stand for several minutes. During The interior of test measures should never be exposed to salt this time, a careful examination for leaks can be made. Once water or any type of water with high dissolved solids. this inspection is made, the test measure should be rinsed with If coating material is used inside test measures then it must distilled water, then rinsed with alcohol and allowed to dry. be uniformly applied to the surfaces and be free from any Smaller test measures, without leveling feet, whose level is voids or bubbles. Any coating material used, such as epoxy or determined by the plane of their base, should sit on a level bed- phenolic, must be resistant to the effects of alcohol, acetone, plate and be checked for Þrm seating. A vessel that rocks will benzene, petroleum products, and water. not give a true meniscus reading during its calibration.COPYRIGHT 2000 American Petroleum InstituteInformation Handling Services, 2000
    • 12 API CHAPTER 4—PROVING SYSTEMS 7.5 INTEGRITY lating the Base Volume of a Displacement or Tank Prover, using Þeld standard test measures, is described in API MPMS, In addition to the initial testing a test measure undergoes Chapter 12.2.4, ÒCalculation of Base Prover Volumes by the when it is new, it should also be checked periodically to ver- Waterdraw Method.Ó ify its leak integrity. The following systematic procedure is Different techniques may be used to calibrate meter prov- recommended: ers using Þeld standard test measures. Any of the following a. The test measure should be Þlled with warm-to-hot water methods can be used; however, normal operating practice 100Ð140¡F (38Ð60¡C) and allowed to stand for 30Ð60 min- currently uses Method 3. utes, making certain that any thermometer installed will not 1. Fill each test measure to its exact certiÞed (zero) be damaged by exceeding its range. All seams, joints, pipe Þt- capacity, and allow the Þnal water level to be read on com- tings, and gauge glass along with the overall test measure pletion in the last test measure Þlled. should be checked for leaks. The drain valve should be 2. Slightly overÞll each test measure and then bring the checked for leaks and air entrapment. The valve should be level back to the exact capacity (zero) by withdrawing opened and closed several times to verify positive sealing of some of the liquid. The liquid that is withdrawn is then the valve. An optional procedure involves taking and record- released into the next test measure to be Þlled. ing a level reading prior to cracking the drain valve open and 3. With graduated neck test measures it is not necessary drawing off approximately 1 gallon of water into a wetted test to operate at the zero level. Therefore, the test measure measure and returning it to the prover. If the level in the test may be Þlled to any location on its scale, the liquid level measure is lower, either the piping ahead of the valve con- read, and its certiÞed capacity is then adjusted mathemati- tained air or some part of the valve body cavity that was cally using a plus or minus scale reading (SR). A minus previously Þlled with air is now Þlled with water. signiÞes that the water level is below the certiÞed capacity b. The test measure should be drained to observe the effec- (zero mark) on the test measure scale, and a plus indicates tiveness of the anti-swirl plate while the ßuid is draining. that the water level is above the zero mark on the scale. c. The test measure should be Þlled with the calibrating medium, and the checks listed above should be repeated. 8.2 NORMAL TEST MEASURE OPERATION d. The thermometers used with the test measure should be routinely subjected to a calibration or a comparison with a Setting up a test measure for calibration use in the Þeld standard reference thermometer to verify accuracy. normally involves the following preparatory steps. Inspect all test measures to be used in the calibration for cleanliness, 8 Operation And Use dents, unbroken sight glasses, scales and seals. Following the inspection, all the test measures shall be leveled while they The primary use of Þeld standard test measures is to deter- are in a water-Þlled condition, across at least two axes, 90¡ mine the volume of a meter prover when using the waterdraw apart. After this Þlling and leveling, the test measure shall be method of calibration. Test measures are constructed of stain- leak tested. If free of leaks, draining of the test measures less steel in a multitude of sizes, ranging from 1 gallon all the should now take place, until cessation of the main ßow allows way up to 1,500 gallons, with many different intermediate the draining time (as speciÞed on the calibration certiÞcate) to sizes. In fact, a test measure may be constructed in any conve- be followed and a repeatable clingage condition established. nient size, and frequently high-sensitivity test measures are After draining for the prescribed draining time, the bottom built to accommodate the exact volume of a small volume drain valve is closed or the test measure is returned to its prover. Some examples of unusual test measures sizes in reg- upright and level position to prepare the test measure for cali- ular use are 15 gallon, 21 gallon, 42 gallon, 225 gallon, and bration use. 227 gallon. Equivalent volume or different volume test mea- During a calibration run, the test measure is Þlled with sure sizes are also available in metric units. Only test mea- water to an upper scale reading, which is then recorded as a sures calibrated with a Òto deliverÓ volume shall be used in (+) or (Ð) volume, depending on whether the reading is above the calibration of meter provers. or below the zero line on the scale. Typically, most volumes are read as either cubic inches (in.3) or milliliters (ml) 8.1 FIELD USE OF VOLUMETRIC TEST depending on the calibration units of the test measure. Once MEASURES the test measure is Þlled, the leveling veriÞed, and the scale Field standard test measures are used in the waterdraw cal- reading recorded, the temperature of the water in the test ibration of pipe provers, small volume provers, and tank prov- measure is then required. This temperature can be taken by ers. Full descriptions on the Þeld use of these test measures different methods and in different locations. The temperature will be found in API MPMS, Chapter 4.9.1, ÒDetermination can be taken, while the test measure still contains the water of the Volume of Displacement and Tank Provers by the following the scale reading, by immersing a thermometer Waterdraw Method of Calibration.Ó The procedure for calcu- inside the test measure or by holding a thermometer in theCOPYRIGHT 2000 American Petroleum InstituteInformation Handling Services, 2000
    • SECTION 7—FIELD STANDARD TEST MEASURES 13 ßowing stream while the water is draining from the test mea- 100- or the 50-gallon test measure, with 5 gallons of water sure, after the scale reading. At the cessation of the main ßow, from the 5-gallon test measure and then Þll the remainder of it is essential that the draining time is carefully and exactly this test measure from the prover. followed to only allow the correct amount of water to escape. The 100-gallon test measure for Fill No. 1 has a base vol- This will restore the test measure to its ready-to-Þll-again ume of 23100 in.3. The 50-gallon test measure for Fill No. 2 condition, ensuring that the water clingage remaining inside has a base volume of 11550 in.3. The pre-Þll 5-gallon test the test measure is maintained each time as a repeatable quan- measure has a base volume of 1155 in.3. tity, and replicates the drainage time sustained by the calibrat- If only the 100-gallon and the 50-gallon test measures are ing agency. used, at the end of the pass the water level in the last test mea- sure Þlled will not reach the neck, and therefore, will not have 8.3 IRREGULAR TEST MEASURE OPERATIONS a scale reading. In this instance a pre-Þll is used to pre-load the In Þeld use, sometimes irregular operating conditions can Þrst measure Þlled with enough water to enable readings in the arise while using test measures in prover calibrations. Two of sight glasses on all the test measures Þlled to be achieved. these conditions are identiÞed as either requiring that a test Treat the pre-Þll volume as a separate Þeld standard test measure be overÞlled or underÞlled during the calibration measure Þlling, but with both the Base Volume of the Test cycle. If either one of these two conditions should arise dur- Measure (BMV) and the Scale Reading (SR) handled in a neg- ing a prover calibration, the techniques described below can ative manner. be used to solve the deÞciency. Fill the 5-gallon test measure with wastewater and take the Scale Reading (SR). The temperature is taken by immersion, 8.3.1 Test Measure Pre-Fill after reading and recording the SR. Then drain the 5-gallon measure into the 100-gallon measure using the prescribed During a calibration, it is sometimes necessary to accu- drain time. In this example, SR on the 5-gallon test measure is rately determine the volume of a partially Þlled test measure. This determination can be made by a method known as pre- (-10). Þlling. Pre-Þlling is accomplished by Þrst Þlling a larger test Fill No. 1, of the 100-gallon test measure has a SR of (+20) measure with an amount of water taken from a smaller vol- in.3. Temperature is taken, while draining, after reading and ume test measure. This will bring the water being drawn from recording the scale. the prover into the test measure to a level that can be read on Fill No. 2, of the 50-gallon test measure has a SR of (-6) the gauge glass scale. in.3. Temperature is taken, while draining, after reading and As an example, consider a prover calibration with an recording the scale, (see below). approximate one-way volume of 145 gallons. To accomplish where the volume determination, the only test measures available are of a 100-, 50-, and 5-gallon capacity. One method of cali- CTDW = The correction for the difference in density brating this prover would be to Þll the 100-gallon test mea- between the water in the prover and the water in sure one time and the 5-gallon test measure nine times. This the test measure, would not be recommended due to the large number of test measure Þllings required, using a 5-gallon test measure, CCTS = The combined correction factor for the effect of which normally has a large uncertainty value in its calibra- temperature on the steel of the prover and the tion. A more practical solution would be to pre-Þll either the test measure, Pre-Þll BMV = 1155 ÉTreated as a negative: BMV = Ð1155 Pre-Þll SR = Ð10 ÉTreated as a negative: SR = +10 To determine the adjusted Base Volume of the Test Measure (BMVa): Pre-Þll: BMV + SR = BMVa Example: Ð1155 + (+10) = Ð1145 Fill No. 1: BMV + SR = BMVa Example: 23100 + (+20 ) = +23120 Fill No. 2: BMV + SR = BMVa Example: 11550 + (Ð6) = +11544 TOTAL VOLUME (145.10 gals) 33519 in.3 Calculating the Pre-Þll volume the same way as any other test measure is calculated: Calculate Fill No. 1: 23120 x CTDW x CTS = WD Éfor Fill No. 1 Calculate Fill No. 2: 11544 x CTDW x CCTS = WD Éfor Fill No. 2 Calculate Pre-Þll: Ð1145 x CTDWx CCTS = WD Éfor Pre-ÞllCOPYRIGHT 2000 American Petroleum InstituteInformation Handling Services, 2000
    • 14 API CHAPTER 4—PROVING SYSTEMS WD = The Base Volume of the Test Measure adjusted and shuts down the prover calibration run. Take the closing for the scale reading, SR, and corrected for the scale reading: effects of CTDW and CCTS. SR (closing) = + 215 in.3 8.3.2 Test Measure Neck Draw Another unusual operating condition that can arise with Treat this neck Þll as if it were a separate Þeld standard test test measure use is the required controlled overÞlling of test measure with a BMV = zero (0). measures during a prover calibration run. In this case, the The temperature is taken by immersion, of the neck portion problem is that additional water needs to be contained in the only, after reading and recording the closing SR. already-full test measure. This is a situation where a neck To rationalize the Scale Reading: drawdown (neck-Þll) procedure would be used and examples (SR) = [SR (closing) ÐSR (opening)] of this situation are described in the text below. = +215 Ð (Ð220) As an example, consider a prover calibration with an = +215 + (220) approximate one-way volume of 153 gallons. To accomplish the volume determination, the only test measures we have = + 435 in.3 available are of a 100- and 50-gallon capacity. The total capacity of the combined Þlling of these two test measures To determine BMVa: (see below) would range from a minimum volume of 148.5 gallons to a maximum volume of 151.5 gallons. Similar situations can often occur in the calibration of new The 100-gallon test measure for Fill No. 1 has a base vol- provers, or also when provers have been modiÞed or worked ume of 23100 in.3. The 50-gallon test measure for Fill No. 2 on, such that the volume is not exactly known. Therefore, the has a base volume of 11550 in.3. Þrst calibration run is very often a guess as to where the actual It has been determined beforehand that after Þlling both Þnal volume will Þnish, relative to the test measures being measures to their maximum readable scale levels there will used to determine the volume. In this situation, it often hap- still be approximately 1.5 gallons of water remaining in the pens that the operator can Þnd himself having to perform sev- prover. This volume of water will somehow need to be eral neck draws to complete the calibration run, just because accommodated in a test measure, so as to be measured. of the fact that this prover volume is not precisely known. Use Fill No. 1, of the 100-gallon test measure has a SR of (+230) of this method will allow a precise volume to be decided and in.3. Temperature is taken, by immersion, after reading and enable the operator to reÞne the test measure Þllings for the recording the scale. additional calibration runs required to be made. Fill No. 2, of a 50-gallon test measure has a SR of (+100) in.3. Temperature is taken, while draining, after reading and 8.3.3 Test Measure Pre-Fill and Neck Draw recording the scale. Neck Draw: Lower the water level in the neck of the 100- It is also possible to have a situation where a test measure gallon test measure, to waste, by careful manipulation of the pre-Þll and a test measure neck draw are both necessary dur- drain valve, until the water level reaches the lowest readable ing the same prover calibration run. Although this situation is value on the scale. Close the drain valve and take the scale uncommon, operators should be prepared for it, should this reading. This value is recorded as the opening scale reading. condition arise in a calibration. Following the previous examples, consider a prover calibra- SR (opening) = Ð220 in.3 tion with an approximate one-way volume of 147.5 gallons. To accomplish the volume determination, the only test mea- Draw water from the prover reÞlling the neck of the sures that are available are the following: 100-, 50-, and 5-gal- 100-gallon test measure until the detector switch activates lon capacity. Therefore, to perform the prover calibration with Fill No. 1: BMV + SR = BMVa Example: 23100 + (+230) = +23330 Fill No. 2: BMV + SR = BMVa Example: 11550 + (+100) = +11650 Neck Draw: BMV + SR = BMVa Example: zero + (+435) = +435 TOTAL VOLUME (153.31 gals) 35,415 in.3 Calculate the Neck Fill as any other measure Þll is calculated. Calculate Fill No. 1: 23330 x CTDW x CCTS = WD Éfor Fill No. 1 Calculate Fill No. 2: 11650 x CTDW x CCTS = WD Éfor Fill No. 2 Calculate Neck Fill: 435 x CTDW x CCTS = WD É for Neck DrawCOPYRIGHT 2000 American Petroleum InstituteInformation Handling Services, 2000
    • SECTION 7—FIELD STANDARD TEST MEASURES 15 these test measures would require the following sequence of Therefore, with both test measures Þlled, and a pre-Þll of 5 events: gallons, a total amount of 146.5 gallons of water has been Fill the 100-gallon test measure with a 5-gallon water pre- held. However, 147.5 gallons need to be contained and room Þll from the 5-gallon test measure, then Þll the test measure in a test measure is needed for an additional one gallon of up to the top of the readable scale with water drawn from the water. prover. Next, Þll the 50-gallon test measure to the top of its At this point, it is necessary to draw down the neck of the readable scale with water draw water. At this point, the fol- 100-gallon test measure. Drawing the water level down to the lowing situation ocurs: lowest readable scale line will make a total volume space The volume in the 100-gallon test measure is 101 gallons available in the 100-gallon test measure for approximately an from which 5 gallons need to be subtracted. The volume in additional 2 gallons and allow the prover calibration run to be the 50-gallon test measure is 50.5 gallons. The total volume completed. equals (101 + 50.5Ð5) = 146.5 gallons.COPYRIGHT 2000 American Petroleum InstituteInformation Handling Services, 2000
    • 16 API CHAPTER 4—PROVING SYSTEMS Gauge scale Glass plate Gauge glass Gauge scale Sight tube Figure 1—Various Types of Standard Test Measures (I)COPYRIGHT 2000 American Petroleum InstituteInformation Handling Services, 2000
    • SECTION 7—FIELD STANDARD TEST MEASURES 17 Slicker Plate Test Measure 35¡ Brim Measure Glass tube with scale Window Protector Figure 2—Various Types of Standard Test Measures (II)COPYRIGHT 2000 American Petroleum InstituteInformation Handling Services, 2000
    • 18 API CHAPTER 4—PROVING SYSTEMS 1. Reinforcing bar 2. Handle (raised) 3. Rolled bead 4. Gauge assembly 3 5. Gauge mounting 6. Concave bottom in3 25 2 20 5 US GAL 15 10 5 4 0 5 DELIVERS 10 15 20 25 5 35¡ 1 6 Figure 3—Field Standard Test Measure—Invertible TypeCOPYRIGHT 2000 American Petroleum InstituteInformation Handling Services, 2000
    • SECTION 7—FIELD STANDARD TEST MEASURES 19 1. Drain valve 6 2. Drain slope 5¡ 3. Levels 5 4. Level cover 5. Gauge mounting 6. Rolled bead 7. Top cone pitch 25¡ 8. Reinforcing bands 9. Bottom cone pitch 20¡ 7 10. Adjustable legs 4 3 8 2 1 9 10 Figure 4—Field Standard Test Measure—Bottom Drain TypeCOPYRIGHT 2000 American Petroleum InstituteInformation Handling Services, 2000
    • 20 API CHAPTER 4—PROVING SYSTEMS ,,,,,,,, ,, ,,,,,,,, ,,,, ,,,, ,, ,,,,,,,, ,, ,,,,,,,, ,,,, ,,,, ,, ,,,,,,,,, ,,,,,,,, ,,,, ,,,, ,,,,,,,,, ,,,,,,,, ,,,, ,,,, ,,,,,,,,, ,,,,,,,, ,,,,,,,,, ,,,,,,,, ,,,, ,,,, ,,,,,,,,, ,,,,,,,, ,,,, , ,,,, ,, XX ,,,,,,,,, ,,,,,,,, ,,,, ,, , ,,,, ,,, ,, ,,,,,,,,, ,,,,,,,, 25 20 15 5 US GALLONS 10 5 0 0 DELIVERS 5 10 15 20 25 in3 Figure 5—Gauge Glass and Scale AssemblyCOPYRIGHT 2000 American Petroleum InstituteInformation Handling Services, 2000
    • CONTROL CHART 5 Gallon Slicker Plate Test Measure Serial No:#123456. Owner: ABC Oil Co. 4 ,99 9 Figure 6—Field Standard Test Measure Control Chart T o l e r a n ce l i m i ts SECTION 7—FIELD STANDARD TEST MEASURES 4,9 98 .5 Acti o n l i m i ts Gallons, thousands W ar ning lim it s 4 ,99 8 C e n te r l i n e W ar ning lim it s Acti o n l i m i ts 4,9 97 .5 Toler anc e lim it s 4 ,99 7 1940 1950 1960 1970 1980 1990 2000 Year 21COPYRIGHT 2000 American Petroleum InstituteInformation Handling Services, 2000
    • COPYRIGHT 2000 American Petroleum InstituteInformation Handling Services, 2000
    • APPENDIX A—ACCURACY REQUIREMENTS FOR VOLUMETRIC TEST MEASURES In determining the accuracy requirements in the calibration Shown below are the uncertainty requirements for volume of test measures, it is necessary to consider the hierarchy of measurements in the normal petroleum measurement hierar- petroleum custody transfer measurements so that the preci- chy, see Table A2. The uncertainties versus test measure size sion levels of test measures are consistent with other preci- as shown in the table are appropriate to the petroleum indus- sion levels of measurement. The conventional hierarchy in try convention for meter provers. petroleum measurement is shown in Table A1. No recommendations are made for uncertainty limits for If, however, the master meter calibration techniques are small volume provers calibrated by master meter/prover pro- introduced then the number of hierarchy levels will be cedures. For small volume provers, lower uncertainty limits increased to seven (see Table A6). Similarly, should a state are needed for test measures used in their calibration since smaller prover and test measure volumes are used at the same agency or calibration source other than NIST be used in the metering rate involving conventional provers. Recommenda- test measure calibration, the number of hierarchy levels will tions on uncertainty limits for test measures used for calibrat- be increased (see Table A8). ing small volume provers are given below, see Table A4. Potential errors or uncertainties of each position in the The use of small volume provers and master meter/prover hierarchy from the lowest to highest position must be pro- calibration of conventional provers dominates the uncertainty gressively lower so that overall uncertainty of the hierarchy limit capabilities needed for test measure calibration. The can be controlled. Uncertainties from the highest to the low- uncertainty limits shown in the table below are the recom- est levels progressively add to each successive level. Each mended levels that can be achieved by NIST, see Table A3. step in the hierarchy should normally experience uncertain- If master meter calibration of meter provers is introduced ties that are 25 to 50% of the uncertainty at the next lowest into the petroleum hierarchy, as in the case of proving a mas- level in the hierarchy. For measurements that are somewhat ter meter with a master prover and then using the master repetitious in nature, the margin between adjacent steps in the meter to calibrate a Þeld prover. The number of levels in the hierarchy can be less because repeated measurements propa- hierarchy is increased to seven as follows, (see Table A7): gate the uncertainty on the overall average to a lower value. Table A1—Hierarchy of Measurements for the Metered Volumes of Petroleum Hierarchy Position Measurement Description 1. Highest Calibration of NIST Standards 2. Calibration of Test Measures 3. Calibration of Meter Prover 4. Proving of Custody Transfer Meter 5. Lowest Custody Transfer Meter Registration Table A2—Uncertainty Requirements for a Petroleum Measurement Hierarchy Using a Single Custody Transfer Meter and the Waterdraw Calibration of a Displacement Prover Overall Uncertainty Limits % Hierarchy Measurement Low Medium High Position Description Accuracy Accuracy Accuracy 1. Highest Calibration of NIST Stds 0.050 0.020 0.010 2. Calibration of Test Measures 0.100 0.050 0.020 3. Calibration of Meter Prover 0.200 0.100 0.050 4. Proving of Custody 0.350 0.150 0.075 Transfer Meter 5. Lowest Custody Transfer 0.500 0.250 0.100 Meter Registration 23COPYRIGHT 2000 American Petroleum InstituteInformation Handling Services, 2000
    • 24 API CHAPTER 4—PROVING SYSTEMS Table A3—Uncertainty Limits for Calibration of Normal Sensitivity Test Measures as Used in the Calibration of Conventional Displacement Provers Size of Test Measure, Gallons Uncertainty Limit% 1 0.030 5 0.020 10 0.010 25 0.010 50 0.005 100 0.005 200 0.005 500 0.005 Table A4—Uncertainty Limits for the Calibration of High Sensitivity Test Measures as Used in the Calibration of Small Volume Provers Size of Test Measure, Gallons Uncertainty Limit% 1 0.030 5 0.020 10 0.010 25 0.010 50 0.010 100 0.010 Table A5—Uncertainty Limits for the Calibration of Test Measures Used for Displacement Provers Overall Uncertainty Limits % With Master Meter Without Master Meter Size of Test Measure, Gallons Prover Calibration Prover Calibration 1 0.025 0.050 5 0.015 0.035 10 0.010 0.025 25 0.010 0.020 50 0.008 0.015 100 0.005 0.010 200 0.005 0.010 500 0.005 0.010 Table A6—Hierarchy of Petroleum Metered Volume Measurements Including Calibration of Meter Provers by a Master Meter Hierarchy Position Measurement Description 1. Highest Calibration of NIST Standards 2. Calibration of Test Measures 3. Calibration of Master Prover 4. Calibration of Master Meter 5. Calibration of Meter Prover 6. Proving of Custody Transfer Meter 7. Lowest Custody Transfer Meter RegistrationCOPYRIGHT 2000 American Petroleum InstituteInformation Handling Services, 2000
    • SECTION 7—FIELD STANDARD TEST MEASURES 25 Table A7—Uncertainty Requirements for a Petroleum Measurement Hierarchy Including a Single Custody Transfer Meter With Master Meter Prover Calibration Hierarchy Measurement Low Medium High Position Description Accuracy Accuracy Accuracy 1. Highest Calibration of NIST Standards 0.010 0.005 0.0025 2. Calibration of Test Measures 0.025 0.010 0.005 3. Calibration of Master Prover 0.050 0.020 0.010 4. Calibration of Master Meter 0.100 0.050 0.020 5. Calibration of Meter Prover 0.200 0.100 0.050 6. Proving of Custody 0.350 0.150 0.075 Transfer Meter 7. Lowest Custody Transfer 0.500 0.250 0.100 Meter Registration The extreme case of total expansion of the Petroleum Measurement Hierarchy is shown below: Table A8—Total Hierarchy of Measurements of Metered Volumes of Petroleum Showing International Standards, Calibration of Test Measures other than by NIST and Meter Prover Calibration by a Master Meter Hierarchy Position Measurement Description 1. Highest International Base Standard Units 2. Calibration of NIST Standards 3. Calibration of Other Body Standards 4. Calibration of Test Measures 5. Calibration of Master Prover 6. Calibration of Master Meter 7. Calibration of Meter Prover 8. Proving of Custody Transfer Meter 9. Lowest Custody Transfer Meter RegistrationCOPYRIGHT 2000 American Petroleum InstituteInformation Handling Services, 2000
    • 26 API CHAPTER 4—PROVING SYSTEMS International Base Standard Units Calibration of NIST Standards Calibration of Other Calibration Agency Standards Calibration of Field Standard Calibration of Field Standard Calibration of Field Standard Test Measures Test Measures Test Measures Calibration of Field Prover by Calibration of Master Prover Calibration of Master Prover Waterdraw Method by Waterdraw Method by Waterdraw Method Calibration of Master Meter Calibration of Master Meter Calibration of Field Prover by Calibration of Field Prover by Master Meter Method Master Meter Method Proving of Custody Transfer Proving of Custody Transfer Proving of Custody Transfer Meter Meter Meter Custody Transfer Meter Custody Transfer Meter Custody Transfer Meter Registration Registration Registration Figure 7—Levels of the Petroleum Measurement HierarchyCOPYRIGHT 2000 American Petroleum InstituteInformation Handling Services, 2000
    • APPENDIX B—CALCULATION OF UNCERTAINTY OF A FIELD STANDARD TEST MEASURE While the contained volume (Tw) is the actual scientiÞc about the mean air density are known to rarely exceed 3%. value determined by NIST, test values of the delivered vol- Analysis indicates that modest accuracy in the required mea- ume and calculated values of volume (Tb), required by indus- surements produces a satisfactory uncertainty in the air den- try, are also provided by NIST. Accordingly, the equation for sity. For example, temperature measured within an accuracy the contained volume (below) must be subject to uncertainty of ±0.4¡C, atmospheric pressure within ±1.1 mm Hg, and rel- analysis. ative humidity within ±16 %, will result in a contribution to the uncertainty of the above equation on the order of one part m f Ð me per million (1 ppm). V contain T w = ------------------------------------ h m3 -+ r ( T w ) Ð r ( T air ) It is convenient to make a change in notation at this point, The above equation contains the expression r (Tw) which let V = Vcontain(Tw). is derived from the equation: The relative uncertainty in V may be expressed as: 2 3 4 5 a + bT w + cT w + dT w + eT w + fT w r ( T w ) = ---------------------------------------------------------------------------------------- kg/m3 - dV 1 ¶V 2 0.5 1 + gT w ------ = k S æ --- ------ d x iö - - - V è V ¶x i ø The equation is very unwieldy for the purposes of uncer- tainty analysis. To make the analysis simpler, the Þrst-order where approximation is used: xi = The measured variables in V, r ( T W ) = r O [ 1 Ð b W ( T W Ð T B ) ] kg/m3 k = The coverage factor, normally taken to be 2, consistent with NIST policy. where Tables 1Ð3 list typical calculated uncertainties for con- r o = The density of the distilled water at the refer- tained volumes at (Tw) for 100-, 50-, and 5-gallon Þeld stan- dard test measures, respectively. Values are listed in SI units. ence temperature, Tb, ÒGuidelines for Evaluating and Expressing the Uncertainty b w = The volumetric thermal expansion coefÞcient of NIST Measurement Results,Ó NIST Technical Note 1297, for water appropriate for Tb, suggests classifying the uncertainties for xi as: Type A: Uncertainties which are evaluated by statistical Tb = The reference temperature, either 60¡F or 15¡C. methods. Type B: Uncertainties which are evaluated by other means. While the accuracy of this equation is inferior to that of the Once a value for the uncertainty of an xi is determined, it full Kell density equation, it is extremely satisfactory for the receives the identical mathematical treatment in the equation purposes of uncertainty analysis. whether it is either Type A or Type B. The sources of the uncertainties for the xiÕs and their type are: dh is one-tenth of the least division of the neck scale read m f Ð me V contain ( T w ) = ------------------------------------ + h m3 - with a magniÞer Þtted with an anti-parallax device, Type B. r ( T w ) Ð r ( T air ) dmf and dme are calculated from: substituting: 1 ì ü--- 2 2 ï sm 1 ( m Ð m midrange ) ï r ( T w ) = r o [ 1 Ð b w ( T w Ð T b ) ] kg/m3 dm = í ---- 1 + -- + ----------------------------------------- - 2 - - ý ïb p S ( m i Ð m midrange ) 2 ï î þ m f Ð me V contain ( T w ) = ---------------------------------------------------------------------- + h m3 - r o [ 1 Ð b w ( T w Ð T b ) ] Ð r ( T air ) where Air density is a function of air temperature, atmospheric pres- sm = The standard deviation of the residuals of the sure and relative humidity. At a given altitude, ßuctuations comparator calibration equation, 27COPYRIGHT 2000 American Petroleum InstituteInformation Handling Services, 2000
    • 28 API CHAPTER 4—PROVING SYSTEMS b = The slope of the calibration equation, where p = The number of calibration measurements, b t = The volumetric coefÞcient of thermal expan- m = The mass of the test measure, sion for the test measure, mmidrange = The midpoint of the calibrated range of the Tb = The reference temperature of the test measure, comparator, typically 60¡F or 15¡C. mi = The mass value for which the calibrations were Since the volumetric coefÞcient of thermal expansion is not done. directly measured, common practice has been to use the ther- One would expect the uncertainties of the masses to be mal expansion coefÞcient for Series 304 stainless steel. The included in dm, but they are negligible compared to the stan- value used is 0.000048/¡C. Using this value for contained vol- dard deviation of the residuals, Type A. umes, the uncertainty due to the calculation using the above dr o and db w are derived from the Kell Density Formula, volume equation is ( T w Ð T b )db t where db t is 7 x 10 -7/¡C, Type B. which is to be added in quadrature to the appropriate uncer- dTw is based on the Standard Deviation from NIST Cali- tainty from the tables. bration Data, Type B. The uncertainty in applying the above volume equation to dr air is derived from A Primer for Mass Metrology, Jaeger the delivered volumes is compounded by the fact that when & Davis, NBS Publication 700-1. the temperature decreases from 23¡ to 15.56¡C, the viscosity Volume calibrations are normally done in a climate-con- of water increases by 21% and the surface tension increases trolled laboratory environment at a temperature around 23¡C. by 1.6%. These increases will have an effect on the way the The normal requirement from the petroleum industry is to water drains from the test measure. If less water drains from a convert volumes measured at normal room or ambient tem- given measure at 15.56¡C in the 30 seconds than from the peratures to a reference temperature, usually 60¡F or 15¡C, same measure at 23¡C in 30 seconds, then there is an uncor- via the formula: rected residual effect that will make it difÞcult to calculate the delivered volume at the lower temperature with any level of V ( T b ) = V ( T w ) [ 1 Ð bt ( T w Ð T b ) ] conÞdence. Table B1—Uncertainty for the Gravimetric Determination of the Contained Volume at Room Temperature of NIST’s 100-Gallon (0.379m3) Neck Scale Test Measure 1 ¶V 1 ¶V Ð6 --- ------ - - --- ------ dx i ´ 10 - - xi Value V ¶x i Value dxi V ¶ xi h Ñ 1/ 2.6/m3 3.3 x 10-6m3 8.6 V mf 492 kg 1/(mfÐme) 2.7 x 10-3/kg 2.2 x 10-3 kg 6.0 me 115 kg Ð1/(mfÐme) Ð2.7 x 10-3/kg 2.2 x 10-3 kg -6.0 ro 1000 kg/m3 Ð1/ r o Ð1 x 10-3m3/kg 4 x 10-3 kg/m3 -4.0 bw 2 x 10-4/ ¡C TwÐTref,w 21.5 ¡C 3.3 x 10-7/ ¡C 7.1 Tw 21.5 ¡C bw 1.5 x 10-4/ ¡C 2 x 10-2 ¡C 3.0 r air 1.18 kg/m3 1/ r o 1 x 10-3m3/kg 1 x 10-3 kg/m3 1.0 1 -- - 2 dV 2 ------ = 2 S æ --- ¶V dx iö = 0.0030 % - 1 - ------ - V è V ¶ xi øCOPYRIGHT 2000 American Petroleum InstituteInformation Handling Services, 2000
    • SECTION 7—FIELD STANDARD TEST MEASURES 29 Table B2—Uncertainty for the Gravimetric Determination of the Contained Volume at Room Temperature of NIST’s 50-Gallon (0.189m3) Neck Scale Test Measure 1 ¶V 1 ¶V Ð6 --- ------ - - --- ------ d x i ´ 10 - - xi Value V ¶x i Value dxi V ¶x i h Ñ 1/ 5.3/m3 1.6 x 10-6m3 8.5 V mf 254 kg 1/(mfÐme) 5.3 x 10-3/kg 2.2 x 10-3/kg 11.7 me 66 kg Ð1/(mfÐme) Ð5.3 x 10-3/kg 2.2 x 10-3 kg Ð11.7 ro 1000 kg/m3 Ð1/ r o Ð1 x 10-3 m3/kg 4 x 10-3 kg/m3 Ð4.0 bw 2 x 10-4/¡C TwÐTref,w 23.5 ¡C 3.3 x 10-7 /¡C 7.8 Tw 23.5 ¡C bw 1.5 x 10-4 /¡C 2 x 10-2 ¡C 3.0 r air 1.18 kg/m3 1/ r o 1 x 10-3 m3/kg 1 x 10-3 kg/m3 1.0 1 -- - 2 dV 2 ------ = 2 S æ --- ¶V d x iö = 0.0042% - 1 - ------ - V è V ¶x i ø Table B3—Uncertainty for the Gravimetric Determination of the Contained Volume at Room Temperature of NIST’s 5-Gallon (0.0189 m3) Neck Scale Test Measure 1 ¶V 1 ¶V Ð6 --- ------ - - --- ------ d x i ´ 10 - - xi Value V ¶x i Value dxi V ¶x i h Ñ 1/ 53/m3 1.6 x 10-6m3 84.8 V mf 23.6 kg 1/(mf Ðme) 5.3 x 10-2/kg 2.3 x 10-4 kg 12.2 me 4.8 kg Ð1/(mf Ðme) Ð5.3 x 10-2/kg 2.3 x 10-4 kg Ð12.2 ro 1000 kg/m3 Ð1/ r o Ð1 x 10-3 m3/kg 4 x 10-3 kg/m3 Ð4.0 bw 2 x 10-4/¡C TwÐTref,w 18¡C 3.3 x 10-7/¡C 6.0 Tw 18¡C bw 1.5 x 10-4/¡C 2 x 10-2 ¡C 3.0 r air 1.18 kg/m3 1/ r o 1 x 10-3 m3/kg 1 x 10-3 kg/m3 1.0 1 -- - 2 dV 1 ¶V 2 ------ = 2 S æ --- ------ dx iö - - - = 0.0174% V è V ¶x i øCOPYRIGHT 2000 American Petroleum InstituteInformation Handling Services, 2000
    • 30 API CHAPTER 4—PROVING SYSTEMS Table B4—Uncertainty for the Gravimetric Determination of the Contained Volume at Room Temperature of NIST’s 5-Gallon (0.0189 m3) Slicker-Plate Test Measure 1 ¶V 1 ¶V Ð6 --- ------ - - --- ------ d x i ´ 10 - - xi Value V ¶x i Value dxi V ¶x i h Ñ 1/ 53/m3 0 0 V mf 28.1 kg 1/(mfÐme) 5.3 x 10-2/kg 2.3 x 10-4 kg 12.2 me 9.3 kg 1/(mfÐme) Ð5.3 x 10-2/kg 2.3 x 10-4 kg Ð12.2 ro 1000 kg/m3 Ð1/ r o Ð1 x 10-3 kg/m3 4 x 10-3 kg/m3 Ð4.0 bw 2 x 10-4 /¡C TwÐTref,w 21.7 ¡C 3.3 x 10-7/¡C 7.2 Tw 21.7 ¡C bw 1.5 x 10-4/¡C 2 x 10-2 ¡C 3.0 r air 1.18 kg/m3 1/ r o 1 x 10-3 kg/m3 1 x 10-3 kg/m3 1.0 1 -- - dV 2 2 1 ¶V ------ = 2 S æ --- ------ dx iö = 0.0039 - V - - è V d xi øCOPYRIGHT 2000 American Petroleum InstituteInformation Handling Services, 2000
    • APPENDIX C—TEST MEASURE CONTROL CHARTS Every test measure shall have a data record prepared and maintained by the national calibrating agency, containing all the rele- vant information pertaining to the history of the test measure. The relevant information should contain: a. The identity of the test measure by owner and the ownerÕs number. b. The makerÕs name, identiÞcation number, nominal volume, scale divisions, coefÞcient of expansion of material of construc- tion, dates and details of all types of cleaning performed. c. Calibration dates, corresponding seal numbers, together with Òto containÓ and Òto deliverÓ volumes. d. Uncertainty history. The calibration history of all test measures shall be documented and recorded and a control chart developed for each test measure. An example of a Test Measure Control Chart is shown in Figure 6, which plots the calibrated volume against time for each cal- ibration performed, and shows the total documented calibration history of this particular test measure. Analysis of the control chart shown in Figure 6 yields the following data shown in Table C1. Calibrations that are more frequent should have been performed on the test measure in the early years, because sufÞcient data was unavailable until 1972 or 1973 to construct a control chart with calculated limits. Initially, the calibration facilityÕs uncertainty estimates could have been used until sufÞcient data was available to calculate control levels. For measurements as critical as test measure calibrated volumes, conservative conÞdence limits levels should be used to set warning, action, and tolerance limits. The following statistical conÞdence levels are recommended: Control Level ConÞdence Level % Warning Limits 90 Action Limits 95 Tolerance Limits 99 From the control chart in Figure 6, and the statistical analysis table C1, the following control limits are calculated after four calibrations by the year 1973: Center Line = 4.99788 Warning Limits = 4.99761 and 4.99815 Action Limits = 4.99751 and 4.99825 Tolerance Limits = 4.99720 and 4.99856 From the control chart in Figure 6, three of the past calibrations are outside of the warning limits but no results fall outside of the action limits. This history of each test measure is recorded and kept on Þle by NIST for every test measure calibrated. It is also advisable for the owners of Þeld standard test measures to keep their own current records on Þle, including detailed information on all mainte- nance and modiÞcations performed. Table C1—Statistical Analysis Table of the Calibration History of Test Measure #123456 (5-Gallon Slicker-Plate Test Measure) Year Volume in Gallons Moving Average Moving Range 1960 4.99790 Ð Ð 1965 4.99802 4.99796 0.00012 1972 4.99780 4.99791 0.00022 1973 4.99778 4.99788 0.00024 1982 4.99780 4.99786 0.00024 1982 4.99806 4.99789 0.00028 1982 4.99817 4.99793 0.00039 1982 4.99809 4.99795 0.00039 1992 4.99820 4.99798 0.00042 1994 4.99800 4.99798 0.00042 1996 4.99775 4.99796 0.00045 1996 4.99817 4.99798 0.00045 1996 4.99772 4.99796 0.00048 31COPYRIGHT 2000 American Petroleum InstituteInformation Handling Services, 2000
    • COPYRIGHT 2000 American Petroleum InstituteInformation Handling Services, 2000
    • APPENDIX D—LABORATORY WEIGHTS AND MASS STANDARDS Various classes of weights and mass standards are used for the weight, and the cavity shall be closed by means of a lift- Laboratory Procedures and in Gravimetric Calibrations, and ing knob or other suitable device. their speciÞcations in OIML R 111 describe weights in classes Class M1 weights from 100 g to 50 kg shall have an adjust- as E1, E2, F1, F2, M1, M2, and M3. ing cavity. For weights from 10 g to 50 g, the cavity is For complete information, see OIML R 111. optional, and weights from 1 g to 10 g shall be manufactured This appendix brießy describes the principal physical char- without an adjusting cavity. acteristics and metrological requirements for classes of Class M2 and M3 weights from 100 g to 50 kg shall have weights, that are used: an adjusting cavity. For weights of 20 g and 50 g, the adjust- a. For the veriÞcation of weighing instruments. ing cavity is optional and weights of l0 g and less shall be b. For the veriÞcation of weights of a lower class of accuracy. solid without any adjusting cavity. c. With weighing instruments. For veriÞcation of weighing instruments, it is recom- D.3 Design mended that the tolerance of the weight be < 1/4 of the preci- A weight may have any shape that does not introduce fea- sion needed from the instrument. tures that reduce the reliability. All weights shall be free of ragged or sharp edges or ends. D.1 Terminology Weights less than 1 g shall be ßat polygonal sheets or wires, a. Weight: A material measure of mass, regulated in regard to with appropriate shapes, which permit easy handling. The its physical and metrological characteristics: shape, material, shapes shall be indicative of the nominal value of the weights. surface quality, nominal value, and maximum permissible Weights of 5 g to 50 kg may have different shapes suitable error. for their method of handling. Instead of a lifting knob they b. Accuracy class of weights: A class of weights which meets may have rigid handling devices embodied with the weights, certain metrological requirements intended to keep errors such as axles, handles, etc. within speciÞed limits. c. Traceability: The Òproperty of the result of a measurement D.4 Material of the value of a standard whereby it can be related to stated references, usually national or international standards, All weights shall be corrosion-resistant. The quality of the through an unbroken chain of comparisons all having stated materials used in construction shall be such that the change in uncertaintiesÓ. mass of the weights shall be negligible, relative to the maxi- mum errors permitted in their accuracy class under normal D.2 Physical Characteristics conditions of use. D.2.1 CONSTRUCTION Class E1 and E2 weights shall be constructed of metal or alloy that is practically nonmagnetic. The hardness of this Weights are divided into two types based on design: material and its resistance to wear shall be similar or better a. Type I: These weights are one piece construction and con- than that of austentitic stainless steel. tain no added adjusting material. They should be speciÞed Class F1 and F2 weights shall be constructed of mate- when weights are to be used as standards of the highest order rial that has brittleness and hardness equal to drawn brass. and where maximum stability is required. A precise measure- The material used for weights of this class shall be practi- ment of density can be made only for one-piece weights. cally nonmagnetic. b. Type II: Weights of this type can be of any appropriate Class M1 cylindrical weights of 10 kg and below shall be design, such as screw knob, ring, or sealed plug. Adjusting made of brass or other material whose quality is similar or material can be used as it is of a material at least as stable as better than that of brass. Weights of 1 g and less shall be made the base material and is contained in such a way that it will of a material that is sufÞciently resistant to corrosion and oxi- not become separated from the weights. dization. The surface shall not be coated and the material in Class E1 and E2 weights shall be Type I which is solid and the weights shall be practically nonmagnetic. shall have no cavity open to the atmosphere. They shall have an Class M2 and M3 cylindrical weights of 10 kg and below integral construction, i.e., consist of a single piece of material. shall be made of material which has a hardness and corrosion Class F1 and F2 weights from 1g to 50 kg may be Type I resistance equal to that of cast brass and a brittleness not or Type II, i.e., one or more pieces from the same material. exceeding that of gray cast iron. Gray cast iron shall not be They may contain an adjusting cavity; however, the volume used in weights less than 100 g. Weights shall be practically of this cavity shall not exceed one-Þfth of the total volume of nonmagnetic. 33COPYRIGHT 2000 American Petroleum InstituteInformation Handling Services, 2000
    • 34 API CHAPTER 4—PROVING SYSTEMS D.5 Density examined. The surface of classes M1, M2, and M3 cylindrical weights from 1g to 50 kg shall be smooth and shall not appear Because of the effects of the buoyant force of air on a to be porous when visually examined. weight, precision measurements of mass require that the vol- ume of the weight be known, as well as the density of the air volume in which it is being measured, so that the appropriate D.7 Adjustment corrections can be made. For weights of high precision, the Type I weights including classes E1 and E2 shall be range of density is limited to values at or near the density of adjusted by abrasion, grinding or any appropriate method. The well-established standards, such as are used by NEL, NIST, surface requirements shall be met at the end of the process. etc. As lower precision of measurement is required, so the Type II weights including classes F1, F2, M1, M2, and range of density is broadened. M3 solid weights shall be adjusted by abrasion grinding or any appropriate method that does not alter the surface. D.6 Finish Weights with adjusting cavities shall be adjusted with the same material from which they are made, with tin, or with The surface of the weights shall be smooth and the edges tungsten. For weights that have sealing caps, the cap may shall be rounded. The surface of classes E1, E2, F1, and F2 be made of aluminum. weights up to and including 50 kg shall not appear to be porous and shall present a glossy appearance when visually Table D1—Maximum and Minimum Limits for Density in g/cm3 ( r min , r max ) Nominal Value Class E1 Classes E2, F1 Class F2 Classes M1, M2, M3 > 5 kg 7.934Ð8.067 7.81Ð8.1 7.0Ð8.1 > 4.4 > 5 kgÐ50 mg 7.934Ð8.067 7.7Ð8.1 7.7Ð8.1 > 2.2 < 50 mg > 2.2 > 2.2 > 2.2 > 2.2 Table D2—Application of Standard Mass Weights Application Type Class Primary Reference Standards I E1 Reference Standards for Calibrating E2 Weights I E1 Reference Standards for Calibrating F1 Weights I E2 Standards Used for Calibrating F2 Weights II F1 Standards Used for Calibrating M1 Weights II F2 Standards Used for Calibrating M2 Weights II M1 Standards Used for Calibrating M3 Weights II M2 Creating Balances of Accuracy Class I II E2 Creating Balances of Accuracy Class II II F1 Laboratory Weights for Routine Analytical Work Calibrating Balances of Accuracy Class III, IIIL and IIII II M1, M2, M3 Dial Scales, Trip Balances, and Platform Scales Built-In Weights for High Quality Analytical Balances I or II E2 Student Laboratory Use II M2COPYRIGHT 2000 American Petroleum InstituteInformation Handling Services, 2000
    • APPENDIX E—NIST CERTIFICATES OF CALIBRATION FOR FIELD STANDARD TEST MEASURES (EXAMPLES) 35COPYRIGHT 2000 American Petroleum InstituteInformation Handling Services, 2000
    • 36 API CHAPTER 4.7 U.S. DEPARTMENT OF COMMERCE NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY Gaithersburg, Maryland 20899 REPORT OF CALIBRATION OF A ONE HUNDRED (100) GALLON VESSEL (Graduated Neck Type) Mfg: Exact Fabricators NIST Seal No: 2345 Canton, OH. Material: Stainless Steel Makers No: 8865 Submitted by: ABC Pipeline Company Mytown, TX. (Purchase Order Number XYZ 222-345678 dated August 22, 1997) Assumed Volumetric CoefÞcient of Expansion, 0.0000265 per degree Fahrenheit. The internal volume of the vessel described above has been determined by the volumetric test method using a NIST Standard Test Measure. This method utilizes a volumetric test measure that has a volume that has been compared against NIST reference mass standards. With the vessel in a standing position and the reference attitude established by leveling the attached levels, and drained for 30 seconds after cessation of the main ßow, the results for the volume of water deliv- ered are as follows, using the units in parentheses. Scale* Volume Delivered Volume Delivered Reading (U.S. gal at 60¡F) (in.3 at 60¡F) 0 99.9967 23099.24 *The scale reading is determined by the intersection of the horizontal plane, tangent to the bottom of the meniscus reading in the gauge tube. A scale division, between -125 and +125 is equivalent to 5 in.3. The NIST Standard Volumetric Test Measure used above has an expanded uncertainty of symbol of ±0.02% according to Reference [2]. This reference gives the deÞnitions of terms used below and details on this method for producing expanded uncertainty assessments. The expanded uncertainty quoted above is obtained by computing the standard deviation of the mean for two [2] Taylor, B.N. and Kuyatt, C.E., “Guidelines for Evaluating and Expressing the Uncertainty of NIST Measurement Results,” NIST Technical Note 1297, National Institute of Standards and Technology (January 1993). NIST Test No.: 444/123456-97-8 Calibration Date: August 29, 1997 Page 1 of 2COPYRIGHT 2000 American Petroleum InstituteInformation Handling Services, 2000
    • MPMS CHAPTER 4.7—FIELD STANDARD TEST MEASURES 37 REPORT OF CALIBRATION ABC Pipeline Company, Volume Standards independent measurements; this is deÞned as Type A Evaluation of Standard Uncertainty, uA, as a percentage of the mean value. This Type A Standard Uncertainty is ±0.004%; it is composed of the imprecision of all the components of the NIST measurement process; it includes gauge scale readings, interior wall drainage characteristics, etc. The Type B Evaluation of Standard Uncer- tainty, uB, for the volume transfer standard is estimated to be ±0.01%; this is based on volume measurement experience. These Type A and B Standard uncertainties are combined using the root-sum-of-squares (RSS) method to produce the Combined Standard Uncertainty, uc. This Combined Standard Uncertainty is multiplied by a coverage factor, k, that is taken to be 2 to give the expanded uncertainty, U. In the equation form, this procedure is: 2 2 U = k ´ uc = k ( u A + uB ) The test results shown above are the arithmetic means of two independent observations. The stated volume is corrected to a reference temperature of 15.56¡C (60¡F). The reported volume has an estimated uncertainty that is computed by Þrst taking the standard deviation of the mean of two measurement results, this is referred to as Type A Evaluation of the Standard uncertainty of the test measure. This Type A Standard Uncertainty is squared and added to the square of the Type B Standard Uncertainty which is taken to be that for the NIST capability, ±0.015. The square root of this sum gives the Combined Standard Uncertainty for the test measure. By multiplying this Combined Standard uncertainty by a coverage factor of 2 produces the expanded uncertainty. The expanded uncertainty for this test measure is ±0.045. For the Director, National Institute of Standards and Technology Dr. George E. Mattingly Leader, Fluid Flow Group Process Measurements Division Chemical Science and Technology Laboratory NIST Seal No.: 2345 NIST Test No.: 444/123456-97-8 Calibration Date: August 29, 1997 Page 2 of 2COPYRIGHT 2000 American Petroleum InstituteInformation Handling Services, 2000
    • 38 API CHAPTER 4.7 U.S. DEPARTMENT OF COMMERCE NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY Gaithersburg, Maryland 20899 REPORT OF CALIBRATION OF A ONE HUNDRED (100) GALLON VESSEL (Graduated Neck Type) Mfg.: Exact Fabricators NIST Seal No.: 2345 Canton, OH. Material: Stainless Steel Makers No.: 8865 Submitted by: ABC Pipeline Company Mytown, TX. (Purchase Order Number XYZ 123 dated August 22, 1997) Assumed Volumetric CoefÞcient of Expansion, 0.0000265 per degree Fahrenheit. The internal volume of the vessel described above has been determined by the gravimetric test method. The gravimetric method requires weighing the empty vessel and re-weighing when Þlled with a ßuid of known density. The ßuid used was water. With the vessel in a standing position, the reference attitude was established by leveling the attached levels. The internal volume deter- mined in this way is termed the contained volume and the value is given below using the units requested in parentheses: Volume Contained Volume Contained Scale* (U.S. gal at 60¡F) (in.3 at 60¡F) 0 99.9800 23095.4 Per request, the delivered volume of this vessel was determined by the following procedure. To establish the delivered volume, the contained volume is drained through the bottom valve. When the main ßow of liquid ceases, a 30-second drain time is observed before closing the valve. Sub- sequent re-weighing completes the gravimetric procedure and enables determination of the deliv- ered volume. The results for the delivered volume of water are as follows, using the units requested in parentheses: NIST Test No.: 123/12345 Calibration Date: August 29, 1997 Page 1 of 2COPYRIGHT 2000 American Petroleum InstituteInformation Handling Services, 2000
    • 39 API CHAPTER 4.7 REPORT OF CALIBRATION ABC Pipeline Company, Volume Standards Volume Delivered Volume Delivered Scale* (U.S. gal at 60¡F) Reading (in.3 at 60¡F) 0 99.9575 23090.2 *The scale reading is determined by the intersection of the horizontal plane, tangent to the bottom of the meniscus reading in the gauge tube. A scale division, between -200 and +200 is equivalent to 2 in3. The expanded uncertainty in the measured volume is ±0.003%. It was calculated according to Reference [2] with a coverage factor of 2 and is traceable to NIST reference mass standards. For the Director, National Institute of Standards and Technology Dr. George E. Mattingly Leader, Fluid Flow Group Process Measurements Division Chemical Science and Technology Laboratory [2] Taylor, B.N. and Kuyatt, C.E., “Guidelines for Evaluating and Expressing the Uncertainty of NIST Measurement Results”, NIST Technical Note 1297, National Institute of Standards and Technology (January 1993). NIST Seal No.: 2345 NIST Test No.: 234/12345 Calibration Date: August 29, 1997 Page 2 of 2COPYRIGHT 2000 American Petroleum InstituteInformation Handling Services, 2000
    • COPYRIGHT 2000 American Petroleum InstituteInformation Handling Services, 2000
    • APPENDIX F—WATER DENSITY EQUATIONS In 1981, a working group of the API Committee on Static d = Ð46.170461 x 10-6 kg/m-3 ¡C-3, Petroleum Measurement was set up to review standards, and advise on the water density equation to be used by API. They e = 105.56302 x10-9 kg/m-3 ¡C-4, recommended the use of the internationally accepted water f = Ð280.54253 x 10-12 kg/m-3 ¡C-5, density versus temperature equation of Wagenbreth and Blanke. g = 16.879850 x 10-3 kg/m-3 ¡C-1. The relationship is shown below: Evaluation of these two equations showed that the calcu- 2 3 4 5 lated water densities could differ by two parts in a million; r ( T w ) = a + bT w Ð cT w + dT w Ð eT w + f T w kg/m3 e.g., 999.012 versus 999.014 kg/m3 respectively, for the den- sity of water at 60¡F. However, the volumetric correction fac- Note: Wagenbreth, H., and Blanke, H., ÒThe Density of Water in the tors (density ratios) developed by either equation are International System of Units and in the International Practical Tem- perature Scale of 1968,Ó Mitteilungen der Physikalish-Technischen essentially constant and unaffected by the mathematical treat- Budnesanstalt (PTB-Mitt), pp. 412Ð415, June 1971. ments under consideration. The Wagenbreth and Blanke equation is used to generate where (in compatible units) water densities at various temperatures. The ratio of the water r = True water density in kg/m3, density between the test measure ( r TM ) and the prover ( r TP ) is equivalent to the correction factor CTDW. Tw = Water temperature, ¡C, a = 999.8395639 kg/m-3, ( r TM ) CTDW = ------------ - ( r TP ) b = 0.06798299989 kg/m-3 ¡C-1, c = 9.106025564 x 10 Ð3 kg/m-3 ¡C-2, where d = 10.05272999 x 10-5 kg/m-3 ¡C-3, r = the water density, kg/m3, e = 112.6713526 x 10-8 kg/m-3 ¡C-4, T = temperature, ¡C, [(temperature ¡F Ð 32)/1.8] f = 659.1795606 x 10-11 kg/m-3 ¡C-5. TM = the test measure temperature, NIST used this standard until recently; however, their TP = the prover temperature. water density calculations have now been converted to the The limits in prover temperatures are 35 to 105¡F and in equation developed by G.S. Kell. This relationship is shown test measure temperatures 32.1 to 105¡F. This is the tempera- below: ture range used for the Wagenbreth equation, and, therefore, any extrapolation outside of this temperature range is not 2 3 4 5 a + bT w + cT w + dT w + eT w + fT w recommended. The Kell equation, however, can be used for r ( T w ) = ---------------------------------------------------------------------------------------- kg/m3 - 1 + gT w calculating CTDW values when the temperature is outside of the range recommended for the Wagenbreth equation. Note: Kell, G.S., ÒDensity, Thermal Expansion, and Compressibility Using the Wagenbreth equation yields a maximum uncer- of Liquid Water from 0¡ to 150¡C: Correlations and Tables for tainty in any CTDW value of ±0.000007. As discussed previ- Atmospheric Pressure and Saturation Reviewed and Expressed in ously, use of the Wagenbreth equation versus the Kell 1968 Temperature Scale,Ó Journal of Chemical and Engineering equation essentially does not yield any differences in CTDW Data, Volume 20, pp. 97Ð105, 1975. values. That is, CTDW values from the two equations will dif- where (in compatible units) fer by less than 0.0000005, within the temperature range of the standard. On rounding to six decimal places approxi- r = True water density in kg/m3, mately, less than 9% of the equivalent values could differ by Tw = Water temperature, ¡C, ±0.000001. For this reason, it is not recommended that the Kell equation be used to duplicate the Wagenbreth standard. a = 999.83952 kg/m-3, Operators should be aware, however, that all test measures calibrated by NIST will have the volumes calculated using b = 16.945176 kg/m-3 ¡C-1, the density of water derived from the Kell equation. c = Ð7.9870401 x 10-3 kg/m-3 ¡C-2, 41COPYRIGHT 2000 American Petroleum InstituteInformation Handling Services, 2000
    • COPYRIGHT 2000 American Petroleum InstituteInformation Handling Services, 2000
    • 12/98—3CCOPYRIGHT 2000 American Petroleum InstituteInformation Handling Services, 2000
    • Additional copies available from API Publications and Distribution: (202) 682-8375 Information about API Publications, Programs and Services is available on the World Wide Web at: http://www.api.org Order No. H04072COPYRIGHT 2000 American Petroleum InstituteInformation Handling Services, 2000