  • 1. Introducing Abulox Technology
  • 2. B & V - Innovation and Technology DrivenUK Technical and R&DLaboratoriesApplication SpecialistsIndustry ExpertsCustomer Training/SeminarsRegulatory SupportEngineering Solutions
  • 3. Current Applications for Stable Active Halogens• Infection Control• Water Treatment• Process Control• Wound Care• Laundry
  • 4. Water Treatment Applications• Domestics including potable water• Tank Cleaning• Shower Water• Process Water• Filters and Membranes
  • 5. Food Company Case Study• Recirculating hot water system• Continuous Legionella issues• Numerous disinfections with Chlorine Dioxide, Silver/Hydrogen Peroxides and Chlorine with little effect• Abulox trialled at maintenance dose of 0.5 – 1 ppm after an initial shock of 5 ppm for 3 days
  • 6. Case Study – Legionella Results Legionella Results Removal of Biofilm 5 4.5 4 3.5 Mens 4th floor hot 3 Ladies Ground floor hotLog 2.5 Reduced Visitors hot to Zero Mens cloakroom hot 2 Ladies cloakroom hot 1.5 Ladies 2nd floor hot 1 Ladies 2nd floor hot 0.5 Ladies cloakroom hot Mens cloakroom hot 0 Visitors hot 01.04.11 Ladies Ground floor hot 04.04.11 05.04.11 06.04.11 Mens 4th floor hot 08.04.11 13.04.11 15.04.11 Sample Date 19.04.11
  • 7. Case Study – Pseudomonas ResultsPseudomonas Results 3.5 3 2.5 Mens 4th floor hot 2 Ladies Ground floor hotLog Visitors hot 1.5 Mens cloakroom hot Ladies cloakroom hot 1 Ladies 2nd floor hot 0.5 Ladies 2nd floor hot Ladies cloakroom hot Mens cloakroom hot 0 Visitors hot 01.04.11 Ladies Ground floor hot 04.04.11 05.04.11 06.04.11 Mens 4th floor hot 08.04.11 13.04.11 15.04.11 Sample Date 19.04.11
  • 8. Government Organisation Case Study• Potable cold water supply• Under capacity building with poor quality incoming mains• Traditional liquid and dual powder pack chlorine dioxide treatment & chlorinations were not able to solve the problem• System shock dosed for 48hrs and chemical maintained at 1.5ppm Cl2
  • 9. Case Study – TVC 22 Results TVC 22140012001000800 GF Quiet/First Aid Room CWS600400 Zero200 0 Incoming Mains Chlorine Dioxide Chlorine Dioxide Abulox 1 2
  • 10. Case Study – Pseudomonas Results Pseudomonas 1400 1200 1000 800 GF Accessible Shower 600 400 Zero 200 0 Incoming Mains Chlorine Dioxide 1 Chlorine Dioxide 2 Abulox
  • 11. Case Study – Legionella Results Legionella1200010000 8000 6000 GF Accessible Toilet CWS 4000 Zero 2000 0 Chlorine Dioxide 1 Chlorine Dioxide 2 Abulox
  • 12. NHS Healthcare Case Study• Building only 4 years old• B & V took over in 2008 -site not fully occupied• Several hundred outlets, with some low/no usage, and low turnover of water• Legionella problems from day 1• Flushing and high temperature pasteurisation did not eliminate the problem• Cold – TVCs and Pseudomonas problems• Hot – Legionella (~1/3), TVC and Pseudomonas problems
  • 13. The Trial• Dosing equipment installed by B & V• Shock dosed for 2 days• Down to maintenance dose (0.5-1.5ppm Cl2)• B & V technical team regularly visited for 3 months – chemical monitoring and samples carried out on 4 CW and 6 HW points• Quarterly positive outlets added to sampling (total=18)
  • 14. The Results Cold
  • 15. The Results Hot
  • 16. The Results Hot
  • 17. The Results Hot
  • 18. Conclusion• All Legionella eliminated from trial points• 1 rogue outlet picked up on additional sampling due to lack of flushing• All Pseudomonas and TVCs reduced to zero• Abulox has brought the micro problems under control and has been adopted
  • 19. Benefits Summary• High level of microbial control and biofilm removal• Simple to apply and measure• One Pack product• Low capital cost• Easy to maintain• Ideal for hospitals and care homes• Solves persistent legionella issues• Ease of use• Regulatory approvals• New patented technology