Your SlideShare is downloading. ×
0
DVLS³ (S)imply, (S)mart, multi-(S)ensor                “Focus on Hydrogen”                         Exclusive North America...
DVLS³ (S)imply, (S)mart, multi-(S)ensor                   4 Reasons for using H2 as a Carrier Gas1.       Fast Analysis:  ...
DVLS³ (S)imply, (S)mart, multi-(S)ensor                  4 Reasons for using H2 as a Carrier Gas3. Prolonged Column Life: ...
DVLS³ (S)imply, (S)mart, multi-(S)ensor                  Reluctant to use H2 as a Carrier Gas?                            ...
DVLS³ (S)imply, (S)mart, multi-(S)ensor                   Hydrogen Sensor     29 November 5   2012
DVLS³ (S)imply, (S)mart, multi-(S)ensor                  Sensor Installed in the GC Oven    29 November6   2012
DVLS³ (S)imply, (S)mart, multi-(S)ensor                  Carrier Gas Switch    29 November7   2012
DVLS³ (S)imply, (S)mart, multi-(S)ensor                  Sequence Stop after Analysis    29 November8   2012
DVLS³ (S)imply, (S)mart, multi-(S)ensor                       Calibration Zero Point Calibrated Using Air Alarm level Ca...
DVLS³ (S)imply, (S)mart, multi-(S)ensor                          Alarms Acoustic Optical (blinking display) SMS Message...
DVLS³ (S)imply, (S)mart, multi-(S)ensor        Catalystic Pellistor Sensor & Wheatstone Bridge     29 November11   2012
DVLS³ (S)imply, (S)mart, multi-(S)ensor                           Summary & Benefits Catalytic Pellistor gas specific sen...
Upcoming SlideShare
Loading in...5
×

Da Vinci DVLS3 Simply, Smart Hydrogen Sensor for Gas Chromatographs

1,546

Published on

Envantage is the exclusive North American distributor of the Da Vinci DVLS3 hydrogen sensor. Install this sensor in your GC to reduce the risk of explosion due to hydrogen leaks that may develop around your instrument hot zones.

0 Comments
0 Likes
Statistics
Notes
  • Be the first to comment

  • Be the first to like this

No Downloads
Views
Total Views
1,546
On Slideshare
0
From Embeds
0
Number of Embeds
5
Actions
Shares
0
Downloads
2
Comments
0
Likes
0
Embeds 0
No embeds

No notes for slide

Transcript of "Da Vinci DVLS3 Simply, Smart Hydrogen Sensor for Gas Chromatographs"

  1. 1. DVLS³ (S)imply, (S)mart, multi-(S)ensor “Focus on Hydrogen” Exclusive North American Distributor1
  2. 2. DVLS³ (S)imply, (S)mart, multi-(S)ensor 4 Reasons for using H2 as a Carrier Gas1. Fast Analysis:  Fast diffusion rate; 4 times faster than N2  Half as viscous as helium; higher linear gas velocity and shorter retention times2. High Efficiency:  Flattest Van Deemter curve 29 November2 2012
  3. 3. DVLS³ (S)imply, (S)mart, multi-(S)ensor 4 Reasons for using H2 as a Carrier Gas3. Prolonged Column Life: Some applications have a lower elution temperature, therefore the column life is longer4. High Efficiency:  3x’s less expensive than its helium equivalent  Bottle or generator 29 November3 2012
  4. 4. DVLS³ (S)imply, (S)mart, multi-(S)ensor Reluctant to use H2 as a Carrier Gas?  Hydrogen is an Explosive Gas:  Undetected gas leaks can lead to an explosion in the GC Oven  LEL 4% hydrogen in Air 29 November4 2012
  5. 5. DVLS³ (S)imply, (S)mart, multi-(S)ensor Hydrogen Sensor 29 November 5 2012
  6. 6. DVLS³ (S)imply, (S)mart, multi-(S)ensor Sensor Installed in the GC Oven 29 November6 2012
  7. 7. DVLS³ (S)imply, (S)mart, multi-(S)ensor Carrier Gas Switch 29 November7 2012
  8. 8. DVLS³ (S)imply, (S)mart, multi-(S)ensor Sequence Stop after Analysis 29 November8 2012
  9. 9. DVLS³ (S)imply, (S)mart, multi-(S)ensor Calibration Zero Point Calibrated Using Air Alarm level Calibrated using Calibration Mixture Yearly or after maintenance or repair 29 November 9 2012
  10. 10. DVLS³ (S)imply, (S)mart, multi-(S)ensor Alarms Acoustic Optical (blinking display) SMS Message 29 November 10 2012
  11. 11. DVLS³ (S)imply, (S)mart, multi-(S)ensor Catalystic Pellistor Sensor & Wheatstone Bridge 29 November11 2012
  12. 12. DVLS³ (S)imply, (S)mart, multi-(S)ensor Summary & Benefits Catalytic Pellistor gas specific sensor, linear range of 0-2% H2 (0-50% LEL) Unaffected by humidity, stable output for long periods, more resistant to shocks and vibrations. Expected lifetime: over five years Long term stability; drift sensitivity: less than 2mV a month User defined alarm: optical, acoustic and/or SMS up to 50% LEL Instrument readings: provide real time sensor readings with alarm levels, channel states User menu for configuration (password protected) Valve : High pressure 3 way solenoid valve Oven operating temperature: up to 450ο C Multiple Sensors: Max 4 sensors individually controlled Sensor options: temperature, barometer, level, oxygen or hydrogen as a leak detector. 29 November12 2012