Brecknell Replacement Load Cells For Scales

2,372 views
2,160 views

Published on

The lineup of Brecknell load cells and supporting products from Brecknell are ideal for many weighing applications. The full range of Zemic load cells should complement and support your service and original equipment requirements. Many of the Brecknell load cells are interchangeable with the brand name cells that you're used to. So if your normal brand name cell is out of stock or has a longer lead time than you would prefer, contact us and ask for the equivalent Brecknell replacement load cell. Also, the load cell cross reference guide is a very helpful tool for picking the correct replacement load cell for your application.

0 Comments
0 Likes
Statistics
Notes
  • Be the first to comment

  • Be the first to like this

No Downloads
Views
Total views
2,372
On SlideShare
0
From Embeds
0
Number of Embeds
0
Actions
Shares
0
Downloads
0
Comments
0
Likes
0
Embeds 0
No embeds

No notes for slide

Brecknell Replacement Load Cells For Scales

  1. 1. Brecknell 1000 Armstrong Drive Fairmont, Minnesota 56031 Toll Free: 800-637-0529 Telephone: 507-238-8702 Fax: 507-238-8271 Email: sales@brecknellscales.com Brecknell Foundry Lane Smethwick, West Midlands England B66 2LP Telephone: +44 (0) 845 246 6717 Fax: +44 (0) 845 246 6718 Email: sales@brecknellscales.co.uk Www.brecknellscales.co.uk Brecknell 217 Brunsweick Boulevard Pointe-claire, Quebec Canada H9R 4R7 Toll Free: 800-268-1662 Telephone: 416-213-9900 Fax: 416-213-9960 Email: sales@brecknellscales.ca Salter India Limited Plot #53, Sector 25, (Avery India Compound) Ballabgarh 121 004, Faridabad, Harvana (India) Telephone: 91-129-4094400 Fax: 91-129-4094591, 2234091 Email: Sales@averyindia.net Www.salterindia.com Manufacturer Models Excitation + Excitation - Signal + Signal - Shield Sense + Sense - A&D Engineering RED WHITE GREEN BLUE YELLOW Allegany Technology GREEN BLACK RED WHITE BARE Advance Transducers RED BLACK GREEN WHITE BARE Allegany GREEN BLACK WHITE RED BARE Alphartron RED BLACK GREEN WHITE BARE Anyload RED BLACK GREEN WHITE BARE 108LSMT GREEN BLACK RED WHITE BARE BLUE BROWN Artech RED BLACK GREEN WHITE BARE Avery Weigh-Tronix GREEN BLACK WHITE RED WHITE/ORANGE Beowulf GREEN BLACK WHITE RED BARE BLH GREEN BLACK WHITE RED YELLOW Cas RED BLACK GREEN WHITE BARE BLUE BROWN Celtron RED BLACK GREEN WHITE BARE Cardinal GREEN BLACK WHITE RED BARE CNCell RED BLACK GREEN WHITE BARE Coti GREEN BLACK WHITE RED BARE Digi RED WHITE GREEN YELLOW GRAY Dillon CANISTER TENSION RED BLACK GREEN WHITE ORANGE COMPRESSION RED BLACK WHITE GREEN ORANGE Z-CELL RED BLACK WHITE GREEN ORANGE Electroscale RED BLACK GREEN WHITE BARE Epelsa RED BLACK GREEN WHITE BARE VIOLET GRAY Evergreen GREEN BLACK WHITE RED BARE Flintec PC1,PC2,PC6,RC1,SB4,SB5,SB6,SB14,SLB,UB1,UB6,SB10, PCB,BK2 GREEN BLACK WHITE RED YELLOW Force Measurement RED BLACK GREEN WHITE BARE General Sensor RED BLACK GREEN WHITE BARE Genisco RED BLACK GREEN WHITE BARE GSE RED BLACK WHITE GREEN BARE HBM SBF,SB3,USBU1T,Z6, H35 GREEN BLACK WHITE RED YELLOW BLC,BLF,JRT,PWS,RSC GREEN BLACK WHITE RED YELLOW PLC,B35, SBE RED BLACK GREEN WHITE YELLOW BBS GREEN BLACK WHITE RED BARE SP4, SP10,PW15,PWS,PWSM GREEN BLACK WHITE RED YELLOW ORANGE BLUE PW12,PW16,C16,PW15AH BLUE BLACK WHITE RED YELLOW GREEN GRAY Interface SSM,1200,3200 RED BLACK GREEN WHITE BARE Kubota RED WHITE GREEN BLUE YELLOW LeBow RED BLACK GREEN WHITE BARE Mettler Toledo WHITE BLUE GREEN BLACK ORANGE YELLOW RED National Scale GREEN BLACK WHITE RED YELLOW Nikkei RED BLACK GREEN WHITE BARE NCI RED BLACK WHITE GREEN BARE YELLOW BLUE NMB RED WHITE GREEN BLUE BARE Ormond RED BLACK GREEN WHITE BARE Pennsylvania ORANGE BLUE GREEN WHITE BARE Pesage Promotion BLUE WHITE RED BLACK YELLOW Philips RED BLUE GREEN GRAY BARE Revere Transducers 62HU,63HU,363,953,9523 RED BLACK GREEN WHITE BARE 92CC,93CC,24U,43U,263D,462,6762, 9102, 9103, 9123,9363,5102,5103, 5123, 5223, 5723, 9363 RED BLACK GREEN WHITE ORANGE 392B,642,652,692B2,BSP,HPS, USP1 GREEN BLACK WHITE RED BARE 792, 933, SHB, SSB GREEN BLACK WHITE RED CLEAR CP1,CSP1 GREEN BLACK WHITE RED ORANGE RLC PINK GRAY BROWN WHITE BARE Rice Lake Weighing RL20000,RL20000SS,RL20001HE,RL30000,RL75061,RL50500, RL70000SS,RL71000HE,RL75016HE RED BLACK GREEN WHITE BARE RL35023,RL35023S,RL35082,RL35083,RL39123,RL75223,RL90000,RLETB, RLETS,RLHSS,RLMK4 RED BLACK GREEN WHITE BARE RL39523,RL50210,RL56044,RL70000,RL75016,RL75016SS,RL75040A, RL75058,RL75060 RED BLACK GREEN WHITE BARE RLMK1 RED BLACK WHITE GREEN ORANGE YELLOW BLUE RLMK15,RLMK21 RED BLACK GREEN WHITE ORANGE RL1521A GREEN BLACK RED WHITE BARE RL40BBS,RLBLC,RLSB2,RLSB2L,RLSB2M,RLSB250,RLSSB,RLKIS, RL9000TWM,RL75114,RLSCA,RLBLP,RLSB2MLW GREEN BLACK WHITE RED BARE RL8C2P1SS,RLCSP1,RL75000SS,RL30745 GREEN BLACK WHITE RED ORANGE RL1380,RL1385,RLH35,RL30745,RLPC6 GREEN BLACK WHITE RED YELLOW RLPCB-60 GREEN BLACK WHITE RED YELLOW BLUE BROWN RL1010,RL1040,RL1140,RL1250,RL1260 GREEN BLACK RED WHITE BARE BLUE BROWN RLHBB,RLHTO BLUE BLACK WHITE RED BARE GREEN GRAY RL32155 WHITE BLUE GREEN BLACK ORANGE YELLOW RED Scaime BROWN GREEN YELLOW BLACK WHITE GRAY PINK Sensortronics RED BLACK GREEN WHITE BARE Sensotec RED BLACK WHITE GREEN BARE Strainsert RED BLACK GREEN WHITE BARE T-Hydronics RED BLACK GREEN WHITE BARE Tedea Huntleigh GREEN BLACK RED WHITE BARE BLUE BROWN Thames Side RED BLUE GREEN YELLOW BARE Toledo GREEN BLACK WHITE RED YELLOW Totalcomp RED BLACK GREEN WHITE BARE Transducers Inc. RED BLACK GREEN WHITE ORANGE Transcell RED BLACK GREEN WHITE Vishay BLH C2P1,C3P1,T2P1,T3P1 GREEN BLACK WHITE RED YELLOW Vishay Celtron PSD,SEB,LCD,CSB,DSR,LOC,SQB,STC,STCSS,DSR,CLB,HED,DLB,SQB,HSS RED BLACK GREEN WHITE BARE LPS RED BLUE GREEN WHITE BARE HOC,MOC GREEN BLACK RED WHITE BARE BLUE BROWN Vishay Sensortronics 60001,60008,60018,60030,60036,60040,60048,60048SS,60050,60051,60060, 60060-101,60063,65007,65016,65016SS RED BLACK GREEN WHITE BARE 65016W,65023,65023S,65023SS,65024,65040A,65040S, 65058S,65061A,65083,65083S,65114 RED BLACK GREEN WHITE BARE 6007, 60064 GREEN BLACK WHITE RED BARE 65088-1000,65088-1114 GREEN BLACK WHITE RED ORANGE Vishay Tedea-huntleigh 4157, 4158 RED BLACK GREEN WHITE BARE 3411, 3421 RED BLACK GREEN WHITE BARE BLUE BROWN 240, 1010, 1022, 1040, 1140, 1250, 1260, 1320,9010, 605, 1030, 1240, 1241, 1030,9010, 1030,1320,1510 GREEN BLACK RED WHITE BARE BLUE BROWN 355, 620, 3510 BLUE BLACK WHITE RED BARE GREEN GRAY Wiring Guide Central Carolina Scale, Inc 5393 Farrell Road Sanford NC 27330 PH: 919-776-7737 www.CentralCarolinaScale.com
  2. 2. UNITED STATES TEL: 800-637-0529 WWW.BRECKNELLSCALES.COM UNITED KINGDOM TEL: + 44 (0) 845 246 6717 WWW.BRECKNELLSCALES.CO.UK CANADA TEL: 416-213-9900 WWW.BRECKNELLSCALES.CA INDIA TEL: +91 129 4159774/75/76 WWW.SALTERINDIA.COM Additional 20% off list price on orders over 1,000 NET Use Promo Code SBWP250 to receive discount st Valid through March 31 , 2013 Free freight on orders over 1,000 NET (not to be used with any other discounts/specials) Use Promo Code SBWP254 to receive discount st th Valid May 1 - 29 , 2013 Receive 10% off list price on any Brecknell Indicator order over 1,000 NET (to view indicators visit or your Brecknell Global Catalog) Use Promo Code SBWP255 to receive discount st st Valid July 1 - 31 , 2013 www.brecknellscales.com, www.brecknellscales.co.uk Brecknell Revere HBM Tedea Celtron Sensortronics Coti Artech Rice Lake Totalcomp BLH Fairbanks NMB Thurman Transcell Flintec Vishay BCL 1004 L6B 1004 L6C H2A H2D H2F H2J1 L3H H3 STC 60001-0221 COMPACT CISB H3C H3E H3F STC 60001,60036,RTI363 CISB H3G M363 STC 60001 20210 RL20000 / 20001 BSA / BSS STC H3G-Y 363 STR 60001 H3Y L3H 6362 L6D 640 PW6-2 1022 LPS 600g ~ 35kg CI-22 61022 RL1521 C2G1 4900 C2C1 C2G1 / LPS L6D4 PW6K 1022 LPS L6D5 L6E LPS L6E3 1263 L6F 1320 HOC L6G 672 LOC FAV L6H L6Q 650 1241 LPS 60kg ~ 200kg L6J L6J1 1006 L6J5 L6L L6N 642 SP4 1042 MT1041 RL1042 L6S 1030 L6T 652 1252 L6X L6Y H6G5 H6B H8 SB3 H8A H8B Z7 H8C 5123 3411 SQB 65023 CI-23 30310 RL35023 TSB SBS SQB H8K 5723 H9A H9B MDB H9C 5103 H9D 5203 DSR 65016 CI-16 70510 RL75016 DSR H9G H9G1 H9C-Y 5103 CSB 60058 CI-5103 70210 RL70000 H9D-Y 5203 H9H DLB 65040A BE40 80310 RL75040 TDE40 TSC840 DLB H9N 5303 4158 CLB 65058 CI-58 RL75058 CLB H10 H10A B3G M9363 STC 60050 B3G-Y 9363 STR 60050 B8D M9123 3410 SQB 65023 B8D-Y 9123 3421 SQB 65023 B8H ALC HVC 65083S BM6A 60064 B8K 9723 BM8D H35 BM8L 9113 BM8F 9523 BM8H ACB HLC HVC 65084 BM8G SSB SB3 CI-SB3 SS30610 RLSSB HM8 B9C-Y 9103 CI-5103-SSW RL7100HE B9D-Y 9203 DSR-HSS 65016W CI-16-SSW RL75016SS DSR-HSS B9E-Y 9223 B9F-Y 9323 DLB SS 65040S BE40-SSW RL75040A TSC840 B9N 9303 65058SS B9H-Y 9903 DLB SS 65040S BE40-SSW RL75040A B9J 9803 B9K 9423 HM9B HM9E-Y 5223 HED 65040-1127W CI-5223 80210 RL75223 TSC800 BM11 SHB Z6 355 HBB RLHBB HBB BM14A CSP 65088-1000 CP26S5 90310 RLCSP1 TCSP1 BM14C BM14G ASC BM14K C16 CP26S4 HM14C B14H CCC B14D H24L HM24M BM24R RLC PW12 1250 RL1250 PCB LOC B6Q 1241 S.S. Cross Reference Guide *Standard ground freight only *Valid for orders from inter-country stocking locations
  3. 3. Brecknell 1000 Armstrong Drive Fairmont, Minnesota 56031 Toll Free: 800-637-0529 Telephone: 507-238-8702 Fax: 507-238-8271 Email: sales@brecknellscales.com www.brecknellscales.com Brecknell Foundry Lane Smethwick, West Midlands England B66 2LP Telephone: +44 (0) 845 246 6717 Fax: +44 (0) 845 246 6718 Email: sales@brecknellscales.co.uk www.brecknellscales.co.uk Brecknell 217 Brunswick Boulevard Pointe-Claire, Quebec Canada H9R 4R7 Toll Free: 800-268-1662 Telephone: 416-213-9900 Fax: 416-213-9960 Email: sales@brecknellscales.ca www.brecknellscales.ca Salter India Ltd. Plot #53, Sector 25, (Avery India Compound) Ballabgarh 121 004, Faridbad, Harvana (India) Telephone: 91-129-4094400 Fax: 91-129-4094591, 2234091 Email: sales@averyindia.net Www.averyindia.co.in CONTACT INFORMATION UNITED STATES TEL: 800-637-0529 WWW.BRECKNELLSCALES.COM UNITED KINGDOM TEL: + 44 (0) 845 246 6717 WWW.BRECKNELLSCALES.CO.UK CANADA TEL: 416-213-9900 WWW.BRECKNELLSCALES.CA INDIA TEL: +91 129 4159774/75/76 WWW.SALTERINDIA.COM COMPANY HISTORY Brecknell, part of Avery Weigh-Tronix, a proud member of the Illinois Tool Works (ITW) company, celebrated 250 years of customer commitment and history in 2011. Founded in 1761, under Salter Brecknell, Brecknell has grown to become a global leader in weighing solutions. Brecknell products are designed and constructed with focus on high-value solutions and accuracy for easy operation for all your weighing applications. Today, Brecknell products can be found for most weighing applications. The Brecknell global footprint and reach allows Brecknell to offer the highest quality of service an support to our customers. Fairmont, Minnesota Birmingham, England Montreal, Canada India
  4. 4. Naming System of Load Cell / Force Transducers 2 1kg/cm 3m Naming System of Weighing Assembly UNITED STATES TEL: 800-637-0529 WWW.BRECKNELLSCALES.COM UNITED KINGDOM TEL: + 44 (0) 845 246 6717 WWW.BRECKNELLSCALES.CO.UK UNITED STATES TEL: 800-637-0529 WWW.BRECKNELLSCALES.COM UNITED KINGDOM TEL: + 44 (0) 845 246 6717 WWW.BRECKNELLSCALES.CO.UK Material: H: Alloy Steel B: Stainless Steel L: Aluminum Accuracy: N3: NTEP 3000 Division N5: N10: G1: 0.1% Accuracy G2: 0.2% Accuracy G3: 0.3% Accuracy NTEP 5000 Division NTEP 10,000 Division C1: OIML Certified 1000 Division C2: OIML Certified 2000 Division C3: OIML Certified 3000 Division C3D: OIML Certified 2500 Division C3G: OIML Certified 4000 Division Sealing: No mark: Adhesive potted M: Hermetic welded XXXXX XX X XXXXX d: Digital load cell t: High temperature working Different Series of Appearance: A, B, C, D, E, E3, F, G, G5, H,H5, J, L, N, Q, OC3, W Thread: No mark: Metric Y: Imperial Type & Structure: 2: Spoke Type 3: S-Beam 6: Single Point 8: Single Shear Beam 9: Dual Shear Beam 11: Single Point with Bellow 14: Column type 16: Dual Parallel Beam Capacity: lb: Pounds (lb) K: Klb Kg: Kilograms t: Metric tons N: Newtons KN: Kilo Newtons MN: Million Newtons SE: Small Envelope LE: Large Envelope Material: H: Alloy Steel B: Stainless steel L: Aluminum Assembled Load Cell Type: 2: Spoke Type 3: S-Beam 6: Single Point 8: Single Shear Beam 9: Dual Shear Beam 11: Single Point with Bellow 14: Column type 16: Dual Parallel Beam Structure: J: Foot Y: Load button D: Plate L: Ring M: Mounting XX XX XXX XX / XX Series Number: Defined by number or letter Capacity Range Load Cell Protection Class Reference to National Standard of the Cover Protection Class System (P.R.C.) Equal to IEC529 Standard (International Electrotechnical Commission IP-6- Protection Level Class Description Meanings Experimental Method Achieved Protection Class 5 6 7 8 Adhesive sealed common load cell could achieve Cover sealed inner adhesive protected load cells could achieve Cover (or bellow) welded, inner adhesive protected load cells could achieve. Besides of oil-proof, water proof, it also can proof the common corrosive gas and medium Special required load cells could be customized Water- sprinkle proof Not be affected by the water-sprinkle from any direction in a short time Not be affected by the strong water-spray from any direction in a short time Not be affected by the inundating into water in a stated pressure and time Can dived into water for a long time Water- sprayed protection Soggy Proof Diving Proof Decided individually Inundate into 1 meter deep water for 30 minutes Continually spray water from any direction more than 15 minutes Continually spray water from any direction more than 15 minutes Can dived into water for a long time Dust-pro (dust could not be introduced to the inner part.) SoggyProtectionClass 2 1kg/cm 1m 1m International Protection
  5. 5. Naming System of Load Cell / Force Transducers 2 1kg/cm 3m Naming System of Weighing Assembly UNITED STATES TEL: 800-637-0529 WWW.BRECKNELLSCALES.COM UNITED KINGDOM TEL: + 44 (0) 845 246 6717 WWW.BRECKNELLSCALES.CO.UK UNITED STATES TEL: 800-637-0529 WWW.BRECKNELLSCALES.COM UNITED KINGDOM TEL: + 44 (0) 845 246 6717 WWW.BRECKNELLSCALES.CO.UK Material: H: Alloy Steel B: Stainless Steel L: Aluminum Accuracy: N3: NTEP 3000 Division N5: N10: G1: 0.1% Accuracy G2: 0.2% Accuracy G3: 0.3% Accuracy NTEP 5000 Division NTEP 10,000 Division C1: OIML Certified 1000 Division C2: OIML Certified 2000 Division C3: OIML Certified 3000 Division C3D: OIML Certified 2500 Division C3G: OIML Certified 4000 Division Sealing: No mark: Adhesive potted M: Hermetic welded XXXXX XX X XXXXX d: Digital load cell t: High temperature working Different Series of Appearance: A, B, C, D, E, E3, F, G, G5, H,H5, J, L, N, Q, OC3, W Thread: No mark: Metric Y: Imperial Type & Structure: 2: Spoke Type 3: S-Beam 6: Single Point 8: Single Shear Beam 9: Dual Shear Beam 11: Single Point with Bellow 14: Column type 16: Dual Parallel Beam Capacity: lb: Pounds (lb) K: Klb Kg: Kilograms t: Metric tons N: Newtons KN: Kilo Newtons MN: Million Newtons SE: Small Envelope LE: Large Envelope Material: H: Alloy Steel B: Stainless steel L: Aluminum Assembled Load Cell Type: 2: Spoke Type 3: S-Beam 6: Single Point 8: Single Shear Beam 9: Dual Shear Beam 11: Single Point with Bellow 14: Column type 16: Dual Parallel Beam Structure: J: Foot Y: Load button D: Plate L: Ring M: Mounting XX XX XXX XX / XX Series Number: Defined by number or letter Capacity Range Load Cell Protection Class Reference to National Standard of the Cover Protection Class System (P.R.C.) Equal to IEC529 Standard (International Electrotechnical Commission IP-6- Protection Level Class Description Meanings Experimental Method Achieved Protection Class 5 6 7 8 Adhesive sealed common load cell could achieve Cover sealed inner adhesive protected load cells could achieve Cover (or bellow) welded, inner adhesive protected load cells could achieve. Besides of oil-proof, water proof, it also can proof the common corrosive gas and medium Special required load cells could be customized Water- sprinkle proof Not be affected by the water-sprinkle from any direction in a short time Not be affected by the strong water-spray from any direction in a short time Not be affected by the inundating into water in a stated pressure and time Can dived into water for a long time Water- sprayed protection Soggy Proof Diving Proof Decided individually Inundate into 1 meter deep water for 30 minutes Continually spray water from any direction more than 15 minutes Continually spray water from any direction more than 15 minutes Can dived into water for a long time Dust-pro (dust could not be introduced to the inner part.) SoggyProtectionClass 2 1kg/cm 1m 1m International Protection
  6. 6. Table of Contents - Numeric H2F H3 H3F B3G H3G BM3 L3V L6B L6C L6D L6D21 L6E B6E H6E L6E3 B6E3 L6F B6F H6F L6G B6G H6G H6G5 L6H5 L6J L6J1 L6L L6N B6N L6Q B6Q L6T L6W 38 39 40 BM6A BM6E BM6G 41 42 43 HM8 H8C HM8C 44 45 46 B8D BM8D H8H 47 48 49 50 51 BM8H H8Q B8Q B9B1 HM9B 52 55 56 53 54 57 58 59 60 61 62 63 65 64 66 67 68 69 70 71 72 B9C H9C HM9C B9D H9D B9E HM9E B9F B9H H9H B9N H9N BM11 HM11 BM14A BM14C HM14C BM14D BM14G HM14H BM14K Accessories 97 97 98 98 99 100 100 101 101 102 102 HL-3-001 HL-3-002 HL-3-003 HL-3-004 HL-3-005 HJ-8-201 BJ-8-202 HJ-8-203 BJ-8-205 BJ-8-206 BJ-8-207 103HJ-8-213 103 104 104 105 105 106 BJ-8-215 HJ-8-216 HJ-8-217 HJ-8-218 BJ-8-219 BJ-8-220 106 107 107 HD-8-301 HY-8-101 HY-8-102 108BY-8-104 108BY-8-106 111 112 HY-14-104 BY-14-105 110 111 BY-14-102 BY-14-103 Junction box 133 134 135 136 137 JB01 JB02 JB05A JB06 JB07 Transmitter 138 139 140 FD-3 FD-4 FD-5 5BM24R Miniature Sensors 73 74 75 76 78 79 80 81 82 1A 1B IF6-S 1HM 1R1-K 1V3-350 1X1 1Z 2A 83 84 85 2C1 2F 004-G 86 87 88 CF-1 Q45X10 Q45X6 89 90 91 Q70X5 Q84X5 S6400 92DB-1 771P Series 93DB-2 93DB-2 94FAB 95YA-6 96YA-7 109BY-14-101 H2F H3 H3F B3G H3G BM3 L3V L6B L6C L6D L6D21 L6E B6E H6E L6E3 B6E3 L6F B6F H6F L6G B6G H6G H6G5 L6H5 L6J L6J1 L6L L6N B6N L6Q B6Q L6T L6W 38 39 40 BM6A BM6E BM6G 41 42 43 HM8 H8C HM8C 44 45 46 B8D BM8D H8H 47 48 49 50 51 BM8H H8Q B8Q B9B1 HM9B 52 55 56 53 54 57 58 59 60 61 62 63 65 64 66 67 68 69 70 71 72 B9C H9C HM9C B9D H9D B9E HM9E B9F B9H H9H B9N H9N BM11 HM11 BM14A BM14C HM14C BM14D BM14G HM14H BM14K Accessories 97 97 98 98 99 100 100 101 101 102 102 HL-3-001 HL-3-002 HL-3-003 HL-3-004 HL-3-005 HJ-8-201 BJ-8-202 HJ-8-203 BJ-8-205 BJ-8-206 BJ-8-207 103HJ-8-213 103 104 104 105 105 106 BJ-8-215 HJ-8-216 HJ-8-217 HJ-8-218 BJ-8-219 BJ-8-220 106 107 107 HD-8-301 HY-8-101 HY-8-102 108BY-8-104 108BY-8-106 111 112 HY-14-104 BY-14-105 110 111 BY-14-102 BY-14-103 Junction box 133 134 135 136 137 JB01 JB02 JB05A JB06 JB07 Transmitter 138 139 140 FD-3 FD-4 FD-5 5BM24R Miniature Sensors 73 74 75 76 78 79 80 81 82 1A 1B IF6-S 1HM 1R1-K 1V3-350 1X1 1Z 2A 83 84 85 2C1 2F 004-G 86 87 88 CF-1 Q45X10 Q45X6 89 90 91 Q70X5 Q84X5 S6400 92DB-1 771P Series 93 DB-2 93 DB-2 94FAB 95YA-6 96YA-7 109BY-14-101 Table of Contents - Alpha
  7. 7. Table of Contents - Numeric H2F H3 H3F B3G H3G BM3 L3V L6B L6C L6D L6D21 L6E B6E H6E L6E3 B6E3 L6F B6F H6F L6G B6G H6G H6G5 L6H5 L6J L6J1 L6L L6N B6N L6Q B6Q L6T L6W 38 39 40 BM6A BM6E BM6G 41 42 43 HM8 H8C HM8C 44 45 46 B8D BM8D H8H 47 48 49 50 51 BM8H H8Q B8Q B9B1 HM9B 52 55 56 53 54 57 58 59 60 61 62 63 65 64 66 67 68 69 70 71 72 B9C H9C HM9C B9D H9D B9E HM9E B9F B9H H9H B9N H9N BM11 HM11 BM14A BM14C HM14C BM14D BM14G HM14H BM14K Accessories 97 97 98 98 99 100 100 101 101 102 102 HL-3-001 HL-3-002 HL-3-003 HL-3-004 HL-3-005 HJ-8-201 BJ-8-202 HJ-8-203 BJ-8-205 BJ-8-206 BJ-8-207 103HJ-8-213 103 104 104 105 105 106 BJ-8-215 HJ-8-216 HJ-8-217 HJ-8-218 BJ-8-219 BJ-8-220 106 107 107 HD-8-301 HY-8-101 HY-8-102 108BY-8-104 108BY-8-106 111 112 HY-14-104 BY-14-105 110 111 BY-14-102 BY-14-103 Junction box 133 134 135 136 137 JB01 JB02 JB05A JB06 JB07 Transmitter 138 139 140 FD-3 FD-4 FD-5 5BM24R Miniature Sensors 73 74 75 76 78 79 80 81 82 1A 1B IF6-S 1HM 1R1-K 1V3-350 1X1 1Z 2A 83 84 85 2C1 2F 004-G 86 87 88 CF-1 Q45X10 Q45X6 89 90 91 Q70X5 Q84X5 S6400 92DB-1 771P Series 93DB-2 93DB-2 94FAB 95YA-6 96YA-7 109BY-14-101 H2F H3 H3F B3G H3G BM3 L3V L6B L6C L6D L6D21 L6E B6E H6E L6E3 B6E3 L6F B6F H6F L6G B6G H6G H6G5 L6H5 L6J L6J1 L6L L6N B6N L6Q B6Q L6T L6W 38 39 40 BM6A BM6E BM6G 41 42 43 HM8 H8C HM8C 44 45 46 B8D BM8D H8H 47 48 49 50 51 BM8H H8Q B8Q B9B1 HM9B 52 55 56 53 54 57 58 59 60 61 62 63 65 64 66 67 68 69 70 71 72 B9C H9C HM9C B9D H9D B9E HM9E B9F B9H H9H B9N H9N BM11 HM11 BM14A BM14C HM14C BM14D BM14G HM14H BM14K Accessories 97 97 98 98 99 100 100 101 101 102 102 HL-3-001 HL-3-002 HL-3-003 HL-3-004 HL-3-005 HJ-8-201 BJ-8-202 HJ-8-203 BJ-8-205 BJ-8-206 BJ-8-207 103HJ-8-213 103 104 104 105 105 106 BJ-8-215 HJ-8-216 HJ-8-217 HJ-8-218 BJ-8-219 BJ-8-220 106 107 107 HD-8-301 HY-8-101 HY-8-102 108BY-8-104 108BY-8-106 111 112 HY-14-104 BY-14-105 110 111 BY-14-102 BY-14-103 Junction box 133 134 135 136 137 JB01 JB02 JB05A JB06 JB07 Transmitter 138 139 140 FD-3 FD-4 FD-5 5BM24R Miniature Sensors 73 74 75 76 78 79 80 81 82 1A 1B IF6-S 1HM 1R1-K 1V3-350 1X1 1Z 2A 83 84 85 2C1 2F 004-G 86 87 88 CF-1 Q45X10 Q45X6 89 90 91 Q70X5 Q84X5 S6400 92DB-1 771P Series 93 DB-2 93 DB-2 94FAB 95YA-6 96YA-7 109BY-14-101 Table of Contents - Alpha
  8. 8. H2A · Capacities:1MN~ 5MN · Alloy steel construction · High reliability and long life span MN 1/2/3/4/5 G2 0.2% 0.05% 0.1% 0.1% ≥2.0 1072±5 1050±5 ≥5000(50VDC) 1.0 -10~ +40 -35~ +70 5~ 12(DC) 18(DC) 150 300 Output (+) Green Input (-) Black Output (-) White Input (+) Red Wiring: hielded, 4 conductor cable: Φ5mm Standard cable length: 5m S Capacity(MN) Dimension D D1 D2 H H1 1 2 3 4 5 41 (1.61) 60 (2.36) 73 (2.87) 92 (3.62) 115 (4.53) 260 (10.24) 290 (11.42) 330 (12.99) 400 (15.75) 400 (15.75) 200 (7.87) 225 (8.86) 251 (9.88) 296 (11.65) 307 (12.09) 80 (3.15) 104 (4.09) 123 (4.84) 132 (5.20) 132 (5.20) 10 (0.39) 10 (0.39) 10 (0.39) 10 (0.39) 10 (0.39) Specifications ΦD 4-M16 depth 20(0.79) Equipartion H ΦD1 ΦD2 H1 10(0.39) 1 · H2A load cells are available in the manifold accurate measurement in the capacities 1MN to 5MN. · Alloy steel,surface bluing treatment, spray painted, oil-proof, waterproof and anti-corrosion, suitable for groundsill measuring and other engineering measuring fields. · Spoke type, easy installation, suitable for special force measuring equipments. · Safety and anti-explosive product, can be used in atrocious environments and hazardous areas. Capacity Accuracy Combined error Creep Temperature effect on sensitivity Temperature effect on zero Output sensitivity Input resistance Output resistance Insulation resistance Zero balance Temperature, compensated Temperature, operating Excitation, recommended Excitation, max Safe overload Ultimate overload (%FS) (%FS/30min) (%FS/10℃) (%FS/10℃) (mv/v) (Ω) (Ω) (MΩ) (%FS) (℃) (℃) (V) (V) (%FS) (%FS) Outline Dimension mm(inch) Features UNITED STATES TEL: 800-637-0529 WWW.BRECKNELLSCALES.COM UNITED KINGDOM TEL: + 44 (0) 845 246 6717 WWW.BRECKNELLSCALES.CO.UK G3 0.3% 0.05% 0.2% 0.2%
  9. 9. Outline Dimension mm(inch) H2D · H2D load cells are available for manifold accurate measurement in the capacities 5t~ 20t. · Alloy steel, sealed by adhesive, oil-proof, waterproof and anti-corrosion, suitable for all kinds of environments. · Spoke type, easy installation, suitable for crane scale, hopper scale and other electronic weighing devices. · Safe and anti-explosive product, can be used in atrocious environment and hazardous areas. · Capacity: 5t~ 20t · Alloy steel construction · High accuracy 5/10/20 C2 2000 Emax/5000 ≤±0.030 ≤±0.023 ≤±0.017 ≤±0.029 2.0±0.008 750±10 700±7 ≥5000(50VDC) 1.0 -10~ +40 -35~ +70 5~ 12(DC) 18(DC) 150 300 Output (+) Green Input (-) Black Output (-) White Input (+) Red Wiring: Five-wire connector hielded, 4 conductor cable: Φ5mm Standard cable length: 5m(5t,10t),10m(20t) S D D1 M H Capacityt() Dimension (mm) 5 10 20 L 83 (3.27) 128 (5.04) 45 (1.77) M24×2 8 (0.31) 150 (5.91) 160 (6.03) 60 (2.36) M39×2 30 (1.18) 220 (8.66) 200 (7.78) 80 (2.99) M60×2 60 (2.36) t Specifications M 25 (0.98) L H 52 (2.05) ΦD ΦD1 2 Capacity Accuracy Maximum number of verification intervals Minimum load cell verification interval Combined error Creep Temperature effect on sensitivity Temperature effect on zero Output sensitivity Input resistance Output resistance Insulation resistance Zero balance Temperature, compensated Temperature, operating Excitation, recommended Excitation, max Safe overload Ultimate overload nmax vmin (%FS) (%FS/30min) (%FS/10℃) (%FS/10℃) (mv/v) (Ω) (Ω) (MΩ) (%FS) (℃) (℃) (V) (V) (%FS) (%FS) Features CANADA TEL: 416-213-9900 WWW.BRECKNELLSCALES.CA INDIA TEL: +91 129 4159774/75/76 WWW.SALTERINDIA.COM
  10. 10. HM2D4 Accuracy Maximum number of verification intervals Minimum load cell verification interval Combined error Creep Temperature effect on sensitivity Temperature effect on zero Output sensitivity Input resistance Output resistance Insulation resistance Zero balance Temperature, compensated Temperature, operating Excitation, recommended Excitation, max Safe overload Ultimate overload tCapacity C3 2000 Emax/5000 ≤±0.030 ≤±0.024 ≤±0.017 ≤±0.023 2.0±0.002 350±3 351±2 ≥5000(50VDC) 1.0 -10~ +40 -35~ +70 5~ 12(DC) 18(DC) 150 300 Features · Capacity: 0.5t~ 50t · High accuracy · Alloy steel construction · Low profile Outline Dimension mm(inch) Wiring: Shielded, 6 conductor cable: Φ5.6mm Standard cable length: 5m · · · HM2D4 load cells are available for manifold accurate measurement in the capacities 0.5t~ 20t. Alloy steel, completely welded, oil-proof, waterproof and anti-corrosive gas and medium, suitable for all kinds of environments. Spoke type, suitable for electronic truck scales, hopper scales, automotive testing equipments, and other electronic weighing or force measuring fields. 0.5/1/2/3/5/10/20/50 Output (+) White Sense (-) Blue Output (-) Red Input (+) Green Input (-) Black Sense (+) Yellow 0.5t~2t D 105 (4.13) 28 (1.10) 70 (2.76) Dimension (mm) Capacity(t) 3t,5t 10t,20t D1 H M 120 (4.72) 155 (6.10) 33 (1.3) 60.5 (2.38) 90 (3.54) 80 (3.15) M14×2 M20×1.5 M32×2 IP68 50 (1.97) ΦD1 25 (0.98) 30 (0.18) H ΦD M Specifications 3 nmax vmin (%FS) (%FS/30min) (%FS/10℃) (%FS/10℃) (mv/v) (Ω) (Ω) (MΩ) (%FS) (℃) (℃) (V) (V) (%FS) (%FS) UNITED STATES TEL: 800-637-0529 WWW.BRECKNELLSCALES.COM UNITED KINGDOM TEL: + 44 (0) 845 246 6717 WWW.BRECKNELLSCALES.CO.UK 50t 200 (7.87) 75 (2.95) 120 (4.72) M45×3
  11. 11. H2F · H2F load cells are available for manifold accurate measurement in the capacities 1t~ 50t. · Alloy steel, potted with adhesive inside, oil-proof, waterproof and anti-corrosion, suitable for all kinds of environments. · Spoke type, easy installation, suitable for electronic truck scales, hopper scales and other electronic weighing devices. · Safe and anti-explosive product, can be used in atrocious environment and hazardous areas. Features · Capacity: 1t~ 50t · Alloy steel construction · High accuracy C1 1000 Emax/3000 ≤±0.050 ≤±0.038 ≤±0.028 ≤±0.047 C2 2000 Emax/5000 ≤±0.030 ≤±0.023 ≤±0.017 ≤±0.029 2.0±0.01 770±30 700±5 ≥5000(50VDC) 1.5 -10~ +40 -35~ +70 5~ 12(DC) 18(DC) 150 300 Output (+) Blue Sense (-) Black Output (-) White Input (+) Red Input (-) Yellow Sense (+) Brown Wiring: hielded, 6 conductor cable: Φ6mm Standard cable length: 3m(1~3t),4m(5~10t),15m(15~50t) S Capacity(t) Dimension(mm) Capacity Accuracy Maximum number of verification intervals Minimum load cell verification interval Combined error Creep Temperature effect on sensitivity Temperature effect on zero Output sensitivity Input resistance Output resistance Insulation resistance Zero balance Temperature, compensated Temperature, operating Excitation, recommended Excitation, max Safe overload Ultimate overload t Specifications D D1 D2 H H1 H2 WL 1 2 3 5 10 15 20 30 50 115 (4.53) 22 (0.87) 86 (3.39) 43 (1.69) 12 (0.47) 5 (0.2) 8 (0.31) 8.4 (0.33) 120 (4.72) 26 (1.02) 128 (5.04) 160 (6.3) 128 (5.04) 194 (7.64) 220 (8.66) 230 (9.06) 264 (10.39) 20 (0.79) 20 (0.79) 40 (1.57) 42 (1.65) 44 (1.73) 48 (1.89) 52 (2.05) 90 (3.54) 100 (3.94) 100 (3.94) 120 (4.72) 154 (6.06) 170 (6.69) 188 (7.4) 214 (8.43) 45 (1.77) 46 (1.81) 63 (2.48) 73 (2.87) 78 (3.07) 90 (3.54) 68 (2.68) 46 (1.81) 12 (0.47) 8 (0.31) 8 (0.31) 15 (0.59) 20 (0.79) 22 (0.87) 25 (0.98) 30 (1.18) 5 (0.2) 5 (0.2) 10 (0.39) 10 (0.39) 10 (0.39) 10 (0.39) 10 (0.39) 5 (0.2) 8 (0.31) 7 (0.28) 7 (0.28) 10 (0.39) 12 (0.47) 12 (0.47) 12 (0.47) 12 (0.47) 8.4 (0.33) 10.4 (0.41) 10.4 (0.41) 10.4 (0.41) 12.4 (0.49) 12.4 (0.49) 12.4 (0.49) 12.4 (0.49) Accessory · HM-2-401 · BM-2-402 ΦD2 H2 ΦD H1 4-W 4-L 45° 45° ΦD1 4 nmax vmin (%FS) (%FS/30min) (%FS/10℃) (%FS/10℃) (mv/v) (Ω) (Ω) (MΩ) (%FS) (℃) (℃) (V) (V) (%FS) (%FS) Outline Dimension mm(inch) CANADA TEL: 416-213-9900 WWW.BRECKNELLSCALES.CA INDIA TEL: +91 129 4159774/75/76 WWW.SALTERINDIA.COM H 1/2/3/5/10/15/20/30/50
  12. 12. · · hazardous BM24R applied a ring type, suitable for all kinds of platform scales and dynamic weighing system. Stainless steel, Hermetically sealed IP68,low profile load cell for all kinds of applications. Features · Capacity: 60kg-60t High accuracy OIML Cert. No.: R60/2000-NL-11.21 NTEP Cert. No.: 11-103A1 · · · BM24R BM24R 60kg-280kg Accessory: BJ-24-202 BM-24-401 BM24R 250kg-13t BJ-24-203 BJ-24-204 BM-24-402 BM-24-403 BM24R-28t-60t BJ-24-205 Capacity Accuracy Maximum number of verification intervals Minimum load cell verification interval Combined error Creep Temperature effect on sensitivity Temperature effect on zero Output sensitivity Input resistance Output resistance C3 3000 Emax/10000 ≤±0.0230 ≤±0.0245 ≤±0.0117 ≤±0.0140 Specifications 60kg / 130kg / 250kg / 280kg / 500kg / 1t / 2t / 3.5t / 5t/ 10t / 13t / 28t / 60t nmax vmin (%FS) (%FS/30min) (%FS/10℃) (%FS/10℃) (mv/v) (Ω) (Ω) (%FS) 60kg / 130kg / 280kg 1.0±0.1 250kg 1.75±0.1 2.0±0.1 60kg / 130kg / 280kg 1260±100 500kg 60t~ 250kg / 500kg 10t~ 1100±100 13t 1200±100 28t 60t 1075±100 1350±100 60kg / 130kg / 280kg 1020±0.5 250kg / 500kg 10t~ 13t 28t 60t 1025±25 1000±0.5 930±0.5 1175±0.5 Insulation resistance Zero balance Temperature, compensated Temperature, operating Excitation, recommended Excitation, max Safe overload Ultimate overload (MΩ) (%FS) (℃) (℃) (V) (V) (%FS) (%FS) ≥5000(50VDC) 1.0 -10 +40~ -30 +70~ 5 12(DC)~ 15(DC) 150 300 Nm 60kg / 130kg / 280kg 8 250kg / 500kg 10t~ 13t 28t 60t 10 - - - Recommended torque on fixation bolts Protection class IP68 Outline Dimension mm(inch) Wiring: S ± hielded, 4 conductor cable: Φ6.2mm 0.1mm Dim. Capacity ΦA ΦB C D E ΦF G H I J ΦK SR 60kg / 130kg / 280kg 63 15.1 22 11 60 54 6 10 Φ3.2 -- -- -- 0.25t/0.5t/1t 80 19 25 12.5 65 71 10 18 M10 1 25 -- 2t / 3.5t 80 19 30 12.5 65 71 10 18 Φ15 6 25 -- 10t 95 26 35 12.5 72 75 20.7 31.2 -- -- 29 -- 13t 95 26 35 20 85 79.5 20 31 -- -- 29 -- 28t 120 35.9 46 25 94 102 -- 53 -- -- -- 400 60t 140 47.9 62 34 104 124 -- 69 -- -- -- 600 Capacity Cable length 60kg 3m 130kg 250kg 280kg 500kg 1t 2t 6m3.5t 5t 10t 15m 13t 28t 60t 5 UNITED STATES TEL: 800-637-0529 WWW.BRECKNELLSCALES.COM UNITED KINGDOM TEL: + 44 (0) 845 246 6717 WWW.BRECKNELLSCALES.CO.UK To order call (919) 776-7737 or visit www.CentralCarolinaScale.com
  13. 13. 25kg-5t L 2-M H W1 0.1-20klb H1 2Places 7.5t-30t L 2-M H H1 2Places H3 Accuracy Approvals Maximum number of verification intervals Minimum load cell verification interval Combined error Creep Temperature effect on sensitivity Temperature effect on zero Output sensitivity Input resistance Output resistance Insulation resistance Zero balance Temperature, compensated Temperature, operating Excitation, recommended Excitation, max Safe overload Ultimate overload t lb Capacity 25kg/50kg/100kg/150kg/200kg/250kg/300kg/500kg/600kg/750kg/1t/1.5t/2t/2.5t/3t/5t/7.5t/10t/15t/20t/30t 100/150/200/250/300/500/750/1K/1.5K/2K/2.5K/3K/5K/10K/15K/20K C3 OIML R60 C3 3000 Emax/10000 ≤±0.020 ≤±0.016 ≤±0.011 ≤±0.015 N10 10000 Emax/10000 ≤±0.20 ≤±0.020 ≤±0.014 ≤±0.017 2.0±0.004(Metric) 3.0±0.008(Imperial) 350±3.5 351±2.0 ≥5000(50VDC) 1.5(Metric) 1.0(Imperial) -10~ +40 -35~ +70 5~ 12(DC) 18(DC) 150 300 · H3 load cells are available in the capacities 25kg~ 30t and 100lb~ 20Klb. · Alloy steel, sealed by adhesive inside, oil-proof, waterproof and anti-corrosion, suitable for all kinds of environments. · S beam design, tension and/or compression loading possible, easy installation, suitable for crane scale, mechanical conversion scale, hopper scale and other electronic weighing devices. · Safe and anti-explosive product, can be used in atrocious environment and hazardous areas. Features · Capacity: 25kg~ 30t ; 100lb~ 20Klb · High accuracy · Alloy steel construction · Low profile · OIML Certificates No:R60/2000-CN-00.01 · PTB Approval No:D09-03.18 Revision 2 · NTEP Certificates No:CC06-099A1 Accessory · HL-3-001 · HL-3-002 · HL-3-003 · HL-3-004· HL-3-005 Specifications Outline Dimension mm(inch) Wiring: Shielded, 4 conductor cable: Φ5mm Standard cable length: 3m(0.025t~0.75t), 6m(1t~30t)(0.1klb~20klb) Output (+) Green Input (-) Black Output (-) White Input (+) Red W1 W MCapacity Dimension(mm) H1±0.4 25kg~50kg 0.1t~0.15t 0.2t~0.75t 1t~1.5t 2t~5t 7.5t~10t 15t~20t 30t 100lb~300lb 500lb 0.75klb~1.5klb 2klb~2.5klb 3klb 5klb~10klb 15klb 20klb 15.7(0.62) 10.16(0.4) 15.3(0.60) 15.3(0.60) 12.1(0.48) 76.2(3.0) 76.2(3.0) 76.2(3.0) 76.2(3.0) 101.6(4.0) 175(6.89) 200(7.89) 230(9.06) 63.5(2.5) 63.5(2.5) 63.5(2.5) 63.5(2.5) 101.6(4.0) 101.6(4.0) 139.7(5.5) 177.8(7.0) 50.8(2.0) 50.8(2.0) 50.8(2.0) 50.8(2.0) 76.2(3.0) 125(4.92) 160(6.3) 190(7.48) 50.8(2.0) 50.8(2.0) 50.8(2.0) 50.8(2.0) 76.2(3.0) 76.2(3.0) 101.6(4.0) 127(5.0) 12.7(0.5) 19.0(0.75) 19.0(0.75) 25.4(1.0) 25.4(1.0) 50(1.97) 60(2.36) 80(3.15) 12.7(0.5) 19.05(0.75) 19.05(0.75) 25.4(1.0) 25.4(1.0) 25.4(1.0) 31.75(1.25) 50.8(2.0) 16.1(0.63) 22.4(0.88) 22.4(0.88) 28.8(1.13) 28.8(1.13) / / / 15.9(0.63) 22.25(0.88) 22.25(0.88) 28.6(1.13) 28.6(1.13) 28.6(1.13) 34.95(1.38) 54(2.13) M8 M10×1.5 M10×1.5 M12×1.75 M20×1.5 M33×3 M42×3 M42×3 1/4-28UNF 1/2-20UNF 1/2-20UNF 1/2-20UNF 1/2-20UNF 3/4-16UNF 1-14UNS 20(0.79) 40.2(1.58) 51(2.01) 57.5(2.26) 15.24(0.6) 31(1.22) 39.9(1.57) 15.24(0.6) W W1 5 (%FS) (%FS/30min) (%FS/10℃) (%FS/10℃) (mv/v) (Ω) (Ω) (MΩ) (%FS) (℃) (℃) (V) (V) (%FS) (%FS) nmax vmin H L 6 CANADA TEL: 416-213-9900 WWW.BRECKNELLSCALES.CA INDIA TEL: +91 129 4159774/75/76 WWW.SALTERINDIA.COM Central Carolina Scale, Inc 5393 Farrell Road Sanford NC 27330 PH: 919-776-7737 www.CentralCarolinaScale.com
  14. 14. H3F Accuracy Maximum number of verification intervals Minimum load cell verification interval Combined error Creep Temperature effect on sensitivity Temperature effect on zero Output sensitivity Input resistance Output resistance Insulation resistance Zero balance Temperature, compensated Temperature, operating Excitation, recommended Excitation, max Safe overload Ultimate overload t lb Capacity C3 3000 Emax/10000 ≤±0.020 ≤±0.016 ≤±0.011 ≤±0.015 N5 5000 Emax/5000 ≤±0.020 ≤±0.020 ≤±0.017 ≤±0.020 3.0±0.008 350±3.5 351±2.0 ≥5000(50VDC) 1.0 -10~ +40 -35~ +70 5~ 12(DC) 18(DC) 150 300 · H3F load cells are available in the capacities 0.1t~ 5t and 250lb~ 20Klb. · Alloy steel, sealed by adhesive inside, oil-proof, waterproof and anti-corrosion, suitable for all kinds of environments. · S beam design, tension and/or compression loading possible, easy installation, suitable for crane scale, mechanical conversion scale, hopper scale and other electronic weighing devices. · Safe and anti-explosive product, can be used in atrocious environment and hazardous areas. Features · Capacity: 0.1t~ 5t;250lb~ 20Klb · High accuracy · Alloy steel construction · Low profile · NTEP Certificates No:CC06-099A1 Accessory · HL-3-001 · HL-3-002 · HL-3-003 · HL-3-004· HL-3-005 Specifications Outline Dimension mm(inch) 100kg/250kg/500kg/750kg/1t/1.5t/2t/2.5t/5t 250/500/750/1K/1.5K/2K/2.5K/3K/5K/7.5K/10K/15K/20K Capacity Dimension mm 100kg 250kg 500kg 750kg 1000kg 1500kg 2000kg 2500kg 5000kg 250lb 500lb 750lb 1klb 1.5klb 2klb 2.5klb 3klb 5klb 7.5klb 10klb 15klb 20klb 76.2(3) 76.2(3) 76.2(3) 76.2(3) 76.2(3) 76.2(3) 108(4.25) 108(4.25) 108(4.25) 76.2(3) 76.2(3) 76.2(3) 76.2(3) 76.2(3) 76.2(3) 76.2(3) 76.2(3) 108(4.25) 108(4.25) 108(4.25) 140(5.51) 177.8(7) 25.4(1.0) 25.4(1.0) 25.4(1.0) 25.4(1.0) 31.8(1.25) 31.8(1.25) 31.8(1.25) 31.8(1.25) 31.8(1.25) 19(0.75) 25.4(1.0) 25.4(1.0) 25.4(1.0) 25.4(1.0) 31.8(1.25) 31.8(1.25) 31.8(1.25) 31.8(1.25) 31.8(1.25) 31.8(1.25) 38.1(1.31) 50.8(2.0) 19(0.75) 19(0.75) 19(0.75) 19(0.75) 25.4(1) 25.4(1) 25.4(1) 25.4(1) 25.4(1) 12.7(0.5) 19(0.75) 19(0.75) 19(0.75) 19(0.75) 25.4(1) 25.4(1) 25.4(1) 25.4(1) 25.4(1) 25.4(1) 31.8(1.25) 49.3(1.94) 50.8(2) 50.8(2) 50.8(2) 50.8(2) 50.8(2) 50.8(2) 76.2(3) 76.2(3) 76.2(3) 50.8(2) 50.8(2) 50.8(2) 50.8(2) 50.8(2) 50.8(2) 50.8(2) 50.8(2) 76.2(3) 76.2(3) 76.2(3) 100(3.94) 125.5(4.94) 15.8(0.62) 15.12(0.6) 14.2(0.56) 13.46(0.53) 13.24(0.52) 12.1(0.48) 26.7(1.05) 25.48(1) 20.26(0.8) 15.69(0.62) 15.25(0.6) 14.95(0.59) 14.4(0.57) 13.75(0.54) 13.4(0.53) 13.03(0.51) 12.39(0.49) 27.18(1.07) 25.78(1.01) 23.88(0.94) 31(1.22) 39.9(1.57) M10×1.5 M12×1.75 M12×1.75 M12×1.75 M12×1.75 M12×1.75 M18×1.5 M18×1.5 M18×1.5 3/8-24UNF-2B 1/2-20UNF-2B 1/2-20UNF-2B 1/2-20UNF-2B 1/2-20UNF-2B 1/2-20UNF-2B 1/2-20UNF-2B 1/2-20UNF-2B 3/4-16UNF-2B 3/4-16UNF-2B 3/4-16UNF-2B 1-14UNS-2B 1-1/4-12UNF-2B Output (+) Green Input (-) Black Output (-) White Input (+) Red Shielded, 4 conductor cable: Φ5mm Standard cable length: 6m Wiring: H W W1 L H1 MW1 H 2-M-6H L H1 (2Places) W nmax vmin (%FS) (%FS/30min) (%FS/10℃) (%FS/10℃) (mv/v) (Ω) (Ω) (MΩ) (%FS) (℃) (℃) (V) (V) (%FS) (%FS) 7 UNITED STATES TEL: 800-637-0529 WWW.BRECKNELLSCALES.COM UNITED KINGDOM TEL: + 44 (0) 845 246 6717 WWW.BRECKNELLSCALES.CO.UK
  15. 15. B3G t lb Capacity C3 OIMLR60 C3 3000 Emax/10000 ≤±0.020 ≤±0.016 ≤±0.011 ≤±0.015 N3 3000 Emax/3000 ≤±0.030 ≤±0.030 ≤±0.020 ≤±0.025 3.0±0.008 430±60 351±2.0 ≥5000(50VDC) 1.0 -10~ +40 -35~ +70 5~ 12(DC) 18(DC) 150 300 Features · Capacity:50kg~ 10t ;50lb~ 20Klb · · · · R60/2000-CNI-06.02 · D09-06.07 · NTEP Certificates No:CC06-099A1 High accuracy Stainless steel construction Low profile OIML Certificates No: PTB Approval No: Accessory · HL-3-001 · HL-3-002 · HL-3-003 · HL-3-004· HL-3-005 Specifications Outline Dimension mm(inch) Wiring: Shielded, 4 conductor cable: Φ5mm Standard cable length: 6m Output (+) Green Input (-) Black Output (-) White Input (+) Red 50kg/100kg/250kg/500kg/1t/2.5t/5t/7.5t/10t 50/75/100/150/200/250/300/500/750/1K/1.5K/2K/2.5K/3K/5K/10K/15K/20K · B3G load cells are available in the capacities 50kg~ 10t and 50lb~ 20Klb. · Stainless steel, sealed by adhesive inside, oil-proof, waterproof and anti-corrosion, suitable for all kinds of environments. · S beam design, tension and/or compression loading possible, easy installation, suitable for crane scale,mechanical conversion scale, hopper scale and other electronic weighing devices. · Safe and anti-explosive product, can be used in atrocious environment and hazardous areas. 50.8 (2.0) 11.68 (0.46) 15.06 (0.59) 50.8 (2.0) 18.03 (0.71) 21.4 (0.84) 50.8 (2.0) 24.38 (0.96) 27.76 (1.09) Dimension mm M8 1/4-28UNF 74.68 (2.94) 87.38 (3.44) 37.08 (1.46) 40.46 (1.59) 112.78 (4.44) 42.93 (1.69) 46.31 (1.82) M12 1/2-20UNF M12 1/2-20UNF M20×1.5 1/2-20UNF M20×1.5 3/4-16UNF M24×2 1-14UNS 60.96 (2.4) 139.7 (5.5) 177.8 (7.0) 99.06 (3.9) 30.74 (1.21) 34.12 (1.34) Capacity L H WW1 M H1 50kg,100kg 50lb~300lb 250kg,500kg 500lb~1.5 lb 1t 2,2.5klb 2.5t 3klb 5t 10klb 7.5t 15klb 10t 20klb k 76.2 (3.0) 5klb 76.2 (3.0) 60.96 (2.4) 60.96 (2.4) 99.06 (3.9) 99.06 (3.9) 24.38 (0.96) 24.38 (0.96) 27.76 (1.09) 27.76 (1.09) M30×2 -12UNS1-1 4 3/4-16UNF 8.89 (0.35) 13.97 (0.55) 18.37(0.72) 15.75(0.62) 27.5 (1.08) 39.9 (1.57) 13.97 (0.55) W2-M L H H1 2Places W1 7 nmax vmin Accuracy Approvals Maximum number of verification intervals Minimum load cell verification interval Combined error Creep Temperature effect on sensitivity Temperature effect on zero Output sensitivity Input resistance Output resistance Insulation resistance Zero balance Temperature, compensated Temperature, operating Excitation, recommended Excitation, max Safe overload Ultimate overload (%FS) (%FS/30min) (%FS/10℃) (%FS/10℃) (mv/v) (Ω) (Ω) (MΩ) (%FS) (℃) (℃) (V) (V) (%FS) (%FS) 8 CANADA TEL: 416-213-9900 WWW.BRECKNELLSCALES.CA INDIA TEL: +91 129 4159774/75/76 WWW.SALTERINDIA.COM N10 10000 Emax/10000 ≤±0.020 ≤±0.020 ≤±0.014 ≤±0.017
  16. 16. H 2-M L H1 2Places W H3G Features · Capacity: 50kg~ 10t ; 50lb~ 20Klb · High accuracy · Alloy steel construction · Low profile · NTEP Certificates No:CC06-099A1 · OIML Certificates No:R60/2000-NL1-10.30 Accessory · HL-3-001 · HL-3-002 · HL-3-003 · HL-3-004· HL-3-005 Outline Dimension mm(inch) Wiring: Shielded, 4 conductor cable: Φ5mm Standard cable length: 6m Output (+) Green Input (-) Black Output (-) White Input (+) Red · H3G load cells are available in the capacities 50kg~ 7.5t and 50lb~ 20Klb. · Alloy steel, sealed by adhesive inside, oil-proof, waterproof and anti-corrosion, suitable for all kinds of environments. · S beam design, tension and/or compression loading possible, easy installation, suitable for crane scale,mechanical conversion scale, hopper scale and other electronic weighing devices. · Safe and anti-explosive product, can be used in atrocious environment and hazardous areas. 50.8 (2.0) 12.7 (0.5) 16.07 (0.63) 50.8 (2.0) 19.05 (0.75) 22.43 (0.88) 50.8 (2.0) 25.4 (1.0) 28.78 (1.13) Dimension mm M8 1/4-28UNF 101.6 (4.0) 31.75 (1.25) 35.13 (1.38) 127 (5.0) 50.8 (2.0) 54.6 (2.15) M12 1/2-20UNF M12 1/2-20UNF M20×1.5 1/2-20UNF M20×1.5 3/4-16UNF M24×2 1-14UNS 63.5 (2.5) 139.7 (5.5) 177.8 (7.0) 25.4 (1.0) Capacity L H WW1 M H1 50kg,100kg 50lb~300lb 200kg,500kg 500lb~1.5klb 1t 2,2.5klb 2.5t 3klb 5t 5klb,10klb 7.5t 15klb 76.2 (3.0) 25.4 (1.0) -12UNF1-1 4 10.16 (0.4) 15.2 (0.6) 20(0.79) 15.24(0.6) 39.9 (1.57) 76.2 (3.0) 63.5 (2.5) 63.5 (2.5) 101.6 (4.0) 101.6 (4.0) 28.78 (1.13) 28.78 (1.13) 20klb 30(1.18) 31(1.22) Accuracy Maximum number of verification intervals Minimum load cell verification interval Combined error Creep Temperature effect on sensitivity Temperature effect on zero Output sensitivity Input resistance Output resistance Insulation resistance Zero balance Temperature, compensated Temperature, operating Excitation, recommended Excitation, max Safe overload Ultimate overload t lb Capacity C3 3000 Emax/10000 ≤±0.020 ≤±0.016 ≤±0.011 ≤±0.015 N3 3000 Emax/3000 ≤±0.030 ≤±0.030 ≤±0.020 ≤±0.025 3.0±0.008 430±60 351±2.0 ≥5000(50VDC) 1.0 -10~ +40 -35~ +70 5~ 12(DC) 18(DC) 150 300 Specifications 0.05/0.1/0.25/0.5/1/2.5/5/7.5 50/75/100/150/200/250/300/500/750/1K/1.5K/2K/2.5K/3K/5K/10K/15K/20K W1 8 nmax vmin (%FS) (%FS/30min) (%FS/10℃) (%FS/10℃) (mv/v) (Ω) (Ω) (MΩ) (%FS) (℃) (℃) (V) (V) (%FS) (%FS) 9 UNITED STATES TEL: 800-637-0529 WWW.BRECKNELLSCALES.COM UNITED KINGDOM TEL: + 44 (0) 845 246 6717 WWW.BRECKNELLSCALES.CO.UK N10 10000 Emax/10000 ≤±0.020 ≤±0.020 ≤±0.014 ≤±0.017
  17. 17. W 86 92(3.62) Φ99 2-M-6H Features · Capacity:1t~ 7.5t · High accuracy · Stainless steel construction · Low profile · PTB Approval NO:D09-08.01 · NTEP Certificates No:CC06-099A1 Accessory · HL-3-001 · HL-3-002 · HL-3-003 · HL-3-004· HL-3-005 Outline Dimension mm(inch) Wiring: Shielded, 4 conductor cable: Φ5mm Standard cable length: 3m(500kg), 6m(1t~7.5t) Output (+) Green Input (-) Black Output (-) White Input (+) Red · Bm3 load cells are available in the capacities 1t~ 7.5t. · Stainless steel, hermetically welded, oil-proof, waterproof and anti-corrosion, suitable for all kinds of environments. · S beam design, tension and/or compression loading possible, easy installation, suitable for electronic crane scale, hopper scale and other electronic weighing devices. · Safe and anti-explosive product, can be used in atrocious environment and hazardous areas. Accuracy Maximum number of verification intervals Minimum load cell verification interval Combined error Creep Temperature effect on sensitivity Temperature effect on zero Output sensitivity Input resistance Output resistance Insulation resistance Zero balance Temperature, compensated Temperature, operating Excitation, recommended Excitation, max Safe overload Ultimate overload tCapacity C3 3000 Emax/10000 ≤±0.020 ≤±0.016 ≤±0.011 ≤±0.015 2.0±0.004 350±3.5 351±2.0 ≥5000(50VDC) 1.5 -10~ +40 -35~ +70 5~ 12(DC) 18(DC) 150 300 Specifications 1/2/3/4/5/6 W 32(1.26) 32(1.26) 32(1.26) Dimension(mm) 36(1.42) 50(1.97) 50(1.97) M H Capacity (t) 1.0 2.0-2.5t 3.0 4.0 5.0 6.0 M20×1.5 M20×1.5 M20×1.5 M24×2 M24×2M12×1.75 25(0.98)25(0.98) 25(0.98) 25(0.98) 24(0.94)24(0.94) BM3 H 2Places nmax vmin (%FS) (%FS/30min) (%FS/10℃) (%FS/10℃) (mv/v) (Ω) (Ω) (MΩ) (%FS) (℃) (℃) (V) (V) (%FS) (%FS) Approvals OIML R60 C3 (3.90) (3.39) 10 CANADA TEL: 416-213-9900 WWW.BRECKNELLSCALES.CA INDIA TEL: +91 129 4159774/75/76 WWW.SALTERINDIA.COM
  18. 18. L3V Features · Capacity: 200kg~500kg · Aluminum S beam · High accuracy · High reliability kg · L3V load cells are available in the capacities 200kg and 500kg. · Aluminum material, sealed with silicon adhesive, surface spraying plastic with good resistance against corrosion. · Integral construction, easy installation. · Suitable for textile machinery measuring and other electronic measuring fields. Wiring: Output (+) Green Input (-) Black Output (-) White Input (+) Red Shielded, 4 conductor cable: Φ5.3±0.2mm, and cable jacket is PVC. Standard cable length: 2.6±0.1m IP65 200/500 C2 2000 Emax/5000 ≤±0.030 ≤±0.024 ≤±0.03 ≤±0.5 2.3±0.2 410±30 351±2 ≥5000(50VDC) 2 -10~ +40 -35~ +65 5~ 12(DC) 18(DC) 120 150 64(2.52) 80(3.15) 25(0.98) 2-M12 15 (0.59) 15 (0.59) Capacity Accuracy Maximum number of verification intervals Minimum load cell verification interval Combined error Creep Temperature effect on sensitivity Temperature effect on zero Output sensitivity Input resistance Output resistance Insulation resistance Zero balance Temperature, compensated Temperature, operating Excitation, recommended Excitation, max Safe overload Ultimate overload Specifications 102 nmax vmin (%FS) (%FS/30min) (%FS/10℃) (%FS/10℃) (mv/v) (Ω) (Ω) (MΩ) (%FS) (℃) (℃) (V) (V) (%FS) (%FS) Outline Dimension mm(inch) 11 UNITED STATES TEL: 800-637-0529 WWW.BRECKNELLSCALES.COM UNITED KINGDOM TEL: + 44 (0) 845 246 6717 WWW.BRECKNELLSCALES.CO.UK
  19. 19. L6B Features · Capacity: 0.3kg~ 3kg · High accuracy · Max. platform size: 200×200mm · 0.3kg~ 3kg. · Aluminum construction with parallel beam. · Silicon adhesive sealed, surface anodized and anti-corrosion. · Integral structure and easy installation. · Suitable for electronic balance and other electronic weighing devices. L6B load cells are available in the capacities Wiring: Output (+) Green Input (-) Black Output (-) White Input (+) Red Shielded, 4 conductor cable, and cable jacket is PVC. Cable length: 0.45±0.05m Cable diameter: 3±0.2mm 7(0.28) 2 Places 5(0.20) 2 Places 33(1.30) 4-M3 Depth 10(0.39) 10(0.39) 17(0.67)17(0.67) 110(4.33) IP65 11 Capacity Accuracy Maximum number of verification intervals Minimum load cell verification interval Combined error Creep Temperature effect on sensitivity Temperature effect on zero Output sensitivity Input resistance Output resistance Insulation resistance Zero balance Temperature, compensated Temperature, operating Excitation, recommended Excitation, max Safe overload Ultimate overload Corner correction C3 ≤±0.030 0.9±0.1 406±6 350±3 ≥5000(50VDC) 2 -10~ +40 -35~ +65 5~ 12(DC) 18(DC) 120 150 2500 Emax/5000 ≤±0.020 ≤±0.021 ≤±0.028 Specifications 0.3/0.6/1.2/3 0.02% /100mmload value nmax vmin Outline Dimension mm(inch) (%FS) (%FS/30min) (%FS/10℃) (%FS/10℃) (mv/v) (Ω) (Ω) (MΩ) (%FS) (℃) (℃) (V) (V) (%FS) (%FS) Underport Depth 15(0.38) 12 CANADA TEL: 416-213-9900 WWW.BRECKNELLSCALES.CA INDIA TEL: +91 129 4159774/75/76 WWW.SALTERINDIA.COM
  20. 20. Outline Dimension mm(inch) L6C Features · Capacity: 3kg~ 50kg · High accuracy · Max. platform size: 450×450mm · Installed screw request M8, 8.8 class, with oiled screw, torque 25Nm. Capacity Accuracy Maximum number of verification intervals Minimum load cell verification interval Combined error Creep Temperature effect on sensitivity Temperature effect on zero Output sensitivity Input resistance Output resistance Insulation resistance Zero balance Temperature, compensated Temperature, operating Excitation, recommended Excitation, max Safe overload Ultimate overload Corner correction C3D ≤±0.030 2500 Emax/5000 ≤±0.020 ≤±0.021 ≤±0.028 Specifications · L6C load cells are available in the capacities 3kg~ 50kg. · Aluminum construction with parallel beam. · Silicon adhesive sealed, surface anodized and anti-corrosion. · Integral structure and easy installation. · Suitable for pricing scale, counting scale, electronic balance and other electronic weighing devices. Wiring: 406±6 350±3 ≥5000(50VDC) 2 -10~ +40 -35~ +65 5~ 12(DC) 18(DC) 120 150 0.02% /100mmload value 3/5/8/20/30/50 Input (+) Shield Output (-) Input (-) Output (+) Shielded, 5 conductor ribbon cable. Cable length: 0.35±0.05m The shield is connected to the element. IP65 2-M8-6H Through 125(4.92) 45(1.77) 29(1.14) 24(0.94) 45(1.77) 27 (1.06) 8 (0.31) 2-M8 Depth 15(0.59) 2 Places Limiting plate 2 nmax vmin (%FS) (%FS/30min) (%FS/10℃) (%FS/10℃) (mv/v) (Ω) (Ω) (MΩ) (%FS) (℃) (℃) (V) (V) (%FS) (%FS) 1.9±0.2 13 UNITED STATES TEL: 800-637-0529 WWW.BRECKNELLSCALES.COM UNITED KINGDOM TEL: + 44 (0) 845 246 6717 WWW.BRECKNELLSCALES.CO.UK
  21. 21. L6D Features · Capacity: 2.5kg~ 50kg · High accuracy · Max. platform size: 250×350mm · OIML Certificates No:R60/2000-CN-00.05 Revision 1 · PTB Approval No:D09-03.20 Revision 1 · NTEP Certificates N0: CC 11-012 Capacity Accuracy Approvals Maximum number of verification intervals Minimum load cell verification interval Combined error Creep Temperature effect on sensitivity Temperature effect on zero Output sensitivity Input resistance Output resistance Insulation resistance Zero balance Temperature, compensated Temperature, operating Excitation, recommended Excitation, max Safe overload Ultimate overload Corner correction C3 OIML R60 C3 3000 Emax/7000 ≤±0.020 ≤±0.0167 ≤±0.0175 ≤±0.020 2.0±0.2 406±6/1065±15 350±3/1000±10 ≥5000(50VDC) 2 -10~ +40 -35~ +65 5~ 12(DC) 18(DC) 120 150 0.02%load value/100mm Specifications · L6D load cells are available in the capacities 2.5kg~ 50kg. · Aluminum construction with parallel beam. · Silicon adhesive sealed, surface anodized and anti-corrosion. · Integral structure and easy installation. · Suitable for pricing scale, platform scale and other electronic weighing devices. 2.5/3/5/6/8/10/15/20/30/35/40/50 Output resistance Input Output + +- - R R W B G G W B1000(Ω) Wiring: Shield Transparent 350(Ω) hielded, 4 conductor cable, and cable jacket is PVC. Cable length: 0.40±0.05m Cable diameter: 3.8±0.2mm S Output (+) Green Input (-) Black Output (-) White Input (+) Red IP65 15(0.59) 25(0.98) 2 Places 301.18() 130(5.21) 22(0.87) 2Places 2 Places 12(0.47) 4-M6-6H Through Outline Dimension mm(inch) nmax vmin (%FS) (%FS/30min) (%FS/10℃) (%FS/10℃) (mv/v) (Ω) (Ω) (MΩ) (%FS) (℃) (℃) (V) (V) (%FS) (%FS) 14 CANADA TEL: 416-213-9900 WWW.BRECKNELLSCALES.CA INDIA TEL: +91 129 4159774/75/76 WWW.SALTERINDIA.COM
  22. 22. Outline Dimension mm(inch) L6D21 Features · Capacity: 3kg~ 50kg · Excellent waterproof ability · High accuracy · Max. platform size: 250×350mm · L6D21 load cells are available in the capacities 3kg~ 50kg. · Aluminum construction with parallel beam. · Special sealing techniques and surface anodized makes waterproof and anti-corrosion. · Integral structure and easy installation. · Suitable for pricing scales, platform scales and other electronic weighing devices which has high requirements for waterproof ability. Wiring: Shielded, 4 conductor cable, and cable jacket is PVC. Cable length: 4m Cable diameter: 3.8±0.2mm Output (+) Green Input (-) Black Output (-) White Input (+) Red Capacity Accuracy Maximum number of verification intervals Minimum load cell verification interval Combined error Creep Temperature effect on sensitivity Temperature effect on zero Output sensitivity Input resistance Output resistance Insulation resistance Zero balance Temperature, compensated Temperature, operating Excitation, recommended Excitation, max Safe overload Ultimate overload Corner correction C3 3000 Emax/7000 ≤±0.020 ≤±0.0167 ≤±0.0175 ≤±0.020 2.0±0.2 409±6 350±3 ≥5000(50VDC) 2 -10~ +40 -35~ +70 5~ 12(DC) 18(DC) 150 300 0.02%load value/100mm Specifications 3/6/10/15/20/30/40/50 IP68 15(0.59) 2Places22 (0.87) 106 (4.17) 30 (1.18) 130 (5.12) 4-M6-6H Through nmax vmin (%FS) (%FS/30min) (%FS/10℃) (%FS/10℃) (mv/v) (Ω) (Ω) (MΩ) (%FS) (℃) (℃) (V) (V) (%FS) (%FS) 15 UNITED STATES TEL: 800-637-0529 WWW.BRECKNELLSCALES.COM UNITED KINGDOM TEL: + 44 (0) 845 246 6717 WWW.BRECKNELLSCALES.CO.UK
  23. 23. 40(1.57) 150(5.91) 33(1.30) 4 Places 35(1.38) 7(0.28) 19(0.75) 8-M8-6H Depth 20(0.79) Through hole 15(0.59) 19(0.75) 19(0.75) 7(0.28) Outline Dimension mm(inch) L6E Features · Capacity: 50kg~ 300kg · High accuracy · Max. platform size: 400×400mm · OIML Certificates No:R60/2000-CN-00.04 Revision 1 · PTB Approval No:D09-03.21 Revision 1 · NTEP Certificates No: CC:11-062 Capacity Accuracy Approvals Maximum number of verification intervals Minimum load cell verification interval Combined error Creep Temperature effect on sensitivity Temperature effect on zero Output sensitivity Input resistance Output resistance Insulation resistance Zero balance Temperature, compensated Temperature, operating Excitation, recommended Excitation, max Safe overload Ultimate overload Corner correction C3 OIML R60 C3 3000 Emax/7000 ≤±0.020 ≤±0.0167 ≤±0.0175 ≤±0.020 2.0±0.2 406±6 350±3 ≥5000(50VDC) 2 -10~ +40 -35~ +65 5~ 12(DC) 18(DC) 120 150 0.02%load value/100mm Specifications · L6E load cells are available in the capacities 50kg~ 300kg. · Aluminum construction with parallel beam. · Silicon adhesive sealed, surface anodized and anti-corrosion. · Integral structure and easy installation. · Suitable for pricing scales, platform scales and other electronic weighing devices. Wiring: hielded, 4 conductor cable, and cable jacket is PVC. Cable length: 2±0.1m Cable diameter: 5.3±0.2mm S Output (+) Green Input (-) Black Output (-) White Input (+) Red IP65 (%FS) (%FS/30min) (%FS/10℃) (%FS/10℃) (mv/v) (Ω) (Ω) (MΩ) (%FS) (℃) (℃) (V) (V) (%FS) (%FS) nmax vmin 8-M8-6H Depth 20(0.79) Depth 24 16 CANADA TEL: 416-213-9900 WWW.BRECKNELLSCALES.CA INDIA TEL: +91 129 4159774/75/76 WWW.SALTERINDIA.COM 50/60/80/100/150/200/300
  24. 24. B6E Outline Dimension mm(inch) Wiring: Shielded, 4 conductor cable:Φ5mm Standard cable length: 2m Output (+) Green Input (-) Black Output (-) White Input (+) Red · B6E load cells are available in the capacities 100kg~ 300kg. · 17-4PH stainless steel construction, potted by adhesive inside, oil proof, waterproof, anti-corrosive gas and medium making it suitable for all kinds of environments. · Single point with parallel beam, suitable for electronic scales, platform scales, belt scales and other electronic weighing devices. · Recommended platform size: 400×400mm Accuracy Maximum number of verification intervals Minimum load cell verification interval Combined error Creep Temperature effect on sensitivity Temperature effect on zero Output sensitivity Input resistance Output resistance Insulation resistance Zero balance Temperature, compensated Temperature, operating Excitation, recommended Excitation, max Safe overload Ultimate overload Corner correction Capacity C3 3000 Emax/10000 ≤±0.020 ≤±0.016 ≤±0.011 ≤±0.015 2.0±0.2/2.0±0.002 384±4/400±20 351±2.0 ≥5000(50VDC) 1.5 -10~ +40 -35~ +70 5~ 12(DC) 18(DC) 150 300 0.02%load value/100mm 100/150/200/300 16.5(0.65) 8-M6-6H 15(0.59)Depth 35 (0.99) 15(0.59) 7(0.28) Two ends 2-3 Two ends Two ends Twoends Two ends 19(0.75) 150(5.91) 40(1.57) 38(1.50) ) 0 3 . 1 ( 3 3 8 (0.31) 38 (1.50) IP66 Specifications 2 (%FS) (%FS/30min) (%FS/10℃) (%FS/10℃) (mv/v) (Ω) (Ω) (MΩ) (%FS) (℃) (℃) (V) (V) (%FS) (%FS) nmax vmin Features · Capacity: 100kg~ 300kg · High accuracy · Stainless steel construction · Low profile and easy installation 17 UNITED STATES TEL: 800-637-0529 WWW.BRECKNELLSCALES.COM UNITED KINGDOM TEL: + 44 (0) 845 246 6717 WWW.BRECKNELLSCALES.CO.UK
  25. 25. Outline Dimension mm(inch) H6E Features · Capacity: 100kg~ 300kg · High accuracy · Alloy · steel construction Low profile and easy installation Wiring: Shielded, 4 conductor cable: Φ5mm Standard cable length: 2m Output (+) Green Input (-) Black Output (-) White Input (+) Red · H6E load cells are available in the capacities 10 ~ · Alloy nickel plated, · · × 0kg 300kg. steel construction, potted by adhesive inside, oil proof, waterproof, anti-corrosive gas and medium making it suitable for all kinds of environments. Single point with parallel beam, suitable for electronic scales, platform scales, belt scales and other electronic weighing devices. Recommended platform size: 400 400mm Accuracy Maximum number of verification intervals Minimum load cell verification interval Combined error Creep Temperature effect on sensitivity Temperature effect on zero Output sensitivity Input resistance Output resistance Insulation resistance Zero balance Temperature, compensated Temperature, operating Excitation, recommended Excitation, max Safe overload Ultimate overload Corner correction Capacity C3 3000 Emax/10000 ≤±0.020 ≤±0.016 ≤±0.011 ≤±0.015 2.0±0.2/2.0±0.002 384±4/400±20 351±2.0 ≥5000(50VDC) 1.5 -10~ +40 -35~ +70 5~ 12(DC) 18(DC) 150 300 0.02%load value/100mm Specifications 100/150/200/300 IP66 16.5(0.65) 8-M6-6H Depth 15(0.59) 35 (0.99) 15(0.59) 7(0.28) Two ends 2-3 Two ends Twoends Two ends 19(0.75) 150(5.91) 40(1.57) 38(1.50) ) 0 3 . 1 ( 3 3 8 (0.31) 38 (1.50) 17 (%FS) (%FS/30min) (%FS/10℃) (%FS/10℃) (mv/v) (Ω) (Ω) (MΩ) (%FS) (℃) (℃) (V) (V) (%FS) (%FS) nmax vmin Two ends 18 CANADA TEL: 416-213-9900 WWW.BRECKNELLSCALES.CA INDIA TEL: +91 129 4159774/75/76 WWW.SALTERINDIA.COM
  26. 26. 40(1.75) 2 Places 33(1.30) 2 Places 6(0.24) 150(5.91) 8-M6-6H Depth 20(0.79) 44(1.73) 30(1.18) 19(0.75) 2 Places 2Places Outline Dimension mm(inch) L6E3 Features · Capacity: 50kg~ 300kg · High accuracy · Max. platform size: 450×450mm · OIML Certificates No:R60/2000-CN1-06.08 · PTB Approval No: D09-06.09 · NTEP Certificates No: CC11-062 Capacity Accuracy Approvals Maximum number of verification intervals Minimum load cell verification interval Combined error Creep Temperature effect on sensitivity Temperature effect on zero Output sensitivity Input resistance Output resistance Insulation resistance Zero balance Temperature, compensated Temperature, operating Excitation, recommended Excitation, max Safe overload Ultimate overload Corner correction 2.0±0.2 406±6 350±3 ≥5000(50VDC) 2 -10~ +40 -35~ +65 5~ 12(DC) 18(DC) 120 150 0.02%load value/100mm Specifications · L6E3 load cells are available in the capacities 50kg~ 300kg. · Aluminum construction with parallel beam. · Silicon adhesive sealed, surface anodized and anti-corrosion. · Integral structure and easy installation. · Suitable for electronic pricing scales, electronic platform scales and other electronic weighing devices. 50/100/150/200/250/300 Wiring: hielded, 4 conductor cable, and cable jacket is PVC. Cable length: 3±0.1m Cable diameter: 5.3±0.2mm S Output (+) Green Input (-) Black Output (-) White Input (+) Red IP65 (%FS) (%FS/30min) (%FS/10℃) (%FS/10℃) (mv/v) (Ω) (Ω) (MΩ) (%FS) (℃) (℃) (V) (V) (%FS) (%FS) C3 OIML R60 C3 3000 Emax/7000 ≤±0.020 ≤±0.0167 ≤±0.0175 ≤±0.020 nmax vmin Underport Depth 24(0.94) 19 UNITED STATES TEL: 800-637-0529 WWW.BRECKNELLSCALES.COM UNITED KINGDOM TEL: + 44 (0) 845 246 6717 WWW.BRECKNELLSCALES.CO.UK Central Carolina Scale, Inc 5393 Farrell Road Sanford NC 27330 PH: 919-776-7737 www.CentralCarolinaScale.com
  27. 27. B6E3 Features · Capacity: 20kg~ 300kg · High accuracy · Stainless steel construction · Low profile and easy installation Outline Dimension mm(inch) Wiring: Shielded, 4 conductor cable: Φ5mm Standard cable length: 3m Output (+) Green Input (-) Black Output (-) White Input (+) Red · B6E3 load cells are available in the capacities ~ · · · Max. × 20kg 300kg. 17-4PH stainless steel construction, potted by adhesive inside, oil proof, waterproof, anti-corrosive gas and medium making it suitable for all kinds of environments. Single point with parallel beam, suitable for electronic scales, platform scales, belt scales and other electronic weighing devices. platform size: 400 400mm Accuracy Maximum number of verification intervals Minimum load cell verification interval Combined error Creep Temperature effect on sensitivity Temperature effect on zero Output sensitivity Input resistance Output resistance Insulation resistance Zero balance Temperature, compensated Temperature, operating Excitation, recommended Excitation, max Safe overload Ultimate overload Corner correction Capacity C3 3000 Emax/10000 ≤±0.020 ≤±0.016 ≤±0.011 ≤±0.015 2.0 0 2/2.0±0.002 384±4 351±2.0 ≥5000(50VDC) 1.5 -10~ +40 -35~ +70 5~ 12(DC) 18(DC) 150 300 0.02%load value/100mm ± . 20/30/50/75/100/150/200/250/300 IP66 40 (1.57) Two ends 8-M8-6H Depth 20 6(0.24) 2-3 Two ends Twoends 19(0.75) Two ends 150(5.91) 15.5 (0.61) Φ12.2 Through 33(1.30) 38 (1.50) 38(1.50) 8(0.31) 44 (1.73) 30(1.18) 19 (%FS) (%FS/30min) (%FS/10℃) (%FS/10℃) (mv/v) (Ω) (Ω) (MΩ) (%FS) (℃) (℃) (V) (V) (%FS) (%FS) nmax vmin Underport Depth27 Specifications 20 CANADA TEL: 416-213-9900 WWW.BRECKNELLSCALES.CA INDIA TEL: +91 129 4159774/75/76 WWW.SALTERINDIA.COM
  28. 28. L W H W1 H1 8-M L6F Features · Capacity: 50kg~ 2000kg · High accuracy · Max. platform size: 50kg~ 200kg 600×600mm 250kg~ 500kg 600×800mm 750kg~ 2000kg 1200×1200mm · OIML Certificates No:R60/2000-CN1-06.01 Revision 1 · PTB Approval No:D09-06.10 Capacity Accuracy Approvals Maximum number of verification intervals Minimum load cell verification interval Combined error Creep Temperature effect on sensitivity Temperature effect on zero Output sensitivity Input resistance Output resistance Insulation resistance Zero balance Temperature, compensated Temperature, operating Excitation, recommended Excitation, max Safe overload Ultimate overload Corner correction C3 OIML R60 C3 3000 Emax/7000 ≤±0.020 ≤±0.0167 ≤±0.0175 ≤±0.020 2.0±0.2 406±6 350±3 ≥5000(50VDC) 2 -10~ +40 -35~ +65 5~ 12(DC) 18(DC) 120 150 0.02%load value/100mm Specifications · L6F load cells are available in the capacities 50kg~ 2000kg. · Aluminum construction with parallel beam. · Silicon adhesive sealed, surface anodized and anti-corrosion. · Integral structure and easy installation. · Suitable for electronic pricing scales, platform scales and other electronic weighing devices. Wiring: hielded, 6 conductor cable, and cable jacket is PVC. Cable length: 3±0.1m Cable diameter: 6.2±0.2mm S 50/100/150/200/250/500/750/1000/2000 Input (+) Red Input (-) Yellow Output (-) White Output (+) Blue Shield Sense (+) Brown Sense (-) Black M12-7H Depth20(0.79) Dimension Capacity 50~200kg,250kgSE 250~500kg,750kgSE 750~2000kg H H1 L W W1 M M16-7H Depth20(0.79) M12-7H Depth18(0.71) 75(2.95) 95(3.74) 125(4.92) 50(1.97) 70(2.76) 85(3.35) 156(6.14) 146(5.75) 176(6.93) 44(1.73) 60(2.36) 76(2.99) 24(0.94) 36(1.42) 46(1.81) IP65 (%FS) (%FS/30min) (%FS/10℃) (%FS/10℃) (mv/v) (Ω) (Ω) (MΩ) (%FS) (℃) (℃) (V) (V) (%FS) (%FS) nmax vmin Outline Dimension mm(inch) UNITED STATES TEL: 800-637-0529 WWW.BRECKNELLSCALES.COM UNITED KINGDOM TEL: + 44 (0) 845 246 6717 WWW.BRECKNELLSCALES.CO.UK 21
  29. 29. 4-R3 2 2 Places 2 4 Places H2 Twoends H H1 Twoends 8-MDepth20 B1 Twoends 3 2Places L1 B L L2 B6F Features · Capacity: 100kg~ 2000kg · High accuracy · Stainless steel construction · Low profile and easy installation · OIML Certificates No:R60/2000-NL1-10.31 Outline Dimension mm(inch) Wiring: Shielded, 4 conductor cable: Φ6.2mm Standard cable length: 3m · B6F load cells are available in the capacities 100kg~ 2000kg. · 17-4PH stainless steel construction, potted by adhesive inside, oil proof, waterproof, anti-corrosive gas and medium making it suitable for all kinds of environments. · Single point with parallel beam, suitable for electronic scales, platform scales, belt scales and other electronic weighing devices. · Max. platform size: 100kg~ 200kg 400×400mm 250kg~ 500kg 600×800mm 750kg~ 2000kg 1200×1200mm Capacity Accuracy Maximum number of verification intervals Minimum load cell verification interval Combined error Creep Temperature effect on sensitivity Temperature effect on zero Output sensitivity Input resistance Output resistance Insulation resistance Zero balance Temperature, compensated Temperature, operating Excitation, recommended Excitation, max Safe overload Ultimate overload Corner correction C3 3000 Emax/10000 ≤±0.020 ≤±0.016 ≤±0.011 ≤±0.015 2.0±0.2/2.0±0.002 384±4/400±20 351±2.0 ≥5000(50VDC) 1.5 -10~ +40 -35~ +70 5~ 12(DC) 18(DC) 150 300 0.02%load value/100mm Specifications 100/150/200/250/500/750/1000/2000 Output (+) Blue Sense (-) Black Output (-) White Input (+) Red Input (-) Yellow Sense (+) Brown Dimension 250kg~500kg 44(1.73) 24(0.94) 75(2.95) 50(1.97) 30(1.18) 156(6.14) 112(4.4) 14(0.55) M12-7H B B1 H H1 H2 L L1 L2 M 60(2.36) 36(1.42) 95(3.74) 70(2.76) 30(1.18) 146(5.75) 110(4.33) 11(0.43) M12-7H 76(2.99) 46(1.81) 125(4.92) 95(3.74) 65(2.56) 176(6.93) 110(4.33) 24(0.94) M16-7H 750kg~2t100kg~200kg Capacity IP66 (%FS) (%FS/30min) (%FS/10℃) (%FS/10℃) (mv/v) (Ω) (Ω) (MΩ) (%FS) (℃) (℃) (V) (V) (%FS) (%FS) nmax vmin 9 2 h t p e D 22 CANADA TEL: 416-213-9900 WWW.BRECKNELLSCALES.CA INDIA TEL: +91 129 4159774/75/76 WWW.SALTERINDIA.COM
  30. 30. H6F Features · Capacity: 100kg~ 2000kg · High accuracy · Alloy steel construction · Low profile and easy installation Outline Dimension mm(inch) Wiring: Shielded, 4 conductor cable: Φ5mm Standard cable length: 3m · H6F load cells are available in the capacities 100kg~ 2000kg. · Alloy steel construction, potted by adhesive inside, oil proof, waterproof, anti-corrosive gas and medium making it suitable for all kinds of environments. · Single point with parallel beam, suitable for electronic scales, platform scales, belt scales and other electronic weighing devices. · Max. platform size: 100kg~ 200kg 400×400mm 250kg~ 500kg 600×800mm 750kg~ 2000kg 1200×1200mm Capacity Accuracy Maximum number of verification intervals Minimum load cell verification interval Combined error Creep Temperature effect on sensitivity Temperature effect on zero Output sensitivity Input resistance Output resistance Insulation resistance Zero balance Temperature, compensated Temperature, operating Excitation, recommended Excitation, max Safe overload Ultimate overload Corner correction C3 3000 Emax/10000 ≤±0.020 ≤±0.016 ≤±0.011 ≤±0.015 2.0±0.2/2.0±0.002 384±4/400±20 351±2.0 ≥5000(50VDC) 1.5 -10~ +40 -35~ +70 5~ 12(DC) 18(DC) 150 300 0.02%load value/100mm Specifications 100/150/200/250/350/500/750/1000/2000 Output (+) Blue Sense (-) Black Output (-) White Input (+) Red Input (-) Yellow Sense (+) Brown Dimension 250kg~500kg 44(1.73) 24(0.94) 75(2.95) 50(1.97) 30(1.18) 156(6.14) 112(4.4) 14(0.55) M12-7H B B1 H H1 H2 L L1 L2 M 60(2.36) 36(1.42) 95(3.74) 70(2.76) 30(1.18) 146(5.75) 110(4.33) 11(0.43) M12-7H 76(2.99) 46(1.81) 125(4.92) 95(3.74) 65(2.56) 176(6.93) 110(4.33) 24(0.94) M16-7H 750kg~2t100kg~200kg Capacity IP66 4-R3 2 2 Places 5 4 Places H2 Twoends H H1 Twoends 8-MDepth20 B1 Twoends 3 2Places L1 B L L2 (%FS) (%FS/30min) (%FS/10℃) (%FS/10℃) (mv/v) (Ω) (Ω) (MΩ) (%FS) (℃) (℃) (V) (V) (%FS) (%FS) nmax vmin 9 2 h t p e D UNITED STATES TEL: 800-637-0529 WWW.BRECKNELLSCALES.COM UNITED KINGDOM TEL: + 44 (0) 845 246 6717 WWW.BRECKNELLSCALES.CO.UK 23
  31. 31. Specifications 8-M8-7H Depth 32(1.26) 4 Places 7(0.28) 4 Places 19(0.75) 65(2.56)60(2.36) 30(1.18) 42(1.69) 174(6.86) 43(1.69) Outline Dimension mm(inch) L6G Features · Capacity: 50kg~ 600kg · High accuracy · Max. platform size: 600×600mm · OIML Certificates No:R60/2000-CN-00.03 · PTB Approval No:D09-03.22 Revision 2 Capacity Accuracy Approvals Maximum number of verification intervals Minimum load cell verification interval Combined error Creep Temperature effect on sensitivity Temperature effect on zero Output sensitivity Input resistance Output resistance Insulation resistance Zero balance Temperature, compensated Temperature, operating Excitation, recommended Excitation, max Safe overload Ultimate overload Corner correction C3 OIML R60 C3 3000 Emax/7000 ≤±0.020 ≤±0.0167 ≤±0.0175 ≤±0.020 2.0±0.2 406±6/1065±15 350±3/1000±10 ≥5000(50VDC) 2 -10~ +40 -35~ +65 5~ 12(DC) 18(DC) 120 150 0.02%load value/100mm · L6G load cells are available in the capacities 50kg~ 600kg. · Aluminum construction with parallel beam. · Silicon adhesive sealed, surface anodized and anti-corrosion. · Integral structure and easy installation. · Suitable for electronic pricing scales, platform scales and other electronic weighing devices. Wiring: hielded, 6 conductor cable, and cable jacket is PVC. Cable length: 3±0.1m Cable diameter: 6±0.2mm The shield is connected to the element. S 50/100/150/200/250/300/500/600 Input (+) Red Input (-) Black Output (-) White Output (+) Green Shield Sense (+) Blue Sense (-) Yellow IP65 (%FS) (%FS/30min) (%FS/10℃) (%FS/10℃) (mv/v) (Ω) (Ω) (MΩ) (%FS) (℃) (℃) (V) (V) (%FS) (%FS) nmax vmin Underport Depth 40(1.57) 24 CANADA TEL: 416-213-9900 WWW.BRECKNELLSCALES.CA INDIA TEL: +91 129 4159774/75/76 WWW.SALTERINDIA.COM
  32. 32. 63(2.48) 65(2.56) 32.5(1.28) 174(6.85) Twoends 30(1.18) 60(2.36) 16.5 (0.65) 43(1.69) Two ends Twoends 8-M8-6H Depth 25(0.98) Two ends 7(0.28) 19(0.75) 2-3 (0.12) B6G Features · Capacity: 100kg~ 600kg · High accuracy · Stainless steel construction · Low profile and easy installation Outline Dimension mm(inch) Wiring: Shielded, 6 conductor cable: Φ6.2mm Standard cable length: 3m · B6G load cells are available in the capacities 100kg~ 600kg. · 17-4PH stainless steel construction, potted by adhesive inside, oil proof, waterproof, anti-corrosive gas and medium making it suitable for all kinds of environments. · Single point with parallel beam, suitable for electronic scales, platform scales, belt scales and other electronic weighing devices. · Recommended platform size: 600×600mm Capacity Accuracy Maximum number of verification intervals Minimum load cell verification interval Combined error Creep Temperature effect on sensitivity Temperature effect on zero Output sensitivity Input resistance Output resistance Insulation resistance Zero balance Temperature, compensated Temperature, operating Excitation, recommended Excitation, max Safe overload Ultimate overload Corner correction C3 3000 Emax/10000 ≤±0.020 ≤±0.016 ≤±0.011 ≤±0.015 2.0±0.002 384±4 351±2.0 ≥5000(50VDC) 1.5 -10~ +40 -35~ +70 5~ 12(DC) 18(DC) 150 300 0.02%load value/100mm Specifications 100/150/200/250/300/500/600 Output (+) Blue Sense (-) Black Output (-) White Input (+) Red Input (-) Yellow Sense (+) Brown IP66 kg (%FS) (%FS/30min) (%FS/10℃) (%FS/10℃) (mv/v) (Ω) (Ω) (MΩ) (%FS) (℃) (℃) (V) (V) (%FS) (%FS) nmax vmin Underport Depth33(1.3) UNITED STATES TEL: 800-637-0529 WWW.BRECKNELLSCALES.COM UNITED KINGDOM TEL: + 44 (0) 845 246 6717 WWW.BRECKNELLSCALES.CO.UK 25
  33. 33. H6G Features · Capacity: 100kg~ 600kg · High accuracy · Alloy steel construction · Low profile and easy installation Outline Dimension mm(inch) Wiring: Shielded, 6 conductor cable: Φ6.2mm Standard cable length: 3m · H6G load cells are available in the capacities 100kg~ 600kg. · Alloy steel construction, potted by adhesive inside, oil proof, waterproof, anti-corrosive gas and medium making it suitable for all kinds of environments. · Single point with parallel beam, suitable for electronic scales, platform scales, belt scales and other electronic weighing devices. · Recommended platform size: 600×600mm Capacity Accuracy Maximum number of verification intervals Minimum load cell verification interval Combined error Creep Temperature effect on sensitivity Temperature effect on zero Output sensitivity Input resistance Output resistance Insulation resistance Zero balance Temperature, compensated Temperature, operating Excitation, recommended Excitation, max Safe overload Ultimate overload Corner correction C3 3000 Emax/10000 ≤±0.020 ≤±0.016 ≤±0.011 ≤±0.015 2.0±0.002 384±4 351±2.0 ≥5000(50VDC) 1.5 -10~ +40 -35~ +70 5~ 12(DC) 18(DC) 150 300 0.02%load value/100mm Specifications 100/150/200/250/300/500/600 Output (+) Blue Sense (-) Black Output (-) White Input (+) Red Input (-) Yellow Sense (+) Brown IP66 632.48() 652.56() 32.5(1.28) 174(6.85) Twoends 30(1.18) 60(2.36) 16.5 (0.65) 43(1.69) Two ends Twoends 8-M8-6H Depth 25(0.98) Two ends 7(0.28) 19(0.75) 2-3 (0.12) kg (%FS) (%FS/30min) (%FS/10℃) (%FS/10℃) (mv/v) (Ω) (Ω) (MΩ) (%FS) (℃) (℃) (V) (V) (%FS) (%FS) nmax vmin Underport Depth33(1.3) 26 CANADA TEL: 416-213-9900 WWW.BRECKNELLSCALES.CA INDIA TEL: +91 129 4159774/75/76 WWW.SALTERINDIA.COM
  34. 34. H6G5 Features · Capacity: 50kg~ 2t · High accuracy · Alloy steel construction · Low profile and easy installation Outline Dimension mm(inch) Wiring: Shielded, 4 conductor cable: Φ6.2mm Standard cable length: 3m · H6G5 load cells are available in the capacities 50kg~ 2000kg. · Alloy steel construction, potted by adhesive inside, oil proof, waterproof, anti-corrosive gas and medium making it suitable for all kinds of environments. · Single point with parallel beam, suitable for electronic scales, platform scales, belt scales and other electronic weighing devices. · Max. platform size: 50kg~ 1t 600×800mm 1.5t~ 2t 1000×1000mm tCapacity Accuracy Maximum number of verification intervals Minimum load cell verification interval Combined error Creep Temperature effect on sensitivity Temperature effect on zero Output sensitivity Input resistance Output resistance Insulation resistance Zero balance Temperature, compensated Temperature, operating Excitation, recommended Excitation, max Safe overload Ultimate overload Corner correction C3 3000 Emax/10000 ≤±0.020 ≤±0.016 ≤±0.011 ≤±0.015 2.0±0.002 384±4 351±2.0 ≥5000(50VDC) 1.5 -10~ +40 -35~ +70 5~ 12(DC) 18(DC) 120 150 0.02%load value/100mm Specifications Output (+) Blue Sense (-) Black Output (-) White Input (+) Red Input (-) Yellow Sense (+) Brown Dimension 1.5t~2t50kg~1t Capacity 50kg/100kg/150kg/200kg/250kg/300kg/500kg/1t/2t L H H1 W W1 68(2.68) 38(1.50) 77(3.03) 46(1.81) 76(2.99) 150(5.91)150(5.91) 88(3.46) 55(2.17) 42(1.65) IP66 16.5(0.65) 8-M14-6H Depth 25 2-3 H H1 Twoends H/2 2-W1 Twoends W L (%FS) (%FS/30min) (%FS/10℃) (%FS/10℃) (mv/v) (Ω) (Ω) (MΩ) (%FS) (℃) (℃) (V) (V) (%FS) (%FS) nmax vmin UNITED STATES TEL: 800-637-0529 WWW.BRECKNELLSCALES.COM UNITED KINGDOM TEL: + 44 (0) 845 246 6717 WWW.BRECKNELLSCALES.CO.UK 27
  35. 35. Outline Dimension mm(inch) L6H5 Features · Capacity: 4kg~ 20kg · High accuracy · Max. platform size: 200×200mm · OIML Certificates No:R60/2000-NL1-10.23 Capacity Accuracy Maximum number of verification intervals Minimum load cell verification interval Combined error Creep Temperature effect on sensitivity Temperature effect on zero Output sensitivity Input resistance Output resistance Insulation resistance Zero balance Temperature, compensated Temperature, operating Excitation, recommended Excitation, max Safe overload Ultimate overload Corner correction kg Specifications 4/5/6/8/10/20 C3D 2500 Emax/5000 ≤±0.030 ≤±0.020 ≤±0.020 ≤±0.020 2.0±0.2 406±6 350±3 ≥5000(50VDC) 2 -10~ +40 -35~ +65 5~ 12(DC) 18(DC) 120 150 0.02%load value/100mm · L6H5 load cells are available in the capacities 4kg~ 20kg. · Aluminum construction with parallel beam. · Silicon adhesive sealed, surface anodized and anti-corrosion. · Integral structure and easy installation. · Suitable for electronic balance and other electronic weighing devices. Wiring: Output (+) Green Input (-) Black Output (-) White Input (+) Red Shielded, 4 conductor cable, and cable jacket is PVC. Cable length: 0.17±0.05m Cable diameter: 3.8±0.2mm 2Places 28(1.18) 50(1.97) 20(0.79) 80(3.15) 4-M8Depth10(0.39) 2Places IP65 (%FS) (%FS/30min) (%FS/10℃) (%FS/10℃) (mv/v) (Ω) (Ω) (MΩ) (%FS) (℃) (℃) (V) (V) (%FS) (%FS) nmax vmin 28 CANADA TEL: 416-213-9900 WWW.BRECKNELLSCALES.CA INDIA TEL: +91 129 4159774/75/76 WWW.SALTERINDIA.COM
  36. 36. Outline Dimension mm(inch) L6J Features · Capacity: 1kg~ 20kg · High accuracy · Max. platform size: 200×200mm Capacity Accuracy Maximum number of verification intervals Minimum load cell verification interval Combined error Creep Temperature effect on sensitivity Temperature effect on zero Output sensitivity Input resistance Output resistance Insulation resistance Zero balance Temperature, compensated Temperature, operating Excitation, recommended Excitation, max Safe overload Ultimate overload Corner correction kg Specifications · L6J load cells are available in the capacities 1kg~ 20kg. · Aluminum construction with parallel beam. · Silicon adhesive sealed, surface anodized and anti-corrosion. · Integral structure and easy installation. · Suitable for electronic balance and other electronic weighing devices. Wiring: Output (+) Green Input (-) Black Output (-) White Input (+) Red Shielded, 4 conductor cable, and cable jacket is PVC. Cable length: 0.45±0.05m Cable diameter: 3.0±0.2mm 32(1.26) 2 Places 32(1.26) 10(0.39) 2 Places 2-M5Depth18(0.71) 79(3.11) 88(3.46) 16(0.63) 2-M5 Depth 18(0.71) IP65 (%FS) (%FS/30min) (%FS/10℃) (%FS/10℃) (mv/v) (Ω) (Ω) (MΩ) (%FS) (℃) (℃) (V) (V) (%FS) (%FS) nmax vmin 1/2/3/5/8/10/15/20 C3D 2500 Emax/5000 ≤±0.030 ≤±0.020 ≤±0.020 ≤±0.020 1.5±0.2 406±6 350±3 ≥5000(50VDC) 2 -10~ +40 -35~ +65 5~ 12(DC) 18(DC) 120 150 0.02%load value/100mm UNITED STATES TEL: 800-637-0529 WWW.BRECKNELLSCALES.COM UNITED KINGDOM TEL: + 44 (0) 845 246 6717 WWW.BRECKNELLSCALES.CO.UK 29
  37. 37. 4-M3 Depth 14(0.55) 70(2.76) 2Places 7(0.28) 12 (0.47) 22 (0.87) 2 Through holes 6 (0.23) Outline Dimension mm(inch) L6J1 Features · Capacity: 0.3kg~3kg · High accuracy · Max. platform size: 200×200mm Capacity Accuracy Maximum number of verification intervals Minimum load cell verification interval Combined error Creep Temperature effect on sensitivity Temperature effect on zero Output sensitivity Input resistance Output resistance Insulation resistance Zero balance Temperature, compensated Temperature, operating Excitation, recommended Excitation, max Safe overload Ultimate overload Corner correction kg Specifications · L6J1 load cells are available in the capacities 0.3kg~3kg. · Aluminum construction with parallel beam. · Silicon adhesive sealed, surface anodized and anti-corrosion. · Integral structure and easy installation. · Suitable for electronic balance and other electronic weighing devices. Wiring: Output (+) Green Input (-) Black Output (-) White Input (+) Red Shielded, 4 conductor cable, and cable jacket is PVC. Cable length: 0.45±0.05m Cable diameter: 3.0±0.2mm IP65 (%FS) (%FS/30min) (%FS/10℃) (%FS/10℃) (mv/v) (Ω) (Ω) (MΩ) (%FS) (℃) (℃) (V) (V) (%FS) (%FS) nmax vmin 0.3/0.4/0.5/0.6/1/3 C3D 2500 Emax/5000 ≤±0.030 ≤±0.020 ≤±0.030 ≤±0.030 1.0±0.1 394±6 350±3 ≥5000(50VDC) 2 -10~+40 -35~+65 5~ 12(DC) 18(DC) 120 150 0.02%load value/100mm 30 CANADA TEL: 416-213-9900 WWW.BRECKNELLSCALES.CA INDIA TEL: +91 129 4159774/75/76 WWW.SALTERINDIA.COM
  38. 38. Outline Dimension mm(inch) L6L Features · Capacity: 5kg~ 200kg · High accuracy · Max. platform size: 350×400mm Capacity Accuracy Maximum number of verification intervals Minimum load cell verification interval Combined error Creep Temperature effect on sensitivity Temperature effect on zero Output sensitivity Input resistance Output resistance Insulation resistance Zero balance Temperature, compensated Temperature, operating Excitation, recommended Excitation, max Safe overload Ultimate overload Corner correction kg · L6L load cells are available in the capacities 5kg~ 200kg. · Aluminum construction with parallel beam. · Silicon adhesive sealed, surface anodized and anti-corrosion. · Integral structure and easy installation. · Suitable for electronic balance and other electronic weighing devices. Wiring: Output (+) Green Input (-) Black Output (-) White Input (+) Red Shielded, 4 conductor cable, and cable jacket is PVC. Cable length: 1.0±0.05m Cable diameter: 5.3±0.2mm IP65 40(1.57) F View 2-M6 Depth 20(0.79)M6-7H Through hole 18(0.71) 6(0.24) 18(0.71) 31(1.22) 2Places 4-M6 Depth 20(0.79) 6(0.24) F View 18(0.71) 18(0.71) 150(5.91) Specifications (%FS) (%FS/30min) (%FS/10℃) (%FS/10℃) (mv/v) (Ω) (Ω) (MΩ) (%FS) (℃) (℃) (V) (V) (%FS) (%FS) nmax vmin 5/8/10/15/20/30/50/80/100/150/200 C3D 2500 Emax/5000 ≤±0.030 ≤±0.020 ≤±0.021 ≤±0.028 2.0±0.2 394±6 350±3 ≥5000(50VDC) 2 -10~ +40 -35~ +65 5~ 12(DC) 18(DC) 120 150 0.02%load value/100mm UNITED STATES TEL: 800-637-0529 WWW.BRECKNELLSCALES.COM UNITED KINGDOM TEL: + 44 (0) 845 246 6717 WWW.BRECKNELLSCALES.CO.UK 31
  39. 39. Capacity Accuracy Approvals Maximum number of verification intervals Minimum load cell verification interval Combined error Creep Temperature effect on sensitivity Temperature effect on zero Output sensitivity Input resistance Output resistance Insulation resistance Zero balance Temperature, compensated Temperature, operating Excitation, recommended Excitation, max Safe overload Ultimate overload Corner correction kg Specifications 3/5/8/10/15/20/30/50/75/100 C3 OIML R60 C3 3000 Emax/7000 ≤±0.020 ≤±0.0167 ≤±0.0175 ≤±0.020 2.0±0.2 406±6 350±3 ≥5000(50VDC) 2 -10~ +40 -35~ +65 5~ 12(DC) 18(DC) 120 150 0.02%load value/100mm Outline Dimension mm(inch) L6N Features · Capacity: 3kg~ 100kg · High accuracy · Max. Platform size: 400×400mm · OIML Certificates No:R60/2000-CN1-06.04 · PTB Approval No:D09-06.11 · NTEP Certificates No: CC11-055 · L6N load cells are available in the capacities 3kg~ 100kg. · Aluminum construction with parallel beam. · Silicon adhesive sealed, surface anodized and anti-corrosion. · Integral structure and easy installation. · Suitable for electronic balance and other electronic weighing devices. Wiring: Output (+) Green Input (-) Black Output (-) White Input (+) Red Shielded, 4 conductor cable, and cable jacket is PVC. Cable length: 3.0±0.05m Cable diameter: 5.0±0.2mm Ip65 7-M Depth 15(0.59) 19(0.75) 2Places 31.24 (1.23) 11.18 (0.44) 40 (1.58) 19 (0.75) 150(5.9) 5.84(0.23) 2Places 25.4 (1.0) 100(3.94) 34 (1.34) (%FS) (%FS/30min) (%FS/10℃) (%FS/10℃) (mv/v) (Ω) (Ω) (MΩ) (%FS) (℃) (℃) (V) (V) (%FS) (%FS) nmax vmin 32 CANADA TEL: 416-213-9900 WWW.BRECKNELLSCALES.CA INDIA TEL: +91 129 4159774/75/76 WWW.SALTERINDIA.COM
  40. 40. B6N Features · Capacity: 15kg~ 200kg · High accuracy · Stainless steel construction · Low profile and easy installation · OIML Certificates No:R60/2000-NL1-11.27 Outline Dimension mm(inch) Wiring: hielded, 4 conductor cable: Φ5mm Standard cable length: 1m S · B6N load cells are available in the capacities 15kg~ 200kg. · 17-4PH stainless steel construction, potted by adhesive inside, oil proof, waterproof, anti-corrosive gas and medium making it suitable for all kinds of environments. · Single point with parallel beam, suitable for electronic scales, platform scales, belt scales and other electronic weighing devices. · Recommended platform size: 400×400mm Capacity Accuracy Maximum number of verification intervals Minimum load cell verification interval Combined error Creep Temperature effect on sensitivity Temperature effect on zero Output sensitivity Input resistance Output resistance Insulation resistance Zero balance Temperature, compensated Temperature, operating Excitation, recommended Excitation, max Safe overload Ultimate overload Corner correction C3 3000 Emax/10000 ≤±0.020 ≤±0.016 ≤±0.011 ≤±0.015 2.0±0.002 384±4 351±2.0 ≥5000(50VDC) 1.5 -10~ +40 -35~ +70 5~ 12(DC) 18(DC) 150 300 0.02%load value/100mm Specifications Output (+) White Sense (-) Yellow Output (-) Red Input (+) Green Input (-) Black Sense (+) Blue 15/20/30/50/75/100/150/200 Note: Machining thread hole M and N are basing on customers' requirements. When customers require imperial: Thread hole M is 1/4-20UNC-2B, Thread hole N is 1/4-28UNF-2B; When customers require metric: Both thread holes M and N are M6-6H, and there will be an "M" under exit hole. · · · IP66 34 Twoends(1.34) 19.05 (0.75) 25 (0.98) 38(1.5) 19.05(0.75) 150(5.91) H1 4-MDepth15(0.59) H 40(1.57) 38(1.496) NDepth15(0.59) 100(3.94) kg (%FS) (%FS/30min) (%FS/10℃) (%FS/10℃) (mv/v) (Ω) (Ω) (MΩ) (%FS) (℃) (℃) (V) (V) (%FS) (%FS) nmax vmin Underport Depth18(0.71) Underport Depth18(0.71) UNITED STATES TEL: 800-637-0529 WWW.BRECKNELLSCALES.COM UNITED KINGDOM TEL: + 44 (0) 845 246 6717 WWW.BRECKNELLSCALES.CO.UK 33
  41. 41. Outline Dimension mm(inch) L6Q Features · Capacity: 50kg~ 250kg · High accuracy · Max. platform size: 400×400mm PTB Approval No: D09-07.06· · NTEP Certificates No: CC11-104 Capacity Accuracy Approvals Maximum number of verification intervals Minimum load cell verification interval Combined error Creep Temperature effect on sensitivity Temperature effect on zero Output sensitivity Input resistance Output resistance Insulation resistance Zero balance Temperature, compensated Temperature, operating Excitation, recommended Excitation, max Safe overload Ultimate overload Corner correction C3 OIML R60 C3 3000 Emax/7000 ≤±0.020 ≤±0.0167 ≤±0.0175 ≤±0.020 2.0±0.2 406±6 350±3 ≥5000(50VDC) 2 10~ +40 -35~ +65 5~ 12(DC) 18(DC) 120 150 0.02%load value/100mm - kg Specifications · L6Q load cells are available in the capacities 50kg~ 250kg. · Aluminum construction with parallel beam. · Silicon adhesive sealed, stainless steel cover, surface anodized and anti-corrosion. · Integral structure and easy installation. · Suitable for electronic pricing scales, platform scales and other electronic weighing devices. Wiring: Shielded, 6 conductor cable, and cable jacket is PVC. Cable length: 3.0±0.05m Cable diameter: 5.0±0.2mm 50/100/150/200/250 Input (+) Red Input (-) Black Output (-) White Output (+) Green Sense (+) Blue Sense (-) Brown M Metric Imperial M6 1/4-20UNC 8-M Depth 13(0.51) 6.35(0.25) 2 Places 25.1(1.0) 2 Places 150(5.91) 25.4(1.0) 44(1.73) 38.1(1.5) 2Places 38.1(1.5) IP66 nmax vmin (%FS) (%FS/30min) (%FS/10℃) (%FS/10℃) (mv/v) (Ω) (Ω) (MΩ) (%FS) (℃) (℃) (V) (V) (%FS) (%FS) Depth15(0.59) 34 CANADA TEL: 416-213-9900 WWW.BRECKNELLSCALES.CA INDIA TEL: +91 129 4159774/75/76 WWW.SALTERINDIA.COM
  42. 42. B6Q Features · Capacity: 200kg and 250kg. · High accuracy · Stainless steel construction · Low profile and easy installation Outline Dimension mm(inch) Wiring: Shielded, 6 conductor cable: Φ5.0mm Standard cable length: 1.5m · B6Q load cells are available in the capacities 200kg and 250kg. · 17-4PH stainless steel construction, potted by adhesive inside, oil proof, waterproof, anti-corrosive gas and medium making it suitable for all kinds of environments. · Single point with parallel beam, suitable for electronic scales, platform scales, belt scales and other electronic weighing devices. · Recommended platform size:400×400mm kgCapacity Accuracy Maximum number of verification intervals Minimum load cell verification interval Combined error Creep Temperature effect on sensitivity Temperature effect on zero Output sensitivity Input resistance Output resistance Insulation resistance Zero balance Temperature, compensated Temperature, operating Excitation, recommended Excitation, max Safe overload Ultimate overload Corner correction C3 3000 Emax/10000 ≤±0.020 ≤±0.016 ≤±0.011 ≤±0.015 2.0±0.2/2.0±0.002 384±4/400±20 351±2.0 ≥5000(50VDC) 1.5 -10~ +40 -35~ +70 5~ 12(DC) 18(DC) 150 300 0.02%load value/100mm Specifications Output (+) White Sense (-) Yellow Output (-) Red Input (+) Green Input (-) Black Sense (+) Blue 200/250 IP66 38.1 Twoends(1.5) 38 (1.5) 9.35 (0.37) 38 (1.5) 39.9 (1.57) 8-1/4-20UNF-2BDepth15(0.59) 38.1(1.5) 6.35 (0.25) 25.4 4Places(1.0) 150(5.91) 8(0.31) 4-25.4(1.0) Twoends 1/4-28UNF-2B Depth10 41.5(1.63) nmax vmin (%FS) (%FS/30min) (%FS/10℃) (%FS/10℃) (mv/v) (Ω) (Ω) (MΩ) (%FS) (℃) (℃) (V) (V) (%FS) (%FS) Underport Depth12 Underport Depth18(0.71) 35 UNITED STATES TEL: 800-637-0529 WWW.BRECKNELLSCALES.COM UNITED KINGDOM TEL: + 44 (0) 845 246 6717 WWW.BRECKNELLSCALES.CO.UK 35
  43. 43. L6T Features · Capacity: 50kg~ 1000kg · High accuracy · Max. platform size: 600×600mm · OIML Certificates No:R60/2000-DE1-10.11 Capacity Accuracy Approvals Maximum number of verification intervals Minimum load cell verification interval Combined error Creep Temperature effect on sensitivity Temperature effect on zero Output sensitivity Input resistance Output resistance Insulation resistance Zero balance Temperature, compensated Temperature, operating Excitation, recommended Excitation, max Safe overload Ultimate overload Corner correction C3 OIML R60 C3 3000 Emax/7000 ≤±0.020 ≤±0.0167 ≤±0.0175 ≤±0.020 2.0±0.2 406±6 350±3 ≥5000(50VDC) 2 -10~ +40 -35~ +65 5~ 12(DC) 18(DC) 120 150 0.02%load value/100mm kg Specifications · L6T load cells are available in the capacities 50kg~ 1000kg. · Aluminum construction with parallel beam. · Silicon adhesive sealed, surface anodized and anti-corrosion. · Integral structure and easy installation. · Suitable for electronic pricing scales, electronic platform scales and other electronic weighing devices. Wiring: Shielded, 6 conductor cable, and cable jacket is PVC. Cable length: 3.0±0.1m Cable diameter: 5.0±0.2mm 50/75/100/150/200/250/300/500/635/1000 Input (+) Red Input (-) Black Output (-) White Output (+) Green Sense (+) Blue Sense (-) Brown M Metric Imperial M8x1.25 5/16-18UNC-2B 76.2(3.0) 39.8 (1.57) 2Places 24.9(0.98)8-D Depth16(0.63) 60.2(2.37) 2Places 2Places 39.8 (1.57) 7.87(0.31) 2Places 191(7.52) 75.44(2.97) IP65 nmax vmin (%FS) (%FS/30min) (%FS/10℃) (%FS/10℃) (mv/v) (Ω) (Ω) (MΩ) (%FS) (℃) (℃) (V) (V) (%FS) (%FS) Outline Dimension mm(inch) 36 CANADA TEL: 416-213-9900 WWW.BRECKNELLSCALES.CA INDIA TEL: +91 129 4159774/75/76 WWW.SALTERINDIA.COM
  44. 44. Outline Dimension mm(inch) L6W Features · Capacity: 50kg~ 635kg · High accuracy · Recommended platform size: 50kg~ 200kg: 600×600mm 250kg~ 635kg:600×800mm · OIML Certificates No:R60/2000-CNI-06.03 · PTB Approval No: D09-06.12 Capacity Accuracy Maximum number of verification intervals Minimum load cell verification interval Combined error Creep Temperature effect on sensitivity Temperature effect on zero Output sensitivity Input resistance Output resistance Insulation resistance Zero balance Temperature, compensated Temperature, operating Excitation, recommended Excitation, max Safe overload Ultimate overload Corner correction C3 3000 Emax/7000 ≤±0.020 ≤±0.0167 ≤±0.0175 ≤±0.020 2.0±0.2 406±6 350±3 ≥5000(50VDC) 2 -10~ +40 -35~ +70 5~ 12(DC) 18(DC) 150 300 0.02%load value/100mm Specifications · L6W load cells are available in the capacities 50kg~ 635kg. · Aluminum construction with parallel beam. · Silicon adhesive sealed, surface anodized and anti-corrosion. · Integral structure and easy installation. · Suitable for electronic balance and other electronic weighing devices. Wiring: Shielded, 4 conductor cable, and cable jacket is PVC. Cable length: 3.0±0.1m Cable diameter: 4.7±0.2mm 50/100/150/200/250/300/500/635 Input (+) Red Input (-) Black Output (-) White Output (+) Green Sense (+) Blue Sense (-) Brown 2Places 55(2.17)2Places 2Places 188(7.40) 5.5(0.22) 35(1.38) 2Places 50(1.97) 2Places 8-M8(0.31)-6M Depth 20(0.79) 63.5(2.51) IP65 62.3(2.45) kg Approvals OIML R60 C3 nmax vmin (%FS) (%FS/30min) (%FS/10℃) (%FS/10℃) (mv/v) (Ω) (Ω) (MΩ) (%FS) (℃) (℃) (V) (V) (%FS) (%FS) 37 UNITED STATES TEL: 800-637-0529 WWW.BRECKNELLSCALES.COM UNITED KINGDOM TEL: + 44 (0) 845 246 6717 WWW.BRECKNELLSCALES.CO.UK 37
  45. 45. BM6A Features · Capacity: 6kg~ 60kg · High accuracy · Stainless steel construction · Low profile and easy installation · OIML Certificate No: R60/2000-NL1-10.32 Outline Dimension mm(inch) Wiring: Cable diameter: Φ5±0.2mm Standard length for 6 conductor cable: 6m · BM6A load cells are available in the capacities 6kg~ 60kg, and 25~ 100lb. · 17-4PH stainless steel construction, potted by adhesive inside, oil proof, waterproof, anti-corrosive gas and medium making it suitable for all kinds of environments. · Single point with parallel beam, suitable for electronic scales, platform scales, belt scales, packaging scales and other electronic weighing devices. · Recommended platform size: 300×300mm Dimension Capacity 6,12,15,30kg 60kg L H W 130(5.12) 130(5.12) 50(1.96) 50(1.96) 18.5(0.73) 23.5(0.92) 6,12,15,30,60kg 50 (1.97) 10-M6 Depth 8(0.32) W 25 (0.98) 42.5(1.67) 19(0.75) L (0.95) 24 19 (0.75) 65(2.56) 157(6.18) 6 (0.24)24 (0.95) Output (+) White Sense (-) Blue Output (-) Red Input (+) Green Input (-) Black Sense (+) Yellow Accuracy Maximum number of verification intervals Minimum load cell verification interval Combined error Creep Temperature effect on sensitivity Temperature effect on zero Output sensitivity Input resistance Output resistance Insulation resistance Zero balance Temperature, compensated Temperature, operating Excitation, recommended Excitation, max Safe overload Ultimate overload Corner correction kgCapacity C3 3000 Emax/10000 ≤±0.020 ≤±0.016 ≤±0.011 ≤±0.015 2.0±0.2/2.0±0.002/3.0±0.2 400±20 351±2.0 ≥5000(50VDC) 1.5 -10~ +40 -35~ +70 5~ 12(DC) 18(DC) 150 300 Specifications Note: output sensitivity of S1 type is 2.0±0.002mv/v; output of imperial model is 3.0±0.2mv/v, 0.02% /100mmload value 6/12/30/60 nmax vmin (%FS) (%FS/30min) (%FS/10℃) (%FS/10℃) (mv/v) (Ω) (Ω) (MΩ) (%FS) (℃) (℃) (V) (V) (%FS) (%FS) 38 CANADA TEL: 416-213-9900 WWW.BRECKNELLSCALES.CA INDIA TEL: +91 129 4159774/75/76 WWW.SALTERINDIA.COM
  46. 46. BM6E Features · Capacity: 3kg~ 300kg · High accuracy · Stainless steel construction · Low profile and easy installation Outline Dimension mm(inch) Wiring: Shielded, 4 conductor cable: Φ5mm Standard cable length: 2m Output (+) Green Input (-) Black Output (-) White Input (+) Red · BM6E load cells are available in the capacities 50kg~ 300kg. · Stainless steel construction, hermetically welded oil proof, waterproof, anti-corrosive gas and medium making it suitable for all kinds of environments. · Single point with parallel beam, suitable for electronic scales, platform scales, belt scales and other electronic weighing devices. · Recommended platform size: 600×600mm Accuracy Maximum number of verification intervals Minimum load cell verification interval Combined error Creep Temperature effect on sensitivity Temperature effect on zero Output sensitivity Input resistance Output resistance Insulation resistance Zero balance Temperature, compensated Temperature, operating Excitation, recommended Excitation, max Safe overload Ultimate overload Corner correction Capacity C3 3000 Emax/10000 ≤±0.020 ≤±0.016 ≤±0.011 ≤±0.015 2.0±0.2/2.0±0.002 350±3.5 351±2.0 ≥5000(50VDC) 1.5 -10~ +40 -35~ +70 5~ 12(DC) 18(DC) 150 300 Specifications 3/50/100/200/300 0.02% /100mmload value 150(5.9) 15 (0.59) 40(1.57) 35(1.38) 8-M6-6H Depth 15(0.59)7(0.28) 2 Places 15(0.59) 2Places 19(0.75) 2 Places kg nmax vmin (%FS) (%FS/30min) (%FS/10℃) (%FS/10℃) (mv/v) (Ω) (Ω) (MΩ) (%FS) (℃) (℃) (V) (V) (%FS) (%FS) Depth 17(0.67) 37 UNITED STATES TEL: 800-637-0529 WWW.BRECKNELLSCALES.COM UNITED KINGDOM TEL: + 44 (0) 845 246 6717 WWW.BRECKNELLSCALES.CO.UK 39
  47. 47. BM6G Features · Capacity: 75kg~ 500kg · High accuracy · Stainless steel construction · Low profile and easy installation · PTB Approval NO:D09-10.06 · OIML Certificates NO:R60/2000-NL1-11.29 · NTEP Certificate No: CC12-017 · BM6G load cells are available in the capacities 75kg~ 500kg. · 17-4PH stainless steel construction, potted by adhesive inside, oil proof, waterproof, anti-corrosive gas and medium making it suitable for all kinds of environments. · Single point with parallel beam, suitable for electronic scales, platform scales, belt scales and other electronic weighing devices. · Safe and anti-explosive product, can be used in atrocious environment and hazardous areas. · Recommended platform size: 800×800mm Outline Dimension mm(inch) Wiring: Shielded, 4 conductor cable:Φ5mm Standard cable length: 3m Output (+) Green Input (-) Black Output (-) White Input (+) Red 43(1.69) 2 Places 62 (2.44) 19(0.75) 2 Places7 (0.28) 18 (0.71) 174(6.85) 45(1.77) 30(1.81) 2Places 8-M8 Depth18(0.71) 62(2.44) 64(2.52) 32(1.26) Capacity Accuracy Maximum number of verification intervals Minimum load cell verification interval Combined error Creep Temperature effect on sensitivity Temperature effect on zero Output sensitivity Input resistance Output resistance Insulation resistance Zero balance Temperature, compensated Temperature, operating Excitation, recommended Excitation, max Safe overload Ultimate overload Corner correction C3 3000 Emax/10000 ≤±0.020 ≤±0.016 ≤±0.011 ≤±0.015 2.0±0.2/2.0±0.002 350±3.5 350±3.5 ≥5000(50VDC) 1.5 -10~ +40 -35~ +70 5~ 12(DC) 18(DC) 150 300 0.02%load value/100mm Specifications 3/75/100/150/200/300/400/500kg nmax vmin (%FS) (%FS/30min) (%FS/10℃) (%FS/10℃) (mv/v) (Ω) (Ω) (MΩ) (%FS) (℃) (℃) (V) (V) (%FS) (%FS) OIML R60 C3Approvals Depth 22(0.87) 40 CANADA TEL: 416-213-9900 WWW.BRECKNELLSCALES.CA INDIA TEL: +91 129 4159774/75/76 WWW.SALTERINDIA.COM
  48. 48. Features · Capacity: 500kg~ 50t · High accuracy · Alloy steel construction · Low profile · OIML Certificate No: R60/2000-NL1-12.14 Accessories · HY-8-101 · HM-8-401 · HM-8-406 · Hm8 load cells are available in the capacities 500kg~ 50t. · Alloy steel, hermetically welded, oil-proof, waterproof and anti-corrosion, suitable for all kinds of environments. · Single shear beam, easy for installation, suitable for electronic truck scales, track scales, hopper scale and other electronic weighing devices. · Safe and anti-explosive product, can be used in atrocious environment and hazardous areas. HM8 Outline Dimension mm(inch) 37 (1.47) 57.9 (2.28) 37 (1.47) 57.9 (2.28) 37 (1.47) 62.9 (2.48) Capacity Dimension 35 (1.38) 48 (1.89) 78.7 (3.1) 60 (2.36) 127.7 (5.03) 35 (1.38) 35 (1.38) 42 (1.65) 57 (2.24) 1-2t 2.5t 3t 5t 5 (0.2) 5 (0.2) 5 (0.2) 8 (0.31) 12 (0.47) 43 (1.69) 43 (1.69) 43 (1.69) 52 (2.05) 67 (2.64) 37 (1.47) 37 (1.47) 15 (0.59) 48 (1.89) 60 (2.36) 37 (1.47) 13 (0.51) 15 (0.59) 21 (0.83) 28 (1.10) 203 (7.99) 203 (7.99) 203 (7.997) 235 (9.25) 279 (10.98) 95 (3.74) 95 (3.74) 95 (3.74) 110 (4.33) 133 (5.24) 22 (0.87) 22 (0.87) 22 (0.87) 22 (0.87) 32 (1.26) 98 (3.86) 98 (3.86) 98 (3.86) 124 (4.88) 140 (5.51) 82.5 (3.25) 115 (4.53) 90 (3.54) 70 (2.76) 12 (0.47) 18 (0.71) 143.5 (5.65) 174 (6.85) 70 (2.76) 70 (2.76) 34 (1.34) 26 (1.02) 70 (2.76) 96 (3.78) 318 (12.52) 374 (14.72) 153 (6.02) 189 (7.44) 38 (1.5) 44.5 (1..75) 159 (6.26) 181 (7.13) 64 (2.52) 64 (2.52) 64 (2.52) 66 (2.6) 82 (3.32) 89 (3.5) 76 (2.99) / / / / / / 51 (2.01) / / / / / / 46 (1.81) Wiring: Shielded, 6 conductor cable:Φ6.2mm Standard cable length: 6m Output (+) Blue Sense (-) Black Output (-) White Input (+) Red Input (-) Yellow Sense (+) Brown 10t,15t 20t,25t 30t H H1 H2 H3 ΦD ΦdW L L1 L2 L3 L4 L5 L6 L H2 H1 L1 H3 2-Φd 30t,50tThrough hole Through hole 0.5t,25t L4 L3 L2 L6 WW H L5 L3 L2L4 ΦD 6-Φd tCapacity Accuracy Maximum number of verification intervals Minimum load cell verification interval Combined error Creep Temperature effect on sensitivity Temperature effect on zero Output sensitivity Input resistance Output resistance Insulation resistance Zero balance Temperature, compensated Temperature, operating Excitation, recommended Excitation, max Safe overload Ultimate overload C3 3000 Emax/10000 ≤±0.020 ≤±0.016 ≤±0.011 ≤±0.015 Specifications 500kg/1/2/2.5/3/5/10/15/20/25/30/50 2.0±0.002 350±3.5 352±3.0 ≥5000(50VDC) 1.5 -10~ +40 -35~ +70 5~ 12(DC) 18(DC) 150 300 nmax vmin (%FS) (%FS/30min) (%FS/10℃) (%FS/10℃) (mv/v) (Ω) (Ω) (MΩ) (%FS) (℃) (℃) (V) (V) (%FS) (%FS) 37 UNITED STATES TEL: 800-637-0529 WWW.BRECKNELLSCALES.COM UNITED KINGDOM TEL: + 44 (0) 845 246 6717 WWW.BRECKNELLSCALES.CO.UK 41

×