Controllogix 5000 Training

11,003 views
10,619 views

Published on

This is a little promo slide show we put together for our new 3 day crash course in ControlLogix 5000.

Published in: Education
2 Comments
11 Likes
Statistics
Notes
No Downloads
Views
Total views
11,003
On SlideShare
0
From Embeds
0
Number of Embeds
4
Actions
Shares
0
Downloads
0
Comments
2
Likes
11
Embeds 0
No embeds

No notes for slide

Controllogix 5000 Training

  1. 1. Business Industrial Network<br />ControILogix 5000 <br />Business Industrial Network BIN95.com<br />
  2. 2. ControlLogix 5000 … 3 day seminar<br />A no-nonsense 3 day crash course approach<br />in learning ControlLogix and RSLogix 5000 software!<br />Business Industrial Network BIN95.com<br />
  3. 3. ControlLogix 5000 … 3 day seminar<br />Similarities between the SLC 500 processors <br />and the ControlLogix 5000 processors…<br />Business Industrial Network BIN95.com<br />
  4. 4. ControlLogix 5000 … 3 day seminar<br />Similarities between the SLC 500 processors <br />and the ControlLogix 5000 processors…<br />Business Industrial Network BIN95.com<br />
  5. 5. File # Type Description<br /> O 0 Output Stores state of output<br /> I 1 Input Stores state of input<br /> S 2 Status Stores controller for troubleshooting & prog.operation<br /> B 3 Bit Stores internal relay logix<br /> T4 Timers Stores the accumulator & preset values plus status bits<br /> C5 Counters Stores the accumulator & preset values plus status bits<br /> R6 Control Stores length, pointer position, and status bits for instructions such as BSL and BSR<br /> N7 Integer Stores numeric values w/ range of -32767 to 32,767<br /> F8 Float. pt Stores # w/range of…<br /> 1.1754944e-38 to 3.40282347e+38<br />The way it use to be…<br />PLC 5 and SLC 500 software used data files to store I/O and other internal values.<br />Could hold only one type of data ! <br />Business Industrial Network BIN95.com<br />
  6. 6. X<br />EASY for using INSTRUCTIONS …<br />but a challenge for grouping different data types together according to function.<br />Data “Scattered” throughout files<br />File # Name Data Type<br />I1 Start Input<br />I1 Stop Input<br />F8 Speed Set Pt. Floating<br />N7 Alarm Code Interger<br />Business Industrial Network BIN95.com<br />
  7. 7. OLD NEW RSLogix5000 TAGS Description <br /> File # Type<br />O 0 Output Automatically creates their own tags like Local:0:I.Data.5<br /> I 1 Input<br /> S 2 Status Uses GSV & SSV to get info like CPU time, Scan time etc.<br /> B 3 Bit Assign the Boolean (Bool)<br /> T4 Timers Assign the Timer data type to the tag.<br /> C5 Counters Assign the Counter data type to the tag.<br /> R6 Control Assign the Control data type to the tag.<br /> N7 Integer Assign the double integer (DINT) data type to the tag. <br /> F8 Float. pt Assigns the REAL Data to the tag.<br />Business Industrial Network BIN95.com<br />
  8. 8. ControlLogix 5000 …Features<br />High Performance Platform suitable for…<br />Sequential<br />Process<br />Drive<br />Motion Control<br />Business Industrial Network BIN95.com<br />
  9. 9. ControlLogix 5000 …Features<br />Wide range of I/O Modules including…<br />Digital<br />Analogs<br />Specialty cards<br />Business Industrial Network BIN95.com<br />
  10. 10. ControlLogix 5000 <br /><ul><li> High Speed backplane for </li></ul> communications.<br /><ul><li> Supports more than</li></ul> ONE processor!<br /><ul><li> Removal and inserting of </li></ul> ANY module under power<br />Advanced Features <br />Includes…<br /><ul><li> Flash upgrade on site for</li></ul> upgrading modules on site <br /><ul><li> Modules are slot independent!
  11. 11. Coordinated Time System</li></ul>Business Industrial Network BIN95.com<br />
  12. 12. Producer – Consumer Network Model<br />ControlNet<br />The Data “producer” puts a connection ID at the front of each message. The message is then multicast and each module screens the connection ID to determine if it needs that data. If it does it becomes the “consumer”.<br />Business Industrial Network BIN95.com<br />
  13. 13. Multi Tasking<br /><ul><li>Allows up to 32 tasks</li></ul> 1 continuous and 31 periodic<br /> or 32 periodic<br /><ul><li>Each task can support up to 32 programs</li></ul>Business Industrial Network BIN95.com<br />
  14. 14. Multi Language<br />Business Industrial Network BIN95.com<br />
  15. 15. Function Block Diagram<br />Business Industrial Network BIN95.com<br />
  16. 16. Sequential Function Chart<br />Business Industrial Network BIN95.com<br />
  17. 17. Ladder Logic<br />Business Industrial Network BIN95.com<br />
  18. 18. Structure Text<br />Business Industrial Network BIN95.com<br />
  19. 19. ControlLogix 5000 … 3 day seminar<br /> Seminar includes an introduction to….<br />Types of processors...<br />Firm Ware awareness<br />and Memory Modules <br />Business Industrial Network BIN95.com<br />
  20. 20. ControlLogix 5000 … 3 day seminar<br />How to configure I/O modules including…<br />Digital Input and Outputs<br />Analog Input and Outputs<br />and how to configure alarms for advance troubleshooting!<br />Business Industrial Network BIN95.com<br />
  21. 21. ControlLogix 5000 … 3 day seminar<br /> also …<br /><ul><li> In depth TAG structures
  22. 22. Introduction to Arrays
  23. 23. Using the GSV command with arrays
  24. 24. Safety in using FORCES
  25. 25. GSV command and FORCES
  26. 26. Working with UDTs
  27. 27. Advanced troubleshooting tips
  28. 28. Commissioning a processor
  29. 29. Course Challenge </li></ul>Business Industrial Network BIN95.com<br />
  30. 30. ControlLogix 5000 … 3 day seminar<br />The MOST reliable way!<br />Business Industrial Network BIN95.com<br />
  31. 31. Business Industrial Network<br />ControILogix 5000 <br />Business Industrial Network BIN95.com<br />

×