• Share
  • Email
  • Embed
  • Like
  • Save
  • Private Content
Scenes from a Jurisdictional Boiler Inspection
 

Scenes from a Jurisdictional Boiler Inspection

on

  • 1,145 views

 

Statistics

Views

Total Views
1,145
Views on SlideShare
1,140
Embed Views
5

Actions

Likes
0
Downloads
10
Comments
0

1 Embed 5

https://twitter.com 5

Accessibility

Upload Details

Uploaded via as Microsoft PowerPoint

Usage Rights

© All Rights Reserved

Report content

Flagged as inappropriate Flag as inappropriate
Flag as inappropriate

Select your reason for flagging this presentation as inappropriate.

Cancel
  • Full Name Full Name Comment goes here.
    Are you sure you want to
    Your message goes here
    Processing…
Post Comment
Edit your comment

    Scenes from a Jurisdictional Boiler Inspection Scenes from a Jurisdictional Boiler Inspection Presentation Transcript

    • Scenes from a Jurisdictional Boiler Inspection Manufacturing Facility, Ontario June 2013
    • The Boiler Inspection and Insurance Company of Canada  Quite simply, it’s the law.  Business owners are responsible for the periodic inspection of certain boilers and other pressure vessels in order to ensure safety.  Failure to do so can result in heavy penalties and may even lead to a shutdown of operations. Why is a Jurisdictional Inspection necessary? 7/15/2013 2© 2013 The Hartford Steam Boiler Inspection and Insurance Company. All rights reserved.
    • The Boiler Inspection and Insurance Company of Canada  We wait until the boiler is closed for the season before doing an internal inspection. When is a Jurisdictional Inspection usually done? 7/15/2013 3© 2013 The Boiler Inspection and Insurance Company of Canada. All rights reserved.
    • The Boiler Inspection and Insurance Company of Canada  HSB BI&I inspector reviewing confined space entry permit with the attendant and entry supervisor. Jurisdictional Boiler Inspection 7/15/2013 4© 2013 The Boiler Inspection and Insurance Company of Canada. All rights reserved.
    • The Boiler Inspection and Insurance Company of Canada  HSB BI&I inspector checking furnace opening of a 200,000 lb/hr water tube boiler prior to entering the fireside space. Jurisdictional Boiler Inspection 7/15/2013 5© 2013 The Boiler Inspection and Insurance Company of Canada. All rights reserved.
    • The Boiler Inspection and Insurance Company of Canada  A de-commissioned coal-fired boiler.  View of stokers and openings above the traveling grate. Jurisdictional Boiler Inspection 7/15/2013 6© 2013 The Boiler Inspection and Insurance Company of Canada. All rights reserved.
    • The Boiler Inspection and Insurance Company of Canada  Inspection of boiler burner area prior to entering the furnace. Jurisdictional Boiler Inspection 7/15/2013 7© 2013 The Boiler Inspection and Insurance Company of Canada. All rights reserved.
    • The Boiler Inspection and Insurance Company of Canada  HSB BI&I inspector coming out of the furnace area of a field erected water tube boiler. Jurisdictional Boiler Inspection 7/15/2013 8© 2013 The Boiler Inspection and Insurance Company of Canada. All rights reserved.
    • The Boiler Inspection and Insurance Company of Canada  HSB BI&I inspector checking the stamping information on the tag of a safety valve for a water tube steam boiler. Jurisdictional Boiler Inspection 7/15/2013 9© 2013 The Boiler Inspection and Insurance Company of Canada. All rights reserved.
    • The Boiler Inspection and Insurance Company of Canada  HSB BI&I inspector checking a set of safety valves mounted on the steam drum of a water tube boiler. Jurisdictional Boiler Inspection 7/15/2013 10© 2013 The Boiler Inspection and Insurance Company of Canada. All rights reserved.
    • The Boiler Inspection and Insurance Company of Canada  The safety attendant checking the atmospheric conditions of the steam drum with a calibrated instrument prior to the inspection.  He checks the oxygen content, levels of flammable gases and toxicity. Jurisdictional Boiler Inspection 7/15/2013 11© 2013 The Boiler Inspection and Insurance Company of Canada. All rights reserved.
    • The Boiler Inspection and Insurance Company of Canada  HSB BI&I inspector checking the condition of boiler tubes and tube sheet in the steam drum of a water tube boiler. Jurisdictional Boiler Inspection 7/15/2013 12© 2013 The Boiler Inspection and Insurance Company of Canada. All rights reserved.
    • The Boiler Inspection and Insurance Company of Canada  HSB BI&I inspector in the steam drum of a 200,000 lb/hr water tube boiler. Jurisdictional Boiler Inspection 7/15/2013 13© 2013 The Boiler Inspection and Insurance Company of Canada. All rights reserved.
    • The Boiler Inspection and Insurance Company of Canada  HSB BI&I inspector checking the steam separation equipment in the steam drum of a 1952 water tube boiler. Jurisdictional Boiler Inspection 7/15/2013 14© 2013 The Boiler Inspection and Insurance Company of Canada. All rights reserved.
    • Got an expired certificate, or Need an inspection? Call us at 1.855.BOILERØ (1855.264.5370) Or visit www.biico.com/inspect