• Like
  • Save
Biến tần LS iG5 - Tài liệu biến tần LS iG5 (English manual, P.1)
Upcoming SlideShare
Loading in...5
×

Biến tần LS iG5 - Tài liệu biến tần LS iG5 (English manual, P.1)

  • 1,490 views
Uploaded on

Xem chi tiết và đặt mua sản phẩm tại http://hungphu.com.vn/vn/bien-tan-3-pha-220v/bien-tan-3-phase-220v-ig5a-series.html …

Xem chi tiết và đặt mua sản phẩm tại http://hungphu.com.vn/vn/bien-tan-3-pha-220v/bien-tan-3-phase-220v-ig5a-series.html
Biến tần LS iG5 - Tài liệu biến tần LS iG5 (English manual, P.1). Biến tần LS iG5 hiện đang được cung cấp và phân phối tại công ty Hưng Phú Automation.

More in: Education
  • Full Name Full Name Comment goes here.
    Are you sure you want to
    Your message goes here
    Be the first to comment
No Downloads

Views

Total Views
1,490
On Slideshare
0
From Embeds
0
Number of Embeds
5

Actions

Shares
Downloads
0
Comments
0
Likes
1

Embeds 0

No embeds

Report content

Flagged as inappropriate Flag as inappropriate
Flag as inappropriate

Select your reason for flagging this presentation as inappropriate.

Cancel
    No notes for slide

Transcript

  • 1. 0.37 - 4.0kW (0.5 - 5.4HP) 1 and 3 phase 200 - 230Volts,3 phase 380 - 460VoltsLG Variable Frequency Drive(VFD) : Inverterower in MotionStarvert iG5
  • 2. ContentsOverviewFeatures & Selection GuideSpecifications & WiringTerminal Configuration, Keypad & Parameter NavigationProgram Parameter DescriptionsDimensionDB Resistor, Options & Peripheral Devices02040608101214
  • 3. kW / Voltage Ratings:0.5 ~ 2HP, 200-230VAC, 1phase0.5 ~ 5HP, 200-230VAC, 3phase0.5 ~ 5HP, 380-460VAC, 3phaseEnclosure: IP00 ~ IP20Inverter Type: PWM with IGBTControl Method: Volts / Hertz with Space Vector TechnologyBuilt-in RS-485Built-in ModBus-RTUBuilt-in PID controlRemovable keypad (Able to read & write parameter)150% torque at 0.5HzTrip-free operation algorithm8 preset speeds3 jump(skip) frequencies3 Multifuctional inputs1 Multifuctional outputAnalog output (0~12V)PNP and NPN dual directional signalsSpeed search3 wire operation1 to 10 kHz carrier frequencyBuilt-in Braking transistorManual/Auto torque boostStandard featuresCable for Remote Keypad Operations(2,3 and 5 meters)DIN rail base for easy installationCompact iG5,is the best for a small and costeffective configuration.OptionsApplicationConformity to global standardsConvertingFanPumpFood processing machineElectric shutterDryerRunning machineOverheatCommercial washing machineGrinderTextile machineMaterial handling machineCentrifugeElevator doorTooling machineUL and cUL listed for North AmericaCE marked for EuropeQuality process controlled by ISO9001, ISO14000Overview02
  • 4. Reduced sizeEnhancing its performance the iG5 shows much smaller sizecompares to the previous model, the iG series.Maximum 50% of total volume has been reduced in iG5 in order tomount it easily on smaller control panel and DIN rail with less weight.It allows more cost effective panel construction and system design.Built-in PID controlIt is valuable in process control. The built-in PID controller controls flow, temperature, pressure, etc.through the proportional, integral and differential calculus between the feedback value and referencevalue in closed loop.Built-in communication interface and PC monitoring softwareThe iG5 has built-in the most popular communication interfaces such as Modbus-RTU and RS232/485.The iG5 has the small inverter features and standard medium drive features together.The "DriveviewTM" software offers Window® based computer monitoring tool through RS485 interface withgraphic capture, keypad emulator, parameter edit and text monitor. It is applicable for all LG inverters.ModBus-RTUTMRS - 485Space vector PWM technologyThe Space vector technology is being adopted in all LG drives. It features outstanding performance in itscontrol characteristics. It has low total harmonic distortion, low current ripple, low torque ripple, low motortemperature rise, and better voltage utilization. It is a basic control platform of the iG5 drive. The advantages ofSpace vector PWM technology are being proved in many applications.Better Efficiency (Low Iron Loss in Motor)Low Motor Heat (Extended Motor)HighVoltage Utilization (15.9%)Stable & Smooth OperationHigh and StableTorqueLow TotalHarmonic DistortionLow Torque Ripple Low Current RippleStarvert iG503
  • 5. Optimum acceleration and decelerationTo achieve a maximum torque during the acceleration and deceleration, "trip free" function is activated.The 32-bit DSP CPU monitors the current transition during the acceleration and deceleration to program anoptimum curve that is under the trip-triggering level.StoppedCH1=2VDC 10:1CH3=5VDC 10:1CH4=2VDC 10:11s/div[1s/div]NORM:1kS/s=Trigger=Mode : AUTOType : EDGE CH1Delay : 0.0nsHold Off : MINIMUM=Record Length=Main : 10kZoom : 500=Filter=Smoothing : OFFBW : FULL=Offset=Ch1 : 0.00VCh2 : 0.00VCH3 : 0.00VCH4 : 0.00V=Trigger=Mode : AUTOType : EDGE CH1Delay : 0.0nsHold Off : MINIMUM=Record Length=Main : 10kZoom : 500=Filter=Smoothing : OFFBW : FULL=Offset=Ch1 : 0.00VCh2 : 0.00VCH3 : 0.00VCH4 : 0.00V3StoppedCH1=2VDC 10:1CH3=5VDC 10:1CH4=2VDC 10:11s/div[1s/div]NORM:1kS/s3Traditional curve Optimum curveTripPNP and NPN switchable duals signalsThe iG5 has both PNP and NPN signals in order to controlled by PLC or outside controller.Regardless the type of PLC or type of control signal, iG5 can work with positive 24Vdc and negative 24Vdc.Inverter rating selection guideInverter type nomenclatureLG Starvert drive004008015.2200.37kW0.75kW1.5kW.22kWiG5iS5iHiV5iG5 seriesiS5 seriesiH series*iV5 series1 phase 200~230V3 phase 200~230V3 phase 380~460V-1-2-4SV 008 iG5 -4Features & Selection Guide* iH drive has a different designation in kW.04
  • 6. Starvert iG5V/F controlDigital reference : 0.01 Hz (below 100 Hz), 0.1 Hz (over 100 Hz) Analog reference : 0.03 Hz / 50 HzDigital : 0.01% of max. output frequency Analog : 0.1% of max. output frequencyLinear, Square pattern, User V/F150 % of rated current for 1 min., 200% of rated current for 0.5 sec. (characteristic is inversely proportional to time)Manual torque boost (0 ~ 15 %), Auto torque boostKeypad / terminal / communication operationAnalog : 0 ~ 10V / 4 ~ 20 mA Digital : keypadForward, ReverseUp to 8 speeds can be set (use multi-function terminal)0 ~ 6,000 sec, up to 8 types can be set and selected for each setting (use the multi- function terminal),Accel/Decel pattern : linear pattern, U pattern, S pattern, Optimum, MinimumInterrupts the output of the driveJog operationResets fault when protective function is activeFrequency level detection, Overload alarm, stalling, overvoltage, undervoltage, drive overheating, running, stop,constant speed, speed searchingContact output (30A,30C,30B) - AC250V 1A, DC30V 1AChoose 1 from output frequency, output current, output voltage, DC voltage (Output pulse: 500Hz, Output voltage: 0 ~ 10V)DC braking, frequency limit, frequency jump, second function, slip compensation, reverse rotation prevention,auto restart, PID controlOvervoltage, undervoltage, overcurrent, drive overheating, motor over heating, input/output phase loss,input/output mis-wiring, overload protection, communication error, loss of speed command, hardware fault.Stall prevention, overload alarmLess than 15 msec : continuous operation, more than 15 msec : auto restart possibleOutput frequency, output current, output voltage, frequency value setting, operating speed, DC voltageIndicates the fault when the protection function activates, memorizes up to 5 faults-10 °C ~ 40 °C-20 °C ~ 65 °C90 % RH max.(Non condensing)Below 1,000 m ˙ below 5.9m/sec2(=0.6g)No corrosive gas, combustible gas, oil mist, or dustControl methodFrequency setting resolutionFrequency accuracyV/F ratioOverload capacityTorque boostOperation methodFrequency settingStart signalMulti-stepMulti-step accel/decel timeEmergency stopJogFault resetOperation statusFault outputIndicatorDrive tripInverter alarmMomentary power lossOperation informationTrip informationAmbient temperatureStorage temperatureAmbient humidityAltitude . VibrationApplication siteControlOperationOperationfunctionProtectivefunctionInputsignalOutputsignalDisplayKeypadEnvironment*1)Indicatesthemaximumapplicablecapacitywhenusing4poleLGstandardmotor.*2)Ratedcapacity( 3*V*I)isbasedon220Vfor200Vclassand440Vfor 400Vclass.*3)Maximumoutputvoltagewillnotbegreaterthantheinputvoltage.Outputvoltagelessthantheinputvoltagecanbeset.05Specifications 200 ~230V Class(0.5~ 5.4 HP)Specifications 380 ~460V Class(0.5~ 5.4 HP)50 ~ 60 Hz ( 5%)Weight[kg]Drive Type (SV_ _ _iG5-_) 004-4Motor Rating*1) [HP][kW]Output ratingsInput ratingsCapacity[kVA]*2)Braking torqueCooling method Forced air coolingAverage braking torque 20% (with optional external braking resistor : 100%, 150%)Max. continuous braking time 15 secondsMax. duty 0 ~ 30 % EDEnclosure IP00Weight [kg]FLA[A]0.50.371.11.1008-410.751.92.5015-421.534022-432.24.56037-453.76.18040-45.446.591.7 1.7 1.8 2.1 2.2 2.2Frequency 0 ~ 400 HzFrequencyBraking circuit On boardVoltage 380 ~ 460V*3)Voltage 3 phase 380 ~ 460 V( 10%)3 phase 200 ~ 230 V( 10%)50 ~ 60 Hz ( 5%)50 ~ 60 Hz ( 5%)Drive Type (SV_ _ _iG5-_) 004-1Motor Rating*1) [HP][kW]Output ratingsInput ratingsWeight[kg]Capacity[kVA]*2)Braking torqueCooling method Forced air cooling Forced air coolingNaturalAverage braking torque 20% (with optional external braking resistor : 100%, 150%)Max. continuous braking time 15 secondsMax. duty 0 ~ 30 % EDEnclosure IP00FLA[A]0.50.371.13008-110.751.95015-121.538004-20.50.371.13008-210.751.95015-221.538022-232.24.512037-253.76.116040-25.446.5171.2 1.8 2.1 1.2 1.2 1.8 2.1 2.2 2.2Frequency 0 ~ 400 HzFrequencyBraking circuit On boardVoltage 200 ~ 230V*3)Voltage 1 phase 200 ~ 230 V( 10%)
  • 7. WiringNote) " " display main circuit terminals, " " display control circuit terminals.1. Analog speed command can be set by Voltage, Current and both of them.2. DB resistor is optional.DB Resistor*2MOTORUB2B1VWRMCCB1ø 230V3ø230/460V50/60HzSTGFX24RXBXRSTJOGP1P2P3CMVRACBS+S-MOFMCMMGV1ICMorForward Run/StopReverse Run/StopDrive gate blockFault ResetJogMulti-function Input 1Multi-function Input 2Multi-function Input 3Common TerminalPotentiometer(1kohm, 1/2W)ShieldFactory Setting`Speed-L``Speed-M``Speed-H`Power supply forspeed signal:+12V, 100mAOutput Frequency Meter(0 ~ 12V : pulse output)Fault output relayIess than AC250V, 1AIess than DC30V, 1AMulti-function outputIess than DC24V, 50mAFactory setting:`RUN`ModBus-RTURS-485Speed signal input:0 ~10VSpeed signal input:4 ~ 20mA(250ohm)Common forVR, V1, ISpeed signal Input*1+Specifications &WiringCommunication portFM06
  • 8. Power terminal configurationSymbolRSTUVWB1B2GAC Line input (1 phase 200~230 Vac for "-1" units 3 phase, 200~230 Vac for "-2" units and 380~460 Vac for "-4" units)3 phase output terminals to motorExternal additional dynamic braking resistor connection terminals.Chassis ground (The gound terminal("G") may be located on heat sink instead of terminal strip depend on the model name)FunctionParameter group Group nameDrive GroupFunction 1 GroupFunction 2 GroupInput / Output GroupBasic parameters of Command frequency, Accel/Decel time etc.Basic parameters of Max. Frequency, Torque boost etc.Application parameters of Frequency jump, Frequency limit etc.Multifunction terminal setting and Sequence operation parametersDescriptionControl terminal configurationTypeMulti function input 1,2,3Forward run commandReverse run commandJog frequency referenceDrive gate blockFault resetSequence commonFrequency setting power(+12V)Frequency reference (Voltage)Frequency reference(Current)Frequency setting common terminalAnalog/digital output(For external monitoring)Fault contact outputMulti-function output(Open collector output)Communication portUsed for multi function input. Factory default is set to step frequency 1, 2, 3.Forward run when closed and stop when opened.Reverse run when closed and stop when opened.Runs at jog frequency when the jog signal is on. The direction is set by the FX (or RX) signal.When the BX signal is ON, the output of the drive is cut off. When the motor uses an mechanical brake to stop,BX is used to cut off the output signal. When the BX signal, which does not cut off by latching, is OFF and theFX signal (or the RX signal) is ON, the motor keeps running, so be cautious.Used to release the protective status when the protective circuit is active.Used for the common terminal for contact input terminals.Used as power for the analog frequency setting. Maximum output is +12V, 100mA.Used for frequency reference and uses 0-10V for input. Input resistance is 20 kUsed for frequency reference and uses DC 4-20mA for input. Input resistance is 250Common terminal for the analog frequency reference signal and the FM (for monitoring).Outputs one of the followings: output frequency, output current, output voltage, DC link voltage.Factory default is set to output frequency. Maximum output voltage and output current is 0-12V, 1mA.Output frequency is set to 500Hz.Activates when the protective function is operating. AC250V 1A or less, DC30V 1A or lessFault : 30A-30C short (30B-30C open)Nomal : 30A-30C short (30B-30C open)Used for multi-function outputCommunication ports for RS-485Symbol Name DescriptonP1, P2, P3FXRXJOGBXRSTCMVRV1ICMFM.CM30A, 30C, 30BMO.MGS+, S-InputsignalOutputsignalStarting ContactFunction SlectionAnalog FrequencySettingContactPulseRS232KeypadStarvert iG5Class Display NameFUNCUPDOWNRUNSTOP/RESETREVFWDSETRUNProgram keyUp keyDown keyRun keySTOP/RESET keyReverse runForward runSettingOperatingPress to change the parameter setting.Press to move through codes or to increase the parameter values.Press to move through codes or to decrease the parameter values.Use to operate the drivePress to stop during operation. Press to reset when a fault has occurred.During reverse run.During forward run.When the user is setting the parameters using the FUNC keyWhen in constant speed and blinks when accelerating or decelerating.DescriptionKEYLED07