  • 1. Protective device Bhagawan Prasad Chartered Engineer amieclub@gmail.com
  • 2. TYPE OF PROTECTIVE DEVICE  FUSE LOW VOLTAGE  FUSE HIGH VOLTAGE  MCB  ELCB  MCCB  RCCB  SFU  BREAKRS  RTD  THERMOCOUP LE  THEWRMOSTA TE
  • 3. HT FUSE RATING 11/0.415KV KVA PRIMARY SECONDR Y MIN. FUSE MAX. FUSE 50 2.9 72 6 10 75 4.3 108 10 16 100 5.8 144 16 25 125 7.2 180 16 40 160 9.2 231 16 40 200 11.5 290 25 40 250 14.4 360 32 40 315 18.2 455 40 63 400 23 576 40 63
  • 4. RTD  MADE OF PLATINUM , NICKEL, COPPER  TEMP- 600 DEGREE
  • 5. THERMO COUPLE-TEMPERATURE SENSOR  MADE –NICKEL, PLATINUM , COPPER  RATING –UPTO 3000 DEG.
  • 6. BMR  RATING –a) with CT b) without CT
  • 7. THERMOSTAT  RATING-5A
  • 8. Relay  Thermal over load relay  Over current relay  Under voltage relay  Frequency relay  Earth fault relay  Buchholz relay  Master trip  Auxiliary relay  OTI
  • 9. MOTOR PROTECTION UPTO 55KW  SHORT CIRCUIT PROTECTION BY FUSE  SINGLE PHASING PROTECTION  THERMAL OVER LOAD  WINDING TEMPERATURE PROTECTION
  • 10. MOTOR PROTECTION 55-200 KW  SHORT CIRCUIT PROTECTION BY FUSE  SINGLE PHASING PROTECTION  THERMAL OVER LOAD  WINDING TEMPERATURE PROTECTION  STALLED ROTOR
  • 11. PROTECTION OF HT MOTOR  SHORT CIRCUIT PROTECTION BY FUSE/BREAKER  SINGLE PHASING PROTECTION  THERMAL OVER LOAD  WINDING TEMPERATURE PROTECTION  STALLED ROTOR  UNDER VOLTAGE  BEARINGOVER TEMPERATURE  DIFFERENTIAL PROTECTION  PHASE REVERSAL
  • 12. Transformer rating  25,40,63,100  150,250,300,  400,500,630,750,  1000,1250,1600,  2000,2500  150,250,300,  400,500,630,750 ,  1000,1250,1600,  2000,2500 Distribution Power
  • 13. PROTECTION OF DISTRIBUTION TRANSFORMER  Over current protection  Earth fault protection  Buchholz relay  OTI  WTI  Low oil level
  • 14. PROTECTION OF POWER TRANSFORMER  Over current protection  Earth fault protection  Buchholz relay  OTI  WTI  Low oil level  Differential protection  Over fluxing
  • 15. CABLE PROTECTION O/C +E/F (CDG31) Feeder differential
  • 16. Busbars  Differential protection (CAG34)
  • 17. Outgoing feeders from 11KV SWBD  Differential (HORM-4)  O/C +E/F (CDAG 51)
  • 18. RESSTRICTED EARTH FAULT RELAY
  • 19. BIMETALIC =BMR
  • 20. BUCHHOLZ RELAY
  • 21. MASTER TRIP