SURVEYING INSTRUMENTS                      Series30R                              Reflectorless Total Stations        350m...
Series30R                               Innovative Technology Makes Reflectorless                               EDM More P...
■ Ultra-narrow visible laser for pinpoint accuracy                                                                        ...
Series30R                   A Durable Partner That Gives Heavy-Duty                   Support for Daily Surveying Needs  ■...
■ SF14 wireless keyboard (Option*)                                                                       ■ Guide Light Uni...
Series30R                           Packed with Versatile Functions for High                           Work Efficiency at ...
■ Set-out LineThe Set-out line program is used for setting out and checkingalignment of curb lines, construction boards an...
Series30R REFLECTORLESS TOTAL STATIONS                                                                                    ...
Upcoming SlideShare
Loading in …5
×

Especificaciones sokkia 530 r

1,913 views
1,817 views

Published on

0 Comments
0 Likes
Statistics
Notes
  • Be the first to comment

  • Be the first to like this

No Downloads
Views
Total views
1,913
On SlideShare
0
From Embeds
0
Number of Embeds
0
Actions
Shares
0
Downloads
22
Comments
0
Likes
0
Embeds 0
No embeds

No notes for slide

Especificaciones sokkia 530 r

  1. 1. SURVEYING INSTRUMENTS Series30R Reflectorless Total Stations 350m • 1,140ft. Reflectorless Range*Cutting-Edge Technologies Packed in a Compact Body * Class 3R models Laser beam image is simulated.
  2. 2. Series30R Innovative Technology Makes Reflectorless EDM More Powerful Than Ever ■ New advances with RED-tech EDM Sokkia’s revolutionary digital signal processing technology, RED-tech, relies on a unique procedure for measurement beam analysis. Using an A/D converter, it simultaneously samples measuring signals in three different frequencies. Furthermore, RED-tech uses advanced software to calculate distances. As a result, RED-tech ensures that the calculation method most suited to the condition of the measuring beam is selected. It also is able to deliver greater accuracy, speed, and range. And now, RED-tech has been further enhanced through the inclusion of improved optical and electronic components. Its new light emitting and receiving optics provide the ideal light path for capturing light with minimal loss. And its new highly tunable optical filter, which captures multiple samples of beams carrying the correct measurement information, gives you greater precision with difficult-to-measure objects. Thanks to these new components and its advanced technology, RED-tech EDM paves the way to unprecedented distance measurement possibilities. Sampling image ■ Ultra-wide reflectorless measurement range From extra-long distances to remarkably short ones, the Series30R offers accurate reflectorless measurement over a tremendous range of distances. The Series30R total stations feature a Class 3R laser, and cover a range from 0.3m to 350m (1ft. to 1,140ft.). Models equipped with a Class 2 laser are also available. These have a reach of up to 150m (490ft.) or 100m (320ft.). Distances based on use of the white side of a KODAK Gray Card. ■ Reflectorless measurement ■ Sokkia’s traditional optics range and accuracy with a Kodak Gray Card Sokkia’s traditional optics have never been more refined. Light is projected from the middle of an SET230R3 • SET330R3 • SET530R3 objective lens and received along its periphery. Class 3R laser products When combined with a narrow measuring beam, this White side ±(3 + 2ppm x D)mm design enables pinpoint measurement and is highly 90% reflective effective even with narrow objects. Furthermore, the Gray side 200m (650ft.) 350m (1,140ft.) ±(3 + 2ppm x D)mm new telescope provides an extremely bright and 18% reflective ±(5 + 10ppm x D)mm sharp sight. 0.3m (1ft.) 100m (320ft.) 170m (550ft.) ±(5 + 5ppm x D)mm SET230R • SET330R • SET530R Class 2 laser products White side ±(3 + 2ppm x D)mm 90% reflective ±(5 + 10ppm x D)mm 100m (320ft.) 150m (490ft.) Gray side 18% reflective ±(5 + 5ppm x D)mm 0.3m (1ft.) 45m (140ft.) 80m (260ft.) ±(3 + 2ppm x D)mm Receiver SET630R Class 2 laser product White side ±(3 + 2ppm x D)mm 90% reflective Transmitter 100m (320ft.) Optics diagram Gray side 18% reflective ±(5 + 5ppm x D)mm 0.3m (1ft.) 30m (98ft.) 50m (160ft.) ±(3 + 2ppm x D)mm
  3. 3. ■ Ultra-narrow visible laser for pinpoint accuracy A A Series30R: The ultra-narrow laser beam enables accurate measurements through obstacles such as chain-link fences, tree branches, etc. Broader beam models: Both the fence and wall get measured, which leads to erroneous measurement. B C Series30R: Measurements at small incident angles, such as with A manholes on the C road surface, are handled with high B B precision by the Series30R: ultra-narrow laser The measuring beam is measuring beam. extremely narrow, so Broader beam models: distances to walls and Wider measuring beams end corners can be measured up covering a larger area with pinpoint accuracy. than expected at small incident angles, resulting in Broader beam models: A wide measurements that are too measuring beam hits points near C long or short. and far at the same time, resulting in inaccurate measurement.The Series30R employs an ultra small-diameter visible laser to obtain measurements with pinpointaccuracy. Fine objects, as well as the corners of walls and other structures, can be measured precisely.You can also make accurate measurements through obstacles such as chain-link fences and treebranches.■ Laser-pointer functionThe visible laser beam can be used as a convenient laser pointer for interior leveling work, verticalalignment, setting out, and other tasks.■ Long-distance measurement with reflectorsMeasure long distances by directing the laser beam at a reflector. When using a singleAP prism, you can measure as far as 5,000m (16,400ft.)* at once, with an accuracy of±(2 + 2ppm x D)mm. In addition, reflective sheet targets may be used to getmeasurements of up to 500m (1,640ft.)** with ±(3 + 2ppm x D)mm precision. Choosefrom Sokkia’s wide selection of sheet targets to suit your needs. Rotating pin-poletargets, two-point target for measuring hidden points, and many other innovativereflective targets are available.* In good weather conditions except SET630R. ** When using RS90N-K. In the reflective sheet or prism modes, maximum laser output is automatically reduced to 0.22mW. This is equivalent to the level of a Class 1 laser. The Series30R also includes a safety filter in the telescope, which protects your eye from the laser beam if you happen to sight a reflective prism or sheet target while in reflectorless mode.
  4. 4. Series30R A Durable Partner That Gives Heavy-Duty Support for Daily Surveying Needs ■ Sokkias original absolute encoder ■ Status check at a glance The built-in control panel has an easy-to-view LCD screen with 192 x 80 pixel resolution. Key information, such as EDM mode (reflectorless, prism, or reflective sheet target) and laser beam status, can be checked at a glance. LED CCD Absolute encoder disk Encoder diagram The Series30R models are equipped with Sokkia-developed absolute encoders. These encoders feature the RAB (RAndom Bi-directional) code technology first used in the SDL30 digital level, which provides high stability and reliability. You do not need to reset for 0 indexing at the start of a job, so surveying can begin from the moment you turn on the power. Work efficiency is also boosted by the immediate Reflectorless mode display of azimuth whenever you restart the total station. ■ Triple-axis compensation for high reliability Vertical and horizontal angles are compensated for by a dual-axis Reflective sheet Prism mode compensator that detects the tilt of the total station in two directions. target mode In addition, a collimation function corrects the deviation of the telescopes mechanical axis. Working together, these features offer maximum reliability with angle measurements. ■ One-touch target selection ■ Password function for security There are no complicated operations when it comes to selecting The Series30R includes a password-protection function for security targets. The Series30R total stations let you switch between purposes. You can assign your own password to the instrument to reflectorless, prism, and reflective sheet target just by pressing the prevent unauthorized use. SFT key in sequence. The selected target is displayed on the operation panel for easy confirmation. ■ Large internal memory ■ User-friendly keyboard and softkeys The Series30R can store approximately 10,000 data points, including The control panel also includes large, ergonomic buttons as well as known points and other information. To facilitate concurrent use at four softkeys (F1-F4). Softkey functions are structured into 3 pages different work sites, data may be sorted into 10 different job files. and 12 modes, and you are free to assign functions to any key you like. Productivity is enhanced through this balance of functionality and ease of use. ■ CompactFlash card unit (Factory option*) ■ Exceptional durability A card unit for commercially available CompactFlash memory cards can be Featuring advanced protection against water and dust, the added as a factory option. 72,000 points Series30R total stations are ideal for use in inclement weather, (eighteen 4,000-point files) can be stored humid environments, or at dusty work sites. (IP66 compliant) with an 8MB memory card, while a 16MB memory card provides 144,000 points of data storage (thirty-six 4,000-point files). * Not available for SET630R
  5. 5. ■ SF14 wireless keyboard (Option*) ■ Guide Light Unit GDL1 (Factory option)This wireless keyboard has a total of 37 keys (includingalphanumeric keys, softkeys, and measurement controls), to enable quick and easy data entry of point names and coordinate values. Protection against dust and water is another advantage, as you can use the keyboard without worry in the rain or The Guide Light Unit GDL1 boosts efficiency of setting-out at a dusty measurements. Its guide light is composed of two lights of different construction site. colors that are emitted from one aperture. When you are on the left (IP44 compliant) side, the green light is visible, and when you are on the right side, the red light can be seen. When green and red are flashing back and * Not available for SET630R forth, you are on the telescope sighting direction.■ FOF sensors*Sokkias original and extremely compact FOF (Fiber made of OpticalFilter material) sensors are mounted on twosides of the instrument for communication with The light may be used up to a range of A special flashing pattern is also includedthe SF14 wireless keyboard. These sensors 150m (490ft.). to assist users with color weakness.are extremely resistant to light interference,and have a wide signal reception range to Guide Light Unit GDL1 Green LED (524nm) and Red LED (630nm) (Class 1 LED)allow comfortable use of the keyboard. Visible range 1.3m to 150m (4.3ft. to 490ft.) Visible width Horizontal & vertical: more than ±4˚; approx. 7m at 100m (23ft. at 320ft.)* Not included on SET630R Center resolution Within 4; approx. 12cm at 100m (4.7in. at 320ft.) FOF sensor The Guide Light Unit cannot be used simultaneously with the laser pointer function.■ Compact lithium-ion battery Take 6 hours of continuous angle and distance measurements with the Series30Rs rechargeable lithium-ion battery. Unlike Ni-Cd cells, the Series30Rs battery can be fully recharged at any time, without diminishing its energy capacity. The BDC46A battery is commonly used for Sokkias Series10 total stations, digital levels, and other equipment. 3R 2/II * ** **** Factory option for all models ** Option for all models except SET630R *** Factory option for all models except SET630R
  6. 6. Series30R Packed with Versatile Functions for High Work Efficiency at Diverse Sites ■ Missing Line Measurement (MLM) ■ Offset/Distance At the touch of a key, the Series30R measures horizontal The Series30R calculates distance, slope distance, height difference and percentage of the angles and distance, slope between two points. or the coordinates of the Measuring measuring point by Point inputting the distance and direction between the ■ Remote Elevation Measurement (REM) measuring point and the offset point. The Series30R easily determines the height of a point where distance cannot be measured directly. Sight a point either directly above or directly below the target point, and then sight the target point. ■ Offset/Angle The Series30R automatically calculates the position of measuring points. First, ■ 3-D Coordinate Measurement Measuring measure a point on either Point The Series30R calculates side of the measuring 3-D coordinate values of point at the same measuring points and Offset Point distance from the displays them either as N, Series30R instrument. E, Z or E, N, Z. Then sight the measuring Z N point. E ■ Two-Distance Offset With the use of a 2RT500-K two-point target, the Series30R ■ Automatic Azimuth Angle Setting can measure hidden points easily and efficiently. Set the Known Station The Series30R can two-point target on the measuring point (the target does not automatically set the have to be perpendicular), measure targets A and B, and horizontal angle to the input the length between Azimuth Angle azimuth of a back sight by target B and the Z N using the coordinates of measuring point. The the instrument station and Series30R calculates the E A the back sight point. position of the measuring Instrument Station (known) B point in angles and distance, or in coordinate values. ■ Resection ■ Setting Out The Series30R can determine the azimuth and coordinates of The Series30R performs an unknown instrument station with 2 to 10 known points. three-dimensional setting When using two points, measure both angles and distances. out with N, E and Z or E, When using three or more points, the distance is not required. N and Z coordinates. Station elevation from known reference points (up to 10 Directions and distances points) can also be Z N to the setting out position calculated and each Known Station Known Station are indicated on the deviation of multiple E screen. Azimuth Angle reference points is N Z displayed. If a bad point is selected it can be E recalculated, re-observed Instrument Station or replaced with a new (unknown) point.
  7. 7. ■ Set-out LineThe Set-out line program is used for setting out and checkingalignment of curb lines, construction boards and grades of Laser beam image is simulated.pipes. A baseline or an offset from baseline can be defined.When calculating the measuring point, its possible tocalculate and use the scaled down coefficient of the distanceand surveyed value that was calculated using the knowncoordinate values of 2 points.■ Point ProjectionThis program projects a point onto a line. It calculates thedistance and offset of the point relative to the specifiedbaseline, and it computes the coordinates of the intersectionpoint, which can then be directly set out. Elevations areinterpolated where possible.When calculating the measuring point, its possible tocalculate and use the scaled down coefficient of the distance Standard accessoriesand surveyed value that was calculated using the knowncoordinate values of 2 points. BDC46A rechargeable battery: 2 pcs. (SET630R: 1 pc.) ● CDC61/62/64 quick charger ● CP7 tubular FROM POINT TO POINT MEASURED POINT compass ● Lens hood ● Lens cap ● Plumb bob ● Tool OFFSET kit ● Wiping cloth ● Operators manual ● Carrying case and shoulder strap FROM POINT TO POINT Optional accessories SF14 wireless keyboard* ● GDL1 guide light unit (factorySet-out Line and Point Projection option) ● CF card unit* (factory option) ● BDC12 Ni-Cd large external battery*, EDC3 power cable for BDC12 (2m)*, EDC7 power cable for BDC12 (0.5m)*, CDC14 battery charger for BDC12* ● EDC2A AC power adapter (100 to 240V)* ● EDC14 external battery adapter*, EDC5■ Area Calculation car battery cable for EDC14*, EDC4 car cigarette lighter The Series30R can use cable for EDC14* ● OF3A solar filter ● DE25 diagonal measured points or eyepiece ● EL6 eyepiece for SET630R (30x) ● DOC46 stored data to calculate printer cable ● DOC25 (25 pins, male), DOC26 (25 pins, an area. female), DOC 27 (9 pins, female), DOC1 (w/o connector) interface cables ● SC189 back pack * Except SET630R For more information, please consult your local dealer.
  8. 8. Series30R REFLECTORLESS TOTAL STATIONS SPECIFICATIONSSET230R3 ·SET330R3 ·SET530R3 ·SET230R ·SET330R ·SET530R ·SET630R Model SET230R3 SET330R3 SET530R3 SET230R SET330R SET530R SET630R Laser class*1 Class 3R Laser Product Class 2 Laser Product Telescope Fully transiting, coaxial sighting and distance measuring optics Magnification 30x 26x Resolving power 2.5" 3.5" Others Length: 171mm (6.7in.), Objective aperture: 45mm (1.8in.) (EDM 48mm (1.9in.)), Image: Erect, Field of view: 1˚30 (26m/1,000m), Minimum focus: 1.3m (4.3ft.), Reticle illumination: 5 brightness levels. Angle measurement Photoelectrical absolute encoder scanning. Both circles adopt diametrical detection. Unit Degree / Gon / Mil, selectable Display resolutions 1" / 5", 0.2 / 1mgon, 0.005 / 0.02mil, selectable Accuracy (ISO12857-2:1997) 2" / 0.6mg / 0.01mil 3" / 1mg / 0.015mil 5" / 1.5mg / 0.025mil 2" / 0.6mg / 0.01mil 3" / 1mg / 0.015mil 5" / 1.5mg / 0.025mil 6" / 1.9mg / 0.03mil Measuring time 0.5s or less, continuous Measurement mode H: Clockwise / Counterclockwise, selectable. 0 set, Hold, Angle input, Repetition, available. V: Zenith 0 / Horizontal 0 / Horizontal 0± / Slope in %, selectable Automatic dual-axis compensator Dual-axis liquid tilt sensor, Working range: ±3 (±55mg) Collimation compensation On / Off, selectable Fine motion screws 2-speed motion 1-speed motion 2-speed motion 1-speed motion Distance measurement Modulated laser, phase comparison method with red laser diode, coaxial optics Laser output Reflectorless mode: Class 3R equivalent (max. 5mW) Reflectorless mode: Class 2 equivalent (max. 0.99mW) Prism/Sheet mode: Class 1 equivalent (max. 0.22mW) Prism/Sheet mode: Class 1 equivalent (max. 0.22mW) Unit meters / feet / feet-inches, selectable Measuring range Reflectorless* 2 0.3 to 350m (1 to 1,140ft.) (White side, 90% reflective) 0.3 to 150m (1 to 490ft.) (White side, 90% reflective) 0.3 to 100m (320ft.) (slope distance) (with Kodak Gray Card) 0.3 to 170m (1 to 550ft.) (Gray side, 18% reflective) 0.3 to 80m (1 to 260ft.) (Gray side, 18% reflective) (white side, 90% reflective) With reflective sheet target RS90N-K: 1.3 to 500m (1,640ft.), RS50N-K: 1.3 to 300m (980ft.), RS10N-K: 1.3 to 100m (320ft.) With mini prisms CP01: 1.3 to 800m (2,620ft.), OR1PA: 1.3 to 500m (1,640ft.) With 1 AP prism A* 4 1.3 to 4,000m (13,120ft.), 1.3 to 3,000m (9,840ft.) G* 5 1.3 to 5,000m (16,400ft.) 1.3 to 4,000m (13,120ft.) With 3 AP prisms A* 4 to 5,000m (16,400ft.) to 4,000m (13,120ft.) G* 5 to 6,000m (19,680ft.) to 5,000m (16,400ft.) Display resolutions Fine, Rapid single: 0.001m / 0.01ft. / 1/8in. Tracking: 0.01m / 0.1ft. / 1/2in. Accuracy Reflectorless* 2/*3 0.3 to 200m (1 to 650ft.): ±(3 + 2ppm x D)mm 0.3 to 100m (1 to 320ft.): ±(3 + 2ppm x D)mm ±(3 + 2ppm x D)mm (D=measuring (Fine mode) Over 200 to 350m (over 650 to 1,140ft.): ±(5 + 10ppm x D)mm Over 100 to 150m (over 320 to 490ft.): ±(5 + 10ppm x D)mm distance, unit: mm) Reflectorless*2/*3 0.3 to 200m (1 to 650ft.): ±(6 + 2ppm x D)mm 0.3 to 100m (1 to 320ft.): ±(6 + 2ppm x D)mm ±(6 + 2ppm x D)mm (Rapid single mode) Over 200 to 350m (over 650 to 1,140ft.): ±(8 + 10ppm x D)mm Over 100 to 150m (over 320 to 490ft.): ±(8 + 10ppm x D)mm With reflective sheet target Fine: ±(3 + 2ppm x D)mm, Rapid single: ±(6 + 2ppm x D)mm With AP prism Fine: ±(2 + 2ppm x D)mm, Rapid single: ±(5 + 2ppm x D)mm Measuring time Fine mode Repeat: Every 1.3s (initial 2.6s) Rapid single / Tracking Rapid single: 1.8s / Tracking: Every 0.3s (initial1.6s) Measuring mode Fine (single / repeat / average), Rapid (single), Tracking Atmospheric correction / Prism constant correction Temperature / Pressure / ppm input, available. / -99 to +99mm (1mm steps). 0 fixed in reflectorless mode. Refraction & earth-curvature correction ON (K=0.142 / 0.20) / OFF, selectable Data storage and transfer Data storage Internal memory Approx. 10,000 points CF memory card unit Factory option. The 8MB CF card stores approx. 72,000-point data. — Scale factor setting 0.5 to 2.0 Interface Asynchronous serial RS-232C compatible, Baud rate 1,200 to 38,400bps Printer output Centronics compatible (with optional DOC46 printer cable) General Display / Keyboard Alphanumeric/graphic dot matrix LCD, 192 x 80 dots, with backlight, with contrast adjustment / 4 soft keys and 11 keys Control panel location On both faces On one face Wireless keyboard SF14 Optional — Laser-pointer function ON (auto off in 5 minutes) / OFF, selectable. (Does not work simultaneously with the Guide Light.) Guide light GDL1 Factory option Sensitivity of levels Plate level 20" / 2mm 30" / 2mm 20" / 2mm 30" / 2mm 40" / 2mm Circular / Graphic Circular level: 10 / 2mm / Graphic LCD level: 3 / outer circle Optical plummet / Tribrach Image: Erect, Magnification: 3x, Minimum focus: 0.3m (0.98ft.) / Detachable Dust and water protection / Operating temperature Conforms to IP66 (IEC 60529:1989) / -20 to +50˚C (-4 to +122˚F) Instrument height / Size with handle and battery 236mm (9.3in.) from tribrach bottom / W 165 x D 171 x H 341 mm (W 6.5 x D 6.7 x H 13.5 in.) Weight with handle and battery Approx. 5.4kg (12 lb.) Approx. 5.3kg (11.6 lb.) Power supply 7.2V DC BDC46A detachable Li-Ion rechargeable battery 2 BDC46A are included. 1 BDC46A is included. Continuous use (at 25˚C (77˚F)) Approx. 5.5 hours (650 points) for single measurement every 30s Approx. 6 hours (700 points) for single measurement every 30s Approx. 8.5 hours for angle measurement only Recharging time (at 25˚C (77˚F)) Within 2 hours with CDC61/62/64 standard quick chargers. BDC12 external Ni-Cd battery (optional) Approx. 22 hours for single measurement every 30s Approx. 22.5 hours for single measurement every 30s — continuous use (at 25˚C (77˚F)) Approx. 29 hours for angle measurement only Approx. 30 hours for angle measurement only Automatic power cut-off Auto-off time is selectable from 30, 15, 10, 5 minutes or none. Resume function On / Off selectable (backed up for approx. 1 week).*1 IEC 60825-1Amd.2: 2001 / FDA CDRH 21 CFR Part1040.10 and 1040.11 (Complies with FDA performance standards for laser products except for deviations pursuant to Laser Notice No.50, dated July 26,2001.)*2 Reflectorless range/accuracy may be varied according to measuring objects, observation situations and environmental conditions.*3 With Kodak Gray Card White Side (90% reflective)*4 Average conditions: Slight haze, visibility about 20km (12 miles), sunny periods, weak scintillation.*5 Good conditions: No haze, visibility about 40km (25 miles), overcast, no scintillation. 5 3R Sokkia is a sponsor of theKODAK is a registered trademark of the Eastman KODAK Company.Sokkia is a trademark of Sokkia Co., Ltd. Product names mentioned in this brochure are trademarks of their respective owners. International FederationDesigns and specifications are subject to change without notice. Product colors in this brochure may vary slightly from those of the actual products owing to limitations of the printing process. of SurveyorsISO9001 Certified (JQA-0557)http://www.sokkia.co.jp/english/INTERNATIONAL SALES DEPARTMENT260-63 HASE, ATSUGI, KANAGAWA, 243-0036 JAPANPHONE +81-46-248-7984 FAX +81-46-247-1731A-182-E-6-0406-CH-AB Printed in Japan on 100% recycled paper with ecologically safe soy ink.© 2004 SOKKIA CO., LTD.

×