    Inorbit Inorbit Presentation Transcript

    • SUBMITTED BY:Azizur khanT.Y.B.ARCH
    • Introduction... Inorbit mall is located in mumbai,malad Inorbit is at a prime location between Goregaon and Malad, and the emerging business district of Link Road. Inorbit mall is two storey building with a retail area of about 3.64 lakh sq.ft.
    • Ground Floor Plan
    • First Floor Plan…
    • Second Floor Plan…
    • Fire exit Plan…
    • Features …Columns are covered withaluminum panels while Huge skylight.some are decorated withcolorful lights andgraffiti.
    • Features … Spacious food court.Sky light is provided above the foodcourt.
    • Features … Anti skid marble flooring.Two capsule lifts at the center of the mall.
    • Features…Escalators are provided on both sideof the capsule lift and back staircase isprovided behind escalators.
    • Features…• Huge parking space is provided for vehicles .• Electricity station is provided near the parking area.
    • Services…• This is area which is provided behind theoutlets and food court services.• Two lifts are provided in the services area for carrying ,loading etc. purposes.
    • Services… Fire Exit Communication Centre Bag Parking Basement Parking AC Duct Water Supply Pipes Gas Supply Pipes Chimney Parking Area
    • Internal View…  Square shaped false ceiling is done. Internal corridor The corridor is 4.5 m wide. Vitrified tile is used for flooring.
    • Internal View…  Seatings are provided around the columns
    • Views…
    • Escalator… Escalators are provided for continuous mass transport of people. Escalators are generally at an angle of . The escalator is more economicalas it takes less surface area if viewed in plan. According to the worldwide standards the width of the steps should be 0.60 m for single person, 1 m for 2 persons.
    • Escalator…