E. coli by Method EPA 1603   Modified m-TEC
Upcoming SlideShare
Loading in...5
×
 

Like this? Share it with your network

Share

E. coli by Method EPA 1603 Modified m-TEC

on

  • 3,608 views

See a quick demonstration of the membrane filtration technique using prepared media plates with modified m-TEC media.

See a quick demonstration of the membrane filtration technique using prepared media plates with modified m-TEC media.

Statistics

Views

Total Views
3,608
Views on SlideShare
3,598
Embed Views
10

Actions

Likes
1
Downloads
33
Comments
0

2 Embeds 10

http://www.slideshare.net 8
http://www.slideee.com 2

Accessibility

Categories

Upload Details

Uploaded via as Microsoft PowerPoint

Usage Rights

© All Rights Reserved

Report content

Flagged as inappropriate Flag as inappropriate
Flag as inappropriate

Select your reason for flagging this presentation as inappropriate.

Cancel
  • Full Name Full Name Comment goes here.
    Are you sure you want to
    Your message goes here
    Processing…
Post Comment
Edit your comment

E. coli by Method EPA 1603 Modified m-TEC Presentation Transcript

  • 1. Created For Wastewater laboratories and facilities. Membrane Filtration and enumeration of E. Coli using Modified m-TEC methodology. By: Scott J. Bradley
  • 2. Laboratory technician placing the filter on the Manifold Base
    • Sterile Membrane Filter being placed on Magnetic Filter Funnel Base.
    • The filters are made of cellulose ester compounds and are specially designed to trap and hold bacteria during the filtration procedure.
    • The pore size of this filter is 0.45 microns in diameter. Clean, clear water with little sediment filters quickly, but dirty or turbid water can be difficult to filter through.
    • Membrane Filter for E. coli
  • 3. Polysulfone Filter Funnel on Filter Manifold.
    • The filter funnel to the right is used to pour the water sample through the filter. It sits atop the manifold base which is magnetic and prevents any of the sample from escaping during filtration by holding the filter funnel securely to the base.
    • The stopcock below is turned to allow a vacuum to be applied to the filter thereby facilitating and speeding up the filtration process.
    • Filter funnels are sterilized using an autoclave before filtration to prevent cross contamination.
  • 4. Filter Placement
    • Placing the membrane filter onto the petri dish containing the modified m-TEC media. Be sure to flame the tweezers with alcohol before handling filters.
    • Place filter on media plate by starting one corner and “rolling” the rest of the filter down so it lies in contact with the media.
  • 5. Incubation of E. coli with Modified m-TEC
    • Incubate prepared media plates at 35 degrees C. for two hours to resuscitate any stressed microorganisms.
    • Then incubate at
    • 44.5 C. For 22+/- 2h.
    • Then just count the E. coli colonies!
  • 6. Modified m-TEC Plates with E. coli
    • The plate to the right shows a Modified m-TEC media plate with E. coli colonies shown in bright red-magenta color.
    • Modified m-TEC represents an improvement in technique because it combines a single step procedure with a chromogen that makes the red-magenta E. coli colonies easy to read and identify.
    • Photo Courtesy: Aquaplates and Modified m-TEC.com
  • 7. E. Coli with Method EPA 1603: Modified m-TEC
    • This has been a presentation of E. coli by membrane filtration using Modified m-TEC in a prepared media plate.
    • Presented as a courtesy by Scott J. Bradley at Aquacheck Laboratory, Inc.
    • 1-800-263-9596
    • www.Aquacheck-VT.com Aquacheck Laboratory, Inc.