• Share
  • Email
  • Embed
  • Like
  • Save
  • Private Content
Collection of In-Stack NO2/NOx Ratio Information
 

Collection of In-Stack NO2/NOx Ratio Information

on

  • 1,755 views

 

Statistics

Views

Total Views
1,755
Views on SlideShare
1,710
Embed Views
45

Actions

Likes
0
Downloads
5
Comments
0

2 Embeds 45

http://www.all4inc.com 44
http://all4inc.newfangled.com 1

Accessibility

Categories

Upload Details

Uploaded via as Microsoft PowerPoint

Usage Rights

© All Rights Reserved

Report content

Flagged as inappropriate Flag as inappropriate
Flag as inappropriate

Select your reason for flagging this presentation as inappropriate.

Cancel
  • Full Name Full Name Comment goes here.
    Are you sure you want to
    Your message goes here
    Processing…
Post Comment
Edit your comment
  • Needs to non evasive to the current system.Simple approach to collect information.Ran for enough time to get statistical representative dataset.
  • NO and NOX stored in memory. The Difference between the concentrations is used to calculate NO2.
  • Don’t want to use default or published ratios.

Collection of In-Stack NO2/NOx Ratio Information Collection of In-Stack NO2/NOx Ratio Information Presentation Transcript

  • Collection of In-stackNO2/NOX Ratio Information March 14, 2012 Dan Dix Technical Leader ddix@all4inc.com (610) 933-5246, extension 18
  • Introduction  The collection of in-stack NO2/NOX data for use in AERMOD’s OLM and PVMRM option has become more important since the promulgation of the new 1-hour NO2 NAAQS.  Many facilities are currently collecting NOX data using CEMS  CEMS collecting NOX data use the Chemiluminescence method which also measures NO and NO2.2
  • Agenda  Project Overview  Current Setup  Equipment  Conclusions and Additional Considerations  Questions?3
  • Project  Conducting exploratory 1-hour NO2 and SO2 NAAQS air quality modeling for a cement facility.  NO2 NAAQS results showed issues when using Tier III method with OLM and default in-stack NO2/NOX ratio (0.5).  Determine site specific in-stack NO2/NOX ratio data using existing NOX monitor.4
  • Current Setup  Thermo Scientific Model 42i Chemiluminescence NO-NO2-NOX  System currently collects NOX data on their DAHS and PLCs.5
  • Chemiluminescence  The Chemiluminescence process: NO + O3  NO2 + O2 + hv  NO and O3 react to produce a characteristic luminescence with an intensity linearly proportional to NO concentrations.6
  • 42i Flow Schematic7
  • Collecting Data  Its was easier and more cost effective to install a temporary datalogger than set up NO2 readings in their current DAHS and PLC Systems.  A Campbell Scientific CR1000 datalogger was hooked up to unused ports on the 42i and programmed to take 1 minute readings of NO, NO2, and NOX.8
  • Equipment Setup9
  • Results10
  • Conclusions and Considerations  Cost effective and simple (less invasive) way to collect in-stack NO2/NOX information for use modeling NO2 using AERMOD’s OLM or PVMRM options.  Many facilities currently operate NOX CEMS under a variety of programs.  DAHS systems could also be set up to collect this information.  If no NOX CEMS is in place this data can also be collected during NOX testing.  Protocol Considerations • Statistical Analysis • QA/QC11
  • Questions? Dan Dix ddix@all4inc.com (610) 933-5246, extension 18 2393 Kimberton Road Kimberton, PA 19442 All4 Inc. www.all4inc.com12